• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.027 seconds

A fouling mitigation device for a wastewater heat recovery heat pump system using a bubbling fluidized bed with cleaning sponge balls (버블 유동층과 세정 볼을 이용한 폐수 열원 히트펌프 시스템 증발기의 관 외측 오염 저감 장치에 관한 연구)

  • Kim, Jong-Soo;Kim, Do-Bin;Kim, Jun-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.152-156
    • /
    • 2016
  • Wastewater heat recovery heat pump systems use heated wastewater from public baths or factories as the heat pump's heat source. Generally, this system uses a bare tube evaporator. In the heat transfer process from wastewater to refrigerant, thermal resistance is caused primarily by fouling deposits on the outside surface of tube. Fouling directly increases thermal resistance and decreases heat pump efficiency. Thus, it is desirable to eliminate fouling. In this study, we fabricated a fouling mitigation device using a bubbling fluidized bed with cleaning sponge balls in the wastewater bath. Experimental conditions were as follows: $20^{\circ}C$ cold-water temperature, $40^{\circ}C$ wastewater temperature, 100 L/h cold water flow rate, and $0.161m^2$ heat exchanger surface area. Experimental results showed that the thermal resistance of fouling decreased by 56% with the fluidized bed alone and by 86% with both the fluidized bed and cleaning sponge balls.

In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging (자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.172-180
    • /
    • 2003
  • The purpose of this study is to observe the heat transfer process in in-vivo human muscle based on Proton Resonance Frequency(PRF) method in Magnetic Resonance Imaging(MRI). MRI was obtained to measure the temperature variation according to the heat transfer in phantom and in-vivo human calf muscle. A phantom(2% agarose gel) was used in this experiment. MR temperature measurement was compared with the direct temperature measurement using a T-type thermocouple. After heating agarose gel to more than 5$0^{\circ}C$ in boiling hot water, raw data were acquired every 3 minutes during one hour cooling period for a phantom case. For human study heat was forced to deliver into volunteer's calf muscle using hot pack. Reference data were once acquired before a hot pack emits heat and raw data were acquired every 2 minutes during 30minutes. Acquired raw data were reconstructed to phase-difference images with reference image to observe the temperature change. Phase-difference of the phantom was linearly proportional to the temperature change in the range of 34.2$^{\circ}C$ and 50.2$^{\circ}C$. Temperature resolution was 0.0457 radian /$^{\circ}C$(0.0038 ppm/$^{\circ}C$) in phantom case. In vivo-case, mean phase-difference in near region from the hot pack is smaller than that in far region. Different temperature distribution was observed in proportion to a distance from heat source.

A Basic Experimental Study on the Heat Energy Harvesting for Green SOC (녹색 사회기반시설의 열 에너지 하베스팅을 위한 기초실험 연구)

  • Jo, Byung-Wan;Lee, Duk-Hee;Lee, Dong-Yoon;Kim, Yoon-Ki
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.93-101
    • /
    • 2010
  • As the number of indispensable needs of clean energy increases due to the green new deal revolution, the possibility of heat energy harvesting from the surrounding infrastructures such as a railroad or highway was verified. In order to find more efficient usage of a heat source, the possibility of transforming heat into electricity were confirmed using Bi-Te type thermoelectric element, and electrical quality were tested with experiments of different heat source and environmental change in the surrounding infrastructures. After careful experiments, the possibility of collecting thermal energy and findings of the heat temperature change in infrastructrue are verified with a result of obtaining almost 20.82W in 70 celcius($^{\circ}C$) temperature differences and $1m^2$ surface area. Consequently, the ratio of heat temperatiure change and transforming surface area is the most crucial factor in the harvesting heat energy, and reducing thermal loss and improving thermal convection as well as transformation efficiency of thermoelectric element is required to get more efficient and durable generation.

