• Title/Summary/Keyword: 가스제거

Search Result 1,271, Processing Time 0.03 seconds

Treatment of gas from the vent of a fine chemical plant using a pilot-scale biofilter (파일럿 규모 바이오필터를 이용한 정밀화학공장 배출가스의 처리)

  • Ryu, Hee-Wook;Lee, Tae-Ho;Park, Chang-Ho
    • KSBB Journal
    • /
    • v.24 no.1
    • /
    • pp.47-52
    • /
    • 2009
  • A pilot-plant biofilter (1750 mm W ${\times}$ 2750 mm L ${\times}$ 2000 mm H) packed with polyurethane foam (20 mm W ${\times}$ 20 mm L ${\times}$ 20 mm H) was installed in an fine chemical plant emitting gas streams containing ethyl alcohol, ethyl acetate, and dichloromethane. The biofilter was successfully operated for 30 days under highly fluctuating incoming concentrations (maximum 3500 ppm) at a residence time of 36 and 60 sec. Both ethyl alcohol and ethyl acetate were removed more than 95%, but dichloromethane removal was less than 50%. Malodor was also removed more than 90% from 17 days after start up.

$O_2$-$NH_3$처리한 활성탄의 탈황능 향상에 관한 연구

  • 고윤희;서경원
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.90-96
    • /
    • 1994
  • 본 연구는 에너지를 집중적으로 사용하는 발전소와 대규모 공장 단지에서 발생하는 배기가스 중에 포함된 황산화물의 제거 방법에 관한 것으로서, 활성탄의 적절한 전처리를 통해 이산화황 흡착능을 향상시켜 머지 않은 장래에 엄격히 적용될 대기오염 기준을 만족시킴과 동시에, 오염 물질의 제거 효율이 높고 폐기물 매립의 부담이 없는 건식 탈황 공정의 효율향상에 기여하는 것을 목적으로 하고 있다. Activated Char나 활성탄을 이용하여 황산화물과 질소산화물을 동시에 제거하기 위해서는 Carbon 표면을 적절하게 처리함으로써 활성탄의 촉매활성을 향상시키는 것이 필요하다. 따라서 본 연구에서는 활성탄을 열 및 $O_2$-NH$_3$ 혼합가스로 전처리하여 표면의 특성 변화와 SO$_2$ 흡착능에 미치는 영향을 살펴보았다. Coconut Shell로부터 제조한 활성탄을 NH$_3$의 농도를 변화시켜가며 $O_2$와의 혼합가스로 973~1173K에서 열처리하는 방법에 의해 전처리하여, 이률 고정층 반응기에서 SO$_2$흡착 및 반응실험을 수행하였고, 이 과정 중의 활성탄 표면의 특성변화를 원소분석, TPD(Temperature Programmed Desorption), FTIR(Fourier Transform Infrared Spectroscopy), Acid-Base Titration, SEM(Scanning Electrolic Microscopy)등의 분석 방법을 통해서 알아보았다. 그 결과, 활성탄을 열 및 $O_2$-NH$_3$혼합가스로 처리하여 환원성 분위기 하에서 표면 활성점을 증가시킴으로써 황산화물 흡착제거율이 향상됨을 얻었다.

  • PDF

NOx 분해에서 Microwave Energy의 이용

  • 김재설;김동식;이범석;이동규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.88-93
    • /
    • 1995
  • 연소 배가스에서 NOx 제거시 분자 분해를 위하여 Microwave Energy를 이용했다. 이는 전자파를 흡수하는 고체물질에 전자파를 조사할 때 내부로 부터 가열이 이루어지는 특성과 전파의 진동에 의한 분자내 쌍극자가 진동하는 현상을 이용하여 분자결합이 깨지는 현상을 응용한 것이다. 전자파흡수체로서 Calcined Char를 사용했으며, 표준가스로는 NO 574 ppm을 2$\ell$/min으로 통과시키면서 2450 MHz의 전자파를 조사했을 경우 95 % 이상 분해 제거가 가능했다. 보다 낮은 농도의 연소배가스에 대해서는 거의 완전한 제거가 가능하므로 대기환경오염방지에 일조할 것으로 기대된다.

