• Title/Summary/Keyword: [noise]

Search Result 32,225, Processing Time 0.051 seconds

Dose-response relationship for annoyance caused by combined noise sources in urban spaces (외부 공간에서 복합소음에 대한 불쾌감 연구)

  • Lee, Pyoung-Jik;You, Jin;Jeong, Choong-Il;Yeon, Jun-Oh;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.264-267
    • /
    • 2008
  • Relationship between exposure to combined noise sources and community annoyance have been investigated. Social surveys were conducted in urban spaces near the construction site with road traffics. The question relating to noise annoyance was answered on an 11-point numerical scale and 5-point verbal scale according to ISO 15666. The questionnaire also contained demographic factors, interference with daily activities, health-related symptoms, and noise sensitivity. Noise levels were measured in terms of A-weighted equivalent level ($L_{Aeq}$), and noise mapping technique was applied to predict the noise levels of urban spaces. Synthesis curves for the relationship between noise levels and percentage highly annoyed for combined noise sources were derived, and compared to the curves from a single noise source.

  • PDF

The Noise property and Its improvement of the Turbo Compressor (터보압축기의 소음특성 및 개선방안)

  • Chun, Kwang-Wook;Shin, Bum-Sik;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.282-287
    • /
    • 2009
  • In this paper, 3-stage centrifugal turbo compressor was measured and analyzed numerical simulation for find noise source and was reduced noise with changing designs. For this purpose, it was measured noise level and was analyzed noise frequency at each stage. In order to Find where is noise source, the study was investigated about structure borne noise by using modal analysis and also was checked sound radiation and leakage of noise at inlet and outlet by result of sound intensity. In order to reduce of noise, sound insulation rings were maded and were adhered at joint and noise reduction effects were verified by measurement and numerical simulation. From the analysis results of leakage of noise, this study presented new joint designs, also it was verified by result of numerical simulation.

  • PDF

A Study on the Noise Property and Its Reduction of the FCEV Blower (FCEV 블로워의 소음특성과 개선방향에 관한 연구)

  • Oh, Ki-Seok;Lee, Sang-Kwon;Seo, Sang-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.516-523
    • /
    • 2008
  • Centrifugal turbo blower is requested highly efficiency and low noise in FCEV, but the noise generated by this machine causes of the most serious problems in the NVH performance. In general, centrifugal turbo blower is dominated by mechanical noise and aerodynamic noise. Mechanical noise is generated by rotation of the bearing, misalignment and unbalance. And aerodynamic noise is generated by the strong intersection between the flow discharged from the impeller and the cut-off in the casing. The first object of this study is to comprehend a noise property of the blower through the noise test. And, second object is to bring up the method that can reduce blower noise.

A Study on the Improvement Plan of Construction Noise Monitoring (공사장 소음모니터링 개선방안에 관한 연구)

  • Park, Young-Min;Kim, Kyoung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1056-1065
    • /
    • 2013
  • Noise generated from Construction site has been raised most civil complaints to 64.4 % among the environmental pollution in 2011. Therefore, local government recommends and prescribes that construction sites over a certain scale install sound level meter for noise monitoring. For example, Seoul has implemented a 24 hour noise monitoring system, with real time communication, to the large construction sites more than 10,000 $m^2$ from the end of August 2012. But it is difficult to use noise measurement data for the construction noise assessment, since the installation standards and technical specifications for construction noise monitoring system are not presented. In this paper, we proposed noise monitoring system improvement plan including technical specifications and installation standards using the investigating results of the problems of current noise monitoring system and the foreign cases.

Sunroof Wind Noise Reduction Using Automatic Noise Measurement and Analysis System (자동 소음 계측 및 분석 장치를 이용한 자동차 썬루프 윈드노이즈 저감 기술 개발)

  • Shin, Seong-Ryong;Kim, Heung-Ki;Jung, Seung-Gyoon;Kook, Hyung-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.166-169
    • /
    • 2005
  • The best sunroof wind noise quality is mainly related to the sunroof deflector which affects both low-speed buffeting and high-speed aerodynamic noise. An automatic deflector-moving and noise-measuring apparatus is developed to obtain hundreds of measuring data which haven't been available by hand. With an additional program for fast and easy noise analysis, this device leads quickly to the better position and angle of the deflector. Now, the 'better' means the lower noise level and the robuster design solution. From these kinds of better solutions, more meaningful guidelines on the deflector design and sunroof wind noise reduction can be suggested.

