• Title/Summary/Keyword:

Search Result 280, Processing Time 0.03 seconds

Analysis of Gas Cooling System for IR Window (적외선 윈도우용 가스식 냉각장치 해석 기법)

  • Hyun, Cheol-Bong;Goo, Nam-Seo;Kim, Jae-Young;Lee, Ho-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.130-137
    • /
    • 2012
  • In this paper, a post-analysis of cooling system for infrared(IR) window was performed based on heating experiment of IR window system. We applied the same experimental conditions to analysis, and then validated the analysis technique by comparing numerical and experimental results. For an analysis software, we used a professional heat/fluid analysis program and the numerical and experimental results were in fairly good agreement. We investigated the effect of thermal transfer between the frame and IR window and also a cooling efficiency between fluid and structure in order to determine the proper parameters for the analysis. In this study, 100 % thermal transfer between the frame and IR window and 30 % cooling efficiency between fluid and structure have been proposed, which can be used in the future conceptual design and analysis of similar IR windows.

Production of Window Motor Assembly Parts in Automotive Body (자동차 전장에서 윈도우 모터 조립 부품의 생산)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.4
    • /
    • pp.29-34
    • /
    • 2012
  • Power window motor assembly including ECU system is important to doors of automobile. This study is done for own development instead of importing of power window motor assembly. This paper is written under five specific subjects. The first, making of prototype sample and analysis of mass-production problem using CAE, the second, design of mass-production mold(2D and 3D), the third, manufacturing of sample mold, the fourth, tryout and measuring of 3 dimensions, the fifth, data analysis and mold modify. In the among them, product sample and analysis of mass-production using CAE, design and manufacture of mass-production mold, and production of sample mold are successfully done. In the results, it is made clear that two cavity and one gate are proper to make a mold of power window motor assembly housing. Besides, it is acquired own technology for mass-production of power window motor.

Effects of View Elements and Window Luminance on Occupants' Seating Preference in a Living Room (창밖의 조망요소와 창면휘도가 재실자의 착석 선호위치에 미치는 영향)

  • Lim, Eunok;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.123-128
    • /
    • 2012
  • A window increases the lighting quality of a space by allowing daylight into the space, and maintains visual contact with the outside. Moreover, the window with a preferred view provides many benefits such as psychological satisfaction, occupants' health and improved environmental quality. This study aimed to investigate how view elements and window luminance influence occupants' seating preference in a living room. The experiment was carried out in a mock-up model with thirty-two subjects (17 men and 15 women). The nine seating positions in a living room have different view such as natural view (trees or sky) and man-made view (paving and roof top). Subjects were asked to select a position in the room where they felt most visual comfort. Simultaneously Photolux 2.1 software was used to analyze the window luminance. The experiment results indicated that subjects prefer to be seated near a window and feel comfort in a seating overlooking the trees and sky. This would indicate that the natural elements of the view and a distance to the window affect seating preference to the occupants.

EU항만의 효율성에 관한 연구 (DEA와 Shannon's Entropy의 통합모형과 DEA-Window 분석을 이용하여)

  • Park, Ho;Kim, Dong-Jin;Kim, Yul-Seong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.10a
    • /
    • pp.109-111
    • /
    • 2012
  • 한-EU FTA 발효 등은 교역 확대가 예상되며, 항만의 역할은 더욱더 중요해 질 것이다. 항만의 성과를 측정할 수 있는 방안으로 DEA를 활용한 효율성 측정을 들 수 있으며, 본 연구에서는 DEA 측정 시 모형 선정의 어려움과 동태적 효율성을 변화를 분석하기 위해 DEA와 Shannon's Entropy 결합모형으로 효율성을 분석하고, DEA-Window 모형으로 동태적 효율변화를 분석하였다.

  • PDF

RTT based TCP Design and Implementation for USN (USN을 위한 RTT 기반 TCP 설계 및 구현)

  • Yi, Hyun-Chul;Choi, Joon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.774-779
    • /
    • 2012
  • We design and implement a RTT (Round Trip Time) based TCP (Transmission Control Protocol) for USN (Ubiquitous Sensor Network). We adopt a basic update algorithm for window size from FAST TCP that uses the queuing delay at link as the congestion measure. The designed TCP estimates the queuing delay at link from the measured RTT in the network layer, and updates the window size based on the estimated queuing delay. The designed TCP allows to utilize the full capacity of USN links and avoids the waste of the given link capacity that is common without the flow control in the transport layer. The experiment results show that the window size of the sender converges within a small range of variations without any packet loss, and verify the stability and performance of the designed TCP.

The Evaluation of Cooling Load by The Window Film Insulation in College Building (대학 건물에 적용한 열 차단 필름이 냉방부하에 미치는 영향 평가)

  • Kim, Seok-Hyun;Kang, Su-Hyun;Yu, Si-Wan;Cho, Young-Hum
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.549-552
    • /
    • 2012
  • Recently the world is trying to reduce carbon emissions for global warming. Reducing use of fossil fuels can decrease carbon emission. In this reason the construction field has tried to reduce the use of fossil fuels relating to heating and cooling of buildings. An energy loss through the window system is about 10 to 30 percent of energy consumption of the whole building. The use of window film insulation is increasing to control the heat loss at the windows. The window film insulation absorbs solar radiation and makes the surface temperature of windows high. In this study, window surface temperature is measured, and an impact on indoor air is identified after attaching window film insulation. Finally, we found that cooling load decreases through simulation.

  • PDF

Active Window system based on Finite Thickness Window Model (유한 두께 창문 모델을 적용한 능동 소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.763-768
    • /
    • 2012
  • Active window system which can reduce the environmental noises, such as traffic noise and construction noise, from an open window into a room was proposed in the previous works. The key idea of the proposed active window system was that the control sources are approximately collocated with the primary noise source in terms of the acoustic power for global noise reduction throughout the interior room. Moreover, because it is important not to intrude into the living space in the building environment, no error sensors were used and an open-loop control method using control sources at the window frame and the reference sensors outside the room was used for the proposed system. The open-loop control gain was calculated by the interior room model assumed as the semi-infinite space, and the interior sound field was estimated by Rayleigh integral equation under the baffled window model assumption. However, windows with a finite thickness should were considered for the calculation of the open-loop control gain of the active window system since these are representative of most window cases. Therefore, the finite thickness window model based on the Sgard's model was derived and the open-loop control gain using the interior sound field estimated by that model was calculated for active window system. To compare the performance of these two models, a scale-model experiment was performed in an anechoic chamber according to noise source directions. Experimental results showed that the performance for the thickness window model is better than the baffled window model as the angle with respect to the perpendicular direction is larger.

  • PDF

The Influence of Design Factors of Sonar Acoustic Window on Transfer Function of Self Noise due to Turbulent Boundary Layer (소나 음향창의 설계 인자가 난류 유동 유기 자체 소음의 전달 함수에 미치는 영향 해석)

  • Shin, Ku-kyun;Seo, Youngsoo;Kang, Myengwhan;Jeon, Jaejin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.568-574
    • /
    • 2012
  • Turbulent boundary layer noise is already a significant contributor to sonar self noise. For developing acoustic window of sonar system to reduce self noise, a parametric study of design factors of acoustic window is presented. Distance of sensor array from acoustic window, material and damping layer are studied as design factors to influence in the characteristics of the transfer function of self noise. As the result these design factors make change the characteristics of transfer function slightly. Among design factors the location of sensor array is most important parameter in the self noise reduction.

  • PDF

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.