• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.026 seconds

Properties of the $\beta$-Sic+39vol.%$ZrB_2$ Composites Prepared by the Pressureless-Sintering (상압소결에 의해 제조한 $\beta$-Sic+39vol.%$ZrB_2$ 복합체의 특성)

  • Shin, Yong-Deok;Ju, Jin-Young;Yoon, Se-Won;Hwang, Chul;Lim, Seung-Hyuk;Song, Joon-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.894-896
    • /
    • 1999
  • The $\beta$-SiC+$ZrB_2$ ceramic composites were pressureless-sintered and annealed by adding 4, 8, 12wt% $Al_{2}O_{3}+Y_{2}O_{3}$(6 : 4wt%) powder as a liquid forming additives at $1800^{\circ}C$ for 4h. The relative density is over 79.3% of the theoretical density and phase analysis of the composites by XRD revealed of $\alpha$-SiC(6H, 4H), $ZrB_2$, $Al_{5}Y_{2}O_{12}$ and $\beta$-SiC(15R). Flexural strength showed the highest of 301.33MPa for composites added with 8wt% $Al_{2}O_{3}+Y_{2}O_{3}$ additives at room temperature. Owing to crack deflection and crack bridging of fracture toughness mechanism, the fracture toughness showed the highest of $3.6979MPa{\cdot}m^{1/2}$ for composites added with 8wt% $Al_{2}O_{3}+Y_{2}O_{3}$ additives at room temperature. The electrical resistivity was measured by the Pauw method from $25^{\circ}C$ to $700^{\circ}C$. The electrical resistivity of the composites showed the PTCR(Positive Temperature Coefficient Resistivity).

  • PDF

Beneficial effects of Paeo-tang on cardiovascular and renal function in L-NAME-induced hypertensive rats (파어탕의 L-NAME 유도 고혈압 동물군에서의 혈압강하효과 및 심신기능 개선 효과)

  • Na, Se Won;Hong, Mi Hyeon;Kim, Hye Yoom;Jang, Youn Jae;Yoon, Jung Joo;Lee, Yun Jung;Kang, Dae Gill;Lee, Ho Sub
    • Herbal Formula Science
    • /
    • v.28 no.3
    • /
    • pp.271-280
    • /
    • 2020
  • Hypertension has been approved to cause disharmony between the heart and kidney such as cardiac hypertrophy and kidney dysfunction. In traditional oriental medicine Paeo-tang (PET) has been shown to have effects on blood circulation improvement. However, the beneficial effect of PET on hypertension remains unknown. In this study, we investigated that PET attenuates blood pressure and improves cardiovascular and renal function in NG-nitro-L-arginine methylester (L-NAME) rat model. Hypertensive rat models were induced by the administration of L-NAME (40 mg/kg/day) and then PET (50 or 100 mg/kg/day) or Olmetec was treated for 2 weeks. PET treatment significantly suppressed the systolic blood pressure and decreased intima-media thickness in the thoracic aorta. PET ameliorated endothelium-dependent and independent vascular relaxation in the L-NAME-induced vascular dysfunction. PET ameliorated the functional decline in the kidney such as albumin and blood urea nitrogen in plasma. These results demonstrated that PET possesses protective effects against L-NAME-induced hypertension.

Physical Properties of Sulfur Concrete with Modified Sulfur Binder (유황개질 바인더를 사용한 유황 콘크리트의 물리적 특성)

  • Bae, Sung Geun;Gwon, Seong Woo;Kim, Se Won;Cha, Soo Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.763-771
    • /
    • 2014
  • Recently, a huge amount of sulfur has been produced as a byproduct of petroleum refining processes in Korea. Sulfur concrete is made of modified sulfur binder instead of cement paste, which has advantages of reducing $CO_2$ emission from cement industry as well as utilizing surplus sulfur. Also, sulfur concrete is a sustainable material that can be repetitively recycled. In this study, the physical properties of sulfur concrete are experimentally investigated. From the test results, sulfur concrete showed compressive strengths higher than at least 50MPa. Also, the unit weight, modulus of elasticity and splitting tensile strength of sulfur concrete was similar to that of Portland cement concrete (PCC). The coefficient of thermal expansion of sulfur concrete was a little larger than that of Portland cement concrete and sulfur concrete with mineral filler is helpful to lower the coefficient of thermal expansion. recycled aggregate sulfur concrete resulted in a slight reduction in the compressive strength, but sulfur concrete with recycled aggregate can achieve the high strength characteristics.

