• Title/Summary/Keyword: 간접 교정

Search Result 54, Processing Time 0.028 seconds

Direct and indirect bonding of wire retainers to bovine enamel using three resin systems: shear bond strength comparisons (부착 유지장치의 직, 간접 부착법에 따른 전단 접착력 비교)

  • Kwon, Tae-Yub;Meina, Hu;Antoszewska, Joana;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.447-453
    • /
    • 2011
  • Objective: We compared the shear bond strength (SBS) of lingual retainers bonded to bovine enamel with three different resins using direct and indirect methods. Methods: Both ends of pre-fabricated twisted ligature wires were bonded to bovine enamel surfaces using Light-Core, Tetric N-Flow, or Transbond XT. Phosphoric acid-etched enamel surfaces were primed with One-Step prior to bonding with Light-Core or Tetric N-Flow. Transbond XT primer was used prior to bonding with Transbond XT. After 24 hours in water at $37^{\circ}C$, we performed SBS tests on the samples. We also assigned adhesive remnant index (ARI) scores after debonding and predicted the clinical performance of materials and bonding techniques from Weibull analyses. Results: Direct bonding produced significantly higher SBS values than indirect bonding for all materials. The SBS for Light-Core was significantly higher than that for Tetric N-Flow, and there was no significant difference between the direct bonding SBS of Transbond XT and that of Light-Core. Weibull analysis indicated Light-Core performed better than other indirectly bonded resins. Conclusions: When the SBS of a wire retainer is of primary concern, direct bonding methods are superior to indirect bonding methods. Light-Core may perform better than Transbond XT or Tetric N-Flow when bonded indirectly.

Experimental study for the development of using hydrophone bedload discharge estimation equation (하이드로폰을 이용한 소류사량 추정 관계식 개발을 위한 실험적 연구)

  • Kim, Hyeongyu;Choi, Jongho;Jun, Kyewon;Kim, Sunguk;Lee, Donghyeok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.146-146
    • /
    • 2020
  • 최근 하천의 유사 중 소류사량을 계측하기 위해 사용된 기존의 물리적 소류사 샘플러를 이용한 직접계측방법은 홍수 시에 깊은 수위와 빠른 유속, 계측 절차상의 위험성 때문에 현장관측이 매우 어려운 한계를 극복하기 위해 현업에서는 소류사량을 간접적으로 추정하는 이론식에 의한 방법이 광범위하게 활용되고 있으나 이 방법 또한 추정이론식의 적용지역, 적용방법에 따라 결과가 수십배 이상 큰 차이를 나타나 실제 활용성에 대한 문제점이 있다. 이러한 기존의 소류사량 측정 방법의 문제점을 보완하기 위해 소류사량을 간접계측하는 방법이 활발히 제안되고 있다. 대표적인 방법으로 하상 이동 시 소류사의 충돌음을 음향센서로 계측하여 신호처리를 통해 소류사량을 추정하는 계측기기인 하이드로폰이 있다. 그러나 국외의 소류사량 간접계측 장치는 소류사량의 운송량이 많을 경우 음향신호 중접으로 인해 펄스 수의 감소, 감지 가능한 입경크기의 제한 등의 문제가 있다. 또한 국내의 백무평(2018)이 제안한 소류사 분석 방법인 대역통과방법(B-P Method)는 소류사량 추정에 있어서 기존의 방법과는 달리 주파수 특성을 반영하여 이전 연구들에 비하여 펄스 검출률을 향상시겼지만 이 방법은 극히 낮은 저유속과 작은 입경이라는 실험조건에서 이루어졌다는 제한사항이 있다. 따라서 본 연구는 다양한 입경과 고유속에 대하여 소류사량을 정량화할 수 있는 방법을 제시하기 위해 소류사 입경이 하이드로폰에 충돌할 때 발생하는 단독입자의 충돌음을 계측하기 위한 실외 수로실험장치를 구축하여 계측을 수행하였다. 실험은 현장에서 대표 시료로 분류된 몇 가지 입경에 대해서 유량 변화에 따른 충돌음향과 소류사량 그리고 소류사 입경크기에 따른 하이드로폰에서 인지되는 음향 특성을 계측 및 분석하였다. 연구결과 입경 크기 및 수리조건 변화에 따른 하이드로폰의 충돌음향 특성을 파악하여 단일 입경별 소류사량 추정관계식을 산출하였다. 또한 산출된 추정 관계식의 특성치와 공급 소류사량 간의 관계를 유도해 보았다. 향후 혼합입경에 대한 실험과 추정 관계식 신뢰성 검토 후 추가적으로 다양한 실험조건을 고려하여 실제 하천에 운송되는 소류사량과의 교정관계 확립을 진행한다면 국내 소류사량 데이터 수집을 위한 현장 설치까지 가능할 것으로 사료된다.

