• Title/Summary/Keyword: 가속효과

Search Result 595, Processing Time 0.027 seconds

The Change of Anthocyanin and Spreadmeter Value of Strawberry Jam by Heating and Preservation (딸기잼의 안토시아닌과 Spreadmeter치의 가열 및 저장중 변화)

  • Park, Sung-Jun;Lee, Jae-Ha;Rhim, Jae-Ho;Kwon, Kyung-Sup;Jang, Hee-Gyu;Yu, Mu-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.365-369
    • /
    • 1994
  • In attempt to explain the effect of heat processing on the product quality in manufacturing strawberry jam, the heat stability of anthocyanin in strawberry by addition of some sweetners was studied, and the effect of sucrose by concentration and pH were also investigated. The heat stability of anthocyanin was maximum at pH 2.5 when maintaining at $87^{\circ}C$ for 60 minutes initially, but it was shifted to pH 3.0 after additional heating of 120 minutes. When the corn syrup, sucrose and glucose were used as a sweetner for manufacturing strawberry jam, the results showed that heat stability of anthocyanin in corn syrup was higher than that in sucrose and fructose, and the optimum concentration of sucrose for heat stability was 66 Brix%. The results also showed that anthocyanin content in strawberry jam significantly decreased logarithmically at $37^{\circ}C$, and spreadmeter value changed slightly at $37^{\circ}C$storage but it was not significant.

  • PDF

Implementation of Gait Analysis System Based on Inertial Sensors (관성센서 기반 보행 분석 시스템 구현)

  • Cho, J.S.;Kang, S.I.;Lee, K.H.;Jang, S.H.;Kim, I.Y.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait analysis system to measure and analyze lower-limb movements. We developed an integral AHRS(Attitude Heading Reference System) using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE(Root Mean Square Error) of 1.08 and 1.72 degree in yaw and pitch angle. In order to evaluate the performance of our the gait analysis system, we compared the joint angle for the hip, knee and ankle with those provided by Vicon system. The result shows that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limb or gait analysis during the post-stroke recovery.

  • PDF

Safety Evaluation of Concert Hall Floor Vibration Using Numerical Analysis Model (수치해석모델을 이용한 콘서트 홀 바닥진동 안전성 평가)

  • Roh, Ji-Eun;Heo, Seok-Jae;Moon, Dae-Ho;Lee, Sang-Hyun;Rha, Chang-Soon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.469-477
    • /
    • 2017
  • In this paper, the floor vibration of an example concert hall building was measured and floor safety criteria were analytically checked through comparison between experimental and analytical results. The floor bottom plate model was constructed considering the composite effect and the analytical model was modified to have the natural frequency identical to the measured one. Also, time history analysis was conducted using the dynamic loads induced by human rhythmic movement during a musical performance, and the analytically calculated floor accelerations were similar to the measured one. Based on this model, the floor vibration level due to the group activities of about 400 persons, maximum available persons for the concert hall, was estimated. It was confirmed that the human induced dynamic loads applied to the column and beam would be much lower than the design strength. In addition, the horizontal acceleration level is just 2% of the design seismic load, so the concert hall is safe in both vertical and horizontal excitations by human rhythmic movements.

A probabilistic fragility evaluation method of a RC box tunnel subjected to earthquake loadings (지진하중을 받는 RC 박스터널의 확률론적 취약도 평가기법)

  • Huh, Jungwon;Le, Thai Son;Kang, Choonghyun;Kwak, Kiseok;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.143-159
    • /
    • 2017
  • A probabilistic fragility assessment procedure is developed in this paper to predict risks of damage arising from seismic loading to the two-cell RC box tunnel. Especially, the paper focuses on establishing a simplified methodology to derive fragility curves which are an indispensable ingredient of seismic fragility assessment. In consideration of soil-structure interaction (SSI) effect, the ground response acceleration method for buried structure (GRAMBS) is used in the proposed approach to estimate the dynamic response behavior of the structures. In addition, the damage states of tunnels are identified by conducting the pushover analyses and Latin Hypercube sampling (LHS) technique is employed to consider the uncertainties associated with design variables. To illustrate the concepts described, a numerical analysis is conducted and fragility curves are developed for a large set of artificially generated ground motions satisfying a design spectrum. The seismic fragility curves are represented by two-parameter lognormal distribution function and its two parameters, namely the median and log-standard deviation, are estimated using the maximum likelihood estimates (MLE) method.

