• Title/Summary/Keyword: [p]

Search Result 149,477, Processing Time 0.156 seconds

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF

Effect of Acute and Chronic Treatment with Risperidone on the Serotonin and Dopamine Receptors in the Rat Brain (Risperidone의 급성 및 만성 투여가 흰쥐 뇌의 Serotonin과 Dopamine 수용체에 미치는 영향)

  • Choi, Yun-Young;Son, Hye-Kyung;Kim, Chang-Yoon;Lee, Chul;Lee, Hee-Kyung;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.9-18
    • /
    • 1997
  • The therapeutic efficacy of antipsychotic drugs is generally attributed to their ability to block dopamine $D_2$ receptors. Classical $D_2$ antagonists are not effective to treat negative symptoms and produce extrapyramidal side effects On the other hand, atypical antipsychotic agents ameliorate negative symptoms without producing extra-pyramidal side effects, and it is reported to be associated with blockade of serotonin $5-HT_2$ receptors. The purpose of this study was to evaluate the effect of risperidone on neuroreceptors in the rat brain by Quantitative autoradiography method. In acute treatment group, risperidone was injected into Peritoneal cavity of male Wistar rats with dose of 0, 0.1, 0.25, 0.5, 1.0 and 2.0mg/kg in each group(5/group), and they were decapitated after 2 hours. In chronic treatment group, risperidone was injected with dose of 0, 0.1, and 1mg/kg(I.P.) for 21 days and decapitated after 24 hours following last treatment. The effect of risperodone on the binding of [$^3H$]spiperone to $5-HT_2$ and $D_2$ receptors were analysed in 4 discrete regions of the striatum, nucleus accumbens, and frontal cortex by quantitative autoradiography Acute treatment with risperidone reduced cortical $5-HT_2$ specific [$^3H$]spiperone binding to 32% of vehicle-treated control. Subcortical $5-HT_2$ specific [$^3H$]spiperone binding was not affected at all dose groups whereas a significant reduction (57%) in $D_2$ specific [$^3H$]spiperone binding was observed in risperidone treated group at doses of 1-2mg/kg. Chronic treatment with risperidone produced a decrease in the maximal number of cortical $5-HT_2$ receptors to 51% and 46% of control in 0.1mg/kg & 1mg/kg treated group respectively. In conclusion, risperidone is a cortical serotonin receptor antagonist with relatively weak antagonistic action on dopamine receptors. These effects oil neuroreceptors may explain the therapeutic effect of risperidone as a atypical antipsychotic agents.

  • PDF

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Effect of Whole Crop Barley Silage Feeding on the Growth Performance, Feed Requirement and Meat Quality of Hanwoo Steers (답리작 재배 청보리 사일리지 급여가 거세 한우의 증체, 사료요구량 및 육질에 미치는 영향)

  • Seo, Sung;Kim, Won-Ho;Kim, Jong-Geun;Choi, Gi-Jun;Kim, Ki-Yong;Cho, Won-Mo;Park, Beom-Young;Kim, Young-Hoon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.30 no.3
    • /
    • pp.257-266
    • /
    • 2010
  • This study was carried out to investigate the effect of feeding whole crop barley silage (WBS) on the growth performance, gain, feed requirement, carcass grade and beef quality of Hanwoo steers in 1999 to 2001. Twenty one steers were allocated, and divided into three treatment groups which fed rice straw only (control), WBS only, and fresh rice straw silage plus WBS during overall period ad libitum. Concentrates were fed at 1.5% level of live-body weight during growing stages, 4~12 months of age, at 1.8% level of live-body weight during early fattening stages, 13~18 months of age, and ad libitum after late fattening stages, 19~27months of age. The production yields of WBS were 17,135 kg as a silage, and 6,011 kg as a dry matter per ha, and the quality of WBS was 2~3 grade, while that of rice straw silage was 4grade. The daily gain with feeding of WBS (0.70 kg) during experimental period was higher than that of control group (0.65 kg), and the concentrate requirement (7.31 kg) per kg gain in WBS was lower than that of control (8.95 kg). The effects of gain and feed efficiency were very distinct during growing stage. i.e., the daily gain of WBS (0.84 kg) was increased by 65% compared to control (0.51 kg), and the concentrate requirement (4.16 kg) per kg gain in feeding of WBS was decreased by 35%, compared to control (6.39 kg). Meat quality with WBS was higher than that of control. Frequency rate of 1 and/or $1^+$ grade, and marbling score of feeding of WBS were 62.5% and 4.38, while those of control were 37.5% and 2.75, respectively. The results of the sensory evaluation showed that Hanwoo beef fed with WBS were better than that of control. In conclusion, feeding of WBS was desirable to improve daily gain, reduction of concentrates, feed efficiency and meat quality of Hanwoo steers.

