• Title/Summary/Keyword: 가열곡선

Search Result 154, Processing Time 0.026 seconds

Spalling Prevention of High Strength concrete Corresponding to the Various Heating Curves (가열온도곡선 변화에 따른 고강도 콘크리트의 폭렬방지특성)

  • Han, Cheon-Goo;Pei, Chang-Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.127-134
    • /
    • 2009
  • This study investigated their properties of spalling resistance and residual compressive strength after fire test corresponding to various ISO, RABT heating curves, and contents of hybrid organic fiber of high strength concrete. The results were summarized as following. As fundamental characters of concrete with hybrid organic fiber, the flowability was directly declined as the increase of fiber contents, and air contents were decreased or increased a little bit, but there was not big difference. The compressive strength was gradually declined sluggishly at 28 days. As properties of fire resistance, in case of RABT heating curves, compare with ISO heating curves a spalling aspect showed till range that has much contents of hybrid organic fiber, but they are mostly peeling spalling, which means spalling aspect didn't happen to inside. In conclusion, in case of W/B 25% high strength concrete, the spalling was prevented over 0.04% of contents of fiber at ISO heating curve and over 0.10% of contents of fiber at the RABT heating curve. In case of spalling was prevented, mass reduction rate according to the change of heating temperature curves showed around 7% at ISO heating curves and around 9% at RABT heating curves. The residual compressive strength rate corresponding to the change of heating temperature curves showed 50%~60% at ISO heating temperature curves and 30%~35% at RABT heating temperature curves in case of spalling was prevented.

KSTAR 진공용기 및 플라즈마 대향 부품에 대한 베이킹 해석

  • 이강희;임기학;허남일
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.38-38
    • /
    • 1999
  • KSTAR(Korea Superconducting Tokamak Advanced Research) 핵융합 실험 장치의 진공용기 및 진공용기 내부의 플라즈마 대향 부품들은 초고진공 (5$\times$10-9 Torr)의 달성을 위해 진공용기 내부의 이물질(H2, H2O, CO, CO2, CH4 등) 제거를 목적으로 SS316LN인 진공용기는 25$0^{\circ}C$, 탄소 물질인 플라즈마 대향부품은 35$0^{\circ}C$ 정도까지 가열(이하 베이킹)할 필요성이 있다. 이 가열방법으로 고온 질소가스를 진공용기 이중벽 사이로 흘려주는 방식과 코일에 저주파 교류전류를 흘려 진공용기를 유도가열하는 방식이 고려되고 있는데, 유도가열방식은 최대 유도 전력이 70kW 정도로 실제 베이킹에 필요한 열량을 공급하는데 있어 적잖이 부족하며 또 국부적인 가열 특성으로 인하여 KSTSR의 베이킹 방식은 전자의 가열방식을 우선적으로 채택하고 있다. 본 논문에서는 0-차원 해석을 통하여 진공용기와 플라즈마 대향 부품들에 대한 베이킹 계획을 결정하고 이를 만족시키기 위해 투입해야 할 열량을 직선적으로 증가하는 온도 곡선에서 각 부분의 온도 상승률을 다르게 설정한 세 경우와 F-자 형태로 변화하는 온도 곡선의 경우에 대해 각각 적용하여 시간에 따른 필요열량을 비교.검토하였으며, 이를 근거로 안정적인 베이킹 계획을 선정하였고 이 베이킹 계획의 실현을 위해 투입해야 할 고온 질소가스의 유량과 온도 도달시간까지 매 시간에서의 가스온도를 산출하였다. 토러스 형상의 토카막 진공용기와 플라즈마 대향 부품 및 다층단열재에 대한 해석 모델은 길이가 유한한 0-차원 실린더 모델로 가정하였고, 이에 대한 기하학적 성질 및 열역학적 성질은 유효계수를 고려하여 산출하였다. 진공용기 이중 벽 내부로 흐르는 질소가스의 유량과 온도의 계산은 진공용기 내벽과 외벽을 각각 독립적인 열전달 요소로 가정하여 구성한 모델을 이용하였다. 전체 해석에서 각 열전달 요소의 비열 값은 온도에 따라 변화하는 비열의 특성을 반영하였으며. 진공용기와 플라즈마 대향 부품의 방사율(emissivity)은 앞서 가정했던 각 온도 상승 곡선에 대해서 각각 0.1, 0.2, 1.3의 경우를 가정하여 계산하였다. 직선적으로 증가하는 온도 상승 곡선중 2$0^{\circ}C$/hr의 온도상승율을 갖는 경우가 다른 베이킹 시나리오 모델에 비해 효과적이라 생각되며 초대 필요 공급열량은 200kW 정도로 산출되었다. 실질적인 수치를 얻기 위해 보다 고차원 모델로의 해석이 필요하리라 생각된다. 끝으로 장기적인 관점에서 KSTAR 장치의 베이킹 계획도 살펴본다.