A Study on the Reduction of Organ Motion from Respiration (호흡 운동에 의한 내부 장기의 움직임 감소에 관한 연구)

  • Kim Jae-Gyoun;Lee Dong-Han;Lee Dong-Hoon;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Oh Won-Yong;Ji Young-Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.179-185
    • /
    • 2004
  • To deal with tumor motion from respiration is one of the important issues for the advanced treatment techniques, such as the intensity modulated radiation therapy (IMRT), the image guided radiation therapy (IGRT), the three dimensional conformal therapy (3D-CRT) and the Cyber Knife. Studies including the active breath control (ABC) and the gated radiation therapy have been reported. Authors have developed the device for reducing the respiration effects and the diaphragm motions with this device were observed to determined the effectiveness of the device. The device consists of four belts to immobilize diaphragm motion and the vacuum cushion. Diaphragm motions without and with device were monitored fluoroscopically. Diaphragm motion ranges were found to be 1.14 ~ 3.14 cm (average 2.14 cm) without the device and 0.72~1.95 cm (average 1.16 cm) with the device. The motion ranges were decreased 20 ~ 68.4% (average 44.9%.) However, the respiration cycle was increased from 4.4 seconds to 3.7 seconds. The CTV-PTV margin could be decreased significantly with the device developed in this study, which may be applied to the treatments of the tumor sited diaphragm region.

  • PDF

Advanced Lane Change Assist System for Automatic Vehicle Control in Merging Sections : An algorithm for Optimal Lane Change Start Point Positioning (고속도로 합류구간 첨단 차로변경 보조 시스템 개발 : 최적 차로변경 시작 지점 Positioning 알고리즘)

  • Kim, Jinsoo;Jeong, Jin-han;You, Sung-Hyun;Park, Janhg-Hyon;Young, Jhang-Kyung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.3
    • /
    • pp.9-23
    • /
    • 2015
  • A lane change maneuver which has a high driver cognitive workload and skills sometimes leads to severe traffic accidents. In this study, the Advanced Lane Change Assist System (ALCAS) was developed to assist with the automatic lane changes in merging sections which is mainly based on an automatic control algorithm for detecting an available gap, determining the Optimal Lane Change Start Point (OLCSP) in various traffic conditions, and positioning the merging vehicle at the OLCSP safely by longitudinal automatic controlling. The analysis of lane change behavior and modeling of fundamental lane change feature were performed for determining the default parameters and the boundary conditions of the algorithm. The algorithm was composed of six steps with closed-loop. In order to confirm the algorithm performance, numerical scenario tests were performed in various surrounding vehicles conditions. Moreover, feasibility of the developed system was verified in microscopic traffic simulation(VISSIM 5.3 version). The results showed that merging vehicles using the system had a tendency to find the OLCSP readily and precisely, so improved merging performance was observed when the system was applied. The system is also effective even during increases in vehicle volume of the mainline.

Acceleration of Anisotropic Elastic Reverse-time Migration with GPUs (GPU를 이용한 이방성 탄성 거꿀 참반사 보정의 계산가속)

