A compact virtual-reality (VR) device with wider field of view provides users with a more realistic experience and comfortable fit, but VR lens distortion is inevitable, and the amount of distortion must be measured for correction. In this paper, we propose two different full-field distortion-measurement methods, considering the characteristics of the VR device. The first is the distortion-measurement method using multiple images based on camera calibration, which is a well-known technique for the correction of camera-lens distortion. The other is the distortion-measurement method by measuring lens distortion at multiple measurement points by rotating a camera. Our proposed methods are verified by measuring the lens distortion of Google Cardboard, as a representative sample of a commercial VR device, and comparing our measurement results to a simulation using the nominal values.
Journal of the Korea institute for structural maintenance and inspection
/
v.25
no.6
/
pp.33-40
/
2021
Measuring the compressive strength of concrete is a very important factor in the safety review of concrete structures. Concrete compressive strength measurement methods include destructive and non-destructive methods. The destructive method includes the uniaxial compression failure method, and the non-destructive method includes the rebound hardness method and the elastic wave measurement method. In this study, the type of measurement method and the effect of reinforcing bars inside the concrete were tested to examine the relationship between them. Regardless of the type of specimen, the average compressive strength by the elastic wave measurement method among the three experimental methods was greater than the average compressive strength by the other methods. When the specimen type is the same, the standard deviation of the measured values of the elastic wave measurement method is smaller than that of the other measurement methods, so it can be seen that the elastic wave measurement method does not show large variance in the measured values compared to the other two measurement methods. When the average compressive strength according to the test method for each specimen was compared with the average compressive strength of the compressive failure test method, the average compressive strength was measured to be high in the order of the elastic wave measurement method, the compression failure test, and the rebound hardness method. Since the measured values of the compressive strength of concrete are different depending on the method of measuring the compressive strength of concrete and the presence or absence of reinforcing bars inside the concrete, further research is required considering the effect of various concrete covers.
Kim, Min Gyu;Kang, Kimchhun;Oh, Jun Oh;Park, Jae Hyeon
Proceedings of the Korea Water Resources Association Conference
/
2016.05a
/
pp.445-445
/
2016
급변하는 개수로 흐름에서 발생하는 바닥전단응력의 분포는 하천구조물 설계에 있어 매우 중요한 요소이다. 하천 구조물 중 호안에 대한 하천설계기준 '설계편 제 24장 호안'에는 호안 설계에 대한 일반적인 사항이 제시 되어 있으나, 구체적인 소류력 또는 유속에 대한 기준, 각 호안공법들의 안정성을 평가하기 위한 시험법 등에 대한 구체적인 기준이 부족한 상황이다. 소류력 측정방법에는 간접측정법과 직접측정법이 있다. 간접측정법에는 Reach-Average공식, Reynolds Stress, TKE공식 (Turbulent Kinetic Energy)이 있고 직접측정법에는 Shear Meter, Preston Tube 등이 있다. 본 연구에서는 바닥전단응력을 직접 측정할 수 있는 1차원 소류력 측정장치를 개발하고, 최대유속 5m/s 가변형 고속수로 실험을 통하여 Reach-Average 공식, Reynolds Stress, TKE 공식으로 산정한 바닥전단응력 값과 1차원 소류력 측정장치 값을 비교 분석하였다. 실험케이스는 총 3개로, 22.42???, 30.00???, 41.00??? 유량을 사류이면서 난류인 상태로 실험을 수행하였다. 분석 결과, 본 연구에서 개발한 1차원 소류력 측정장치의 측정값은 TKE공식과 약 2.3% 차이가 났으며, Reach-Average공식과 약 8.1%, Reynolds Stress는 약 22.1% 차이가 났다. 즉, 본 연구에서 개발한 1차원 소류력 측정장치는 유속 범위(1m/s ~1.6m/s )에서 TKE공식을 이용한 바닥전단 응력과 가장 근사하게 나타나는 것으로 분석되었다.