  • PDF

Hydrogen production by plasma pyrolysis-gasification of waste (폐기물의 플라즈마 열분해-가스화에 의한 수소생산)

  • Lee, Jin-Ho;Kim, Young-Suk;Do, Chul-Jin;Hwang, Soon-Mo;Jeong, Seong-Jae
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.77-89
    • /
    • 2007
  • 폐기물의 플라즈마를 이용한 열분해-가스화-용융 처리공정은 청정연료 형태로 정화된 합성가스를 얻을 수 있고, 이 합성가스를 WGS 반응과 PSA 공법을 이용하면 고순도 수소로의 전환 및 회수가 가능하다. (주)애드플라텍에서는 자체 보유하고 있는 3톤/일급 플라즈마 폐기물 처리설비와 수소 정제/회수시스템을 연계하여, 페기물로부터 고순도 수소 생산($20Nm^3/h$이상)을 위한 플라즈마 폐기물 처리 추소 생산 통합시스템 개발을 진행하고 있다. 합성가스 내 질소 농도를 낮추기 위해 산소를 매질로 하는 100kw급 산소 플라즈마 토치를 제작하였다. 수소 정제/회수 시스템은 폐기물의 플라즈마 처리 후의 합성가스 생성량과 조성의 변화에 대응할 수 있도록 하였으며, WGS 반응기로 들어가는 합성가스를 가스 컴프레서를 통하여 최대 10기압으로 승압시키고, 고농도 일산화탄소의 효과적인 제거 및 열 회수 극대화가 이루어질 수 있는 최적의 가스처리 시스템으로 구현되도록 하였다. 설치 완료된 WGS 반응기의 성능시험을 플라즈마 처리설비와 연계하여 수행하였다. 합성가스 내 각각 34%와 25%의 일산화탄소 및 수소의 농도가 WGS 반응기를 거친 후, 일산화탄소는 0.1% 미만으로 제거되었으며 수소는 44%로 증가하여 WGS 반응기의 성능 수준이 매우 우수함을 확인하였다. 차기 년도에 설치/가동 예정인 수소 생산용 PSA는 최대 10기압 운전 및 상압재생 방식으로 운전되며 생산된 수소는 최소 99.99%이상의 고순도를 유지할 것으로 기대된다.

  • PDF

Removal of Harmful Gas with Wood or Bark Charcoal (목질 및 수피탄화물에 의한 기상 유해가스 흡착제거)

  • Jo, Tae-Su
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.69-76
    • /
    • 2008
  • To estimate removal ability of harmful gas by charcoal, we carbonized Red oak (Quercus mongolica Fischer) wood and Larch (Larix leptoepis) bark at $300^{\circ}C$, $600^{\circ}C$ and $900^{\circ}C$ for 1 hour. Gas removal ratios was increased with carbonization temperature but there is no difference between wood and bark charcoal. In the case of bad smell and VOC gas, woody charcoal including bark charcoal carbonized at $300^{\circ}C$ showed low removal ratio, less than 50%, whereas woody charcoals which was carbonized at more than $600^{\circ}C$ reached almost 100% removal ratio to bad smell gas such as trimethylamine, methymercaptan, hydrogen sulfide, and to VOC such as benzene, toluene, xylene in $5{\ell}$ tedler bag with each gas of 100 ppm. It was thought that because charcoals carbonized at high temperature, for example, $600^{\circ}C$ or $900^{\circ}C$ have enough specific surface area to adsorb gas of 100 ppm. Moreover these charcoals rapidly removed almost gas in 10 minutes. However, acetylene, $SO_2$ and $NO_2$, charcoals which was carbonized more than $600^{\circ}C$ and which showed high removal ratio had low gas removal ratio of 40% at even 4 hours adsorption. It was concluded that adsorptive ability of woody charcoal was mainly influenced with carbonizing temperature, so that different charcoals carbonized at different temperature brings different gas removal ratio because these charcoals have not only different physical factor such as specific surface area but different chemical characteristic such as functional group, expected.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

