• Title/Summary/Keyword: 가속차로

Search Result 377, Processing Time 0.026 seconds

A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV (15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.481-487
    • /
    • 2023
  • In this study, we analyzed the incidence of side effects of photoneutron dose according to the number of beams during intensity-modulated radiotherapy of prostate cancer using 15 MV. The radiation treatment plan design for intensity-modulated radiation therapy for prostate cancer was established with a prescription dose of 220 cGy per dose and a total of 7260 cGy for 33 treatments. The linear accelerator used in the experiment is Varian's True Beam STx (Varian, USA). Photoneutron dose was generated by using 15 MV energy in the planning target volume (PTV). The treatment plan was designed with IMRT 5, 7, and 9 portals using the Eclipse System (Varian Ver 10.0, USA). An optically stimulated luminescence albedo neutron dosimeter (Landauer Inc., USA) was used to measure photoneutron dose. IMRT 5 portals, 1.7 per 1,000, 7 portals, 1.8 per 1,000, 9 portals, 2.0 per 1,000 were calculated as the probability of experiencing side effects on the thyroid gland due to photoneutron dose. This study studies the risk of secondary radiation exposure dose that can occur during intensity-modulated radiation therapy, and it is considered that it will be used as useful data in relation to stochastic effects in the future.

Comprehensive Understanding about Drop-Out Adolescents in Korea (우리나라 학업중단청소년에 대한 이해)

  • Myoung-Ja Keum
    • Korean Journal of Culture and Social Issue
    • /
    • v.14 no.1_spc
    • /
    • pp.299-317
    • /
    • 2008
  • The school drop-out among the youth has grown to become a serious social problem since about 2000 and calls for an attention to its seriousness. Therefore, this study reviewed the statitistical reports and the previous empirical findings on the school drop-out and integrated to establish a comprehensive understanding of this social phenomenon. The main concepts and terminologies on school drop-out, the current statistics, the possible causal factors and the usual trajectory the youth take after dropping-out of school were discussed to conceptualize the issue. Analyses indicated 12 characteristics of the students who dropped out of school. Those 12 characteristics were restructured according to the ecological conceptual model. The social instability and the financial crisis in the 1990's has eroded the stability of the primary environments of adolescents such as family and school. The family breakdowns from divorce and other reasons weakened psychological and financial support for adolescents. The diminished authority of teachers and school over students exposed conflicts between teacher and students, students' loss of purpose and interest in academic attainment. The adolescents showed emotional reponses like increased level of depression, helplessness, aggression, indicated cognitive reponses such as the loss of purpose and interest in studying, a heightened sense of uncertainty of the future, and behavioral responses like sexual acting out behaviors, and bullying. The unmet psychological needs of adolescents result in run-away and school drop-out behaviors, which in turn progress into juvenile delinquency as the society fails to provide adequate and appropriate guidance and interventions. The intervention strategies at the national level were proposed and the limitations of the study were discussed.

  • PDF

Change Analysis of Aboveground Forest Carbon Stocks According to the Land Cover Change Using Multi-Temporal Landsat TM Images and Machine Learning Algorithms (다시기 Landsat TM 영상과 기계학습을 이용한 토지피복변화에 따른 산림탄소저장량 변화 분석)

  • LEE, Jung-Hee;IM, Jung-Ho;KIM, Kyoung-Min;HEO, Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.4
    • /
    • pp.81-99
    • /
    • 2015
  • The acceleration of global warming has required better understanding of carbon cycles over local and regional areas such as the Korean peninsula. Since forests serve as a carbon sink, which stores a large amount of terrestrial carbon, there has been a demand to accurately estimate such forest carbon sequestration. In Korea, the National Forest Inventory(NFI) has been used to estimate the forest carbon stocks based on the amount of growing stocks per hectare measured at sampled location. However, as such data are based on point(i.e., plot) measurements, it is difficult to identify spatial distribution of forest carbon stocks. This study focuses on urban areas, which have limited number of NFI samples and have shown rapid land cover change, to estimate grid-based forest carbon stocks based on UNFCCC Approach 3 and Tier 3. Land cover change and forest carbon stocks were estimated using Landsat 5 TM data acquired in 1991, 1992, 2010, and 2011, high resolution airborne images, and the 3rd, 5th~6th NFI data. Machine learning techniques(i.e., random forest and support vector machines/regression) were used for land cover change classification and forest carbon stock estimation. Forest carbon stocks were estimated using reflectance, band ratios, vegetation indices, and topographical indices. Results showed that 33.23tonC/ha of carbon was sequestrated on the unchanged forest areas between 1991 and 2010, while 36.83 tonC/ha of carbon was sequestrated on the areas changed from other land-use types to forests. A total of 7.35 tonC/ha of carbon was released on the areas changed from forests to other land-use types. This study was a good chance to understand the quantitative forest carbon stock change according to the land cover change. Moreover the result of this study can contribute to the effective forest management.

