• Title/Summary/Keyword: 가열성능 평가

Search Result 147, Processing Time 0.03 seconds

Evaluation of Spalling Characteristics and Fire Resistance Fiber-Entrained Mixed Cement Concrete at Ultra-High Temperatures (섬유가 혼입된 혼합시멘트 콘크리트의 초고온에서의 폭렬특성 및 내화성능 평가)

  • Jun-Hwan Oh;Ju-Hyun Cheon;Man-Soo Lee;Sung-Won Yoo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.23-29
    • /
    • 2023
  • The goal of this study is to evaluate the bursting characteristics and fire resistance performance of mixed cement concrete containing fibers at very high temperatures. For this purpose, FA-based, Slag-based, and each mix according to the amount of fiber mixed were heated to room temperature, 150℃, 300℃, 600℃, and 900℃, and then the burst shape, compressive strength, and elastic modulus were measured and evaluated. As a result of the experiment, it was found that relatively more surface damage occurred in FA-based specimens when heated at ultra-high temperatures than in slag-based specimens, and there was a difference between the mix without fibers and the mix with fibers when heated at ultra-high temperatures, that is, at 900℃. In the mix without fibers, a decrease in strength of more than 5% occurred. In addition, the elastic modulus also showed the same phenomenon as the compressive strength, and in particular, the decrease in elastic modulus was found to be greater than the amount of decrease in compressive strength. Meanwhile, estimation equations for compressive strength and elastic modulus according to heating temperature were statistically proposed.

Analysis of Thermal Degradation Mechanism by Infrared High-speed Heating of CF-PEKK Composites in Hot Press Forming (핫프레스 공정 기반 CF-PEKK 복합재의 근적외선 고속가열에 의한 열적 열화 반응의 메커니즘 분석)

  • Lee, Kyo-Moon;Park, Soo-Jeong;Park, Ye-Rim;Park, Seong-Jae;Kim, Yun-Hae
    • Composites Research
    • /
    • v.35 no.2
    • /
    • pp.93-97
    • /
    • 2022
  • The application of infrared heating in the hot press forming of the thermoplastic composites is conducive to productivity with high-speed heating. However, high energy, high forming temperature, and high-speed heating derived from infrared heating can cause material degradation and deteriorate properties such as re-melting performance. Therefore, this study was conducted to optimize the process conditions of the hot press forming suitable for carbon fiber reinforced polyetherketoneketone(CF/PEKK) composites that are actively researched and developed as high-performance aviation materials. Specifically, the degradation mechanisms and properties that may occur in infrared high-speed heating were evaluated through morphological and thermal characteristics analysis and mechanical performance tests. The degradation mechanism was analyzed through morphological investigation of the crystal structure of PEKK. As a result, the size of the spherulite decreased as the degradation progressed, and finally, the spherulite disappeared. In thermal characteristics, the melting temperature, crystallization temperature and heat of crystallization tend to decrease as degradation progresses, and the crystal structure disappeared under long-term exposure at 460℃. In addition, the low bonding strength was observed on the degraded surface, and the bonding surfaces of PEKK did not melt intermittently. In conclusion, it was confirmed that the CF/PEKK composite material degraded at 420℃ in the infrared high-speed heating. Furthermore, the spherulite experienced morphological changes and the re-melting properties of thermoplastic materials were degraded.

Experimental Study on Fire Resistance Performance of CFT (Concrete filled Tube) Column according to Cross Section of Steel, Concrete Compressive Strengths and Load Ratios (강관의 크기, 축력비 및 콘크리트 압축강도 변화에 따른 CFT 기둥부재의 내화성능에 관한 실험적 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Min, Byung-Yeol;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.104-111
    • /
    • 2010
  • The strength of steel in a concrete filled steel tube (CFT) is reduced in a fire, but the concrete filled structurally ensures the fire resistance due to its high thermal capacity. This research analyzed the fire resistance performance due to the variances of concrete strength filled inside of steel tube and the load ratios, which can influence on the fire resistance of CFT. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the fire resistance used to 24 MPa concrete showed 27, 113, and 180 minutes according to the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of fire resistance with 40 MPa concrete showed the much lower fire resistance performance than those of 24 MPa concrete. In case of 40 MPa, the fire resistance performance was not increased significantly according to the axial load ratio than that of 24 MPa. The main reason why the higher concrete strength showed lower fire resistance than that of lower guessed the internal stress had the concrete strength weak.

