• Title/Summary/Keyword: 傳記

Search Result 106,464, Processing Time 0.108 seconds

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.

A Study on the Concept of Operations and Improvement of the Design Methodology for the Physical Protection System of the National Infrastructure - Focused on Nuclear Power Plants - (국가기반시설 물리적 방호체계 운영개념 및 설계방법 개선방안 연구: 원자력발전소를 중심으로)

  • Na, Seog-Jong;Sung, Ha-Yan;Choi, Sun-Hee
    • Korean Security Journal
    • /
    • no.61
    • /
    • pp.9-38
    • /
    • 2019
  • As the scales & density of the Korean national infrastructures have been increased, they will be identified as rich and attractive potential targets for intensified North Korea's attack in the rear region and terrorism attack. In addition, due to changes in security environment such as drone threats and lack of security forces under the 52-hour workweek law, I think that it is the proper time point to reevaluate the effectiveness and appropriateness of the current physical protection system and its shift to a new system. In this study, the direction and improvement of the perimeter physical protection systems of the national infrastructures are to be studied from the viewpoints of its concepts of operations and design methodology, focusing on the nuclear power plant. The reason why we focus on nuclear power plants is because they cause wide-range and long-term damages caused by radioactive materials disperal and pollution, along with short-term damage caused by the interruption of electricity generation in the event of damage to nuclear power plants. With the aim of extracting improvement directions, as we will comprehensively review domestic research trends and domestic·overseas related laws, and consider Korea's specificity, we try to reframe the concept of operation - systematization, mobilization and flexibility -, and establish criteria on system change. In order to improve the technical performance of the new perimeter physical protection system, we study on high-fidelity·multi-methodology based integrated design methodology, breaking from individual silo-type design methods, and I suggest improvement of government procurement, its expansion to export business and other national infrastructure.

A study on the hydraulic characteristics of the geosynthetic clay liners(GCL) with humic substances of leachate on the landfill. (폐기물 매립지의 침출수의 휴믹물질에 의한 토목합성수지 점토라이너의 수리학적 특성에 관한 연구)

  • 한영수;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 2002
  • The study was performed to evaluate the effect of landfill leachate on the hydraulic conductivity of Geosynthetic Clay Liner (GCL) with two types of leachate. GCL used in waste landfills have a significant ability as a barrier material, however, they also have a potential danger when exposed to some organic and inorganic leachate as well as humic materials. In this study, swelling tests and hydraulic conductivity tests were performed to evaluate the effect of humic materials and landfill leachate on the hydraulic characteristics of the GCL. The result of swelling tests showed that the amount of humic materials and high electronic conductivity caused a decrease of the swelling of bentonite. This is expected to increase the hydraulic conductivity of GCL. The increasing of hydraulic conductivity observed for GCL permeated with 0-leachate was significantly higher than that of Y-leachate. This result shows that humic materials are obviously affecting with the increasing of hydraulic conductivity of GCL.

Physical and Chemical Properties of Cover Soils of waste Landfills in Kyonggi-Do Area (경기도 지역 쓰레기 매립지 복토층 토양의 이화학성)

  • 이상모;김기대;이은주;김판기;이군택
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.53-62
    • /
    • 2002
  • The physical and chemical properties of cover soils of 10 waste landfill sites in Kyonggi-Do area, where social circumstances at present forces to consider the reuse of landfill, were investigated to provide the informations of soil environment which are necessary to establish the appropriate ecological restoration plan of waste landfills. The pH and electrical conductivity of soils were higher in landfills sites than in reference sites (area around landfill sites), indicating the salt accumulation in surface soil. However, total-N and organic matter contents were lower in landfills sites than in reference sites. In landfill sites, the total-N and plant available-P contents were less than 0.15% and 20mg/kg, respectively. Exchangeable cations (K, Ca, Mg and Na) and heavy metal (Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn) contents varied between the landfill sites, but were higher in landfills sites than in reference sites. The major exchangeable cation of soil was Ca. Heavy metal contents were much lower than the critical concentration which phytotoxicity is considered to be possible and the standard for agricultural land of Korean Soil Environmental Preservation Act. Therefore, the proper soil management plan to increase the soil fertility is recommended for the ecological restoration of landfill using natural or artificial vegetation.