  • Choi, Hyungwook;Seol, Soon Jee;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.2
    • /
    • pp.74-84
    • /
    • 2015
  • To yield physically meaningful images through elastic reverse-time migration, the wavefield separation which extracts P- and S-waves from reconstructed vector wavefields by using elastic wave equation is prerequisite. For expanding the application of the elastic reverse-time migration to anisotropic media, not only the anisotropic modelling algorithm but also the anisotropic wavefield separation is essential. The anisotropic wavefield separation which uses pseudo-derivative filters determined according to vertical velocities and anisotropic parameters of elastic media differs from the Helmholtz decomposition which is conventionally used for the isotropic wavefield separation. Since applying these pseudo-derivative filter consumes high computational costs, we have developed the efficient anisotropic wavefield separation algorithm which has capability of parallel computing by using GPUs (Graphic Processing Units). In addition, the highly efficient anisotropic elastic reverse-time migration algorithm using MPI (Message-Passing Interface) and incorporating the developed anisotropic wavefield separation algorithm with GPUs has been developed. To verify the efficiency and the validity of the developed anisotropic elastic reverse-time migration algorithm, a VTI elastic model based on Marmousi-II was built. A synthetic multicomponent seismic data set was created using this VTI elastic model. The computational speed of migration was dramatically enhanced by using GPUs and MPI and the accuracy of image was also improved because of the adoption of the anisotropic wavefield separation.

Influence on the Understanding of the Gas Particles Behavior Concepts in 'Thinking Science' Activities of Middle School Students and Recognition on Its Activities ('생각하는 과학' 활동이 중학생들의 기체 분자 운동 개념의 이해에 미치는 영향과 그 활동에 대한 인식)

  • Lee, Sang Kwon;Kim, Seon-Young
    • Journal of Science Education
    • /
    • v.35 no.1
    • /
    • pp.68-79
    • /
    • 2011
  • The purpose of this study was to investigate the recognition of middle school students on 'Thinking Science' activities and the influence on the understanding of the gas particles behavior concepts. For this study 125 students of four classes first grade in middle school were divided into two groups, the experimental and the control group. The SRT II test was carried out to identify the cognitive level of the students. The logical factors, needed to understand of the gas particles behavior concepts, were extracted. And the 9 'Thinking Science' activities designed to develop these factors were chosen and then implemented to the students of the experimental group. After the lesson for the gas particles behaviors, the achievement test of understanding of the gas particles behavior concepts and the survey of the students' recognition on 'Thinking Science' activities were administered. According to the results of the achievement test, there was not significant difference between the two groups on the whole. But only mature concrete operational students in the experimental group got high scores than those in the control group in analyzing the effect size. According to the results of the ANCOVA analysis, there was significant difference between the two girls' group. When students in the experimental group had a positive perceptions about 'Thinking Science' activities, they got higher achievement scores. This implied that there was a correlation between perception about 'Thinking Science' activities and their achievement in the gas particles behavior concepts. Especially, students with positive perception in mature concrete operational period got higher scores in science achievement. After the 'Thinking Science' activities, there was a high perceptions about improving in scientific thinking.

  • PDF

Daily check device manufacture and efficiency Evaluation for daily Q.A (일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가)

  • Kim Chan Yong;Je Yeong Wan;Lee Je Hui;Park Heung Deuk
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • Introduction: Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Methods and Materials: Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment, field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Result: We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}\;2\%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}\;1mm$. Conclusion: We can enforce output measurement and appliances check conveniently and time was reduced and was able to raise efficiency of business. We were able to bring n cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

An Enhanced Step Detection Algorithm with Threshold Function under Low Sampling Rate (낮은 샘플링 주파수에서 임계 함수를 사용한 개선된 걸음 검출 알고리즘)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.57-64
    • /
    • 2015
  • At the case of peak threshold algorithm, 3-axes data should sample step data over 20 Hz to get sufficient accuracy. But most of the digital sensors like 3-axes accelerometer have very low sampling rate caused by low data communication speed on limited SPI or $I^2C$ bandwidth of the low-cost MPU for ubiquitous devices. If the data transfer rate of the 3-axes accelerometer is getting slow, the sampling rate also slows down and it finally degrades the data accuracy. In this study, we proved there is a distinct functional relation between the sampling rate and threshold on the peak threshold step detection algorithm under the 20Hz frequency, and made a threshold function through the experiments. As a result of experiments, when we apply threshold value from the threshold function instead of fixed threshold value, the step detection error rate can be lessen about 1.2% or under. Therefore, we can suggest a peak threshold based new step detection algorithm with threshold function and it can enhance the accuracy of step detection and step count. This algorithm not only can be applied on a digital step counter design, but also can be adopted any other low-cost ubiquitous sensor devices subjected on low sampling rate.