Theoretical Analysis on the Factors Affecting the Power Efficiency of the Kalina Cycle (칼리나 사이클의 발전효율에 영향을 미치는 요소에 관한 이론적 해석)

  • Lee, Ki-Woo;Chun, Won-Pyo;Shin, Hyeon-Seung;Park, Byung-Duck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5425-5433
    • /
    • 2014
  • This study examined the effects of the key parameters on the power efficiency of the waste heat power plant using the EES program to obtain data for the design of the 20kW Kalina power plant. The parameters include the ammonia mass fraction, vapor pressure, heat source temperature, and the cooling water temperature. According to the analyses, a lower ammonia mass fraction and a higher vapor pressure increase the efficiency, in general. On the other hand, this study shows that there is a specific region with a very low ammonia mass fraction, where the efficiency decreases with ammonia mass fraction. Regarding the vapor pressure at the turbine inlet, the power efficiency increases with increasing vapor pressure. In addition, it was found that the influence of the vapor pressure on the efficiency increases with increasing ammonia mass fraction. Finally, the optimal condition for the maximum power efficiency is defined in this study, i.e., the maximum efficiency was 15% with a 25bar vapor pressure, $160^{\circ}C$ heat source temperature, $10^{\circ}C$ cooling water temperature, and 0.4 ammonia mass fraction.

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF

Study on the Weight Reduction of Firefighter's Protective Clothing by Using Air Layer and Aerogels (공기층과 에어로젤을 이용한 특수방화복 경량화 연구)

  • Kim, Hae-Hyoung;Park, Pyoung-Kyu;Kim, Young-Soo;Hong, Seung-Tae
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.81-88
    • /
    • 2018
  • Air and ultra lightweight aerogels were used to lighten the weight of the firefighters' protective clothing. In order to lighten the firefighters' protective clothing composed of 3 layers (outer shell, mid-layer, lining), it was most effective to replace the lining which occupied the largest weight in the total weight with the new materials. Thermal protective performance tests were carried out on flame (ASTM D 4108), radiant heat (KS K ISO 6942) and mixing heat (KS K ISO 17492) of flame and radiation. When the lining felt was replaced with an air layer, the air layer must be at least 3 mm to meet the KFI and ISO standards for the thermal protective performance. However, even if the thickness of the air layer increased to 10 mm, the thermal protective performance was lower than that of the existing products. When the felt was replaced with aerogels, the TPP rating (ASTM D 4108) satisfied the KFI standard at the 2 mm thickness of the aerogels. When the thickness of the aerogels was 3 mm, the TPP rating was improved about 140% compared to the existing products. It was confirmed that not only weight reduction but also thermal protective performance was improved by use of aerogels. However, due to the fragile nature of aerogels, a method of fixing them to a constant thickness between layers constituting a firefighters' protective clothing should be considered in the future.

Performance Characteristics of Organic Rankine Cycle Using Medium Temperature Waste Heat with Different Working Fluids (중온 배기열을 이용한 유기랭킨사이클 작동유체별 성능특성)

  • Kwon, Dong-Uk;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Yoo, Ho-Sun;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.10 no.2
    • /
    • pp.38-47
    • /
    • 2014
  • Renewable Portfolio Standards was introduced into the system in Korea in 2012. Interest in the unutilized and renewable energy sources is increasing. and these being actively investigated. An organic rankine cycle has emerged as an alternative in order to take advantage of bio-gas engine heat of sewage treatment plants whose capacity is 1500 kW. The organic rankine cycle power system was simulated by a simulator which is a commercial program of power plant design and performance analysis. The biogas engine is operated by $460^{\circ}C$ and 2.7 kg/s flow rate in the sewage treatment plant. Working fluids(R-601a, R-123, R-245fa) are selected to use in ORC power system in this temperature range. It was the isopentane that is the best performance among three working fluids. It could be obtained net power of 163.1 kW and efficiency of 13.66% from isopentane in the simulation.