Effects of Different Energy and Protein Level of TMR on Milk Production of Dairy Goats in Early Lactation (TMR의 에너지 및 단백질 수준이 비유초기 유산양의 유생산성에 미치는 영향)

  • Ki, Kwang-Seok;Lee, Hyun-June;Kim, Sang-Bum;Lee, Wang-Shik;Lim, Dong-Hyun;Lim, Hyun-Joo;Park, Sung-Jai;Cho, Won-Mo;Kim, Hyeon-Shup;Jin, Ze-Lin;Lee, In-Duk;Kim, Wan-Young;Jeo, Joon-Mo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.30 no.3
    • /
    • pp.267-274
    • /
    • 2010
  • The objective of this experiment was to investigate effects of total mixed ration (TMR) of different nutrition level on milk production in dairy goats (Sannen). Twenty four lactating goats were randomly assigned to one of four TMRs; medium energy-medium crude protein (CP) TMR (control), high energymedium CP TMR (T1), medium energy-high CP TMR (T2) and high energy-high CP TMR (T3). The content of total digestible nutrients (TDN) and CP in the control diet were 67.0% and 13.9%. The TDN content of the high energy TMR was 73.7% and the CP content of the high CP TMR was 15.3%. Milk yield was significantly (P<0.05) higher for T1 ($2,198{\pm}115 ml$) than for T2 ($1,742{\pm}52 ml$) and T3 ($1,984{\pm}90 ml$). But there were no significant differences in milk composition between the treatments. Daily body weight gain was increased in T1 and T3 but reduced in control and T2. The result of the present study showed that dietary energy level supplied more than that of NRC recommendation did not affect milk yield of dairy goats in early lactation but prevented body weight loss.

Comparison of Growth Characteristics and Yield of Silage Corn Hybrids by Different Planting Dates at Paddy and Upland Field (논과 밭에서 파종기에 따른 사일리지용 옥수수의 일반생육 및 수량 비교)

  • Son, Beom-Young;Kim, Jung-Tae;Lee, Jin-Seok;Baek, Seong-Bum;Kim, Wook-Han;Kim, Jong-Duk
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.30 no.3
    • /
    • pp.237-246
    • /
    • 2010
  • This study was conducted to evaluate growth characteristics and yield of silage corn hybrids by different planting dates at paddy and upland field. Days to silking by different planting dates at paddy field were 81 days at planting on April 22, 70 days on May 20 and 62 days on June 10, respectively, and they were getting shorter as planting date delayed. There was no significant difference in days to silking between paddy and upland field. Plant height in paddy field was no significant difference between at planting on April 22 and on May 20, and it was shortened sharply at planting on June 10. There was no significant difference in plant height between paddy and upland field. There was no significant difference in lodging by different planting dates in paddy field. There was significant difference in lodging between paddy and upland field (P<0.05). There was no significant difference in stay-green by different planting dates in paddy field, and no significant difference between paddy and upland field. Ear ratios to total dry matter in paddy field were 43% at planting on April 22, 41% on May 20 and 28% on June 10, respectively, and it was lower as planting date delayed. There was no significant difference in ear ratios to total dry matter between paddy and upland field. Fresh yields in paddy field were lower with 14% at planting on May 20 and 32% on June 10 compared to on April 22 as planting date delayed. There was no significant difference in fresh yield between paddy and upland field. Dry matter yields in paddy field were higher with 9% at planting on May 20 and lower with 24% on June 10 compared to at planting on April 22 as planting date delayed. Dry matter yield in paddy field was lower with 9% compared to 1,931 kg/10a at planting on April 22. TDN (Total digestible nutrients) yields in paddy field were higher with 5% at planting on May 20 and lower with 28% on June 10 compared to at planting on April 22 as planting date delayed. TDN yield in paddy field was lower with 11% compared to 1,340kg/10a at planting on April 22.

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.