• Title/Summary/Keyword: 가진기 진동량

Search Result 19, Processing Time 0.01 seconds

Research for Effective Vibrational Rapping Performance of Multiple Electrostatic Precipitators in Series and Parallel Arrangements (전기집진기의 직렬 및 병렬식 배열에 따른 효율적인 진동 탈진에 대한 연구)

  • Choi, Ji-Hyun;Kim, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4136-4141
    • /
    • 2013
  • One of the most significant requisite that should be considered for effective rapping of the electrostatic precipitator using electromagnetic vibration exciter is vibration acceleration and resonance frequency of collecting plates. This vibration acceleration shows its peak points when natural frequencies of the system are corresponded with excitation frequency from the power source, and effective rapping performance can be expected. In this research, extend view of single electrostatic precipitator using one electromagnetic vibration exciter, the system was remodeled by arrangement of the exciters in view of multiple modules of the electrostatic precipitator in fields. And vibration acceleration measurement experiment is performed and measured values are compared with these remodeled systems. By this experimental comparison in series and parallel arrangement, effectiveness of arrangement methods for the electromagnetic vibration exciter, expected rapping performance, and power consumption are verified.

An Experimental Study of Vibrator Amplitude Change for a Clamping Force Dispersion and Friction Coefficient Decrease (체결력 산포와 마찰계수의 감소를 위한 가진기의 진동량 변화 실험)

  • Lee, Geum-Gang;Moon, Seok-Man;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.27 no.6
    • /
    • pp.332-337
    • /
    • 2011
  • The object of this experimental study is to investigate influences of vibrator amplitude on clamping force in vibration for bolted joint. The experiment is that change the vibrator amplitude to check clamping force. also the friction coefficient calculated by equation to use an obtained in experiments. The main purpose of generation vibrations is decreasing the clamping force dispersion. also If vibration occurs while tightening the bolt is reduced coefficient of friction. In this paper, In experiments to measure the clamping force before vibrator's amplitude changing. Vibrator's amplitude changes to 5.5mm from 4.4mm. As a result, under various vibration condition, relationship of clamping force and Vibrator amplitude.

Forced Vibration Testing of a Four-Story Reinforced Concrete Frame Building (철근콘크리트조 4층 골조건물의 강제진동실험)

  • Yu, Eun-Jong;Wallace, John W.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.27-38
    • /
    • 2007
  • A series of forced vibration tests and ambient vibration measurement was conducted on a four-story reinforced concrete building damaged in the 1994 Northridge earthquake. Both low amplitude broadband and moderate amplitude harmonic excitation were applied using a linear shaker and two eccentric mass shakers, respectively, and ambient vibrations were measured before and after each forced vibration test. Accelerations, interstory displacements, and curvature distributions were monitored using accelerometers, LVDTs and concrete strain gauges. Natural frequencies and the associated mode shapes fur the first 7 modes were identified. Fundamental frequencies determined from the eccentric mass shaker tests were 70% to 75% of the values determined using ambient vibration data, and 92% to 93% of the values determined using the linear shaker test data. Larger frequency drops were observed in the NS direction of the building, apparently due to damage that was induced during the Northridge earthquake.

Eletromagnetic Field Analysis of SRM Due to Air Gap Eccentricity (Air Gap 편심에 따른 Switched Reluctance Motor의 전자기 가진력 해석)

  • 신현정;이동일;한승도
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.380.2-380
    • /
    • 2002
  • SRM(Switched Reluctance Motor) 내부의 Radial Force는 소음ㆍ진동의 주원인이 되는 가진력으로 작용하는 것으로 알려져 있다. 따라서 본 논문에서는 Radial Force의 주 요인인 Motor 내부의 Air Gap 편심에 따른 반경방향의 전자기 가진력을 전자장 수치해석을 통하여 해석하고 소음ㆍ진동에 미치는 영향을 분석하였다. Air Gap 편심량을 변화시켜 가면서 Stator, Rotor의 Local Force와 Gloval Force인 Torque Fluctuation을 해석하고 이를 실험 결과와 비교함으로서 해석결과의 타당성을 입증하였다.

  • PDF

Assessment of Failure for Fretting-Wear of Steam Generator U-Tubes in Operating Nuclear Power Plants (증기발생기 U-튜브의 마모 손상평가)

  • 김일곤;박진무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.273-279
    • /
    • 1995
  • 본 연구에서는 증기발생기 튜브의 마모마손에 대한 평가 방법을 열수력해석, 자유진동해석, 비선형해석, 마모량예측 등의 과정을 통해 증기발생기튜브의 마모량과 수명을 예측하는 방법에 대해 알아보았다. 본 연구를 통해 얻어진 결론은 다음과 같다. 1) 증기발생기 비선형충격해석에서 사용되는 정확한 난류 여기진동가진 가진력의 확보가 정확한 마모치를 예측할 수 있고, 2) 마모치예상을 위한 수식의 사용시 튜브의 미끌림거리 over bar L값이 매우 주요한 변수임을 알 수 있었다. 3) 충격력과 마모치의 연관관계에 대한 정확한 정의가 본 연구에 사용된 Archard의 마모방정식 이외에 여러 가지가 있으나, 아직 이들에 대한 정보부족으로 더 많은 검토가 필요하다.

