• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.029 seconds

Correlation Analysis between BLE-based RSSI and SoC Internal or Local Temperature (BLE 기반 RSSI와 SoC 내부 또는 국부 온도의 상관관계)

  • Kim, Seong-Chang;Lee, Min-Jeong;Oh, Sung-Bhin;Kim, Jun-Su;Kim, Jin-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.89-91
    • /
    • 2022
  • Wireless sensor networks(WSN), which are mainly used for indoor positioning, rely on the accuracy of RSSI. This RSSI is sensitive to several factors that cause interference, and there are foreign studies showing that temperature has a large effect on RSSI in indoor/outdoor environment among several factors. The temperature of the indoor space is uneven due to heat sources or air cooling systems indoors, and temperature changes frequently occur at certain locations. In particular, in case of an indoor fire, the accurate positioning system is required to guide an evacuation route, but a high temperature is locally formed due to a fire around the receiver, so the RSSI value could be influenced. In this paper, the effect on RSSI is studied by analyzing the correlation between SoC internal/local temperature and RSSI.

  • PDF

Characterization of Composite Ground Reinforced with Recycled-Aggregate Porous Concrete Pile (RAPP) (순환골재 다공질 콘크리트말뚝(RAPP)에 의해 보강된 복합지반의 거동 특성)

  • You, Seung-Kyong;Kim, Se-Won;Lee, Chul-Ho;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.117-130
    • /
    • 2009
  • In this paper, a series of laboratory chamber tests were carried out to evaluate the applicability of a porous concrete pile fabricated with recycled aggregates (RAPP) for the soft ground improvement. While performing the laboratory chamber tests for the RAPP, the surface settlement, excess pore pressure and vertical stress distribution with time were compared with those of SCP provided by You (2003) under the same experimental condition. In addition, the experimental results were compared with the numerical simulation using ABAQUS in this study. The results show that the settlement reduction is significantly enhanced due to the stress-sharing mechanism between the RAPP and soil formation by stress concentration on the RAPP. Furthermore, the comparison of consolidation rate shows that the RAPP can accelerate consolidation as well, which behaves as a vertical drain.

Numerical Simulation of Standing Column Well Ground Heat Pump System Part 1: Validation of the Numerical Model (단일심정 지열히트펌프의 수치적 모델링 Part I: 수치해석 모델 검증)

  • Park, Du-Hee;Kim, Kwang-Kyun;Kwak, Dong-Yeop;Chang, Jae-Hoon;Park, Si-Sam
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.33-43
    • /
    • 2010
  • Geothermal energy is gaining wide attention as a highly efficient renewable energy and being increasingly used for heating/cooling systems of buildings. The standing column well (SCW) is especially efficient, cost-effective, and suitable for Korean geological and hydrological conditions. However, a numerical model that simulates the SCW has not yet been developed and applied in Korea. This paper describes the development of the SCW numerical model using a finite-volume analysis program. The model, through hydro-thermal coupled analyses, simulates heat transfer through advection, convection, and conduction. The accuracy of the model was verified through comparisons with field data measured at SCWs in the U.S. and Korea. Comparisons indicated that the SCW numerical model can closely predict the performance of a SCW. The numerical model was used to perform a comprehensive parametric study in the companion paper.

Study of Reduction of Mismatch Loss of a Thermoelectric Generator (열전발전 시스템의 부정합손실 저감방안 연구)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.3
    • /
    • pp.294-301
    • /
    • 2022
  • In this study, a multi-layer cascade (MLC) electrical array configuration method for thermoelectric generator consisting of plural number of thermoelectric modules (TEMs) was proposed to reduce mismatch loss caused by temperature maldistribution on the surfaces of the TEMs. To validate the effect of MLC on the mismatch loss reduction, a numerical model capable of reflecting multi-physics phenomena occuring in the TEMs was developed. MLC can be employed by placing a group of TEMs experiencing relatively low temperature differences in an electric layer with more electrical branches while locating a group of TEMs experiencing relatively high temperature differences in an electric layer with less electrical branches. The TEMs were classified using the temperature distribution obtained by the numerical model. A MLC with an optimal electrical branch ratio showed a 96.5% of electric power generation compared to an ideal case.

