• Title/Summary/Keyword: 간접측정법

Search Result 213, Processing Time 0.033 seconds

Assessment of the Radiological Inventory for the Reactor at Kori NPP Using In-Situ Measurement Technology (In-Situ 측정법을 이용한 고리 원자로 방사선원항 평가)

  • Jeong, Hyun Chul;Jeong, Sung Yeop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.171-178
    • /
    • 2014
  • After the expiration of operating license of a plant, all infrastructures within the plant must be safely dismantled to the point that it no longer requires measures for radiation protection. Despite the fact that Kori 1 and Wolsong 1 are close to the expiration of their operating license, sufficient technologies for radiological characterization, decontamination and dismantling is still under development. The purpose of this study is to develop one of methods for radiological inventory assessment on measuring object by using direct measure of large component with In-Situ measurement technique. Radiological inventory was assessed by analyzing nuclide using portable gamma spectroscopy without dismantling reactor head, and the result of direct measurement was supplemented by performing indirect measurement. Radiochemical analysis were performed on surface contamination samples as well. During the study, radiological inventory of reactor vessel calculated expanding the result. Based on the result and the radioactivity variation of each radionuclides time frame for decommissioning can be decided. Thus, it is expected that during the decommissioning of plants, the result of this study will contribute to the reduction of radiation exposure to workers.

Application of Back Analysis Technique Based on Direct Search Method to Estimate Tension of Suspension Bridge Hanger Cable (현수교 행어케이블의 장력 추정을 위한 직접탐색법 기반의 역해석 기법의 적용 )

  • Jin-Soo Kim;Jae-Bong Park;Kwang-Rim Park;Dong-Uk Park;Sung-Wan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.120-129
    • /
    • 2023
  • Hanger cable tension is a major response that can determine the integrity and safety of suspension bridges. In general, the vibration method is used to estimate hanger cable tension on operational suspension bridges. It measures natural frequencies from hanger cables and indirectly estimates tension using the geometry conditions of the hanger cables. This study estimated the hanger cable tension of the Palyeong Bridge using a vision-based system. The vision-based system used digital camcorders and tripods considering the convenience and economic efficiency of measurement. Measuring the natural frequencies for high-order modes required for the vibration method is difficult because the hanger cable response measured using the vision-based system is displacement-based. Therefore, this study proposed a back analysis technique for estimating tension using the natural frequencies of low-order modes. Optimization for the back analysis technique was performed by defining the difference between the natural frequencies of hanger cables measured in the field and those calculated using finite element analysis as the objective function. The direct search method that does not require the partial derivatives of the objective function was applied as the optimization method. The reliability and accuracy of the back analysis technique were verified by comparing the tension calculated using the method with that estimated using the vibration method. Tension was accurately estimated using the natural frequencies of low-order modes by applying the back analysis technique.

H$_2$S Sensing Characteristics of SnO$_2$ thick-film devices (SnO$_2$ 후막형 센서를 이용한 H$_2$S 감응특성연구)

  • Kim, Han-Su;Kim, Sun-Tae;Lee, Chul-Hyo;Kim, Heon;Han, Sang-Do
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.153-154
    • /
    • 2002
  • 현재 환경분야의 측정은 주로 분광분석을 중심으로 하는 분석기기법과 $CO_2$, NH$_3$, H$_2$S, HCl 등의 몇몇 유독가스 측정을 위한 이온 선택성전극을 사용한 화학센싱법이 활용되고 있다. 그러나 기기분석을 위한 전처리 방법 및 시료가스의 채취시 가스를 용액에 흡수시킨 뒤에 분석하는 간접적인 방범이 취해지기 때문에 다근 가스의 영향을 극소화시키는데 많은 어려움이 있다. (중략)

  • PDF

An Analysis of Sediment Characteristic in Gongju(2007) (공주지점의 유사량 특성 분석(2007))