  • PDF

Performance Analysis on the Multi Stage Reheater Regeneration Cycle for Ocean Geothermal Power Generation (해양지열발전용 다단재열재생사이클 성능해석)

  • Lee, Ho Saeng;Cha, Sang Won;Jung, Young Kwon;Kim, Hyeon Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • In order to study the improvement of the multi stage regeneration cycles, muti-stage processes were applied to the cycles, respectively or together. The kinds of the cycles are multi stage reheater cycle (MS) and multi stage reheater regeneration cycle (MSR). Working fluid used was R134a and R245fa. Temperature of the heat source was $65^{\circ}C$, $75^{\circ}C$, and $85^{\circ}C$, and temperature of the heat sink was $5^{\circ}C$. Optimization simulation was conducted for improving the gross power and efficiency with multi stage reheater regeneration cycle for ocean thermal energy conversion(OTEC) with changing of a heat source, kind of the working fluid, and type of the cycle. Performance analysis of the various components was simulated by using the Aspen HYSYS for analysis of the thermodynamic cycle. R245fa shows better performance than R134a. This paper showed the most suitable working fluid with changing of a heat source and the kinds of working cycle. Compared to each other, MS showed better performance at gross power and MSR showed higher cycle efficiency.

Performance Analysis of Pyrotechnic Devices on the Reliability of Thermal Batteries (열전지의 신뢰성에 미치는 파이로테크닉 부품의 특성분석)

  • Cheong, Hae-Won;Kang, Sung-Ho;Kim, Kiyoul;Cho, Jang-Hyeon;Ryu, Byungtae;Baek, Seung-Su
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.1
    • /
    • pp.116-123
    • /
    • 2019
  • Thermal batteries are also called molten-salt batteries as the electrolyte is mainly composed of molten salt. The molten-salt electrolyte is a solid that does not conduct electricity at room temperature, but when it is melted by a pyrotechnic heat source, it becomes an excellent ionic conductor. Thermal batteries are a kind of pyrotechnic battery because they operate only when the solid electrolyte is melted by the heat energy provided by pyrotechnic materials. Pyrotechnic components used in a thermal battery include heat sources, fuse strips, and an igniter. The reliability of these pyrotechnic components critically affects the reliability and performance of the battery that must supply electricity stably to guided munitions even under extreme environmental conditions. Different igniter types offer different advantages: notch-type igniters offer improved ignition probability, whereas film-type igniters offer improved safety. The addition of metal oxides to the heat paper could improve the burn rate, and the ignition reliability could be greatly improved by using it with a flame igniter at the same time. Using a two-step reduction process, high-purity Fe particles in coral form can be safely obtained.

A Study on Heat Transfer and Pressure Drop Characteristics according to Block Size and Turbulence Generator's Placement in a Horizontal Channel (블록 크기 및 난류발생기 배치에 따른 수평채널내의 열전달 및 압력강하 특성에 관한 연구)

  • Seo, Kyu-Won;Lim, Jong-Han;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.639-647
    • /
    • 2019
  • Recently, as the semiconductor integration technology due to miniaturization and high density of electronic equipment have developed, it is importantly recognized the application of thermal control system in order to release inner heat generated from chips, modules, In this study, we considered the heat transfer and pressure drop characteristics in a horizontal channel with four blocks using k-${\omega}$ SST turbulence model During CFD (Computational Fluid Dynamics) analysis, the parameters applied block width, block height, heat source and turbulence generator placement etc. As the boundary conditions of analysis, the channel inlet temperature and flow velocity were respectively 300 K and 3.84 m/s, the heat flux was $358W/m^2$. As a result, the heat transfer performance was decreased as the block width ratio (w/h) was increased, while it was increased as the block height ratio (h/w) was increased. In addition, as the arrangement of heat source size was increased to high heat flux from low heat flux, it was influenced by heat source size and the heat transfer coefficient showed a tendency to increase, When the turbulence generator was installed in the upper part of block No. 1 position the closely to the channel entrance, the heat transfer characteristics was greatly influenced on the whole of four heating blocks. and in oder to consider the pressure drop characteristics, we are able to select the most appropriate turbulence generator's position.