  • PDF

A Control of Vibrator Using PM Excited Transverse Flux Linear Motor (영구자석 여자 횡축형 선형 전동기(TFLM)를 이용한 가진기 제어)

  • 임태윤;강도현;김종무;김동희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.281-288
    • /
    • 2002
  • This paper has realized a control system of a vibrator using PM excited Transverse Flux Linear Motor(TFLM). Proposed vibrator can supply a vibration force up to 700[N] at rated current, wide operation range of vibration displacement and high frequency for a tested structure. Also, volume of a vibrator system can be decreased because of a high trust force rato(a thrust force per weight=N/Kg). A proposed vibrator instead of a hydraulic vibrator can improve efficiency and have may advantages of maintenance and management. A desired value command is a vibration frequency and displacement in a controller for a vibrator system and a controlled values we a instant position and velocity of a mover Output value of the controller is phase current controlled by PWM converter. In this research, Dynamic simulation has been executed for analysis of a control algorithm and dvnauuc characteristics and is compared with experimental result.

A Study on the Improvement of the Sound Quality of the Interior Noise of A/T Vehicle in Idle State (공 회전시 자동변속기 차량의 실내소음 음질 개선에 관한 연구)

  • 이상권;최병욱;여승동
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.1
    • /
    • pp.110-119
    • /
    • 1993
  • 본 논문은 자동변속기를 탑재한 차량에서 에어콘(air condition)을 작동시키고, 공 회전시 기어의 변속을 "D"단에 두었을 때 실내에서 발생하는 이상음의 원인규명 및 해결 방 법에 관한 연구 결과를 논하고자 한다. 이 이상한 소음의 원인을 규명하기 위하여 실린더 내부의 연소압력, 메인 베어링캡(main bearing cap)의 진동, 엔진 마운팅 보스의 진동 및 차 량의 실내소음을 동시에 측정하여 분석하였으며 이 결과에 의하면 이상음의 원인은 크랭크 샤프트(crank shaft)의 굽힘진동이 파워플랜트(power plant)를 가진하여 진동을 증가시키고, 이 진동이 마운팅 보스를 통하여 차량의 차체에 전달되며, 차체의 진동에 의해서 발생하는 고체 전달음(structure-borne noise)이었다. 또한 이상음의 주기는 주파수 성분은 200-400Hz 이었다. 이 이상음은 크랭크 샤프트의 댐퍼 풀리의 질량을 저감하여 크랭크 샤프트의 동특 성을 개선함으로서 해결가능하고, 혹은 점화시기를 지연하여 연소 압력을 낮춤으로서 해결 가능하다.

  • PDF

Ground Vibration Test of KF- 16D (KF-16D 지상진동시험)

  • Byun, Kwan-Hwa;Park, Chan-Yik;Kim, Jong-Heon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.5
    • /
    • pp.41-49
    • /
    • 2005
  • This paper discusses the test procedure, instrumentation, verification methodology and the results of the ground vibration test(GVT) performed on the KF-16D aircraft to estimate experimentally dynamic characteristics of the aircraft. The modal tests for 7 external store configurations were conducted to estimate effects of external stores on the aircraft vibration modes. To emulate free-free boundary conditions the test aircraft was mounted on its landing gear structure with deflated tires during the GVT. The airframe modal tests were done by burst random excitations with 6 to 8 shakers and about 200 accelerometers. Frequency response functions(FRFs) were measured for each test, and the FRFs were reduced and analyzed to identify the dynamic parameters interested. The analyses were carried out in two steps. To extract modal parameters such as, frequencies and damping ratios, the poly-reference least square complex exponential method was used in the time domain. The mode shape coefficients were estimated with the least squares frequency domain method to identify the vibration modes.