Analysis of dosimetric leaf gap variation on dose rate variation for dynamic IMRT (동적 세기조절방사선 치료 시 선량률 변화에 따른 선량학적엽간격 변화 분석)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.47-55
    • /
    • 2016
  • To evaluate the position accuracy of the MLC. This study analyzed the variations of the dosimetric leaf gap(DLG) and MLC transmission factor to reflect the location of the MLC leaves according to the dose rate variation for dynamic IMRT. We used the 6 MV and 10 MV X-ray beams from linear accelerator with a Millennium 120 MLC system. We measured the variation of DLG and MLC transmission factor at depth of 10 cm for the water phantom by varying the dose rate to 200, 300, 400, 500 and 600 MU/min using the CC13 and FC-65G chambers. For 6 MV X-ray beam, a result of measuring based on a dose rate 400 MU/min by varying the dose rate to 200, 300, 400, 500 and 600 MU/min of the difference rate was respectively -2.59, -1.89, 0.00, -0.58, -2.89%. For 10 MV X-ray beam, the difference rate was respectively ?2.52, -1.69, 0.00, +1.28, -1.98%. The difference rate of MLC transmission factor was in the range of about ${\pm}1%$ of the measured values at the two types of energy and all of the dose rates. This study evaluated the variation of DLG and MLC transmission factor for the dose rate variation for dynamic IMRT. The difference of the MLC transmission factor according to the dose rate variation is negligible, but, the difference of the DLG was found to be large. Therefore, when randomly changing the dose rate dynamic IMRT, it may significantly affect the dose delivered to the tumor. Unless you change the dose rate during dynamic IMRT, it is thought that is to be the more accurate radiation therapy.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Study on Computerized Treatment Plan of Field-in-Field Intensity Modulated Radiation Therapy and Conventional Radiation Therapy according to PBC Algorithm and AAA on Breast Cancer Tangential Beam (유방암 접선조사에서 PBC 알고리즘과 AAA에 따른 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy 전산화 치료계획에 대한 고찰)

  • Yeom, Mi-Suk;Bae, Seong-Soo;Kim, Dae-Sup;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.11-14
    • /
    • 2012
  • Purpose: Anisotropic Analytical Algorithm (AAA) provides more accurate dose calculation regarding impact on scatter and tissue inhomogeneity in comparison to Pencil Beam Convolution (PBC) algorithm. This study tries to analyze the difference of dose distribution according to PBC algorithm and dose calculation algorithm of AAA on breast cancer tangential plan. Materials and Methods: Computerized medical care plan using Eclipse treatment planning system (version 8.9, VARIAN, USA) has been established for the 10 breast cancer patients using 6 MV energy of Linac (CL-6EX, VARIAN, USA). After treatment plan of Conventional Radiation Therapy plan (Conventional plan) and Field-in-Field Intensity Modulated Radiation Therapy plan (FiF plan) using PBC algorithm has been established, MU has been fixed, implemented dose calculation after changing it to AAA, and compared and analyzed treatment plan using Dose Volume Histogram (DVH). Results: Firstly, as a result of evaluating PBC algorithm of Conventional plan and the difference according to AAA, the average difference of CI value on target volume has been highly estimated by 0.295 on PBC algorithm and as a result of evaluating dose of lung, $V_{47Gy}$ and $V_{45Gy}$ has been highly evaluated by 5.83% and 4.04% each, Mean dose, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$ has been highly evaluated 0.6%, 0.29%, 6.35%, 10.23% each on AAA. Secondly, in case of FiF plan, the average difference of CI value on target volume has been highly evaluated on PBC algorithm by 0.165, and dose on ipsilateral lung, $V_{47Gy}$, $V_{45Gy}$, Mean dose has been highly evaluated 6.17%, 3.80%, 0.15% each on PBC algorithm, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$ has been highly evaluated 0.14%, 4.07%, 4.35% each on AAA. Conclusion: When calculating with AAA on breast cancer tangential plan, compared to PBC algorithm, Conformity on target volume of Conventional plan, FiF plan has been less evaluated by 0.295, 0.165 each. For the reason that dose of high dose region of ipsilateral lung has been showed little amount, and dose of low dose region has been showed much amount, features according to dose calculation algorithm need to be considered when we evaluate dose for the lungs.

  • PDF

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Verification of Clinical Usefulness of Jaw Tracking in IMRT (IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증)

  • Kim, Jin-young;Kim, Ki-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • Intensity-modulated radiotherapy(IMRT) has disadvantages such as increasing the low doses of irradiation to normal tissues and accumulated dose for the whole volume by leakage and transmission of the Multi Leaf Collimator (MLC). The accumulated dose and low dose may increase the occurrence of secondary malignant neoplasms. For this reasons, the jaw tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and transmission dose of the MLC with existing linear accelerators. But quantitative analysis of the dose reduction has not been verified. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw tracking function in brain tumor with comparison of treatment plans. To accomplish this, 3 types of original treatment plans were made using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) beyond 2 cm distance from the Organs At Risk (OARs); 2) within 2 cm distance from the OARs; and 3) intersecting with the OARs. Jaw tracking treatment plans were also made with copies of the original treatment planning using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the 2 types of treatment planning methods was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In the DVH comparison, the maximum difference of 0.5 % was observed between the planning methods in the case of over 2 cm distance, and the maximum of 0.6 % was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum difference of 2 % was achieved. According to these results, it could be realized that the differences of mean dose and maximum dose to the OARs was larger when the OARs and PTV were closer. Therefore, treatment plans with the jaw tracking function consistently affected the dose reduction and the clinical possibility could be verified.

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF