• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.03 seconds

Cycle Simulation of an Air Source Heat Pump Using Liquid Injection (액분사 사이클을 이용한 공기 열원 열펌프의 사이클 시뮬레이션)

  • 김욱중;홍용주;남임우;강원일;공용상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2000
  • An air source heat pump using liquid injection technique, which can be applied for very low temperature climate, has been simulated to examine the design options. Comparison between the simulation and experiment has been carried out to validate the simulation method. Effects of various design parameters such as liquid injection rate and injection pressure are Investigated to optimize the performance of the heat pump. Finally, optimal liquid infection rate and injection pressure to maintain sufficient heating capacity and moderate discharge refrigerant temperature are suggested when the heat pump was operated at very low outdoor temperature.

  • PDF

A Study on the Impact of Inlet Temperatures of Heating Water and Feed Water on Operating Conditions of 2 Effect Desalination System (2중효용 담수장치의 가열열원과 공급수 온도에 의한 작동 상태 변화에 관한 연구)

  • Choe, Seong-Uk;Park, Jong-Jin;Jeong, Hyeong-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.663-668
    • /
    • 2006
  • In the present paper, a single stage fresh water generator was modified and extended to 2 effect desalination system. The inlet temperatures of hot water and feed water were selected as experiment parameters to get operating conditions and fresh water generating rates. The impacts of these parameters on operating conditions and fresh water generating rates were described in detail.

  • PDF

Thermal analysis inside a small chamber including radiation (미소 챔버 내 복사열전달을 수반한 열유동 해석)

  • Lee, Hyung-Sik;Do, Gi-Jung;Lee, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.194-198
    • /
    • 2006
  • In this study, numerical modeling was performed to analyze air flow including radiation heat transfer inside a small chamber. Characteristics of heat transfer between source plate and target through glass are investigated for various surface temperature of heat source plate with buoyancy effect due to gravity force. Conduction heat transfer through the glass is considered and heat source plate is assumed to be a black body. Target surface temperature is largely affected by the radiation heat transfer. It can also be seen that as the source temperature increases target surface is dominated by radiation rather than convective heat transfer by air.

  • PDF

A Study on the Energy Storage System Using Air Source Heat Pump for Heating and Cooling (공기 열원을 이용한 축열식 냉난방 시스템 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Seo, Jeong-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1125-1130
    • /
    • 2006
  • An air source heat pump system producing the ice and water storage energy for cooling and heating of building has been proposed. Cycle design and simulation considering energy balance between heating and cooling capacity has been carried out. The roles of the capacity controlled compressor, refrigerant heating device and air preheating are investigated in detail. System control logic for meeting the predetermined heating capacity when the system is operated at cold climate condition is suggested. Some anticipated problems of the proposed system are also described.

  • PDF

영광 3 호기 부분충수운전중 정지냉각펌프 안전성 평가

  • 류용호;김세원;유병철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.315-320
    • /
    • 1996
  • 영광 3호기의 정지냉각펌프 성능감시 설비로는 펌프 유량계, 입구압, 출구압, 모터전류 등이 있으며 현장에서 펌프의 소음 감시나 진동 측정 등을 통하여 펌프 건전성을 확인할 수 있다. 부분충수운전중 여러 연구결과 제시된 펌프의 이상징후 증상은 펌프의 소음 증가, 유량계 또는 모터전류의 불규칙 요동이 있으나 정량적인 값을 제시하지 못하고 있으며 공기유입량에 대한 운전제한 근거만 정량적으로 제시되고 있다. 즉, WCAP-l1916에 따른 펌프의 손상 판단 근거는 연속적인 공기 흡입의 경우 2%이내, 간헐적인 공기흡입의 경우 5%를 제시하고 있다. 영광 3 호기의 부분충수운전시 펌프 입구압력을 제외한 다른 펌프 성능감시 변수들은 허용오차 이내로 별다른 펌프 이상 징후를 발견하지 못하였다. 그러나 펌프 입구압력 기록계의 입구압력 및 진동폭 변화는 정지냉각유량률, RCS 수위, 증기발생기 노즐댐 설치 유무에 따라 민감한 변화를 보여주었으며, 펌프의 건전성 감시에 가장 효과적인 변수임을 보여주었다.