반도체 세정 공정용 가스 클러스터 장비의 클러스터 발생 특성 분석

  • Choe, Hu-Mi;Kim, Ho-Jung;Yun, Deok-Ju;Lee, Jong-U;Gang, Bong-Gyun;Kim, Min-Su;Park, Jin-Gu;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.39-39
    • /
    • 2011
  • 반도체 생산의 주요 공정 중 하나인 세정 공정은 공정 중 발생하는 여러 가지 부산물에 의한오염을 효과적으로 제거하여 수율 향상에 큰 영향을 미친다. 현재 주로 쓰이는 세정 공정은 습식 세정 공정으로 화학 약품을 이용하지만 패턴 손상 및 웨이퍼 대구경화에 따른 문제 등이 대두되어 이를 대체할 세정 공정의 도입이 요구되고 있다. 이에 따라 건식 세정에 대한 관심이 증가하고 있으며 에어로졸 세정이 대표적 공정으로 개발 되었으나 마이크로 단위의 발생 에어로졸 입경으로 인해 패턴 손상 문제를 해결하지 못하였다. 이러한 문제점을 극복하기 위하여 응축에 의해 형성되는 입자 크기를 줄이는 것에 관한 연구가 진행되어 왔고, 대응 방안으로 개발된 것이 가스 클러스터 세정이다. 가스 클러스터란 작동 기체의 분자가 수십, 수백 개 뭉쳐있는 형태 (cluster)를 뜻하며 이 때 형성된 클러스터는 수 nm 크기를 가진다. 그리고 짧은 시간의 응축에 의해 수십 nm 크기까지 성장하게 된다. 즉, 입자로 성장할 수 있는 시간과 환경을 형성하지 않음으로써 작은 크기의 클러스터에 의해 패턴 사이의 오염물질을 물리적으로 제거하고 다시 기체상 물질로 환원되어 부산물을 남기지 않는 공정이다. 이러한 작동 환경을 조성하기 위해서는 진공도와 노즐 출구 속도에 대한 설계 단계부터의 이론적 연구를 통한 입자 크기 예측과 세정 조건에 따라서 발생하는 클러스터의 크기 분포 특성을 측정하는 것이 필수적이다. 따라서 본 연구에서는 실시간 저압 환경에서의 측정이 가능하며, 다양한 크기의 입자를 실시간으로 측정할 수 있는 particle beam mass spectrometer (PBMS)를 이용하여 세정 공정 중 발생하는 클러스터의 크기 분포를 측정하는 연구를 수행하였다. 클러스터의 측정은 노즐에 유입되는 유량과 냉매 온도를 변수로 하여 수행하였다. 각각의 조건에 따라서 최빈값은 오차범위 내에서 일정한 것을 확인하였으며, 50 nm 이하의 값으로 가스 클러스터 공정이 패턴 손상 없이 오염입자를 제거할 수 있음을 실험적으로 확인할 수 있었다. 또한 유량의 증가에 따라 세정에 사용되는 클러스터의 입경이 증가하며, 냉매 온도가 낮아질수록 클러스터 입경이 증가하는 경향을 확인할 수 있었다. 클러스터 크기는 오염 입자와의 충돌에 의해 작용하는 힘으로 오염입자를 제거하는 메커니즘을 사용하는 가스 클러스터 세정 장치에 있어 중요성이 크다 할 수 있으며 추후 지속적 연구에 의한 세정 기술의 최적화가 기대된다.

  • PDF

A test of the filtering efficiency of glass fiber filter against atmospheric sulfur gases (글래스 파이버 필터를 이용한 가스상 황화합물들의 여과제거특성 비교연구)

  • Kim, K.H.;Choi, Y.J.
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.65-72
    • /
    • 2006
  • In this study, the filtering characteristics of sulfur gases were investigated from a number of respects. For the purpose of this study, a standard gas containing a single oxidized S ($SO_2$) and five reduced S compounds (RSCs) including $H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS was prepared. After flowing this standard gas through a glass fiber filter, its removal efficiencies were examined by comparing the concentrations between prior to and after its passage. The results indicated that almost complete removal of $SO_2$ was achieved by this filtering, while the patterns for RSCs were distinguished by such factors as molecular weight or reactivity. It was found that about 60% of the most reactive RSC, $H_2S$ was removed by filter, while the heavy RSC generally showed removal rate of about 5% or less.