  • PDF

Procedure for the Generation of Pressure/Temperature Operation Limit Curves for Reactor Vessel (원자로용기의 압력.온도 운전한계곡선에 대한 작성절차)

  • Kim, Yil;Choi, Seog-Nam;Park, Sung-Ho
    • Journal of the KSME
    • /
    • v.33 no.5
    • /
    • pp.405-413
    • /
    • 1993
  • 원자로용기의 노심대와 노즐의 압력 . 온도 곡선에 대한 배경 및 적용을 살펴보았다. 그러나 원 자로 용기의 실제 압력 . 온도 곡선은 노심대와 노즐 이외에도 플랜지, 수압 및 수밀시험, 노심 임계, 최저운전온도, 계기오차 등을 고려해야 한다. 이 글에서는 시간당 100.deg. F의 가열 및 냉 각에 대서만 고려하였으나 시간당 10.deg. F, 40.deg. F 등 다른 가열 및 냉각률에 대해서도 고 려하여야 한다. 따라서 원자로용기의 실제 압력 . 온도 곡선은 이 글에서 기술한 것보다 훨씬 복 잡하다. 그러나 어느 경우에라도 압력 . 온도 곡선을 구하는 기본적인 이론 및 방법은 이 글에서 기술한 내용에 기초를 두고 있다.

  • PDF

Study on the Generalization of the Equivalent Point Method for Thermal Evaluation (Equivalent Point Method의 일반적 이용을 위한 연구)

  • Rhim, Jong-Whan
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.575-581
    • /
    • 1990
  • The existence of the equivalent point for a thermal processing system was demonstrated using arbitrarily chosen ideal direct heating curves. i.e. isothermal heating curves at $120^{\circ}C$ for 10min and at $135^{\circ}C$ for 10sec. Under these conditions, G-values and F-values were calculated at various values of Ea- and z-values by applying the Arrhenius and the Bigelow models respectively. The equivalent time and equivalent temperature were determined by both line intersection and linear regression methods. The equivalent points estimated by both the line intersection and the linear regression methods were consistent and their values were the same as the heating time and temperature of the ideal direct heating curves.

  • PDF

Generation of Pressure/Temperature Limit Curve for Reactor Operation (원자로 운전을 위한 압력/온도 한계곡선의 설정)

  • 정명조;박윤원
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.155-164
    • /
    • 1997
  • A reactor pressure vessel, which contains fuel assemblies and reactor vessel internals, has the thermal stress resulting from the cool-down and heat-up of the vessel wall in combination with the pressure stress from system pressure resulting in large stresses. The combination of the pressure stress and thermal stress along with a decrease in fracture toughness may cause through-wall propagation of a relatively small crack. Therefore, it is necessary to define the relations between operating pressure and temperature during cool-down and heat-up. In this study, theory of fracture mechanics for a pressure/temperature limit curve is investigated and a numerical procedure for generating it is developed. Plant-specific limit curves for the Kori unit 1 plant, the oldest nuclear power plant in Korea, have been obtained for several cooling and heating rates and their results are discussed.