The accurate measurement of the femoral anteversion is important for the derotational osteotomy. To estimate femoral anteversion, following three major parameters are required; the neck axis, the long axis, and the knee axis. Conventional methods on the basis of 2D images are ambiguous to determine these major axes. As the femur has a complex 3 dimensional structure, the 3 dimensional model should be applied for accurate and reliable measurement of femoral anteversion. In this thesis, we model femur and define three parameters. The neck axis is defined from the femoral head and neck model. The long axis is determined from the cylindrical model of the femoral shaft. The knee axis is also determined from the model of femoral condyles. According to the definition of the femoral anteversion, the femoral anteversion is efficiently estimated from these models. 20 specimens were tested by the conventional 2D imaging method and 3D imaging method witch was developed by authors and the new 3D modeling method. The study provides accurate, fast and human factor free measurement for femoral anteversion.
상업적으로 시판되는 10주 미만의 식용 영계육을 처리하는 공정에서 25 그룹의 내장적출하지 않은 것 또는 내장적출한 도계육을 도계공정의 네지점에서 채취하였다. 도계 공정 각 지점의 계육으로부터 무작위로 선택된 부위에서 껍질을 잘라낸 것, 목의 껍질을 잘라낸 것, 셀룰로스 아세테이트 스폰지 재질의 스왑봉으로 계육을 스왑법으로 채취한 것, 또는 도계육을 통째로 세척한 세척액이다. 총균수, 대장균군, 대장균을 각 시료로부터 증균하였다. 사방 1 cm 안의 평균 로그값(log A)과 사방 25cm안에서 측정된 전체 측값치들의 로그값(N)은각 그룹 당 25개였다. 동일한 처리공정 단계에서 얻은 계육으로부터 얻은 같은 그룹의 세균의 측정값의 경우에, 무작위로 선택한 부위에서 잘라낸 껍질 또는 목에서 벗겨낸 껍질, 세척액 샘플에서 측정한 균수의 집합인 N의 세 값 또는 log A의 세 값은 <0.5 logunit 차이였다.그러나 스왑법으로 측정한 사방 1 cm안의 평균로그값(log A)과 사방 25 cm 안에서 측정된 전체측정치의 로그값(N)의 대략 절반이 다른 방법들로 측정한 동일한 측정항목의 값과 >0.5 log unit 까지 차이가 났다. 이런 결과로부터 도계육에서 무작위로 선택한 부위나 목에서 껍질을 잘라내는 방법, 또는 세척액 채취 등의 샘플링 방법은 도계육 표면의 단위영역 당 유사한 양의 세균이 검출될 것이라는 것을 나타낸다.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.15
no.2
/
pp.97-104
/
2001
The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.
Optimum conditions for making the Au and Al internal standards for TEM have been determined experimentally. The Au internal standard was produced by sputter coating at 9mA for 100 seconds in low vacuum $(\leq1\times10^{-3})$. The Al internal standard was produced by evaporation coating at 7kV for 10 minutes in high vacuum $(\leq1\times10^{-5})$. Measurements of the lattice parameters of andalusite and albite feldspars with this Au internal standard resulted in errors of (a) $ \leq1.2%$ in precion and $\leq0.3%$ in accuracy for andalusite: (b) $\leq0.5%$ in precision and $\leq1.1%$ in accuracy for albite feldspars. The most significant error occurred from the measuring processes of distances and angles of electron diffraction patterns. By employing systematic procedures of measurement with high precision devices, this lattice parameter determination method utilizing the internal standard should be a good alternative to the conventional powder XRD method or the sophisticated CBED method for special samples.
Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
Journal of Soil and Groundwater Environment
/
v.14
no.3
/
pp.1-13
/
2009
Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.