  • PDF

Surgical Correction of Total Anomalous Pulmonary Venous Return (총폐정맥 환류이상증의 외과적 치료)

  • 금동윤;이광숙
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.292-296
    • /
    • 1996
  • Total anomalous pulmonary venous return is a rare but serious cardiac malformation, accounting for only about 1.5~3% of congenital heart disease. Surgical results have been dramatically improved in the last two decades, largely owing to improved techniques of cardiopulmonary bypass and perloperative management. Seven patients ranging in age from 15 days to 11 years with total anomalous pulmonary venous return underwent repair between 1984 and 1995. The types of anomalous return were supracardiac in 5, and cardiac in 2. There were 5 boys and 2 girls. There were two hospital death, occurred in 15-day-old, and 40-day-old infants with supracardiac type. Follow-up periods have ranged from 3 months to 11 years, and all survivors have remained asymptomatic with normal growth and development.

  • PDF

The study on the cleft lip and/or palate patients who visited Dept. of Orthodontics, Seoul National University Dental Hospital during last 11 years (1988.3-1999.2) (최근 11년간 서울대학교병원 교정과에 내원한 순구개열 환자의 내원 현황에 관한 연구(1988.3 - 1999.2))

  • Yang, Won-Sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.467-481
    • /
    • 1999
  • Cleft lip and/or palate is one of the most common congenital craniofacial anomalies. According to previous epidemiologic studies, incidence of cleft lip and/or palate has been increasing nowadays. However, there is no report about epidemiologic study of cleft lip and/or palate patients who visited dept. of orthodontics in Korea. So the purpose of this study was to provide the epidemiological characteristics and important basic clinical data for the diagnosis and the treatment of the cleft lip and/or palate patients. With the orthodontic and cleft charts, diagnostic models and X-ray films from 250 patients with cleft lip and/or palate who visited Dept. of Orthodontics, Seoul National University Dental Hospital during the last 11 years, the authors investigated patient's visiting yew, types of cleft, patient's gender, and Angle's classification of malocclusion, and surgery timing. The results were as follows ; 1. The number of cleft patients who visited Dept. of Orthodontics, SNUDH increased during 1988-1990 and then it declined until 1992. From 1993 to 1996, it showed a stationary trend. After 1997 it showed an overwhelmingly increasing trend. 2. In the cleft type, the ratio of cleft lip cleft lip and alveolus cleft palate : cleft lip and palate was 7.6:19.2:9.6:63.6. In cleft position, unilateral clefts were more than bilateral ones (cleft lip 79:21, cleft lip and alveolus 77:23, cleft lip and palate 75.5:24.5). In cleft side, left clefts were mote than right clefts (cleft lip 53.3:46.7 cleft lip and alveolus 59.5:40.5, cleft lip and palate 59.2:40.8). 3. In gender ratio, males were more than females in cleft lip (57.9:42.1), cleft lip and alveolus (68.8:31.2) and cleft lip and palate (76.1:23.9). But in cleft Palate females were more than males as 41.7: 58.3. 4. In the age groups, 7-12 year group was the most abundant as $52\%$, and then 0-6 year group ($20.4\%$), 13-18 year group ($17.2\%$), more than 18 yew group ($10.4\%$) were followed as descending order. 5. Most of the cleft lip repair surgeries were operated in 0-3 month ($60.3\%$) and 4-6 month ($17.9\%$). 6. The cleft palate repair surgeries were done in 1-2 year ($31.7\%$), 0-1 year ($25.6\%$), 2-3 year ($12.1\%$), more than 5 year ($11.6\%$) as descending order. 7. The lip scar revision surgeries were done before admission at elementary school in $60\%$. (4-6 you ($27.5\%$), 6-8 year ($19.6\%$), more than 10 year ($19.6\%$), 2-4 year ($13.7\%$) as descending order) 8. The rhinoplasties were done before admission at elementary school in $51.7\%$. (0-2 year ($7.1\%$), 2-4 year ($14.3\%$), 4-6 year ($21.4\%$), 6-8 year ($14.3\%$)). 9. The pharyngeal flap were done at 6 Y (72.5 months) after birth on average and there was even distribution of surgery timing. 10. In relationship between Angle's classification of malocclusion and cleft types, Class I was most abundant and Class III, Class II were followed as descending order in cleft lip group. But Class III was most abundant and Class I, Class II were followed as descending order in cleft lip and alveolus group, cleft palate group, and cleft lip and Palate group. The percentage of frequency in Class III malocclusion was overwhelmingly higher in cleft lip and palate group than any other groups. 11. Because the frequency of class III malocclusion was most prevalent in all age groups, anterior crossbite was the most common chief complaint of cleft patients.

