• Title/Summary/Keyword: 가속수명

Search Result 446, Processing Time 0.02 seconds

Development of Long-Life Asphalt Pavements Method Using High Modulus Asphalt Mixes (고강성 기층재를 적용한 장수명 아스팔트포장 공법 개발)

  • Lee Jung-Hun;Lee Hyun-Jong
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.49-61
    • /
    • 2006
  • This study suggests long-life asphalt pavement method which can save maintenance cost by increasing the design and performance period of pavements. The high modulus asphalt binder developed and then various physical tests are performed. Laboratory performance tests and accelerated pavement test are conducted for the high modulus and conventional mixtures. The test results show that dynamic modulus values of high modulus mixtures are higher than those of the conventional mixtures, The high modulus mixtures yield better fatigue, rutting and moisture damage performance than conventional mixtures. Structural analysis is performed and a database is built up for long life asphalt pavement design. Pavement response model is developed through a multiple regression analysis program, SPSS using the database. A design software for the long life pavements is developed based on the pavement response model and laboratory and field performance tests results. In addition, optimum pavement sections and materials are suggested. The suggested AC thickness of long life asphalt pavement is 29cm. A Life cycle cost analysis(LCCA) is conducted to check the economical efficiency of the long life pavement section. The LCCA result shows that initial construction costs of long life and conventional pavements are almost equal, but long life pavement is more profitable in terms of the LCCA.

  • PDF

Analysis of Degradation Behaviors of Geomembrane by Accelerated Test under UV Exposure Conditions (자외선 노출조건 하에서 가속시험에 의한 지오멤브레인의 분해거동 해석)

  • Park, Yeong Mog;Khan, Belas Ahmed;Jeon, Han Yong
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.5-14
    • /
    • 2013
  • In this paper the effect of UV (ultraviolet) exposure on HDPE (high density polyethylene)-smooth and f-PP (flexible polypropylene) geomembranes is evaluated under UVB-313 (ultraviolet wavelength 290-315 nm) exposure. Tensile property, melt flow index (MFI), oxidation induction time (OIT), both standard-OIT and high pressure-OIT and Fourier transform infrared spectroscopy/attenuated total reflectance (FTIR/ATR) results are discussed. Although tensile properties of the exposed geomembrane samples remained unchanged, the depletion of antioxidants was found higher for f-PP than for HDPE geomembrane. Arrhenius model by extrapolation was used on the data to predict the antioxidant lifetime to a typical site temperature of $20^{\circ}C$. There was no significant difference between the MFI value of the virgin and UV exposed HDPE geomembrane samples but a decrease in MFI was found in f-PP geomembrane that signifies that crosslinking has occurred. From FTIR spectra, the small peak (near $1750\;cm^{-1}$) observed in the spectrum of UV exposed sample corresponds to a carbonyl (C=O) linkage, which suggests that oxidation has occurred in the polymer structure, and another new band for f-PP between 3100 and $3500\;cm^{-1}$ is attributed to a hydroxyl bond and/or hydroperoxide bond.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Design Technique for Durability Improvement of Military Vehicle Clutch System (군용차량 클러치 내구수명 향상에 대한 연구)

  • Shin, Cheol-Ho;Kang, Tae-Woo;Kim, Sung-Gon;Kim, Seon-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.117-124
    • /
    • 2019
  • Military Vehicles of the Korean army had been developed before 2004 and used manual transmissions. Manual transmissions contain a clutch system regulating the force from engine to transmission. In this study, a 2.5-ton military vehicle's clutch system was investigated. The existing clutch system had the characteristics that need to adjust the clearance between the clutch cover and release bearing. Improper clearance led to early wear of the clutch disk and failure of the clutch cover. To solve these problems, an improved clutch system was suggested and tested. The improved clutch system contains auto adjustment of the clearance and an enhanced clutch disk. To verify the improved clutch systems, 2 stage tests were conducted: an accelerated life test of the clutch system, and a driving test by trainee of driving more than 3,000km. As a result, the problems caused by the improper clearance adjustment were solved and this design was verified.

Degradation evaluation of paint films on surface treated steel by electrochemical impedance spectroscopy (전기화학적 임피던스 분광법에 의한 표면처리한 강재 도장의 부식-도막 열화도 평가)