A Proposal of New Policies for Improving the Performance Analysis on Government R&D Expenditure in ICT Industry (ICT 분야 국가연구개발사업에 대한 성과분석 개선을 위한 정책제언)

  • Sul, Won-Sik
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.151-159
    • /
    • 2017
  • This paper proposes various policies for improving the process of performance analysis on R&D expenditure of the public funds in the Korean ICT industry. In order to do so, this paper figures out the present issues relating to performance indicators, methodologies for performance evaluation, release and comparison of evaluation results, follow-up study, integrated management system for performance analysis in ICT industry. In this paper, we suggest some new policies such as consulting an expert for improving performance indicators, maintaining the pre-determined performance indicators, introducing the qualitative performance indicators for measuring effectiveness, adopting the new methodologies reflecting R&D characteristics, introducing the new performance index for comparing annual performance, requiring follow-up study for major ICT R&D, introducing the independent and temporary organization for R&D performance analysis in ICT industry. In conclusion, these new policies will raise effectiveness and efficiency of the government R&D expenditure in ICT industry as well as strengthen the industry competitiveness.

A Study on Flame Structure and NO Emission in FIR- and FGR-applied Methane-air Counterflow Diffusion Flames (FIR과 FGR 기법이 적용된 메탄-공기 대향류 확산화염에서 화염구조와 NO 배출 연구)

  • Park, Jeong;Kwon, Oh Boong;Kim, Sewon;Lee, Changyeop;Keel, Sang-In;Yun, Jin-Han;Lim, In Gweon
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • Flame characteristics and NO emission behavior in $CH_4$/air-air premixed counterflow flames with applying FIR and FGR with $CO_2$ and $H_2O$ were investigated numerically by varying the ratios of FIR and FGR as well as global strain rate. Chemical effects of added $CO_2$ and $H_2O$ via FIR and FGR were analyzed through comparing flame characteristics and NO behaviors from real species($CO_2$ and $H_2O$) with those from their artificial species($XCO_2$ and $XH_2O$) which have the same thermochemical, radiative, and transport properties to those for the real species. The results showed that flame temperature and NO emission with FIR varied much more sensitively than that with FGR. Those varied little irrespective of adding $CO_2$, $H_2O$, and their artificial species to the fuel stream via FIR. However, Those were varied complicatedly by chemical effects of added $CO_2$ and $H_2O$ via FGR. Detailed analyses for them were made and discussed.

Effect of AC Electric Field on Decreasing Liftoff Height in Laminar Lifted Jet Flames (층류 부상 화염의 화염부상 높이 감소 구간에서 교류 전기장이 인가된 화염에 관한 영향)

  • Seo, B.H.;Van, K.H.;Kim, G.T.;Park, J.;Keel, S.I.;Kim, S.W.;Chung, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.17-22
    • /
    • 2017
  • An experimental study has been conducted to elucidate the effect of AC electric field on behaviors of laminar lifted flame in nitrogen-diluted methane coflow-jets. Our concerns are focued on the regime to show a decrease in liftoff height, $H_L$ with increasing nozzle exit velocity, $U_O$ (hereafter, $decreasing-H_L$). The $H_L$ with $U_O$ near flame extinction were measured by varying the applied AC voltage, $V_{AC}$ and frequency, $f_{AC}$ in a single electrode configuration. The behavior of $H_L$ with a functional dependency of $V_{AC}$ and $f_{AC}$ was categorized into two regime : (I) $H_L$ decreased for nozzle diameter, D = 1.0 mm, and (II) $H_L$ increased in the increase of $f_{AC}$ for a fixed $V_{AC}$ in a D = 4.0, 8.4 mm. The lifted flames in $decreasing-H_L$ region was unstable in high voltage regimes while the $H_L$ showed a decreasing tendency with $U_O$ except them. Such behaviors in $H_L$ were also characterized by functional dependencies of related physical parameters such as $V_{AC}$, $f_{AC}$, $U_O$, fuel mole fraction ($X_{F.O}$) and D.

Performance Comparison of Flooded Seawater Cooling System with respect to Heat Sink Temperature (열원수 온도에 따른 만액식 해수냉각시스템의 성능 비교)

  • Yoon, Jung-In;Choi, Kwang-Hwan;Son, Chang-Hyo;Kang, In-Ho;Kim, Chung-Lae;Seol, Sung-Hoon
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.91-96
    • /
    • 2016
  • A fleet consists of a main vessel, light vessels and carrying vessels for purse seine fishery. Carrying vessels contains fish storages to maintain freshness of catches. Currently most carrying vessels applies the cooling system using plain ice though accompanied various shortcomings. Seawater cooling system directly chilling seawater are now in use on carrying vessels in some developed countries to make up for these shortcomings and maximize advantages. This research deals with necessity of seawater cooling systems and establishes system criteria using Aspentech HYSYS program, prior to an experiment of compact-scale seawater cooling system which now in progress of manufacture. Performance comparison on condensation capacity, mass flow rate of working fluid, compressor power input, pump power input and others of the seawater cooling system applying a flooded evaporator is conducted with respect to the temperature of surface seawater varying according to seasons. The result presents that mass flow rate circulating the system is increased about 16.7% as the temperature of surface seawater increases. At the same condition, condensation capacity and compressor input work also increase about 9.8% and 91.2%, respectively.