  • Go, Ju-Yoen;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.918-922
    • /
    • 2008
  • 본 연구에서의 측정 대상인 공주지점은 금강 본류로 홍수 예 경보 지점이며, 그 하상이 대부분 모래로 구성된 충적하천으로 간주된다. 유사량 측정은 강우가 집중되는 6$\sim$9월의 홍수기(25회)와 이를 기준으로 전 후시기인 저 평수기(2회)로 나누어 총 27회로 측정하였고 부유사량(D-74, P-61A: 수심적분법), 하상토(BM-54, 홍수기전 후 2회 채취), 수리량(수위, 유속, 측정수심, 수면폭, 수면경사, 수온)등의 실측자료를 이용하여 미측정구간의 유사량을 포함한 총유사량을 추정(실측+계산; Modified Einstein, 간접계산; Engelund & Hansen, Yang, Ackers & White)하였다. 이러한 분석결과를 가지고 유량-부유사농도와 부유사량 및 총유사량 관계에 대해 살펴보았다. 전체적으로 유량에 대한 측정성과들의 변위와 저유량시 산포도에 있어 다소 큰 경향을 보였고, 주요 강우사상별로 보았을 때 루프(Loop)현상을 볼 수 있었다. 이러한 분석결과의 상충은 하천의 수리, 유사특성과 추정방법의 적용한계 등의 서로 다른 제한된 범위의 자료들을 이용하여 분석하는 데서 오는 차이, 특히 유량, 수심, 하상토의 입경크기 등 자료의 범위가 추정공식들이 추천하는 범위에서 벗어났기 때문인데, 이는 총유사량 공식에 대한 범용성이 적다는 것을 의미한다.

  • PDF

Performance test of urine bioassay through participation in the NRIP (NRIP 참여를 통한 소변시료 바이오어세이 성능검사)

  • Ha, Wi-Ho;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.96-102
    • /
    • 2014
  • Urine bioassay has been widely used for internal dosimetry due to simple process of sampling and measurement. In this paper, we participated in the NRIP (NIST Radiochemistry Intercomparison Program) hosted by US NIST to carry out a reliable performance test of urine bioassay and introduced the measurement method and results of NRIP-2013. In customary exercise with 60 days of reporting time, bioassay results of 12 radionuclides in the synthetic urine samples were acceptable based on the performance criteria of ANSI N13.30. In emergency preparedness exercise with 8 hours of reporting time, bioassay results of 9 radionuclides showed that differences ranged from -35% to 45%. However, we concluded that urine bioassay applied for emergency preparedness exercise would be applicable for rapid screening and estimation of internal exposure within a difference of ${\pm}45%$ in the event of radiological accidents.

Serodiagnosis of human paragonimiasis by ELISA-inhibition test using monoclonal antibodies (단클론항체를 이용한 폐흡충증의 면역진단)

  • Yong, Tae-Sun;Seo, Jang-Hun;Yeo, In-Seok
    • Parasites, Hosts and Diseases
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 1993
  • ELISA-inhibition test using Paragonimus westermani specific monoclonal antibody (Mab) was investigated to improve the diagnostic specificity of paragonimiasis. By cell fusion, one hybridoma clone secreting un-n westemanl specific Mab was selected (Pwa-14), which reacted on bands of 28 kDa, 42.5 kDa, 89 kDa and 120.5 kDa. IFA showed Pwa-14 was located at the vitelline follicles. By micro-ELISA, 100% of 22 paragonimiasis cases were found positive, but 5 of 40 clonorchlasls cases (12.5%),3 of 26 cystlcercosis cases (7.7%) showed false positive. None of 10 sparganosis patients or 28 normal controls reacted positively. On the other hand, by ELISA-Inhibition test using a R westermcni specific Mab, 100% of patagonimlasls cases were found positive, and there were no positive in cysticercosis, sparganosis cases or normal controls, except 2 (5.0%) false-positive sera of 40 clonorchiasis cases. The ELISA-Inhlbltlon test using a Mab showed higher specificity in comparison with macro-ELISA for serodlgnosis of human paragonimlasis.

  • PDF

Assessment of Allergenicity of Fermented Dairy Products by Immunoassay (면역 분석법을 이용한 발효 유제품의 알레르기원성 평가)

  • Kang, Kun-Og
    • The Korean Journal of Food And Nutrition
    • /
    • v.19 no.3
    • /
    • pp.296-300
    • /
    • 2006
  • Immunoblotting and competitive indirect enzyme-liked immunosorbent assay(Ci-ELISA) was used for detection of ${\beta}$-lactoglobulin(BLG) in dairy products, such as milk, dried milk and fermented milk. In immunoblotting, human IgE weakly recognized proteins of fermented milk, but still responded to dried milk even though become weak. Rabbit polyclonal antibody to BLG, used as a model of antigen, and milk allergic patients' IgE was used in the ELISA. Reactivities of Abs were the highest in market milk. BLG in fermented milk was detected in a low content. This result indicates the fermented milk have the lowest BLG content and could be used as hypo-allergenic food for milk-allergic individual.