  • Park, Jun-Mu;Park, Jae-Hyeok;Kim, Sun-Ho;U, Sang-Gyun;Gwon, Yong-Min;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.95-95
    • /
    • 2018
  • 강재의 방식법 중 도장은 부식을 억제하는데 효과적이고 편리한 방법으로 선박 및 해양 강 구조물의 방식법으로 사용되고 있다. 한편, 강 구조물의 효율적인 유지관리를 위해서는 방식 도장의 도막 열화도를 평가하고 잔존 수명을 예측하여 최적 시기에 보수도장 혹은 재도장하는 것이 필요하다. 일반적으로 선박 및 해양구조물에 적용되는 도막의 방식 성능 평가 방법으로 해수 침지 시험, 염수 분무 시험, 옥외 폭로 시험 등이 있다. 그러나 이러한 시험들은 그 시험 방법에 따라서 정량적인 평가에 한계가 있음은 물론 장기간 소요되는 등 곤란한 문제점이 있다. 그러므로 선박 및 해양구조물을 비롯하여 교량, 각종 강 구조물의 도장 방식에 사용되는 방식용 도료의 성능을 단기간에 적절하게 평가할 수 있는 가속시험법이 제시되며 연구-사용되고 있다. 그 중 도막 방식 성능을 보다 효율적, 비파괴적, 정량적으로 평가할 수 있는 임피던스 분광법(EIS)과 같은 전기화학적 방법은 상대적으로 시험 기간을 크게 단축시킬 수 있고, 대상 방식 도장의 미세한 성능 차이도 분별 가능하다는 장점이 있다[1]. 따라서 본 연구에서는 선박 및 해양구조물 등 가혹한 부식환경에서 강력한 내구성을 가질 수 있도록 다양한 종류의 표면처리 도장 시편을 제작하여 자외선 조사-염수분무-침지환경 등의 열악한 환경조건 하에서 부식-열화 촉진 시험을 실시하였다. 그리고 그 촉진 열화 과정에서 도막의 외관 상태를 관찰 분석함은 물론 전기화학적 임피던스 분광법을 병행 측정하며 그 표면막의 부식 및 도막 열화도를 비교-종합 평가하였다.본 연구에 사용된 시편은 Al 및 Zn 도금 강판에 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편으로 Scribe, No Scribe 및 비교재 Al 및 Zn 도금 시편으로 분류하여 각각 실험을 진행하였다. 즉, 도막 열화 시험은 복합 노화 시험법으로 UV 조사 36 시간(ASTM G53), 염수분무 32 시간(ISO 7253), 수분 응축 10 시간을 1 Cycle로 100 Cycle(7800 시간) 동안 실험을 진행하였다. 이때 도막 열화도 평가는 전기화학적 임피던스 분광법을 이용하여 각 실험 조건별로 주파수에 따른 임피던스(Z) 값을 평가하였다. 즉, 상온 $25^{\circ}C$의 3.5% NaCl 100 ml 수용액에 작동 전극(Working Electrode)과 구리 도선을 통해 연결하였고, 노출 면적은 $1cm^2$로 일정하게 유지 하였으며, 상대 전극(Counter Electrode)은 탄소봉, 기준 전극(Reference Electrode)으로 포화카로멜전극(Saturated Calomel Electrode)을 사용하여 측정하였다. No Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편이 우수한 도막 저항성을 나타내었으며, 에폭시-우레탄 도장시편은 23사이클 이후의 저항값이 가장 낮게 나타났다. Zn 기판의 경우는 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편 모두 저항 값이 유사하였으며, Al 및 Zn 도금 시편은 도장 처리된 시편에 비해 훨씬 낮은 저항 값을 보였다. 또한 Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편에서 높은 초기 저항 값을 보였으며, 23 사이클 후의 저항 값은 세 종류의 도막에서 약 1~0.1 Gohm 으로 나타났다. 그리고 Zn 기판 에폭시-실리콘 우레탄 도장 시편에서 가장 낮은 도막 저항 값이 나타났다. 이상의 실험을 통해서 본 연구 내용은 실내촉진시험으로 선박 및 해양 강 구조물에 사용되는 다양한 종류의 도막의 열화도를 평가하는 기초 설계 지침으로 응용될 수 있을 것으로 사료된다. 한편, 도막은 노출 환경에 따라 방식 성능이 다르므로 실제 도막의 사용환경을 고려하여 도장 사양별 적용 부위에 따른 적정 가속 실험 방법을 선정할 필요가 있다고 사료된다.

  • PDF

A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field (다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구)

  • Kim Joo-Ho;Lee Sang-Gyu;Shin Hyun-Kyung;Lee Suk;Na Soo-Kyung;Cho Jung-Hee;Kim Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Purpose : Many authors have been introduced field in field technique and 3-D conformal radiotherapy that increased the tumor dose as well as decreased the dose of abutting critical organ. These technique have multiple beam direction and small beam segments even below 10 MU(monitor unit)for each field. we have confirmed the influence of low MU on dose output and beam stability. Materials and Methods : To study the dose output, the dose for each field was always 90MU, but it divided into different segment size: 1, 2, 3, 5, 10, 15 segments, 90, 45, 30, 18, 9, 6 MU the measurements were carried out for X-ray energy 4 MV, 6 MV, 10 MV of three LINAC(Varian 600C, 2100C, 2100C, 2100C/D), in addition each measurement was randomly repeated three times for each energy. To study the field symmetry and flatness, X-omat V films were irradiated. After being developed, films were scanned and analyzed using densitometer. Results : Influence of low MU on dose is slightly more increase output about $1.2{\sim}2.9%$ in cGy/mu than 90MU, but may not changed beam quality(flatness or symmetry), Output stability depends on dose rate(PRF)rather than beam energy, field size. Conclusion : Presented result are under the limits(out put<3%, flatness<${\pm}3%$, symmetry<2%). The 3 accelerators are safe to use and to perform conformal radiotherapy treatments in small segments, small MU around 10MU. but Even if the result presented here under the limits, continuous adjustments and periodic QA should be done for use of small MU

  • PDF