Changes of Electroencephalogram according to Contraction Training Methods of Tibialis Anterior Muscle in Healthy Women (정상 여성에게서 앞 정강근의 수축훈련방법에 따른 뇌파의 변화)

  • Lee, Jeong-Woo;Kim, Moon-Jeong;Yoon, Se-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.127-133
    • /
    • 2012
  • Purpose: This study aims to examine the power changes in eletrocenphalogram (EEG) detected from the tibialis anterior muscle, during repetitive contraction exercise in normal female adults. Methods: The subjects of this study were 24 normal adult females, with no musculoskeletal or nervous system disorders. The 24 female subjects were divided into two groups: 12 subjects comprised a voluntary stimulation training group, and the other 12 subjects comprised an electrical stimulation training group. A total of thirty contractions were made repetitively by each woman, with maximal voluntary contraction exercise for six seconds, and a resting time of three seconds. During the experiment, their EEG was measured at eight positions. The eight positions were Fpz, Fz, Cz, CPz, C3, C4, P3, and P4, in accordance with the international 10~20 system. Results: The relative alpha power and beta power showed no statistically significant differences between the two groups. But the relative gamma power of the CPz, C3, C4, P3, and P4 areas showed statistically significant differences between the two groups (p<0.05). The relative theta power of the C4 area showed statistically significant differences between the two groups (p<0.05). Conclusion: Our findings show that tibialis anterior muscle contraction by electrical stimulation and by voluntary repeated contraction differentially affected brain activation. In particular, the CPz, C3, C4, P3 positions of relative gamma power showed brain activation in voluntary contraction. The C4 position of relative theta power showed different brain activation between the two groups.

Inhibitory Effect of Flusilazole on the Spore Formation of Aspergillus niger Causing the Onion Black Mold in Vapour Phase (Flusilazole의 훈증 효과에 의한 양파검은곰팡이병균(Aspergillus niger)의 포자 형성 억제)

  • Kim, Heung-Tae;Park, Se-Won;Choi, Gyung-Ja;Kim, Jin-Cheol;Cho, Kwang-Yun
    • Research in Plant Disease
    • /
    • v.8 no.2
    • /
    • pp.124-130
    • /
    • 2002
  • In 1998, a pathogen isolated from infected onions was identified as Aspergillus niger. At 3$0^{\circ}C$, A. niger AnYD-1 showed the best mycelial growth, spore germination, and high pathogenicity to onions. In spite of the weak inhibitory effect of flusilazole and hexaconazole on the mycelial growth on PDA, they showed the specific inhibitory activity against the formation of spores in the vapour phase. With flusilazole and hexaconazole, the effects of the solvent, the applied concentration and the incubating temperature on the activities inhibiting the spore formation were confirmed. Their inhibitory effect on the spore formation in vapour phase was excellent by solving them with dimethylsulfoxide and dimethylformamide among tested solvents, and applying them at high temperature such as 30~35$^{\circ}C$.

Measurement Bias of Heat Flux Gauge based on Calibration Constant supported by Manufacturer (제조사 보정상수에 기인한 열유속계의 측정 오차)

  • Kim, Sung-Chan;Hamins, Anthony
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • As a preliminary study to quantify the measurement uncertainty of the Schmidt-Boelter type heat flux gauge, the present study has been conducted to evaluate the measurement error due to the calibration constant supported by manufacturer. Calibrations of heat flux gauges are performed at NIST Fire Research Division using a calibration facility with heat source of a 2000 W halogen-tungsten filament lamp and the calibration constant is obtained by comparing the response of the reference and a standard heat flux gauge at the same irradiance conditions. Calibration for heat flux gauges made by three different manufacturers is compared with their factory calibration constant. Relative error due to fluctuation of output signal from heat flux gauges does not exceed 1% of the mean value and the relative error between calibration of this study and factory calibration constant ranged from 1.5% to 14.3%. The present study shows that a continuous and periodic calibration is necessary for accurate heat flux measurement.