  • PDF

A Control System for Automization of Food Sterilizing Process (식품의 가열살균공정 자동화 시스템의 개발)

  • AN Hee-Woo;CHO Hyun-Duk;HAN Bong-Ho;KIM Sang-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.511-519
    • /
    • 1992
  • A microcomputer based control system was constructed to save energy consumption in the thermal sterilizing process. The functional accuracy of system was evaluated through the analysis of the thermal diffusivities of the model solid food, Alaska pollack surimi. The heat penetration curves obtained through the experiments were typical for solid foods. The practical thermal diffusivity calculated from heat penetration curve was a constant value at steady sterilizing temperature, and this was independent of the holding time. At different temperatures, the thermal diffusivity values did not show remarkable differences when compared with those predicted by some experimental equations cited from the literatures. The maximal difference was within the range of $\pm10.0\%$.

  • PDF

Properties of Fire Resistance in Tunnel Concrete According to the Changes of Heating Curve (온도가열곡선 변화에 따른 콘크리트의 내화특성)

  • Pei, Chang-Chun;Noh, Sang-Kyun;Lee, Chan-Young;Lee, Jong-Suk;Lee, Jang-Hwa;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.705-708
    • /
    • 2008
  • To obtain tunnel concrete safety in case of fire, this study analyzed fire proof characteristics by fire proof method change, and the results are as follows. As a fire proof characteristics by RABT temperature heating curve, plain concrete experienced severe spalling by initial extremely high temperature. In view of fire proof method, in the cases of organic fiber mixing method and board method, spalling was prevented, and in the case of spray method, severe spalling of over 100mm depth occurred along with exposure of structural concrete including spray coat by heat stress, etc while metal lath, the stiffener, falls off. As for fire proof characteristics by RWS temperature heating curve, in case of organic fiber inclusion, concrete surface experienced fusion of within 5mm, while in the case of spray method, spray coat was severely spalled to a depth of over 100mm causing structural body concrete to expose its reinforcement, and also in the case of board method, board was fused by high temperature, causing structural body concrete be directly exposed to high temperature, which triggered overall fall-off phenomenon, so in such extraordinary high temperature heating condition, establishment of special fire proof measures is needed.

  • PDF

Time-Temperature Curve of road tunnel for fire (도로터널 내 화재에 따른 시간-온도 가열곡선 도출)

  • Choi, Min-Jung;Jang, Chang-Il;Lee, Sang-Woo;Kim, Joon-Mo;Won, Jong-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.713-716
    • /
    • 2008
  • This study is performed to propose a standard to evaluate fire protection assessment for concrete structures during a fire on road tunnel. Recently, a number of road tunnels have been rapidly increased and fire risk also multiplyed according to extend tunnel length, due to natural features and environmentally-friendly road construction in domestic. But we have not yet been prescribed appropriate time-temperature curve for tunnel fire. Therefore we presented fire design model and investigated time-temperature curve proposed by a foreign country considering traffic, a kinds of vehicles which are a basis of heat rate.

  • PDF

The Influence of Silica Fume and PP Fiber Contents on Explosive Spalling of Concrete (실리카흄 및 PP섬유가 콘크리트의 폭렬에 미치는 영향)

  • Kim, Dong-Joon;Kim, Jeng-Hee;Lee, Jae-Young;Kazunori, Harada;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.382-385
    • /
    • 2011
  • 본 논문은 초고강도콘크리트의 폭렬현상을 연구해 보고자 실리카흄 유무와 PP섬유의 혼입량을 변수로 하여 공시체와 벽체의 폭렬현상을 관찰한 후 변수가 초고강도콘크리트에 어떠한 영향을 주는지를 실험적으로 규명하는 것을 목적으로 하였다. KS F 2257 화재온도이력곡선을 30분 적용하여 콘크리트의 초기 폭렬특성을 실험적으로 검토하였다. 그 결과 공시체의 경우 압축강도가 100 MPa 초고강도콘크리트의 경우에는 실리카흄 여부와 PP섬유 혼입량이 폭렬억제에 관계되는 주요 인자인 것을 알 수 있었으며, 벽체의 경우에는 벽체 시험체의 부분 가열 및 전면 가열 실험을 실시했다. 폭렬 최대 깊이, 시간, 소리 발생 회수를 비교하면 부분 가열이 전체 가열에 비해 폭렬이 빠르고 깊게 발생하는 것으로 나타났다.

  • PDF