• Title/Summary/Keyword: 가속효과

Search Result 596, Processing Time 0.028 seconds

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

Effects of Limestone Powder and Silica Fume on the Hydration and Pozzolanic Reaction of High-Strength High-Volume GGBFS Blended Cement Mortars (고강도 고함량 고로슬래그 혼합 시멘트 모르터의 수화 및 포졸란 반응에 미치는 석회석 미분말과 실리카퓸의 영향)

  • Jeong, Ji-Yong;Jang, Seung-Yup;Choi, Young-Cheol;Jung, Sang-Hwa;Kim, Sung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • To evaluate the effects of limestone powder and silica fume on the properties of high-strength high-volume ground granulated blast-furnace slag (GGBFS) blended cement concrete, this study investigated the rheology, strength development, hydration and pozzolanic reaction characteristics, porosity and pore size distribution of high-strength mortars with the water-to-binder ratio of 20, 50 to 80% GGBFS, up to 20% limestone powder, and up to 10% silica fume. According to test results, compared with the Portland cement mixture, the high-volume GGBFS mixture had much higher flow due to the low surface friction of GGBFS particles and higher strength in the early age due to the accelerated cement hydration by increase of free water; however, because of too low water-to-binder ratio and cement content, and lack of calcium hydroxide content, the pozzolanic reactio cannot be activated and the long-term strength development was limited. Limestone powder did not affect the flowability, and also accelerate the early cement hydration. However, because its effect on the acceleration of cement hydration is not greater than that of GGBFS, and it does not have hydraulic reactivity unlikely to GGBFS, compressive strength was reduced proportional to the replacement ratio of limestone powder. Also, silica fume and very fine GGBFS lowered flow and strength by absorbing more free water required for cement hydration. Capillary porosities of GGBFS blended mortars were smaller than that of OPC mortar, but the effect of limestone powder on porosity was not noticeable, and silica fume increased porosity due to low degree of hydration. Nevertheless, it is confirmed that the addition of GGBFS and silica fume increases fine pores.

Characteristics of Aerodynamic Damping on Helical-Shaped Super Tall Building (나선형 형상의 초고층건물의 공력감쇠의 특성)

  • Kim, Wonsul;Yi, Jin-Hak;Tamura, Yukio
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Characteristics of aerodynamic damping ratios of a helical $180^{\circ}$ model which shows better aerodynamic behavior in both along-wind and across-wind responses on a super tall building was investigated by an aeroelastic model test. The aerodynamic damping ratio was evaluated from the wind-induced responses of the model by using Random Decrement (RD) technique. Further, various triggering levels in evaluation of aerodynamic damping ratios using RD technique were also examined. As a result, it was found that when at least 2000 segments were used for evaluating aerodynamic damping ratio for ensemble averaging, the aerodynamic damping ratio can be obtained more consistently with lower irregular fluctuations. This is good agreement with those of previous studies. Another notable observation was that for square and helical $180^{\circ}$ models, the aerodynamic damping ratios in along-wind direction showed similar linear trends with reduced wind speeds regarding of building shapes. On the other hand, for the helical $180^{\circ}$ model, the aerodynamic damping ratio in across-wind direction showed quite different trends with those of the square model. In addition, the aerodynamic damping ratios of the helical $180^{\circ}$ model showed very similar trends with respect to the change of wind direction, and showed gradually increasing trends having small fluctuations with reduced wind speeds. Another observation was that in definition of triggering levels in RD technique on aerodynamic damping ratios, it may be possible to adopt the triggering levels of "standard deviation" or "${\sqrt{2}}$ times of the standard deviation" of the response time history if RD functions have a large number of triggering points. Further, these triggering levels may result in similar values and distributions with reduced wind speeds and either may be acceptable.

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

The Role of Pelvic Irradiation after Hysterectomy in Early Stage Cervical Carcinoma with Pelvic Nodal Metastasis (림프절 전이를 동반한 초기 자궁경부암에서 수술 후 방사선치료의 역할)

  • Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.469-475
    • /
    • 1998
  • Purpose : To determine the role of Pelvic irradiation in stage I or IIA cervical carcinoma with pelvic nodal metastasis after hysterectomy and bilateral pelvic lymphadenectomy. Materials and Methods : This is a retrospective study of 68 cervical carcinoma patients who were found to have pelvic nodal metastasis at hysterectomy and received pelvic irradiation from 1983 to 1996 at Inje University Seoul Paik Hospital. External beam radiation therapy to pelvis was delivered using 4 MeV Linac and intracavitary irradiation was given via vaginal ovoids or cylinders. Five-year survival and disease-free survival were estimated by Kaplan-Meier Method and prognostic factors related to survival were analysed by log-rank test and Cox proportional hazards regression model. Results : Median length of follow-up was 52months. Five-year overall survival and disease-free survival (DFS) were 81.8$\%$ and 81.7$\%$ respectively. Patients with endometrial invasion had a 57.1$\%$ 5-year DFS compared to 87.5$\%$ for those without endometrial invasion (p=0.0074). Multivariate analysis revealed endometrial invasion as an only statistically significant prognostic factor for 5-year DFS. Among total 15 (22$\%$) recurrences. pelvic recurrences occurred in 4 cases and distant metastases occurred in 13 cases. Conclusion : We have been able to confirm previous results demonstrating marked decrease in local recurrence after pelvic irradiation. In view of the high proportion of distant metastasis found in this study, a trial of aggressive adjuvant systemic therapy and irradiation in early stage cervical carcinoma patients with pelvic nodal metastasis, especially with endometrial invasion, appears to be warranted.

  • PDF

Life-time Prediction of a FKM O-ring using Intermittent Compression Stress Relaxation (CSR) and Time-temperature Superposition (TTS) Principle (간헐 압축응력 완화와 시간-온도 중첩 원리를 이용한 FKM 오링의 수명 예측 연구)

  • Lee, Jin-Hyok;Bae, Jong-Woo;Kim, Jung-Su;Hwang, Tae-Jun;Park, Sung-Doo;Park, Sung-Han;Min, Yeo-Tae;Kim, Won-Ho;Jo, Nam-Ju
    • Elastomers and Composites
    • /
    • v.45 no.4
    • /
    • pp.263-271
    • /
    • 2010
  • Intermittent CSR testing was used to investigate the degradation of an FKM O-ring, also the prediction of its life-time. An intermittent CSR jig was designed taking into consideration the O-ring's environment under use. The testing allowed observation of the effects of friction, heat loss, and stress relaxation by the Mullins effect. Degradation of O-rings by thermal aging was observed between 60 and $160^{\circ}C$. In the high temperature of range ($100-160^{\circ}C$) O-rings showed linear degradation behavior and satisfied the Arrhenius relationship. The activation energy was about 60.2 kJ/mol. From Arrhenius plots, predicted life-times were 43.3 years and 69.9 years for 50% and 40% failure conditions, respectively. Based on TTS (time-temperature superposition) principle, degradation was observed at $60^{\circ}C$, and could save testing time. Between 60 and $100^{\circ}C$ the activation energy decreased to 48.3 kJ/mol. WLF(William-Landel-Ferry) plot confirmed that O-rings show non-linear degradation behavior under $80^{\circ}C$. The life-time of O-rings predicted by TTS principle was 19.1 years and 25.2 years for each failure condition. The life-time predicted by TTS principle is more conservative than that from the Arrhenius relationship.

Investigation of Viscoelastic Properties of EPDM/PP Thermoplastic Vulcanizates for Reducing Innerbelt Weatherstrip Squeak Noise of Electric Vehicles (전기차 인너벨트 웨더스트립용 EPDM/PP Thermoplastic Vulcanizates 재료설계인자에 따른 점탄성과 글라스 마찰 소음 상관관계 연구)

  • Cho, Seunghyun;Yoon, Bumyong;Lee, Sanghyun;Hong, Kyoung Min;Lee, Sang Hyun;Suhr, Jonghwan
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.192-198
    • /
    • 2021
  • Due to enormous market growing of electric vehicles without combustion engine, reducing unwanted BSR (buzz, squeak, and rattle) noise is highly demanded for vehicle quality and performance. Particularly, innerbelt weatherstrips which not only block wind noise, rain, and dust from outside, but also reduce noise and vibration of door glass and vehicle are required to exhibit high damping properties for improved BSR performance of the vehicle. Thermoplastic elastomers (TPEs), which can be recycled and have lighter weight than thermoset elastomers, are receiving much attention for weatherstrip material, but TPEs exhibit low material damping and compression set causing frictional noise and vibration between the door glass and the weatherstrip. In this study, high damping EPDM (ethylene-propylene-diene monomer)/PP (polypropylene) thermoplastic vulcanizates (TPV) were investigated by varying EPDM/PP ratio and ENB (ethylidene norbornene) fraction in EPDM. Viscoelastic properties of TPV materials were characterized by assuming that the material damping is directly related to the viscoelasticity. The optimum material damping factor (tanδ peak 0.611) was achieved with low PP ratio (14 wt%) and high ENB fraction (8.9 wt%), which was increased by 140% compared to the reference (tanδ 0.254). The improved damping is believed due to high fraction of flexible EPDM chains and higher interfacial slippage area of EPDM particles generated by increasing ENB fraction in EPDM. The stick-slip test was conducted to characterize frictional noise and vibration of the TPV weatherstrip. With improved TPV material damping, the acceleration peak of frictional vibration decreased by about 57.9%. This finding can not only improve BSR performance of electric vehicles by designing material damping of weatherstrips but also contribute to various structural applications such as urban air mobility or aircrafts, which require lightweight and high damping properties.

