• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.03 seconds

A Study on the Electromagnetic Properties of $La_{1-x}Ca_xMnO_3$(x=0.33) grown by Floating Zone Method (FZ법에 의한 $La_{1-x}Ca_xMnO_3$(x=0.33)의 결정성장과 전자기적 물성에 대한 연구)

  • 정준기;송규정;조남희;김철진
    • Korean Journal of Crystallography
    • /
    • v.13 no.1
    • /
    • pp.41-47
    • /
    • 2002
  • La/sub 1-x/Ca/sub x/MnO₃ manganese oxide were grown using the floating zone image furnace with halogen lamps as heat source. The growth condition was 4∼6 mm/hr growth rate in air atmosphere, 45∼50 rpm and 20∼25 rpm of rotation rate of feedrod and growing crystal, respectively. Characterization analyses of the crystal were carried out using XRD, SEM, and EPMA. Orientation of crystal was determined using EBSD. The electromagnetic properties were measured with Quantum Design PPMS by 4 point probe method and resulted MR value of 462% at 215 K.

High Power Diode Laser를 이용한 금형재료의 표면처리에 따른 재료의 물성 평가

  • Hwang, Hyeon-Tae;Kim, Jong-Do;Song, Hyeon-Su;Kim, Yeong-Guk;Kim, Jong-Ha
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.41.1-41.1
    • /
    • 2009
  • 최근 금형은 자동차뿐만 아니라 여러 산업에서 필수적이며 제품의 품질은 물론 제조원가에 막대한 영향을 미친다. 이러한 금형은 침탄, 질화, 고주파담금질등에 의해 표면처리 되어져 왔으나, 이와 같이 기존의 처리 방법은 모두 처리물 전체를 가열하거나 균일한 가열을 하지 못하기 때문에 변형의 문제와 처리후의 후가공의 경비 문제, 그리고 극히 일부분만 경화가 필요한 부품에는 적용하기 어려운 문제점이 있다. 이러한 문제를 해결할 수 있는 표면처리로서 레이저 표면처리 방법이 대두되고 있으며, 레이저 표면처리는 레이저 빔을 피처리물의 표면에 조사하고 적당한 속도로 이동을 하게 되면 레이저조사부위가 급속하게 가열되고 레이저빔이 통과한 후에는 표면의 열이 내부로 열전도 되어 급속히 자기냉각(Self-quenching)됨으로서 표면에 새로운 기계적 성질을 갖게 하는 표면처리법이다. 이와 같이 레이저를 이용한 표면처리로 기존의 CW Nd:YAG 레이저 열원보다 효율이 좋은 HPDL(High Power Diode Laser)를 이용한 고효율, 고기능 금형 표면처리 후 재료적 물성을 평가하고자 한다. 평가방법은 레이저빔의 조사속도 및 온도변화에 따른 표면처리부, 열영향부 그리고 모재 부분에 대한 경도특성 및 미세조직 변화를 관찰하였다. 또한 조사속도 및 온도변화에 대해 경화깊이를 관찰하였다.

  • PDF

A Study on the Performance Evaluation of Hybrid Energy System with Geothermal and Solar Heat Sources (지열-태양열원 복합시스템의 성능평가에 관한 연구)

  • Hwang In-Ju;Woo Nam-Sub;Lee Hong-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • The present study concerns the annual performance evaluation of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of the residential buildings. The hybrid energy system consists of ground source heat pump of 2 RT for cooling, solar collectors of $4.8m^2$, storage tank of 250 liters and gas fired backup boiler of 11.6 kW. The averaged coefficients of performance of geothermal heat pump system during cooling and heating seasons are measured as 4.1 and 3.5, respectively. Also solar fraction for hot water is measured as 35 percent. Overall, the results shows that the hybrid-renewable energy system satisfactorily operated under all climatic conditions.

Basic study on Eco-industrial Park utilizing thermal effluents as heat source (온배수를 열원으로 활용하는 생태산업단지 조성에 관한 기초 연구)

  • KIM, Dong-Kyu;KANG, Dae-Seok;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.21 no.3
    • /
    • pp.400-408
    • /
    • 2009
  • The purpose of this study is to know the concept of Eco-industrial Park and How to use the thermal effluents from power plants. Thermal effluents, which use sea water for cooling, from power plants have been discharged with about $6{\sim}7^{\circ}C$ higher temperature than near sea area. Therefore, it could effect on the marine ecosystem as a external pressure factor that increase the artificial thermal load in near sea area. The applications of thermal effluents had been surveyed through the several internal and external cases for utilizing heat sources and reducing the thermal load. As the precedence research for applying, the amount of heat sources of thermal effluents was evaluated. When the thermal effluents was fully applied in heat sources and available heat, assume that use heating season by 12 hours a day of demanded available heat, it was possible to calculate total 198 Tcal of energy saving.