  • PDF

Determining Kinetic Parameters and Stabilization Efficiency of Heavy Metals with Various Chemical Amendment (중금속 안정화제의 반응 매개변수 결정 및 중금속 안정화 효율성 평가)

  • Oh, Se-Jin;Kim, Sung-Chul;Kim, Tae-Hee;Yeon, Kyu-Hun;Lee, Jin-Soo;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1063-1070
    • /
    • 2011
  • In this study, total of 5 different chemical amendments were evaluated for determining kinetic parameters and stabilization efficiency of heavy metals in aqueous phase. Standard solution of Cd and Pb ($100mg\;L^{-1}$) was mixed with various ratio of amendments (1, 3, 5, 10%) and heavy metal stabilization efficiency was monitored for 24hrs. All examined amendments showed over 90% of removal efficiency for both Cd and Pb except zerovalent iron (ZVI) for Cd (43-63%). Based on result of heavy metal stabilization efficiency, it was ordered as $CaCO_3$ > Dolomite > Zeolite > Steel slag > ZVI for both Cd and Pb in aqueous phase. For kinetic study, first order kinetic model was adapted to calculate kinetic parameters. In terms of reaction rate constants (k), zeolite showed the fastest reaction rate (k value from 0.4882 for 1% to 2.0105 for 10%) for Cd and ZVI (k value from 0.2304 for 1% to 0.5575 for 10%) for Pb. Considering reaction rate constant and half life for heavy metal stabilization, it was ordered as Zeolite > $CaCO_3$ > Dolomite > Steel slag > ZVI for Cd and $CaCO_3$ > Dolomite > Steel slag > Zeolite > ZVI for Pb. Overall result in this study can be interpreted that lime containing materials are more beneficial to remove heavy metals with high efficiency and less time consuming than absorbent materials.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.

Analysis of Gas Flow Behavior with Experiments for LPG releasing and 3D Mapping of Gas Sensor (LPG 누출 및 가스센서 3D Mapping을 통한 가스유동현상 분석)

  • Kim, Jeong Hwan;Lee, Min-Kyung;Kil, Seong-Hee;Lee, Jin-han;Jo, Young-do;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.45-55
    • /
    • 2017
  • Release and fire/explosion tests of flammable gas are extremely dangerous. Furthermore, it is difficult to select the site where the experiment can be performed. In these reasons, gas flow analysis(CFD) has been used as much as possible. However, with the opening of the Energy Safety Empirical Research Center in Yeongwol-gun, Gangwon-do in October 2016, it was possible to conduct releases and detection tests of small scale combustible gas as well as large scale / high pressure / ultra low temperature experiments. In this study, LPG leaked after the calibration and placement of the sensor, the sensor detected LPG and the data were visualized as a contour map. And the differences between the actual release(28s, max 3.7[m]) and the analysis were analyzed compared to the FLACS analyzed under the same conditions.