Proceedings of the Korean Vacuum Society Conference
/
2011.02a
/
pp.313-313
/
2011
일반적으로 초친수 박막들은 물의 퍼짐 현상이 발생하여 빠른 건조와 함께 표면에 붙은 이물질 제거와 공기 중의 미세먼지를 흡착을 하지 않음으로써 표면에 워터스폿(water spot, 물자국)이 생기지 않고 다시 깨끗해지는 자가세정 능력을 가져 유리 및 건축자재의 표면처리 용도로써 많이 사용하고 있다. 이러한 초친수 박막을 제조하는 방법으로는 sol-gel법, 진공 증착법, 화학 기상 증착법, 스퍼터링법 등을 이용한다. 이중 스퍼터링법은 높은 증착속도를 얻을 수 있으며, 비교적 낮은 진공도에서 박막제작을 할 수 있다는 장점을 가진다. 본 실험은 RF-magnetron sputtering법을 이용하여 화학적으로 매우 안정하고 높은 투과율을 가지며 기계적 표면 경도가 우수하여 코팅용 박막으로 널리 이용되고 있는 $TiO_2$와 $SiO_2$를 Single Layer와 Double Layer인 $TiO_2/SiO_2$/Glass박막을 제작하여 초친수 특성을 분석하였다. 광학적 특성을 알아보기 위해 UV-vis spectrophotometer장비를 사용하여 측정한 결과 가시광 영역에서 80% 이상의 높은 투과율을 나타내었다. 이는 모든 박막들의 광학적 특성이 우수하여 높은 광학적 특성을 요구하는 분야에 널리 사용 될 수 있다 것이라는 것을 확인 할 수 있었다. 또한 박막의 표면을 확인하기 위해 AFM을 측정한 결과 모든 박막들은 고른 거칠기를 나타내고 있다는 것을 볼 수 있었다. 이것으로 볼때 초친수 역시 초발수 박막의 표면과 마찬가지로 일정한 패턴을 가져야 하는 것을 확인 할 수 있었다. 박막이 초친수성을 띄기 위해 가장 중요시되는 조건인 접촉각이 5도 이하인 조건을 확인을 위해 Contact Angle을 이용하여 접촉각을 측정해 본 결과 박막들은 초친수성의 조건인 5도 보다 더욱 낮은 접촉각의 측정결과를 나타내었다. 위 실험결과를 볼 때 $TiO_2$와 $SiO_2$를 기반으로 단층 혹은 다층으로 박막을 제작하면 더욱 좋은 초친수 특성을 가져 사회적으로 여러 분야에 사용 가능 할 것이라 사료된다.
Kim, Dong-Hwan;Lee, Hyo-Chang;Kim, Yu-Sin;Kim, Yeong-Do;Park, Il-Seo;Gang, Hyeon-Ju;Jeong, Jin-Uk
Proceedings of the Korean Vacuum Society Conference
/
2013.02a
/
pp.580-580
/
2013
공정 플라즈마에서 사용할 수 없는 단일 랭뮤어 탐침법의 단점을 극복하기 위해서 부유 고조화파 탐침법이 개발되었고, 개선되어왔다. 다중 주파수를 인가하여 발생하는 고조화파 신호들 중 상호간섭주파수의 진폭을 이용하는 Sideband 방법과 원신호의 주파수 진폭을 이용하는 이중 주파수 방법이 있는데, 본 연구에서는 위와 같이 응용된 방법들과 기존의 부유 고조화파 탐침법의 장단점을 파악하고, 차이점을 규명하였다. 플라즈마 변수를 이끌어내기 위해 사용된 베셀함수의 민감도를 통해 특정 전자온도 영역에서의 각 방법들의 신뢰성을 비교해보았고, 측정값에서의 차이를 주파수 응답 특성 차이 및 전자 에너지 분포의 차이로 설명하였다. 이런 비교 연구를 통해 상황 별 적합한 측정 방법을 선택적 이용할 수 있을 뿐만 아니라, 이를 통해 측정하는 플라즈마 변수의 신뢰성을 향상시킬 수 있을 것으로 예상된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.