A case study of a Patient with Poststroke Urinary retention treated with Traditional Korean Medicine (뇌졸중 후 요저류 환자 치험 1례)

  • Kim, Se-won;Kim, Gyung-muk;Jung, Min-ho;Cho, Ki-ho;Moon, Sang-kwan;Kwon, Seung-won;Jin, Chul;Jung, Woo-sang
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • ■ Objectives The purpose of this case report is to show the effect of Traditional Korean Medicine(TKM) on a patient with poststroke urinary retention ■ Methods A stroke patient with urinary retention was treated with herbal medication(Paljungsan), acupuncture, electro-acupuncture and moxibustion. To evaluate the effect of TKM on post-stroke urinary retention, we observed voiding pattern and residual urine after voiding. ■ Results Maintenance of regular self voiding and decrease of residual urine after voiding were observed after the TKM treatment. ■ Conclusion This study showed the effect of TKM treatment on Urinary retention of stroke patient.

  • PDF

A Case Study on Lower Extremity Muscle of Elderly with Osteoarthritis in Ultrasonic Image (초음파영상에서 골관절염을 가진 노인의 하지 근육에 대한 사례연구)

  • Yoon, Se-Won;Park, Soo-Ji;Lee, Jeong-Woo
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.102-106
    • /
    • 2013
  • ■ Objectives The purpose of the this study was to investigate organization change(pennation angle) of lower extremity muscle in elderly with knee osteoarthritis through ultrasonic image. Also, we examined organizational change of muscle was by influenced after total knee replacement(TKR). ■ Methods Rectus femoris image was taken at 50% of the distance between the anterior superior iliac spine and the superior border of the patella. Vastus medialis image was taken at the most distal insertion level of vastus medialis on the medial border of the patella. measurements included the most distal insertion level of the vastus medialis on the medial border of the patella. ■ Results Change of pennation angle in rectus femoris showed decrease from 5.11° in preoperation to 4.29° in 1 week after operation. Change of pennation angle in vastus medialis showed decrease from 6.94° in preoperation to 5.76° in 1 week after operation. ■ Conclusion We consider decrease of pennation angle after total knee replacement in this study was casued by organizational change of muscle and this pennation angle was influenced force created by muscle. Therefore, we thinks that this pennation angle through ultrasonic image will be available to plane individual muscle exercise program and to confirm muscle mass by muscle strength training.

  • PDF

Early Diagnosis and Treatment Strategies of Obesity Hypoventilation Syndrome (비만성 저환기 증후군의 조기 진단 및 치료 전략)

  • Hwan Hee Kim;Sang Haak Lee;Sei Won Kim
    • Sleep Medicine and Psychophysiology
    • /
    • v.29 no.1
    • /
    • pp.4-8
    • /
    • 2022
  • Obesity hypoventilation syndrome (OHS) is defined as the triad of obesity (body mass index, [BMI] ≥ 30 kg/m2), daytime hypercapnia (PaCO2 ≥ 45 mm Hg), and sleep breathing disorder, after excluding other causes for hypoventilation. As the obese population increases worldwide, the prevalence of OHS is also on the rise. Patients with OHS have poor quality of life, high risk of frequent hospitalization and increased cardiopulmonary mortality. However, most patients with OHS remain undiagnosed and untreated. The diagnosis typically occurs during the 5th and 6th decades of life and frequently first diagnosed in emergency rooms as a result of acute-on-chronic hypercapnic respiratory failure. Due to the high mortality rate in patients with OHS who do not receive treatment or have developed respiratory failure, early recognition and effective treatment is essential for improving outcomes. Positive airway pressure (PAP) therapy including continuous PAP (CPAP) or noninvasive ventilation (NIV) is the primary management option for OHS. Changes in lifestyle, rehabilitation program, weight loss and bariatric surgery should be also considered.

