• Title/Summary/Keyword: [noise]

Search Result 32,225, Processing Time 0.048 seconds

A Evaluation Study on Reduction Method of Floor Impact Noise through Field Test and the Effective Method for Heavy Impact Noise (현장실험을 통한 바닥충격음 저감공법의 성능평가 및 중량충격음 저감 방안)

  • Lee, Byung-Kwon;Bae, Sang-Hwan;Hong, Cheon-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.451-456
    • /
    • 2004
  • In this study, evaluation was carried out for reduction method of floor impact noise through field test and the effective methods for heavy impact noise were proposed. As a field test, impact noise reduction materials such as EPP, EEPS, EVA, PE and so on, did not satisfied the recommandation value at the condition of 150mm thickness concrete slab. The evaluation results for those materials by 'inverse A curve' showed $53\sim55dB$ at heavy impact noise and $53\sim58dB$ at light impact noise. But, two methods proposed by authors were evaluated $47\sim50dB$ at heavy Impact noise and $54\sim58dB$ at light Impact noise on the similar concrete slab thickness.

  • PDF

Study on Effective Noise Management Plan of Construction Site (건설공사장의 효율적인 소음관리방안을 위한 연구)

  • Sun, Hyo-Sung;Park, Young-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.176-183
    • /
    • 2009
  • The objective of this study is to prepare the plans for managing construction noise effectively and solving the popular enmity from construction noise reasonably. In order to carry out this purpose, it covers the efficient improvement plans for adjusting the construction noise regulation standard rationally and managing the automatic noise measuring system which shows the advantage for construction noise management and popular enmity solution due to construction noise. The three alternative plans of the construction noise regulation standard and the recommendation plan including the guideline for installing and managing the automatic noise measuring system are suggested consequently.

Transfer Path Analysis of Output Noise Using Multi-dimensional Spectral Analysis Method for Vacuum Cleaner (다차원 스펙트럼 해석법을 이용한 진공청소기 출력소음의 전달경로 해석)

  • Jeong, Jae-Eun;Lee, Jung-Hwan;Chung, Chang-Ook;Hwang, Geun-Bae;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.940-945
    • /
    • 2010
  • Noise reduction of vacuum cleaner is important, according as get into standard that estimate quality of product. To reduce noise of vacuum cleaner, we need analysis of correct noise source and contribution grasping about Identified noise sources' output noise. Because noise sources' correlation exists in vacuum cleaner that is small and complicated system, analysis is not easy. In this case, we need to apply Multi-dimensional spectral analysis(MDSA) method that can remove correlation between noise sources and grasp pure contribution degree of noise sources. In this study, we take transfer path analysis between output noise and noise that measured in inside/outside of vacuum cleaner.

A Study on Noise Reduction for the Driving System of a Forklift (지게차 구동부의 소음 진동 저감에 대한 연구)

  • Kim, Woo-Hyung;Hong, Il-Hwa;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.80-86
    • /
    • 2008
  • In this study. the noise sources were identified and the noise and vibration were reduced for an industrial forklift. To identify the noise sourses, noise signals were measured by a microphone on a driver seat and these signals were analyzed with a waterfall plot. For this purpose, the gear mesh frequencies from the gear box of a reducer were not only investigated but noise/vibration sourses of an electric motor were also examined. Furthermore, the frequency response functions were obtained to confirm the vibration and noise sourses. It was found that severe vibration and noise were generated in the casing and the connecting part of the reducer. The severe vibration and noise could be reduced by a structure modification.

Noise Reducers Effect on Road Traffic Noise (소음저감장치의 도로변 설치 효과 분석)

  • Hong, Yun-H.;Kim, Jeung-T.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.207-212
    • /
    • 2007
  • Community noise has been great concerned in public. The traffic noise in seoul, especially has been growing awareness for the quiet living environment. In this paper, the effect on the noise barrier in order to reduce highway noise near on the street has been examined. First barriers have been evaluated at 5 locations in the city. The evaluation is performed before and after construction, with the reference point which does not affected on road traffic volume. Then, noise reducers mounted on the harriers also have been examined. the result shows that it reduces noise level by $3{\sim}3.5dB(A)$ with a standard deviation of 2.8 dB(A).