  • PDF

Antioxidative Effects of Diarylheptanoids from Alnus hirsute (물오리나무에서 분리된 Diarylheptanoid의 항산화작용)

  • 이연아;조수민;김광호;김준식;김세원;이민원
    • YAKHAK HOEJI
    • /
    • v.44 no.2
    • /
    • pp.193-196
    • /
    • 2000
  • Four diarylheptanoids oregonin, hirsutanonol, 1,7-bis- (3,4-dihydroxyphenyl)-heptane-5-O-$\beta$-D-xylopyanoside and 1,7-bis-(3,4-dihydroxyphenyl)-heptane-5-0-$\beta$-D-glucopyranoside isolated from Alnus hirsuta were evaluated for their antioxidative effects with 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical and lipid peroxidation generation system mediated by addition of $H_2O$$_2$and/or Fe$^{2+}$ to rat liver homogenate. All these diarylheptanoids showed significant inhibitory activities against the DPPH radical and demonstrated strong activities in preventing the lipid peroxidation induced by $H_2O$$_2$.>.

  • PDF

A Study on the Splenic Constipation(脾約) in Donguisusebowon (『동의수세보원』의 비약(脾約)에 관하여)

  • Park, Se-Won;Park, Seong-Sik
    • Journal of Sasang Constitutional Medicine
    • /
    • v.30 no.4
    • /
    • pp.1-10
    • /
    • 2018
  • Objective The purpose of this study is to understand the meaning of Splenic Constipation(脾約) in "Donguisusebowon(東醫壽世保元)". Methods We investigated the provisions associated with splenic constipation written in "Donguisusebowon", "Donguibogam(東醫寶鑑)", "Shanghanlun(傷寒論)" and several papers which related to splenic constipation. Results and Conclusions 1. Splenic constipation in "Donguisusebowon" falls into the category of Soeumin Yang Depletion Symptomatology(少陰人 亡陽病). The symptoms of splenic constipation include sweating and smooth urination. 2. Splenic constipation in "Donguisusebowon", "Shanghanlun", "Donguibogam" is based on fluid deficiency, but splenic constipation in "Donguisusebowon" is focused on sweating unlike "Shanghanlun" and sweating was quoted in "Donguibogam". 3. Splenic constipation in "Shanghanlun" and "Donguibogam" is focused primarily on constipation. The difference is that splenic constipation in "Donguibogam" relates to sweating. 4. Therefore, even if they use the same term, we need to understand that the meaning of splenic constipation in "Donguisusebowon" is different from that of "Shanghanlun" and "Donguibogam".

A Case Study of a Dysgeusia in a Soyangin Patient (이상미각을 호소하는 소양인 치험 1례)

  • Park, Se-Won;Keum, Na-rae;Bae, Hyo-Sang;Park, Seong-Sik
    • Journal of Sasang Constitutional Medicine
    • /
    • v.30 no.4
    • /
    • pp.53-58
    • /
    • 2018
  • Objective The purpose of this case study was to report improvements of a Soyangin patient with dysgeusia which a salty taste persisted in the mouth. Methods This patient was identified as Soyangin and treated by Yangkyuksanwha-tang-gamibang, acupuncture and moxa. Patient's symptom was assessed G/A(Global Assessment). Results and Conclusions The symptom of a lasting salty taste in the mouth was improved remarkably after using Korean medicine treatment, especially Yangkyuksanwha-tang-gamibang.

Feasibility Study on Leveling Method of Electric Power Load by Applying Thermal Storage Air Conditioning System (축열식 열원시스템 적용에 의한 전력부하 평준화의 경제성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Reducing global warming potential has become important, and as one of those methods for reducing it, economic evaluation by applying ice thermal storage air conditioning system was performed. The floor area and height of the subject building was assumed $5,000m^2$ and 20 m. Absorption chillerheater system and air source heat pump system was used for comparing to the subject system, and payback period method was used to perform economic evaluation. Although the running cost of ice thermal storage system is reduced compared to two systems, the ratio is not significant compared to the increase of initial construction expenses, and payback period was calculated to be about 7.7 and 79.3 years. However, the heat storage system should be approached from the viewpoint of long term rather than the economic standard in the present standard.

An Analysis of First Flush Phenomenon of 3 Catchment area in Lake Sihwa Watershed during Rainfall-Runoff Events (강우유출수 영향에 따른 시화호 소유역별 유입하천의 오염물질 초기유출현상 분석)

  • Kim, Sea-Won;Oh, Jong-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.475-485
    • /
    • 2011
  • Lake Sihwa has a very unique watershed environment, surrounded by industrial, urban and rural catchment area with different land use. The first flush phenomenon was investigated in 3 catchment area. 4TG, representing the industrial area, shows rapid discharges of highly concentrated pollutants during the early stages of a storm and it is indicating a strong first flush effect. At AS, representing the urban area, the pollutant concentration reached its peak approximately 2~3 hours after the start of storm, which is a strong first flush effect did not appear. JJB and MS represent the rural areas, the PEMC analysis results suggest that highly concentrated pollutants were discharged during the middle and latter stages of a storm, instead of early pollutant runoff due to the effects of rainwater runoff.