• Title/Summary/Keyword: 가스변압기

Search Result 117, Processing Time 0.034 seconds

UHF Noise leakage characteristics of power transformer (전력용 변압기의 극초단파 대역 외부잡음 유입 특성 측정)

  • Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2031_2032
    • /
    • 2009
  • 가스절연개폐장치(GIS)에 적용하고 있는 극초단파(Ultra High Frequency, UHF) 전자기파 부분방전 측정기술을 전력용 변압기 분야에 적용하는데 외부잡음 유입특성을 고려하여야 한다. 부싱을 통하여 부분방전 신호 이외의 외부잡음의 유입가능성이 크다. 따라서 본 논문에서는 현장에 설치 운전중인 154kV 변압기에 UHF 센서를 설치하여 부싱을 통해 유입되는 외부잡음을 0~2GHz 의 주파수영역에서 측정 하였다.

  • PDF

Performance Simulation of Natural Circulating Cooling System of SF6 Gas Charged Transformer (SF6 가스를 충전한 변압기의 자연순환 냉각시스템의 성능시뮬레이션)

  • Choi, Y.D.;Huh, C.S.;Kim, J.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.54-65
    • /
    • 1994
  • Performance of naturally circulating cooling system of $SF_6$ gas charged transformer was simulated and the variations of gas flow rate, maximum coil temperature, gas temperature and cooling air temperature were investigated with respect to the height of radiator, interplates distance and heat generation rate at core. The results show that the height of radiator most significantly affects the performance of natural circulating cooling system of transformer.

  • PDF

Characteristics of Electric and Mgnetic Field Profiles from Transformer and GIS Perimeters (변압기와 GIS 주변에서 전장과 자장 분포의 특성)

  • 이복희;이승칠;안창환;길형준;장석훈;박동화;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.51-58
    • /
    • 1998
  • This paper deals with the power frequency electric and magnetic profiles from transformer and gas-insulated swichgear(GIS) perimeters in the indoor power substation. Measurements of electric and magnetic field magnitudes were carried out by using single axis and three axes field meters at a height of 1[m]. The resultant electric and magnetic field profiles measured in the vicinity of the transformer were displayed as a 2-dimensional plot. The electric fields intensity are relatively low value of about 2.3~9[V/m], and the magnetic fields intensity range from 0.3 to [$20.3\mu$T]. Also, in the GIS perimeter the electric fields intensity are in the range of 2.2~2.5[V/m], and the high magnetic fields are largely localized to the intermediate section of the GIS and their amplitudes are [$1.2~39.5\mu$T]. Metal enclosures of transform and GIS play a role in reducing the electric field, and the magnetic fields are characterized by a rapid decrease with distance from the transformer and GIS enclosures.

  • PDF

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

Development of Artificial Diagnosis Algorithm for Dissolved Gas Analysis of Power Transformer (전력용 변압기의 유중가스 해석을 위한 지능형 진단 알고리즘 개발)

  • Lim, Jae-Yoon;Lee, Dae-Jong;Lee, Jong-Pil;Ji, Pyeong-Shik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.75-83
    • /
    • 2007
  • IEC code based decision nile have been widely applied to detect incipient faults in power transformers. However, this method has a drawback to achieve the diagnosis with accuracy without experienced experts. In order to resolve this problem, we propose an artificial diagnosis algorithm to detect faults of power transformers using Self-Organizing Feature Map(SOM). The proposed method has two stages such as model construction and diagnostic procedure. First, faulty model is constructed by feature maps obtained by unsupervised learning for training data. And then, diagnosis is performed by compare feature map with it obtained for test data. Also the proposed method usぉms the possibility and degree of aging as well as the fault occurred in transformer by clustering and distance measure schemes. To demonstrate the validity of proposed method, various experiments are unformed and their results are presented.

Application of Water Mist System for a Power Transformer Room - Fire Extinguishment(Part 1) (변압기실 화재에 대한 미분무수 소화시스템의 적용 - 소화특성을 중심으로(Part 1))

  • Han Yong-Shik;Choi Byung-Il;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.32-36
    • /
    • 2005
  • A water mist system was considered as a possible alternative to a gaseous suppression system that can not prevent re-ignition after fire extinguishment for a power transformer room. This study deals with the fire suppression capability of the water mist systems. High-and low-pressure water mist systems were examined to compare efficiency of both systems. The power transformer examined in this study occupied about $7\%$ of a $10m\times10m\times$ transformer room. Full-scale suppression tests were performed for six different fire scenarios: two spray fires, three pool fires and one cascade fire. The fire suppression test results demonstrated that the high-pressure system was superior to the low-pressure system, especially considering oxygen depletion and the ambient temperature distribution.

High-Voltage Pulsed Power Modulator based on single IGBT switch with Fast-Rising Time (빠른 상승률 갖는 단일 IGBT 스위치 기반 고전압 펄스 파워 모듈레이터)

  • Liu, Chang-yu;Cho, Chan-Gi;Song, Seung-Ho;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.46-48
    • /
    • 2019
  • 본 논문은 Discontinuous Conduction Mode(DCM) 플라이백 컨버터로 생성한 고전압 펄스를 스파크 갭으로 펄스 상승 시간을 줄이는 방법에 관하여 다룬다. 이러한 방법으로 생성된 빠른 상승률 특성을 가지는 고전압 펄스 전원장치는 친환경 가스 처리 분야에 사용할 수 있다. 기존 스태킹 구조의 펄스 전원 장치는 많은 수의 스위치들과 에너지 저장 소자가 필요하므로 부피가 커지고 제조 단가가 증가하는 반면, 분 논문에 제안된 전원 장치는 구조를 단순화하여 전체 시스템의 소형화 및 제조 단가를 낮춘 점을 특징으로 한다. 제안된 설계 토폴로지는 플라이백 변압기 2차 측에 다이오드의 사용 유무에 따라 두 개의 변형된 회로로 응용 가능 하다. 변압기 2차측에 다이오드를 사용하면, 음의 성분 없이 깨끗한 고전압 출력 펄스를 만들 수 있지만 사용한 다이오드의 전압 정격을 고려해야 한다. 다이오드를 사용하지 않는다면, 고전압 출력 펄스에 음의 성분이 발생하지만 비용과 부피를 최대한 줄일 수 있다. PSIM 시뮬레이션을 사용하여 제안하는 전원 장치의 23kV, 0.5 ㎲, 10 ns rising time의 출력 펄스 발생 성능을 검증하고, 다이오드 사용에 따른 출력 펄스의 차이점을 비교하였다.

  • PDF

Permeability Study of Membranes for Separation $H_2$ in Oil (가스센서를 이용한 변압기 절연유중 가스 검출장치의 수소 가스 감지 특성에 관한 연구)

  • Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1845-1847
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the future.

  • PDF

Electrical characteristics of PET film for wire insulation of transformer in fluorocarbon (Fluorocarbon에서의 변압기권선 절연용 PET필름의 전기적 특성연구)

  • 허창수;이재복
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.483-489
    • /
    • 1996
  • Power transformer have many unsymmetrical structure and electric field is enhanced in that area. Those unsymmetrical area are not covered oftenly by solid insulating material which is used as a framework specially in gas transformer. By that result there is a possibility to decrease the total insulation class of the transformer. So in this study the electrical characteristic of $FC+SF_6$ mixture gas which is used as coolants for large power gas insulated transformer and its effects on electrical characteristics of structural material are investigated. Also breakdown characteristic with the tension of taping and curvature of the coil are studied which could be used as a design factor of large power transformer.

  • PDF