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

Effect of Simple VSD Repair on Doppler-Derived Right Ventricular Systolic Time Interval (심실중격결손 봉합이 우심실 수축기 시간 간격에 미치는 영향)

  • 정태은;이영환
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.124-129
    • /
    • 1999
  • Background: Ventricular septal defect(VSD) that causes pulmonary hypertension increase right ventricular workload. Echocardiographic assessment of right ventricular systolic time interval (RVSTI) has been used to predict pulmonary artery pressure in various cardiopulmonary diseases. This study was undertaken in infants with simple VSD to observe the alteration of the right ventricular workload through the changes of RVSTI after repair of VSD. Material and Method: We evaluated heart rate, the ratio of the left atrium/aortic root diameter (LA/Ao), right ventricular pre-ejection period(RVPEP), right ventricular ejection time(RVET), and its ratio(RVPEP/RVET) as a predictor of right ventricular workload in 12 children with simple VSD. These were measured three times at the preoperative period, at the 3 month and between 6 month and 1 year(average 9.5${\pm}$1.8month) after repair of VSD by M-mode & Doppler echocardiograph from the pulmonic valve echogram. Result: Heart rate was decreased significantly after repair(137.1${\pm}$13.7 vs 114.4${\pm}$21.1 and 104.1${\pm}$10.2, p<0.01). LA/Ao ratio was decreased significantly after repair(1.71${\pm}$0.32 vs 1.47${\pm}$0.33 and 1.39${\pm}$0.23, p<0.05). RVPEP/RVET were decreased after repair (0.38${\pm}$0.09 vs 0.32${\pm}$0.08 and 0.29${\pm}$0.09, p<0.01). Heart rate corrected RVPEP/RVET were significantly decreased only after 6 months(0.32${\pm}$0.03 vs 0.30${\pm}$0.05 and 0.28${\pm}$0.06, p<0.05). Conclusion: We found elevated right ventricular workload was progressively decreased until more than 6 months after repair and the RVSTI may serve a useful guide in postoperative care for children with VSD.

  • PDF

The effect of bracket width on frictional force between bracket and arch wire during sliding tooth movement (치아의 활주 이동시 브라켓 폭이 브라켓과 호선 사이의 마찰력에 미치는 효과)

  • Choi, Won-Cheul;Kim, Tae-Woo;Park, Joo-Young;Kwak, Jae-Hyuk;Na, Hyo-Jeong;Park, Du-Nam
    • The korean journal of orthodontics
    • /
    • v.34 no.3 s.104
    • /
    • pp.253-260
    • /
    • 2004
  • Frictional force between the orthodontic bracket and arch wire during sliding tooth movement is related to many factors, such as the size, shape and material of both the bracket and wire, ligation method and the angle formed between the bracket and wire. There have been clear conclusions drawn in regard to most of these factors, but as to the effect of bracket width on frictional force there are only conflicting studies. This study was designed to investigate the effect of bracket width on the amount of frictional forces generated during clinically simulated tooth movement. Three different widths of brackets $(0.018{\times}0.025'\;standard)$ narrow (2.40mm), medium (3.00mm) and wide (4.25mm) were used in tandem with $0.016{\times}0.022'$ stainless steel wire. Three bracket-arch wire combinations were drawn on for 4 minutes on a testing apparatus with a head speed of 0.5mm/min and tested 7 times each. To reproduce biological conditions, dentoalveolar models were designed with indirect technique using a material with similar elastic properties as periodontal ligament (PDL). In addition, to minimize the effect of ligation force, elastomer was used with added resin, which was attached to the bracket to make up for the discrepancies of bracket width. The results were as follows: 1. Maximum frictional force for each bracket-arch wire combination was: Narrow (2.40mm): $68.09\pm4.69gmf$ Medium (3.00mm): $72.75\pm4.98 gmf$ Wide (4.25mm): $72.59\pm4.54gmf$ 2. Frictional force was increased with more displacement of wire through the bracket slot. 3. The ANOVA psot-hoc test showed that the bracker width had no significant effect on frictional force when tested under clinically simulated conditions(p>0.05).