Study on desulfurization performance of Zn-based solid sorbents at high temperature and pressure in the 0.3 bbl/d CTL(Coal-to-Liquid) process integrated with coal gasifier, F-T process and hot gas desulfurization process (석탄가스화기, F-T 공정, 건식탈황공정이 통합된 0.3 배럴/일 규모 석탄액화(CTL) 공정에서 고온, 고압 연속운전에서 아연계 탈황제의 탈황 성능 파악)

  • Park, Young Cheol;Jo, Sung-Ho;Jin, Gyoung Tae;Lee, Seung-Yong;Yi, Chang-Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.107.2-107.2
    • /
    • 2010
  • 고온건식탈황기술은 고온고압에서 석탄가스에 함유된 황화합물을 제거하는 기술로 석탄가스화에 의해 생성된 고온의 석탄가스의 열손실을 최소화하여 열효율이 높은 기술이다. 본 연구에서는 석탄으로부터 합성원유를 생산하는 0.3 배럴/일 규모 석탄액화(CTL)공정의 연계운전을 통하여 건식탈황공정의 성능을 평가하였다. 0.3 배럴/일 규모 석탄액화공정은 석탄가스화기, 건식탈황공정, 액화공정으로 구성되어 있으며 30 atm의 고압에서 운전된다. 건식탈황공정은 석탄가스화기와 액화공정 사이에 위치하여 석탄가스화로부터 생성된 석탄가스에 함유된 황화합물을 아연계 건식탈황제에 의해 제거한 후 액화반응기로 공급하여 황화합물에 의한 촉매의 피독을 막아주는 역할을 수행한다. 본 연구에서는 기존에 개발된 두 개의 기포유동층 반응기로 구성된 탈황장치를 30 atm에서 운전이 가능하도록 수정/보완하여 실제 운전압력인 30 atm의 고압에서 연속운전을 수행하였다. 실험 결과 탈황효율은 99% 이상이며 탈황반응기 출구 황화합물의 농도는 1 ppmv 이하로 유지하였다.

  • PDF

Effects of steam and $CO_2$ on the methanation of $H_2$-insufficient syngas (수소가 부족한 합성가스의 메탄화반응에서 스팀과 $CO_2$의 영향)

  • Kang, Suk-Hwan;Kim, Jin-Ho;Ryu, Hae-Hong;Yoo, Young-Done;Koh, Dong Jun;Baik, Joon Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.73.2-73.2
    • /
    • 2011
  • 합성천연가스(SNG: Synthetic Natural Gas)를 얻기 위해, 석탄 가스화로부터 얻은 합성가스는 일반적으로 수소와 일산화탄소의 비가 3.0($H_2$/CO)이 되도록 수성가스전환(WGS)반응을 거친 후 메탄화반응기로 유입되며, 가능하면 낮은 온도에서 메탄 전환율이 높은 메탄화 반응의 특성상 강한 발열반응이 수반되므로 이를 낮추는 것이 중요하다. 또한, 최종생성물내의 메탄 농도를 높이기 위해 WGS 이후 탈황과 동시에 이산화탄소를 제거하기 위한 공정이 요구된다. 본 연구에서는 정제된 합성가스의 WGS와 이산화탄소 제거가 생략된 공정을 개발하기 위해, 상업용 촉매에 대하여 수소의 농도가 낮은 합성가스를 이용하여 스팀과 이산화탄소에 대한 메탄화반응 특성을 평가하였다. 또한, 이산화탄소의 존재여부에 따라 스팀으로 메탄화반응과 WGS가 동시에 일어날 수 있는 최적의 운전조건을 얻고자 하였다.

  • PDF