• Title/Summary/Keyword: 가이드핀

Search Result 17, Processing Time 0.016 seconds

Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report - (관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 -)

  • Kim, Hyung-Sik;Koh, Il-Hyun;Kim, Sung-Guk;Chun, Yong-Min;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.94-98
    • /
    • 2011
  • Purpose: We present a case of anterior glenoid rim comminuted fracture that was treated with arthroscopic reduction and an AO headless compression screw (HCS) fixation. Materials and Methods: A 31-year old man complained of left shoulder pain after falling down on stairs. The anterior glenoid comminuted fragments were arthroscopically reduced. Fixation with an AO HCS was done after placement of 1.1 mm Kirschner wire as a guide pin through a standard cannulated anterosuperior portal. Results: Twelve months after the operation, union of the fracture was achieved and the range of motion was fully recovered. He did not complain of any discomfort during his activities of daily living. Conclusion: An AO HCS had various screw sizes and this was good for fixation of a small glenoid fracture and a long drill bit and screw driver were useful for fixation of deep seated glenoid fracture. A short guide wire could be replaced by a 1.1 mm K-wire. An AO HCS was useful for fixation of an anterior glenoid rim comminuted fracture.

Stable Power Plan Technique for Implementing SoC (SoC 구현을 위한 안정적인 Power Plan 기법)

  • Seo, Young-Ho;Kim, Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2731-2740
    • /
    • 2012
  • ASIC(application specific integrated circuit) process is a set of various technologies for fabricating a chip. Generally there have been many researches for RTL design, synthesis, floor plan & routing, low power scheme, clock tree synthesis, and testability which are widely researched in recent. In this paper we propose a new methodology of power strap routing in basis of design experience and experiment. First the power strap for vertical VDD and VSS and horizontal VDD and VSS is routed, and then after the problems which are generated in this process are analyzed, we propose a new process for resolving them. For this, the strap guide is inserted to protect the unnecessary strap routing and dumped for next steps. Next the unnecessary power straps which are generated the first inserting process are removed, and the pre-routing is performed for the macro cells. Finally the resultant power straps are routed using the dumped routing guide. Through the proposed process we identified the efficient and stable route of the power straps.

A Study on 6 Edges Reamer for the Improvement of Accuracy of Automotive Cylinder Head Guide Pin (자동차 실린더헤드 가이드 핀의 정밀도 향상을 위한 6날 리머에 관한 연구)

  • Kim Hae-Ji;Kim Nam-Kyung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.81-86
    • /
    • 2004
  • Generally, automotive cylinder head is manufactured by FCD45 material that is hard to cutting materials, and it needs the accurate machining tool fir higher output of engine. This paper is concerned with a study on TiN coated 6 edges reamer for improving machining accuracy of cylinder head guide pin. The reamer shape is changed from 4 edges to 6 edges for the improvement of machining accuracy. Also, TiN coating is applied to the improvement of surface roughness of cylinder head guide pin and tool life of 6 edges reamer. It is noted that 6 edges reamer are effective in controlling the dimensional accuracy and surface roughness as well as increasing tool life.

Failure of Cross-Pin Femoral Fixation after Anterior Cruciate Ligament Reconstruction - A Case Report - (전방십자인대 재건술후 대퇴골 경골핀 고정의 실패 - 증례보고 -)

  • Lee Kee-Byoung;Kwon Duck-Joo;Ji Yong-Nam
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.1
    • /
    • pp.92-95
    • /
    • 2003
  • A 34-year-old man with ACL total rupture due to slip down injury, had received ACL reconstruction using autogenous hamstrings tendon with cross-pin femoral fixation. Postoperative course was as usual. But postoperative 3 months later, he complained posterolateral knee pain, recurrent effusion and mild instability. He was managed repeatitive aspiration and nonsteroid antiinflammatory drugs but was failed to relieve symptoms & signs. In CT scans, perforation of posteromedial femoral cortex of lateral femoral condyle was found. In second look arthroscopy, two pieces of broken femoral cross pin were found in between tibiofemoral Joint which was badly injured cartilage. We considered malposition of pins was the main cause of failure. We propose that femoral tunnel must be made more acute angle and femoral cross-pin guide must be positioned more external rotation 10-20 degree than transepicondylar axis made confirm the cross-pin tunnel position in order to avoid posterior cortex perforation and early failure.

  • PDF

Standardization of machining process for progressive press die (순차이송형 프레스 금형의 가공표준화)

  • Lee, S.M.;Lee, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.114-125
    • /
    • 1993
  • In the present study the newly developed CAD/CAM system is applied to the process of the molding design, machining for mini-sized and precise processive die, and the production of press-stamped parts. When the design of a die was completed by means of CAD, wire cut NC data were generated with the aid of a design drawing in the CAD system and then inputed into the wire cut machine, and with the aid of a hole chart which had been made for this purpose, all the data were classified into the categories of CNC milling, jig boring, jig grinding, and machine center, and then developing a program of generating NC data, errors in process were reduced and programming time was shortened. The program was developed by using Autolisp language which was built-in the CAD, and realizing the intergation of designing a die, generating and processing NC data directly by a designer, designing time and machinery processing time were shorted. And the traditionally required working time for design. NC program required 6 days of work becomes 4 days of work by using the developed CAD/CAM system so that the efficiency shows 150% of the reduction working time. The prpgram of the design of the automation a progressive die mold was developed in the PC-Class Autocad system, therefore development expense could be reduced, and the integration of the CAD/CAM of the progressive die mold with the standard DB being built could be realized.

  • PDF

Arthroscopic Reduction and Fixation of an Anterior Cruciate Ligament Avulsion Fracture From the Tibial Eminence Using Bioabsorbable Pins - Technical Note - (생흡수성 핀을 이용한 소아 경골 과간부 견열 골절의 관절경적 정복 및 고정 방법 - 수술 술기 -)

  • Lee, Su-Chan;Yang, Il-Soon;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.183-187
    • /
    • 2009
  • Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients. Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained. Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.

  • PDF

Development and Validation of a Simultaneous Analytical Method for 5 Residual Pesticides in Agricultural Products using GC-MS/MS (GC-MS/MS를 이용한 농산물 중 잔류농약 5종 동시시험법 개발 및 검증)

  • Park, Eun-Ji;Kim, Nam Young;Shim, Jae-Han;Lee, Jung Mi;Jung, Yong Hyun;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.228-238
    • /
    • 2021
  • The aim of this research was to develop a rapid and easy multi-residue method for determining dimethipin, omethoate, dimethipin, chlorfenvinphos and azinphos-methyl in agricultural products (hulled rice, potato, soybean, mandarin and green pepper). Samples were prepared using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) and analyzed using gas chromatography-tandem mass spectrometry (GC-MS/MS). Residual pesticides were extracted with 1% acetic acid in acetonitrile followed by addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. The extracts were cleaned up using MgSO4, primary secondary amine (PSA) and octadecyl (C18). The linearity of the calibration curves, which waas excellent by matrix-matched standards, ranged from 0.005 mg/kg to 0.3 mg/kg and yielded the coefficients of determination (R2) ≥ 0.9934 for all analytes. Average recoveries spiked at three levels (0.01, 0.1, 0.5 mg/kg) and were in the range of 74.2-119.3%, while standard deviation values were less than 14.6%, which is below the Codex guideline (CODEX CAC/GL 40).