An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating (PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구)

  • Chang, Min;Jung, Dong Il;Jung, Jong Ho;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

Application of Load by Purpose of Buildings for Application of Seawater District Cooling and Heating System in Jeju Area (제주 지역의 해수열원 지역냉난방 시스템 적용을 위한 건축물 용도별 냉난방 부하량 분석 및 적용방안)

  • Park, Jin-Young;Park, Jea-Hong;Kim, Sam-Uel;Chang, Ki-Chang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.86-90
    • /
    • 2014
  • It is important to select an optimal capacity for equipment, because the initial cost of new and renewable energy system is more expensive than that of exiting system. An optimal equipment and enhanced rate of operation can be selected, to analyze the cooling and heating load of buildings. In this study, seawater heat pump system in the Jeju area will be applied, by the heat source equipment of district heating. The loads of buildings are analyzed from existing researches, to select optimal capacity of equipment. Also, an optimal rate of building use will be set up, from a combination of buildings.

Performance Analysis of Heat Pump System with Air Source Evaporator and Single Unit Dual Sink Condenser (공기열원 2중히트싱크 열펌프의 성능해석)

  • Woo, J.S.;Lee, S.K.;Lee, J.H.;Park, H.S.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.11-22
    • /
    • 1998
  • Floor panel heating system using hot water is the primary heating system of domestic residential building. This paper presents the results of performance analysis of the heat pump system with air source evaporator and single unit dual sink(SUDSk) condenser. The heat exchanger combines two separated condensers into a single condenser and the object of the SUDSk condenser is to release energy to dual sinks, i.e. air for air heating system and water for panel heating system in one single unit. Simulation program is developed for single unit dual source(SUDS) SUDSk heat pump system and some experimental data are obtained and compared with simulation results. Differences of heating capacity and COP in dual source operating mode are 7% and 8% respectively. Simulation results are in good agreement with test results. Therefore, developed program is effectively used for design and performance prediction of dual source dual sink heat pump system with SUDS evaporator and SUDSk condenser.

  • PDF

A Study on Quantifying Sailing Safety Considering Maneuverability of a Vessel (선박의 조종특성을 고려한 운항안전성능의 수치화 방법에 관한 연구)

  • You, Youngjun;Kim, Sewon;Kim, Woojin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.113-124
    • /
    • 2017
  • Recently, ship owners are requiring an assessment of sailing safety of a ship from an analysis considering maneuverability and environmental loads etc. In this paper, we propose a new approach to assess sailing safety by considering the prescribed parameters. The concept of sailing safety is developed from DP capability analysis and is based on the maneuvering simulations. While the ship is continuously disturbed due to irregular environmental loads during the simulations, it is steered to keep its course along the way points assumed along a straight path. After relative distances between four edges of the ship and allowable safety boundaries are calculated for 3 hours, the minimum values are obtained. The minimum distances are marked on a polar chart and we call this a quantified safe operation judgment chart which indicates quantified sailing safety.

Production and Application of Recombinant Agarase (재조합 한천 분해효소의 생산과 응용)

  • Kim, Se Won;Hong, Chae-Hwan;Yun, Na Kyong;Shin, Hyun-Jae
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • The hydrolysis of biomass to fermentable sugar (saccharification) and to oligosaccharide is an essential process in biotechnology including biorefinery and biofood. Various macroalgae are commercially cultivated in several Asian countries as a useful resource for food and agar production. Agar is a major component of the cell walls of red algae that can be hydrolyzed by agarase. Agarases are classified into ${\alpha}$-agarase (E.C. 3.2.1.158) and ${\beta}$-agarase (E.C. 3.2.1.81) according to the cleavage pattern and grouped in the glycoside hydrolase (GH) family (GH-16, GH-58, GH-86, GH-96, and GH-118) based on the amino acid sequences of the proteins. Agarases have been isolated from various bacteria found in seawater and marine sediments. To increase productivity of the enzyme, a research on recombinant enzymes has been done. The application of recombinant agarase can be possible in the various filed such as energy, food, cosmetics, medical and so on. This paper reviews the source, biochemical characteristics and production system of recombinant agarases for further study.

A study on the fracture behavior of mild steel plate evaluated in the light of Taylor's work hardening theory (Taylor의 加工硬化理論의 입장에서 評價한 軟鋼薄板材의 破壞擧動에 관한 硏究)

  • 손세원;김상철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1335-1342
    • /
    • 1988
  • In this paper, mechanical properties of mild steel plate which was pretreated by prestress and prestrain loading conditions were studied. The variation of the mechanical properties of the test materials is evaluated in the light of Taylor's work hardening theory. Through this experimental study, it is recognized that material showed unstable phenomena after cyclic loading and it will recover its stability after a certain period of time accompaning the increment of hardness and the yield strength of the material. Also, the strength of smooth specimen, the notch strength of notch specimen and propagation behavior of fatigue specimen which were subjected to prestress and prestrain reveal that the optimal conditions may occur in the first, the middle and the later half of stage II of Taylor's work hardening theory, respectively.