Ground Vibration Test of the Aircraft (항공기 지상진동 시험)

  • 유홍주;조창민;주영식;김광로
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.35-39
    • /
    • 1993
  • 항공기의 플러터 현상을 예방키 위한 개발시의 주요 공학적 임무로는 플러 터 해석, 풍동 플러터 시험, 실기체에 대한 지상진동시험 및 비행 플러터 시 험이 있다. 이들 업무는 군용 항공기의 경우에는 군사 규격서, 민간 항공기 의 경우는 FAR 규정 등에 항공기 개발 및 개조시에는 필히 수행토록 명시 되어 있으며, 특히 개발항공기의 인증을 받기 위해서는 초도 비행전까지 필 수적으로 완료되어야 하는 업무이다. 이중 항공기 지상진동시험은 개발항공 기의 초도 비행전에 실기체를 대상으로 하는 구조 동특성 규명시험으로써 플러터 해석 모델의 정확도를 입증하고 그 해석모델을 수정하거나 개선시키 는데 필요한 구조의 동특성 변수들을 실험적으로 규명하는 시험이다. 이 시 험은 개발된 항공기의 초도비행허가를 획득하고 비행속도제한을 설정키 위 해서 초도비행 직전에 초도 개발 비행기를 대상으로 필수적으로 수행되어야 하는 필수적 시험이다. 이에 따라 개발된 항공기의 전기체 지상진동시험을 수행하였고, 시험데이터의 모달해석을 하였다. 이 시험을 수행하기 위해 3개 의 가진기를 사용하였고, 모두 159개의 지점에서 주파수응답 함수를 얻었다. 최대 48 채널의 데이터 획득시스템을 사용하였으므로, 네번에 걸쳐 측정위치 를 옮겨 전체데이타를 획득하였다. 지상진동 시험의 최종해석 결과는 유한요 소 모델의 유효성을 검토하는데 사용되었고, 시험 데이타를 이용한 가진응답 해석(Forced Response Analysis)을 통하여 비행플러터 시험시에 사용되는 플러터 가진기의 위치선정 및 가진력의 크기를 결정하는데 이용하였다.ncy)가 저주 파수대로 천이(Lower Shift)하는 현상이 나타났으며, 일정한 작업량이라도 작업중량을 줄이고 작업 빈도를 높여서 작업할 경우에 이러한 현상이 더욱 두드러졌다. 작업시간의 경과에 따른 MVIS의 감소 현상은 작업빈도가 높고 비대칭형 작업일 때 가장 크게 나타났다. 총손실을 줄이고, 상대적 비용절감효과를 갖게할 수 있다고 하였다. 따라서 본 연구에서는 성인 여성기성복의 치수적합성을 높이기위하여 출산 후 중년에 접어 들면서 체형이 변화되는 것을 고려하여 연령을 분류하고(18세-34세, 30세-51세), 각 연령 집단에 따른 체형을 각각 3가지로 분류하였다. 이에 따라 의복 생산시의 총손실을 줄이기위한 상의, 하의생산시 필요한 부위별 최적규격치 간격을 제시하였다.적인 기능으로 보여지는 것에 좁혀서 작업능력의 연령증가 변화에 대하여다원적 평가를 하는 것이 실제적이라고 할 수 있다. 따라서 본 연구에서는 인간이 가지고 있는 다수의 기능중에서 수지교 치성과 연령증가와의 관계를 조사한다. 만약 연령증가 만으로 수지교치성을 평가 할 수 없는 경우에는 어떠한 요인이 수지기민성의 변화에 영향을 미치는가를 검토한다.t list)에서 자동적으로 사건들의 순서가 결정되도록 확장하였으며, 설비 제어방식에 있어서도 FIFO, LIFO, 우선 순위 방식등을 선택할 수 있도록 확장하였다. SIMPLE는 자료구조 및 프로그램이 공개되어 있으므로 프로그래머가 원하는 기능을 쉽게 추가할 수 있는 장점도 있다. 아울러 SMPLE에서 새로이 추가된 자료구조와 함수 및 설비제어 방식등을 활용하여 실제 중형급 시스

  • PDF

3 Channel Measurement Technique Applied to Measure the Low Frequency Region Frequency Response Function (저주파수 영역 주파수 응답함수 측정에 대한 3채널 측정법의 적용)

  • 김경호;한상보
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.74-79
    • /
    • 1995
  • 모우드 밀도의 산정을 정확하게 구하기 위해 고주파수 영역에서 흔히 적용되는 3채널 측정법이 저주파수대 영역에서도 2채널법에 의한 방법보다 주파수 응답함수의 크기 및 공전주파수의 위치를 보다 더 잘 나타내 주고 있다는 것을 실험적으로 제시하였다. 2채널 측정법에 비하여 3채널 측정법이 모우드 밀도가 균일한 보의 경우에 있어서도 주파수 응답함수의 크기를 실제의 경우와 근접하게 추정해 줄 수 있을 뿐 아니라, 상대적으로 모우드 밀도가 높은 평판의 경우에 있어서도 공진주파수 대에서의 주파수 응답함수의 형태를 보다 분명히 나타내어 줄 수 있는 것으로 나타났다. 한편, 구조물과 가진기의 상호작용에 의한 고유진동수의 변동량 측정의 관점에서는 2채널 측정법과 3채널 측정법의 경우 모두 주파수 응답함수를 적절히 나타내어 주고 있는 것으로 나타났다.

  • PDF