  • PDF

Development of Lower Noise Excavator (굴삭기 저소음화 기술개발)

  • Ko, Kyung-Eun;Kim, Young-Hyun;Joo, Won-Ho;Kim, Dong-Hae;Bae, Jong-Gug;Shim,, Jae-Koo;Kang, Jeong-Weon;Son, Deuk-Kyun;Kim, Choon-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.156-160
    • /
    • 2005
  • The radiated noise of the excavator is composed of the various noise sources such as the diesel engine, cooling fan and hydraulic system, so the noise reduction for each noise source is required. In this study, the source contribution analysis for these principal noise sources is performed by using the noise source removal method. And to reduce the noise due to each one, the various experiments and analyses are studied. On the basis of these results, the proper reduction countermeasures are derived to develop the excavator satisfied the $2^{nd}$ noise regulation of EU.

  • PDF

Psvchoacoustical Evaluation of Floor Impact Noise (바닥충격음의 심리음향학적 평가)

  • 전진용;정정호;조문재
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.253-258
    • /
    • 2001
  • Floor impact noises in apartment buildings have been investigated as they are most annoying in living environment. Several experiments were undertaken to compare perceived noisiness of floor impact noises generated by bang and tapping machine along with children's jumping and running. Results show that bang noise is more annoying than tapping noise and floor impact noise generated by children is less annoying than the noise generated by machine. The floor impact noise generated by children's jumping and running corresponds well with the bang-machine noise in terms of loudness, unbiased annoyance, ${\Phi}$$\_$0/ and IACC. The noise generated by children is somewhat different from machine noise; in spatial impression the real noise is similar to tapping-machine noise but is less annoying that the machine noises.

  • PDF

A Study on the Noise Reduction of the Engine Cooing Fan of an Express Bus by Change of Design Parameters (설계파라미터 변경에 의한 고속버스용 엔진 냉각 팬의 저소음화 연구)

  • Jae-Eung OH;You-Yub LEE;Hyun-Jin Sim;Mon-Kab Joe
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.333.1-333
    • /
    • 2002
  • This paper suggests the noise reduction method of the engine cooling fan. It was estimated the fannoise contribution at the engine room and identified the noise source at the rotating fan by sound intensity method, first. And it has been developed the program for predicting the noise spectrum of axial flow fan. The radiated acoustic pressure is expressed the discrete frequency noise peaks at BPF and its harmonics and the line spectrum at the broad band by the noise generation mechanisms. In this paper it is shown that the comparison of the measuted and calculaed noise spectra of fn for the validation of the noise predictiong program. And this paper presents the characteristics of a fan noise due to modify the design parameters. Accordingly, it was obtained the design parameter values for noise reduction of fan.

  • PDF

Study on Establishment of Aircraft Noise Abatement Procedures in Kimhae International Airport (김해국제공항 항공기 저소음 운항절차 수립을 위한 연구)

  • Kim, Yeon-Myung;Kim, Mi-Seon;Son, Jeong-Gon;Kim, Young-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.899-903
    • /
    • 2008
  • The purpose of this study is to establish the noise abatement procedures in Kimhae International Airport and also make noise limit and methods to monitor and detect an aircraft flying over Kimhae airport. First of all, noise monitoring system(NMS) should be set up, have a test and noise limit will be adjusted afterwards. Before applying Noise Abatement Procederes and noise limit, the amendment of Aviation Law 'article 108' required to proceed. The accumulative data and long term process of NMS will proceed and it is necessary to issue a notification of noise limit in phases.

  • PDF

An Experimental Study on the Establishment of Indoor Noise Criteria - Focused on Korean Complex Building- (실내 소음기준 설정에 관한 실험적 연구 -동일 건물내 사업장을 중심으로-)

  • Lee, Tai-Gang;Kook, Chan;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.9-12
    • /
    • 2008
  • There are many place of business in complex building, and recently claims of noise have increased in those buildings. It is most desirable reducing the noise problems to establish the noise criteria considering the noise source and the receiving place of business, which are derived from the dose-response of noise and results of the actual condition. The degree of response to the transmission noise could be changed with background noise level in the receiving stores. In this research, the subjective evaluation for three different background level in receiving place of business or rooms were investigated from subjective tests. The eight business sound source including aerobic music were used for the test.

  • PDF