Evaluation of the usefulness of Halcyon VMAT treatment plan through comparison with tomotherapy in bilateral breast cancer radiation therapy. (양측 유방암 방사선치료 시 토모테라피와의 비교를 통한 Halcyon VMAT 치료계획의 유용성 평가)

  • LIM JUN TAEK;PARK JU YOUNG;PARK SU YEON;JEON SEONG JIN;PARK TAE YANG;HWANG DA JIN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.83-92
    • /
    • 2022
  • Purpose: To evaluate usefulness of Tomotherapy and Halcyon VMAT treatment in radiation therapy for bi-breast cancer Materials and Methods: For 10 patients with bi-breast cancer, volumetric modulated arc therapy(VMAT) treatment plan was established using helical Tomotherapy(Accuray. USA) with field width of 5.0-cm and pitch of 0.287, and Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA) of 6arc and 8arc. Prescribed dose was 42.4 Gy/16, and V 40.3Gy of Planning Target Volume(PTV) was 90%. The quality of plan was evaluated by comparing the dose to tumor and normal organs, and the efficiency was evaluated by comparing total MU and beam on time. Results: About three treatment plans(Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT) , the mean homogeneity index(H.I) of PTV were 1.07, 1.10, 1.11, and the mean conformity index(C.I) of PTV were 1.21, 1.16, 1.17, respectively. The average value of the dose assessment item for a normal organ is V 5Gy(%) of both lung was 36.3, 31.2, 29.7, and V 15Gy(%) were 18.6, 15.5, 14.6, respectively. The mean heart dose(Gy) were 4.17, 2.69, 2.51. Total MU were (7498.6, 2494.2, 2471.5), and beam on time(sec) were 462.5, 195.4, 198.0. Conclusion: Halcyon VMAT showed similar quality of treatment plan compared to helical Tomotherapy, while also protecting normal organs. In addition, the efficiency of radiotherapy increased due to a decrease in Beam On Time and MU.

Feasibility study of using Halcyon LINAC for Double-target spine stereotactic body radiation therapy (이중 표적 척추 전이암의 체부정위방사선치료 시 Halcyon LINAC의 치료 유용성 평가)

  • Jeong Hee Ju;An Ye Chan;Park Byung Suk;Park Myung Hwan;Park Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.51-60
    • /
    • 2022
  • Objectives: The purpose is to evaluate dosimetric performance and delivery efficiency of VMAT with Halcyon LINAC for double target spine SBRT Materials and Methods: 12 patients with spine oligometastases were retrospectively studied. Single-isocenter spine SBRT plans was established using Halcyon® with Dual Layer MLC and Truebeam® with High Definition MLC. All patients' plans were created in Eclipse TPS through the identical conditions and optimization. C.I, H.I, G.I (Gradient Index), maximal and volumetric doses to spinal cord and low dose area were evaluated for comparison of both plans. Also, total MU and BOT(Beam On Time) were evaluated. Results: Halcyon plans was no Statistical differences in C.I and H.I. However, the average of G.I was 4.64 for Halcyon, which decreased to 5.5% compared to Truebeam (P<0.001). Halcyon plans demonstrated statistically significant reduced G.I. The average of 50% and 25% isodose volume was 487.56 cc (-3.82%, P<0.001), 1859.45 cc (-4.75%, P<0.001) in Halcyon, respectively. Significantly reduced low dose spill were observed in Halcyon plans. In the evaluation of the spinal cord, the average of Dmean and V10 of Halcyon plans in the sample group with an overlap volume of less than 1 cc was 6.802 Gy (-3.504%, P=0.067), 5.766±1.683 cc (-8.199%, P=0.002), respectively. Halcyon plans demonstrated statistically significant reduced Dmean and V10. For delivery efficiency, MU and BOT(maximum dose rate for each machine), on average, increased in Halcyon plans. However, the average of BOT(800MU/min for each machine) was 648.33 sec for Halcyon (-1.74%, P<0.001). Conclusion: Halcyon plan for double-target spine SBRT demonstrated advantages in the low dose area with a steep dose gradient, while having dosimetrically equivalent target dose distribution and spinal cord protective effect. As a result, Halcyon LINAC produced a dosimetrically improved plan for double-target spine SBRT.

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.