• Title/Summary/Keyword: * $_f$-Max(D)

Search Result 163, Processing Time 0.023 seconds

COMPACTNESS OF A SUBSPACE OF THE ZARISKI TOPOLOGY ON SPEC(D)

  • Chang, Gyu-Whan
    • Honam Mathematical Journal
    • /
    • v.33 no.3
    • /
    • pp.419-424
    • /
    • 2011
  • Let D be an integral domain, Spec(D) the set of prime ideals of D, and X a subspace of the Zariski topology on Spec(D). We show that X is compact if and only if given any ideal I of D with $I{\nsubseteq}P$ for all $P{\in}X$, there exists a finitely generated idea $J{\subseteq}I$ such that $J{\nsubseteq}P$ for all $P{\in}X$. We also prove that if D = ${\cap}_{P{\in}X}D_P$ and if * is the star-operation on D induced by X, then X is compact if and only if * $_f$-Max(D) ${\subseteq}$X. As a corollary, we have that t-Max(D) is compact and that ${\mathcal{P}}$(D) = {P${\in}$ Spec(D)$|$P is minimal over (a : b) for some a, b${\in}$D} is compact if and only if t-Max(D) ${\subseteq}\;{\mathcal{P}}$(D).

Balance-Swap Optimization of Economic Load Dispatch Problem using Quadratic Fuel Cost Function (이차 발전비용함수를 사용한 경제급전문제의 균형-교환 최적화)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.243-250
    • /
    • 2014
  • In this paper, I devise a balance-swap optimization (BSO) algorithm to solve economic load dispatch with a quadratic fuel cost function. This algorithm firstly sets initial values to $P_i{\leftarrow}P_i^{max}$, (${\Sigma}P_i^{max}$ > $P_d$) and subsequently entails two major processes: a balance process whereby a generator's power i of $_{max}\{F(P_i)-F(P_i-{\alpha})\}$, ${\alpha}=_{min}(P_i-P_i^{min})$ is balanced by $P_i{\leftarrow}P_i-{\alpha}$ until ${\Sigma}P_i=P_d$; and a swap process whereby $_{max}\{F(P_i)-F(P_i-{\beta})\}$ > $_{min}\{F(P_i+{{\beta})-F(P_j)\}$, $i{\neq}j$, ${\beta}$ = 1.0, 0.1, 0.1, 0.01, 0.001 is set at $P_i{\leftarrow}P_i-{\beta}$, $P_j{\leftarrow}P_j+{\beta}$. When applied to 15, 20, and 38-generators benchmark data, this simple algorithm has proven to consistently yield the best possible results. Moreover, this algorithm has dramatically reduced the costs for a centralized operation of 73-generators - a sum of the three benchmark cases - which could otherwise have been impossible for independent operations.

A Heuristic Algorithm for $n/m/D/F/F_{max}$ (Flow Shop에서 준비시간이 작업순서에 종속적인 경우의 휴리스틱 알고리듬의 개발)

  • 최성운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.8 no.11
    • /
    • pp.79-83
    • /
    • 1985
  • This paper is to develop four heuristic algorithms for $n/m/D/F/F_{max}$. A study present numerical example for (H1) algorithm. Among the sequence generated, the best sequence is J2, J1, J6, J7, J4, J3, J5 and makespan is 528. The optimal makespan of this numerical example can be found as 528 as also, and the worst value of heuristic solution is only 7.2 % away from it.

  • PDF

Dynamic Economic Load Dispatch Problem Applying Valve-Point Balance and Swap Optimization Method (밸브지점 균형과 교환 최적화 방법을 적용한 동적경제급전문제)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.253-262
    • /
    • 2016
  • This paper proposes a balance-swap method for the dynamic economic load dispatch problem. Based on the premise that all generators shall be operated at valve-points, the proposed algorithm initially sets the maximum generation power at $P_i{\leftarrow}P_i^{max}$. As for generator i with $_{max}c_i$, which is the maximum operating cost $c_i=\frac{F(P_i)-F(P_{iv_k})}{(P_i-P_{iv_k})}$ produced when the generation power of each generator is reduced to the valve-point $v_k$, the algorithm reduces i's generation power down to $P_{iv_k}$, the valve-point operating cost. When ${\Sigma}P_i-P_d$ > 0, it reduces the generation power of a generator with $_{max}c_i$ of $c_i=F(P_i)-F(P_i-1)$ to $P_i{\leftarrow}P_i-1$ so as to restore the equilibrium ${\Sigma}P_i=P_d$. The algorithm subsequently optimizes by employing an adult-step method in which power in the range of $_{min}\{_{max}(P_i-P_i^{min}),\;_{max}(P_i^{max}-P_i)\}$>${\alpha}{\geq}10$ is reduced by 10; a baby step method in which power in the range of 10>${\alpha}{\geq}1$ is reduced by 1; and a swap method for $_{max}[F(P_i)-F(P_i-{\alpha})]$>$_{min}[F(P_j+{\alpha})-F(P_j)]$, $i{\neq}j$ of $P_i=P_i{\pm}{\alpha}$, in which power is swapped to $P_i=P_i-{\alpha}$, $P_j=P_j+{\alpha}$. It finally executes minute swap process for ${\alpha}=\text{0.1, 0.01, 0.001, 0.0001}$. When applied to various experimental cases of the dynamic economic load dispatch problems, the proposed algorithm has proved to maximize economic benefits by significantly reducing the optimal operating cost of the extant Heuristic algorithm.