Effects of Additives on Soil Washing Efficiency for Mixed Surfactants (혼합 계면활성제에 적용된 각종 첨가제가 토양세척 효율에 미치는 영향)

  • Choi, Sang-Il;Jang, Min;Hwang, Kyung-Yub;Ryoo, Doo-Hyun
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.65-74
    • /
    • 1998
  • To enhance the washing efficiency of soil polluted by hydrophobic organic compounds, the effects of electrolytes and monomeric organic additives on micelle formation and washing efficiency of mixed surfactant solutions were investigated in this study. The surface tensions and critical micelle concentrations(CMCs) of the single and mixed surfactant solutions[$POE_5$/SDS] supplemented by NaCl were measured to investigate the effects on washing efficiency, and the composition ratios of surfactants and NaCl were optimized for the efficient soil washing system. As the mixing ratio of $POE_5$/SDS was increased to 80%, the mixed surfactant with 0.01M NaCl showed more proportional increase of washing efficiency than the mixed surfactant without any salts. The 3% solution of $POE_5$ and SDS(80%/2o%) with 0.01M NaCl showed the washing efficiency of 90%. However, the washing efficiency was not enhanced by NaCl addition to the single surfactant solution of $POE_5$. The CMC of SDS(0.049%) was higher than that of $POE_5$(0.016%), but the CMCs of mixed surfactants were decreased as the mixing ratio of $POE_5$ was increased. Alcohols having longer chain and branched carbon chain were found to be desirable for the soil washing additives.

  • PDF

Estimation of Groundwater Flow Rate into Jikri Tunnel Using Groundwater Fluctuation Data and Modeling (지하수 변동자료와 모델링을 이용한 직리터널의 지하수 유출량 평가)

  • Lee, Jeong-Hwan;Hamm, Se-Yeong;Cheong, Jae-Yeol;Jeong, Jae-Hyeong;Kim, Nam-Hoon;Kim, Ki-Seok;Jeon, Hang-Tak
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.29-40
    • /
    • 2009
  • In general, understanding groundwater flow in fractured bedrock is critical during tunnel and underground cavern construction. In that case, borehole data may be useful to examine groundwater flow properties of the fractured bedrock from pre-excavation until completion stages, yet sufficient borehole data is not often available to acquire. This study evaluated groundwater discharge rate into Jikri tunnel in Gyeonggi province using hydraulic parameters, groundwater level data in the later stage of tunneling, national groundwater monitoring network data, and electrical resistivity survey data. Groundwater flow rate into the tunnel by means of analytical method was estimated $7.12-74.4\;m^3/day/m$ while the groundwater flow rate was determined as $64.8\;m^3/day/m$ by means of numerical modeling. The estimated values provided by the numerical modeling may be more logical than those of the analytical method because the numerical modeling could take into account spatial variation of hydraulic parameters that was not possible by using the analytical method. Transient modeling for a period of one year from the tunnel completion resulted in the recovery of pre-excavation groundwater level.

Synthesis and Photoalignment of Soluble Polyimides Containing 4-Styrylpyridine Derivatives as Photoreactive Side Groups (광반응 곁사슬기로서 4-스티릴피리딘유도체를 가지는 용해성 폴리이미드의 합성과 광배향)

  • 김민우;안득균;이동호;박이순;서관호;하기룡;김우식
    • Polymer(Korea)
    • /
    • v.28 no.4
    • /
    • pp.314-320
    • /
    • 2004
  • Soluble aromatic polyimides bearing 4-(4-oxyalkyleneoxystyryl)- pyridines (ethylene and hexylene) as photoreactive side groups were synthesized and characterized. The photoreactive polymers were soluble in various polar organic solvents and their films were easily formed by solution casting. The photoreactivities of the polymers in the film state were approximately 64% at an exposure energy of 1.5 J/$\textrm{cm}^2$. Transmittances of the polymer films were about 85% after annealing at 20$0^{\circ}C$. Therefore, these polymers can be evaluated to be photoreactive polyimides with good transparency and solubility. The dichroic ratios of the polymers with ethylene and hexylene groups as the alkylene spacers were 0.023 and 0.026, respectively. The order parameters of 4'-pentyl-4-bipheny1carbonitrile as a liquid crystal (LC) in the film cells of the former and latter polymers were 0.50 and 0.52, respectively. These results indicate that the polymers show the effect of alkylene spacer on the photoalignments. The LC in the film cells of the polymers was perpendicularly oriented to the electric vector of the linear polarized UV light (LPUVL).