An analysis of the pass-by noise reduction for KTX by noise reduction device (소음저감 장치에 의한 KTX 차량의 운행소음 저감량 분석)

  • S. S. Jung;Kim, Y. T.;B. S. Jeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.376.1-376
    • /
    • 2002
  • Reduction of the propagation noise generated during pass-by of KTX by noise barrier was measured and analysed fur the two kinds of top-shaped noise reduction devices; one as a plywood board and the other as a PVC pipe were placed periodically. The height and length of reference noise barrier are 2.4 m and 50 m, respectively. The noise reduction with and without noise reduction devices was investigated. (omitted)

  • PDF

Adaptive Switching Filtering Algorithm for SAP noise (SAP 잡음 제거를 위한 적응적 스위칭 필터링 알고리즘)

  • Kim, Donghyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.1
    • /
    • pp.25-35
    • /
    • 2022
  • The SAP(salt-and-pepper) noise changes the pixel value to the maximum and minimum values of the dynamic region of the pixel. For this reason, unlike white Gaussian noise, SAP noise can predict the ratio of noise relatively easily. Because the condition of the neighboring pixels that can be referenced changes according to the noise ratio, it is necessary to apply different noise reduction methods according to the noise ratio. This paper proposes an adaptive switching filtering algorithm which can eliminates the SAP noise. It consists of two phases. It first detects the location of the SAP noise and calculates the noise ratio. After that, the image is reconstructed using different methods depending on which of the three sections the calculated noise ratio belongs to. As a result of the experiment, the proposed method showed superior objective and subjective image quality compared to the previous methods such as MF, AFSWMF, NAMF and RWMF.

Novel Calibration Method of Noise Figure Analyzer and Measurement of Noise Correlation Matrix (잡음지수분석기의 새로운 교정방법과 잡음상관행렬 측정)

  • Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.7
    • /
    • pp.491-499
    • /
    • 2018
  • The conventional calibration method for a noise figure analyzer is to use a noise source. This method is accompanied by a significant irregular ripple in the measurement results, because it does not consider the mismatch of the noise source and noise figure analyzer during calibration. A novel calibration method of the noise figure analyzer is proposed that considers the mismatch between the noise power and noise figure analyzer. A novel noise correlation matrix measurement technique using this method is also proposed. The method determines the noise correlation matrix and the gain of the uncorrected noise figure analyzer using uncorrected noise powers. Then, having determined the gain and noise correlation matrix, the effects of noise figure analyzers were corrected in the measurement results of the noise correlation matrix for the device under test (DUT). Through the proposed method, the measured noise parameters of a DUT showed the same degree of irregular ripples as the result of using the relative noise ratio.

The Evaluation on the Noise Environment of the Low-rise Multi-family house in Athens,U,S,A (미국 Athens 지역 저층 공동주택 소음 환경평가에 관한 연구)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.85-96
    • /
    • 2000
  • The purpose of this study was to evaluated noise environment of the low-rise multi-family house in Athens, Georgia. The results of this study can be applied to the prevention of noise when planning multi-family houses, roads and cities in Korea. The subjects of this study were the place of 1m, 10m, 50m, 100m from 4-lane road ofT apartment and 233 residents lived in the low-rise multi-family houses in Athens. The results of this study were as follows. 1. The average noise level at 1m, 10m, 50m and 100m was 55.5dB, 46.7dB, 43.0dB, 43.0dB and 41.2dB respectively from 4-lane road of T apartment. From the view of the standard in this study, the physical noise was good. 2. The results of the residents subjective response on the noise were as follows. The external noise residents felt - that was a noise by operating machines, and traffic noise - ware as 2.57 on average. The noise by the daily activities, the noise of nature are a little as 2.38 on average. They were disturbed a little by the external noise. They felt the solid born sounds(average 2.49) more than airbone sound(average 2.23) by the internal noise. They are suffered worse from noise in summer and they worse from 8-12 oclock due to external noise and 16-20 oclock due to internal noise. Comparing the noise environment of Korean with that of American, I found a meaningful difference of nature and the noise of daily activities of external noise and all internal noise.

  • PDF

Analysis of frequency characteristics and evaluation methods of elevator noise (승강기 소음의 주파수 특성 분석 및 평가 방법 고찰)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.607-614
    • /
    • 2021
  • Research on elevator noise has mainly focused on the cause of its occurrence and measures to reduce it. There is still insufficient research on how to accurately measure and evaluate elevator noise. There is a measurement method established as an international standard for the measurement method, but it is also difficult to apply to high-rise apartments, and there are many cases that do not closely reflect the characteristics of elevator noise. In order to solve this problem, a study was conducted to improve the elevator noise measurement method in the current standard. In this study, the characteristics of elevator noise were closely identified. Through frequency analysis of the elevator noise and other equipment, it was verified that the elevator noise is noise with different characteristics from other equipment. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. The correlation between bang machine and rubber ball was found to be very high at 0.9 level. As a result, it was verified that the mid-low frequency band of the elevator noise is the main structural transmission noise and cannot be evaluated together with other equipment.