An Experimental Study on the Fire Behavior of Concrete Void Slab under Standard Fire with Loading Condition (표준화재 재하조건 콘크리트 중공슬래브의 피복두께에 따른 화재거동에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Beom-Yeon;Yeo, In-Hwan;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.64-72
    • /
    • 2011
  • The concrete void slab structure with the existing mushroom slab, is the structure that maximizes the advantages, while minimizing the weakness with removing useless body force of the concrete part, located on the center of the slab cross-section, which does not need to support the structural weight. In this research, a fire test is performed to analyze how the blaze behave according to the thickness of slab cover, with the practical span length of concrete void slab for the slab length 7.5 m. With this heating test, we assumed the uniform-load-model considering fixed loads and live loads, and chose the standard fire test condition. We measured the temperature changes and the deflection character according to the depth from the heat exposure side, and assessed the resisting capability according to the standard KS F 2257-1. The result comes out with the EPS model can secure about 2 hour fire-resisting-capability with 50 mm of cover depth.

Performance Assessment of High Strength Concrete Members subjected to Fire (화재피해를 입은 고강도 콘크리트 구조부재의 성능평가)

  • Choi, Eun-Gyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.487-488
    • /
    • 2010
  • This is the experimental and analysis study on the thermal distribution, structural behavior and residual strength of high strength concrete members subjected to fire. The parameters are strength of concrete, cover thickness, loading state and exposure time to fire. The ISO 834 standard fire curve is used to test. The material and structural property of concrete at high temperature are proposed, also.

  • PDF

Automatic diameter control system for Czochralski growth (자동직경제어 Czochralski 성장장치의 제작)

  • Han, J.Y.;Park, S.S.;Lee, S.K.;Ma, D.J.;Kim, Y.H.;Lee, S.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.4
    • /
    • pp.356-362
    • /
    • 1994
  • We developed a computer controlled Czochralski puller which automated entire crystal growing processes. Crystal weighing technique was employed for an automatic diameter control. The performance of the system was evaluated by the growth of $LiNbO_3$ single crystals.

  • PDF

An First Order Approximiate Analytical Solution to Predict Qualitative Performance Characteristics of Stirling Enging (Stirling기관(機關)의 성능예측(性能豫測)을 위한 1차원(次元) 근사해석(近似解析))

  • Kim, Tae Han
    • Current Research on Agriculture and Life Sciences
    • /
    • v.9
    • /
    • pp.87-94
    • /
    • 1991
  • An approximate analytical method to predict performance characteristics of the stirling engines in a preliminary design stage was investigated. In basic equations proposed by walker, typical temperatures of working fluids in expansion and compression spaces were treated the same as those of working fluids in heater and cooler respectively. While the temperature of working fluids in the expansion space was actually lower than that of working fluids in the heater, the temperature of working fluids in the compression space was higher than that of working fluids in the cooler. The aim of this study divided typical temperatures of working fluids in expansion and compression spaces into serval grades, and than evaluated the experimental engine. As the result, the case which working fluids temperature of expansion space was treated as lower than the heater temperature and which that of compression space was treated as higher than the cooler temperature, was much closer to the experimental value.

  • PDF

Correlation Research between Objective and Subjective Image Quality Assessment (객관적 화질 평가와 주관적 화질 평가의 상관관계 연구)

  • Park, Hyung-Ju;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.8
    • /
    • pp.68-76
    • /
    • 2011
  • Due to the high interests of image quality by consumers, the concerned market becomes more heated. Recent digital camera development tendency shows to perform the higher image quality to meet consumers demand of quality satisfaction. However it is hard to confirm that development of objective image quality performance means positive subjective image quality preference. And also, we cannot find out the previous researches concerned on correlation between objective and subjective image quality comparison. Therefore, it is necessary to analyze the consumers preferred images based on objective image quality performance. Throughout this paper, we analyze statistical correlation between the objective and subjective image quality assessment methods by using ISO standards. In these results, we try to find attributes that enhance image quality. We suggest not only to analyze and reflect on customers' preferences, but also to pursue the high quality image performance practically. We expect the results of this paper to positively influence product development.