Area Effect on Galvanic Corrosion of Condenser Materials with Titanium Tubes in Nuclear Power Plants (Titanium 전열관을 사용하는 원전 복수기 재료의 Galvanic Corrosion에 미치는 면적의 영향)

  • Hwang, Seong-Sik;Kim, Joung-Soo;Kim, Uh-Chul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.507-514
    • /
    • 1993
  • Titanium tubes have recently been used in condensers of nuclear power plants since titanium has very good corrosion resistance to seawater. However, when it is connected to Cu alloys as tube sheet materials and these Cu alloys are connected to carbon steels as water box materials, it makes significant galvanic corrosion on connected materials. It is expected from electrochemical tests that the corrosion rate of carbon steel will increase when it is galvanically coupled with Ti or Cu in sea water and the corrosion rate of Cu will increase when it is coupled with Ti, if this couple is exposed to sea water for a long time. It is also expected that the surface area ratios, R$_1$(surface area of carbon steel/surface area of Ti) and R$_2$(surface area of carbon steel/surface area of Cu) are very important for the galvanic corrosion of carbon steel and that these should not be kept to low values in order to minimize the galvanic corrosion on the carbon steel of the water box. Immersed galvanic corrosion tests show that the corrosion rate of carbon steel is 4.4 mpy when the ratio of surface area of Fe/ surface area of Al Brass is 1 while it is 570 mpy when this ratio is 10$^{-2}$ . The galvanic corrosion rate of this carbon steel is increased from 4.4 mpy to 13 mpy at this area ratio, 1, when this connected galvanic specimen is galvanically coupled with a Ti tube. This can be rationalized by the combined effects of R$_1$ and R$_2$ on the polarization curve.

  • PDF

Anti-inflammatory Effect of the Cirsium japonicum var. ussuriense 70% Ethanolic Extract in RAW264.7 Cells by Heme oxygenase-1 Expression (엉겅퀴 70% 에탄올 추출물의 RAW264.7 세포에서 Heme oxygenase-1 발현을 통한 항염증 효과)

  • Lee, Dong-Sung;Kim, Kyoung-Su;Li, Bin;Choi, Hyun-Gyu;Keo, Samell;Jun, Ki-Young;Park, Jun-Hyeong;Kim, Youn-Chul
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Cirsium japonicum var. ussuriense has long been used in herbal medicine for the treatment of arthritis, dyspepsia, and bleeding in Korea. In the present study, we investigated anti-inflammatory effects of C. japonicum var. ussuriense against lipopolysaccharide(LPS)-induced activation in RAW264.7 cells by the expression of heme oxygenase (HO)-1. The 70% EtOH extract of the aerial parts of C. japonicum var. ussuriense (CJE), showed the potent anti-inflammatory effects on LPS-induced inflammation in RAW264.7 cells. The anti-inflammatory effect of CJE was demonstrated by the suppression of pro-inflammatory mediators, including pro-inflammatory enzymes (inducible nitric oxide synthase and cyclooxygenase-2). Furthermore CJE induced HO-1 expression through nuclear translocation of nuclear factor E2-related factor 2 (Nrf2) and increased HO activity in RAW264.7 macrophages. The effects of CJE on LPS-induced NO and $PGE_2$ productions were partially reversed by an HO-1 inhibitor, tin protoporphyrin (SnPP). Therefore, it is suggested that CJE-induced HO-1 expression plays a role of the resulting anti-inflammatory effects in macrophages. These results suggest that CJE may be a promising candidate for the treatment of inflammatory diseases.

Permeation Effect of NaCl into Shell Egg with Concentration of NaCl Solution, Salting Time and Salting Pressure (염지액농도, 염지시간 및 염지압력에 따른 계란의 염 침투효과)

  • 전기홍;유익종;장윤희;강통삼
    • Korean Journal of Poultry Science
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 1993
  • This study was performed to find the desirable conditions for processing salted hard-boiled egg without cracking egg shell in NaCl solution under pressure. Among the many factors affecting saltiness of the shell egg, concentration of NaCl solution(0~40%), different salting time(0~45h) and salting pressure (0~4.5kg/$\textrm{cm}^2$) were employed to identify the permeability of NaCl into shell egg at ambient temperature. The saltiness of the shell egg was proportionally risen as concentration of NaCl solution, salting time and pressure increased. The most desirable saltiness was observed at the 0.70~1.00% of NaCl in albumen and 0.40~0.45% in yolk, Besides the saltiness, sensory evaluation of the shell egg were carried out to evaluate the quality of the salted shell egg. The effect of various concentration of NaCl solution, salting time and pressure on sensory scores of hard-boiled salted eggs showed that 20~40% of NaCl solution, 12~20 h of salting time, 3~4.5 kg/$\textrm{cm}^2$ of salting pressure were proper conditions for processing the product. These results indicate that the desirable condition to get salted hard-boiled shell egg were ; 30% of NaCl solution, 16h of salting time and 4.0kg/$\textrm{cm}^2$ of salting pressure.

  • PDF