Signal Detection of Alpha-adrenoceptor Antagonist using the KIDS-KAERS database (KIDS-KD) (한국 의약품부작용보고원시자료를 활용한 알파차단제의 이상사례 실마리정보 비교 분석)

  • Hyunji Koo;Jun Young Kwon;Jae-Hyuk Choi;Seung Hun You;Sewon Park;Kyeong Hye Jeong;Sun-Young Jung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.33 no.2
    • /
    • pp.86-96
    • /
    • 2023
  • Background: Using KIDS-KAERS database (KIDS-KD) from 2016 to 2020, the aim is to investigate signals of adverse events of alpha-adrenoceptor antagonists and to present adverse events that are not included in the precautions for use when marketing approval. Methods: This study was conducted by disproportionality analysis. Data mining analysis was performed to detect signals of alpha-adrenoceptor antagonists, such as terazosin, doxazosin, alfuzosin, silodosin, and tamsulosin. The signal was defined by three criteria as proportional reporting ratio (PRR), reporting odds ratio (ROR), and information component (IC). Detected signals were compared with product labeling and the European Medicines Agency-Important Medical Events list. Results: Out of the total number of 408,077 reports for adverse events, 6,750 cases were reported as adverse events of alpha-adrenoceptor antagonists. Dizziness, mouth dryness, hypotension postural, and oedema peripheral are identified as common adverse events of five alpha-adrenoceptor antagonists and are typically listed on drug labels. However, new signals were detected for pneumonia, chronic obstructive airway disease, eye diseases such as glaucoma and cataracts, fracture, and ileus of tamsulosin that were not previously listed on the drug labels in Korea. Conclusions: This study identified signals related to adverse drug reactions of alpha-adrenoceptor antagonists and presented serious adverse events, suggesting new adverse reactions to be aware of when using alpha-adrenoceptor antagonists.

What Factors Contribute to the Entry of Foreign Investors to Chinese Commercial Banks? (외국인투자자의 중국상업은행 투자결정요인에 관한 연구)

  • Kang, Shin-Ae;Sul, Woksik
    • International Area Studies Review
    • /
    • v.15 no.1
    • /
    • pp.367-389
    • /
    • 2011
  • This paper examines what factors contribute to the entry of foreign investors to Chinese commercial banks from 1996 to 2008. Empirical results show that using survival analysis, size, liquidity ratio and non-interest incomes are important to foreign investors. This indicates that as Chinese banking system opened, foreign investors invest in bigger but financially weak banks. For Joint-Stock commercial banks, foreign investors invest in banks whose asset qualities and non-interest incomes are low. But for City commercial banks, foreign investors invest in banks that are big but have low liquidity ratios. This results indicate that because City commercial banks operate in only one city, foreign investors require minimum bank size to operate in that city.

Development of a Geographic Information System(GIS)-Based Optimal Site System for Developing the Extreme Cold Region (공간정보(GIS) 기반 극한지 자원 개발 최적 위치 선정 시스템 개발)

  • Sewon Kim;Byungyun Yang;YoungSeok Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.63-71
    • /
    • 2023
  • The extreme cold regions, including the South and North Poles, are rich in resources, but there are many constraints on resource development projects due to difficult access and a construction environment that is completely different from that of Korea. In recent years, global warming has increased the demand for the construction of resource exploitation plants. For resource development construction activities, a preliminary site analysis is required to minimize the risk of project implementation. In this study, the factors were analyzed to be considered in construction activities in extreme cold and optimal location selection system based on Geographic information system(GIS) has been developed. As a result of applying the development system to Alberta, Canada, where oil sand development is actively underway, it was confirmed that the results were consistent with the currently operating oil sand mining area.