Arc Analysis of Extra High Voltage Gas Circuit Breaker (초고압 가스차단부 아크 해석)

  • Lee, B.Y.;Park, K.Y.;Song, K.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.64-67
    • /
    • 2000
  • 이 논문에서는 대전류 차단과정에 가스차단기의 차단부내에서 발생하는 아크를 해석하기 위한 기법을 기술한다. 차단부내에서 아크 및 아크에 의해 가열된 가스의 흐름을 해석하기 위해 상용의 유동해석 프로그램인 Phoenics를 이용하였다. 이 프로그램에 아크의 방사에 의한 열전달을 고려하기 위해 아크 모델을 사용자 코딩을 이용하여 결합하였다. 또한 아크전류에 의해 발생한 자계와 전류가 유동에 미치는 영향을 포함시켰으며 유동의 난류특성을 Prandtl의 혼합거리모델을 이용하여 모의하였다. 본 논문에서 제안된 아크해 하여 보았다. 시험결과와의 비교가 여의치 않았으나 계산된 결과로부터 제안된 아크해석기법의 활용가 계산을 확인할 수 있었다. 향후 시험결과와의 비교를 실시할 예정이며 본 연구의 최종적인 목표인 SF6 가스차단기의 대전류 차단성능 평가에 적용 가능하도록 프로그램을 수정 보완해 나갈 것이다.

  • PDF

고무소재의 열응력

  • Gang, Sin-Yeong;Hong, Chang-Guk
    • Rubber Technology
    • /
    • v.11 no.1
    • /
    • pp.12-26
    • /
    • 2010
  • 각종 산업제품의 주요 부품으로 사용되고 있는 고무재료는 사용 중 온도변화에 의해 체적 또는 길이 변화를 수반할 수 있어 결과적으로 고무제품의 성능이나 효율이 영향을 받게 된다. 특히 고온에서 고무제품의 치수변화를 제한하거나 일정치수를 강제할 경우 열수축이나 열팽창에 의해 응력이 발생하게 된다. 따라서 온도 변화에 따른 열응력의 측정은 고무제품의 정밀성과 성능을 평가하는 중요한 수단을 제공한다. 본 연구에서는 고무소재의 열응력 측정을 위한 새로운 측정방법을 개발하였고 이와 관련 새로운 시험장치를 설계, 제작하였다. 고무시편에 일정 변형의 인장을 준 상태에서 가열하면 열응력이 발생한다. 이 때의 열응력은 고무분자 사슬들의 운동성에 기인하며 배향된 고무분자 사슬들이 열역학적으로 랜덤 사슬형태로 돌아가려는 엔트로피적 힘이다. 따라서 온도가 높을수록 그 수축력은 증가하게 된다. 또한 고무분자 사슬의 사전 변형이 증가하면 그 열응력은 증가한다. 이때 열응력은 측정시간이 지남에 따라 최대치에 도달한 후 완화되며 그 완화속도는 설정온도에 의해 영향을 받는다. 여기서는 온도변화에 따른 고무시편의 열응력 측정결과를 소개하고, 고무분자 사슬의 엔트로피 변화와 점탄성적 흐름, 그리고 가열에 따른 고무 시편의 팽창 또는 수축이 열응력에 미치는 영향 등을 논의하였다. 특히 천연고무와 SBR 고무시편의 열응력 차이를 분자사슬의 운동과 연관하여 검토하였고, 가교밀도와 가교시스템이 각각 다른 고무시편에 대해 열응력 발생과에 따른 상관관계를 고찰하였다. 또한 시편의 형태와 두께가 열응력 발생에 미치는 영향도 검토하였다. 충전 배합고무의 경우 열응력에 영향을 미치는 인자로 고무분자 사슬의 운동성과 가교밀도 외에 고무재료와 충전제 사이의 물리 화학적 상호작용도 매우 중요한 요소가 된다. 배합고무에서 충전제의 영향을 검토하기 위해 실리카와 카본블랙을 선택하였고 배합고무의 열응력을 각각 측정하여 이들의 보강효과가 열응력에 미치는 영향에 대해 논하였다.

  • PDF