The Development and Introduction of External Corrosion Direct Assessment Measures for Urban Gas Pipelines (외면부식 직접평가법 개발 및 국내 도입 연구)

  • Ryou, Young-Don;Lee, Jin-Han;Yoon, Yung-Ki;Lim, Ho-Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.12-19
    • /
    • 2014
  • To minimize the risk of corrosion on buried pipeline and to maximize the efficiency of cathodic protection, various indirect inspection techniques have been used for decades. In the United States, 49 CFR has regulated the external corrosion direct assessment for buried pipelines. In Korea, there is no provision for external corrosion direct assessment but there is only, according to the KGS Code, provision that if the survey of the defects of buried pipeline and the leakage test for the pipe were conducted, it is deemed to leakage inspection. We, therefore, have suggested external corrosion direct assessment method appropriate to domestic status through the survey of the regulations and standards of UK and the USA and the investigation of domestic situation on coating damage detection method. The proposed external corrosion direct evaluation method was used as the basis when introducing the precision safety diagnosis regulation for the medium-pressure pipe in Korea.

Study of the Electrolytic Reduction of Uranium Oxide in LiCl-Li$_{2}$O Molten Salts with an Integrated Cathode Assembly

  • Park Sung-Bin;Seo Chung-seok;Kang Dae-Seung;Kwon Seon-Gil;Park Seong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 2005
  • The electrolytic reduction of uranium oxide in a LiCl-Li$_{2}$O molten salt system has been studied in a 10 g U$_{3}$O$_{8}$ /batch-scale experimental apparatus with an integrated cathode assembly at 650$^{\circ}C$. The integrated cathode assembly consists of an electric conductor, the uranium oxide to be reduced and the membrane for loading the uranium oxide. From the cyclic voltammograms for the LiCl-3 wt$\%$ Li$_{2}$O system and the U$_{3}$O$_{8}$-LiCl-3 wt$\%$ Li$_{2}$O system according to the materials of the membrane in the cathode assembly, the mechanisms of the predominant reduction reactions in the electrolytic reactor cell were to be understood; direct and indirect electrolytic reduction of uranium oxide. Direct and indirect electrolytic reductions have been performed with the integrated cathode assembly. Using the 325-mesh stainless steel screen the uranium oxide failed to be reduced to uranium metal by a direct and indirect electrolytic reduction because of a low current efficiency and with the porous magnesia membrane the uranium oxide was reduced successfully to uranium metal by an indirect electrolytic reduction because of a high current efficiency.

  • PDF

수질 모니터링을 위한 암모니아 분석 칩과 중금속 센서

  • Park, Jun-Sik;Hwang, Gil-Ho;Gang, Seong-Gun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.18.2-18.2
    • /
    • 2011
  • 생활수준이 향상되고, 환경오염이 가속되면서 환경에 대한 관심이 더욱 증대되고 있다. 수질센서의 경우, 그 측정 항목이 매우 다양하고, 높은 정밀도를 요하고 있을 뿐만 아니라 지속적인 실시간 모니터링을 요구하고 있어, 기술적으로 해결해야 할 문제가 많이 남아 있다. 또한, 현재 약 15% 정도로 매우 낮은 국산화율을 보이고 있어, 대부분의 주요 센서들이 수입에 의존하고 있는 실정이다. 수질을 측정하기 위한 센서는 크게 두 가지 형태로 나누어 질 수 있는데, 하나는 flow injection analysis (FIA) 방식이며, 다른 하나는 Probe 방식의 센서이다. 본 발표에서는 수질 센서에 대한 최근 국내 기술 동향과, 수질 모니터링을 위한 Lab-on-a-chip 형 암모니아 분석 칩, Probe 형 중금속 센서 연구 개발 결과를 요약하고자 한다. 암모니아 분석 칩은 마이크로 유체 소자 내에서 Berthelot reaction을 유도하고, 흡광법에 의하여 물 속에 존재하는 암모니아를 간접적으로 측정하는 방법이다. 또한, 중금속 센서로 일반적인 working electrode 소재로 사용되는 독성이 있는 Hg 보다 친환경적인 개발된 bismuth-modified carbon nanotube와 같은 Bi계 복합소재를 적용하여 물 속에 존재하는 저 농도의 Pb, Cd, Zn을 측정 분석할 수 있었다. 본 연구를 통해 개발된 분석칩과 중금속 센서를 이용하여 하천에서 샘플링된 물에서의 암모니아 및 중금속 농도를 각각 분석할 수 있었다.

  • PDF