A Swap Optimization for Dynamic Economic Dispatch Problem with Non-smooth Function (비평활 발전비용함수를 가진 동적 경제급전문제의 교환 최적화)

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.11
    • /
    • pp.189-196
    • /
    • 2012
  • This paper proposes Swap algorithm for solving Dynamic Economic Dispatch (DED) problem. The proposed algorithm initially balances total load demand $P_d$ with total generation ${\Sigma}P_i$ by deactivating a generator with the highest unit generation cost $C_i^{max}/P_i^{max}$. It then swaps generation level $P_i=P_i{\pm}{\Delta}$, (${\Delta}$=1.0, 0.1, 0.01, 0.001) for $P_i=P_i-{\Delta}$, $P_j=P_j+{\Delta}$ provided that $_{max}[F(P_i)-F(P_i-{\Delta})]$ > $_{min}[F(P_j+{\Delta})-F(P_j)]$, $i{\neq}j$. This new algorithm is applied and tested to the experimental data of Dynamic Economic Dispatch problem, demonstrating a considerable reduction in the prevalent heuristic algorithm's optimal generation cost and in the maximization of economic profit.

A STUDY ON dmf & PREDILECTION SITES OF PRESCHOOL CHILDREN IN SEOUL. (서울시(市) 미취학아동(未就學兒童)의 dmf 및 치아우식(齒牙齲蝕) 호발부위(好發部位)에 대(對)한 연구(硏究))

  • Ko, Sung-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.8 no.1
    • /
    • pp.103-117
    • /
    • 1981
  • The data about dental caries obtained from 1438 preschool children (male 797, female 641) in Seoul aged from 3 to 6 were analyzed by their sexes, ages, jaws and teeth surfaces. The results were as follows. 1. dmf rate : 92.63% 2. dmft index : 6.06 dmft rate 30.81 % dmfs index : 11.82 dmfs rate 12.02 % 3. d,m & f rate d rate: 79.45% m rate: 8.15% f rate : 12.40 % 4. dft index : 5.94 5. The order of caries susceptible tooth 1. Lower deciduous 2nd molar 2. Lower deciduous 1st molar 3. Upper deciduous 2nd molar 4. Upper deciduous lateral incisor 5. Upper deciduous cental incisor 6. Upper deciduous lateral incisor 7. Lower deciduous canine 8. Upper deciduous canine 9. Lower deciduous central incisor 10. Lower deciduous lateral incisor 6. Predilection sites of each tooth A) Deciduous central incisor ; Max. : Mesial cavity Mand. : Mesio-distal cavity B) Decidous lateral incisor ; Max. : Mesial cavity Mand. : Distal cavity=Mesial cavity C) Deciduous canine; Max. : Labial cavity Mand. : Distal cavity D) Decidous 1st molar ; Max. : Disto-occlusal cavity Mand.: Disto-occlusal cavity E) Deciduous 2nd molar ; Max. : Linguo-occlusal cavity Mand.: Occlusal cavity 7. All the values in caries criteria in 1981 were somewhat lower than in 1968, but m & f rate were increased.

  • PDF

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Bioequivalence of Cefaclor 375 mg SR Tablet (세파클러 375 mg서방정의 생물학적 동등성)

  • Lee, Shin Hwa;Yun, Min Hyuk;Choi, Kyung Eob;Kwon, Kwang Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.13 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • This study was carried out to compare the bioavailability of $Ceclex^{(R)}$ SR TAB (test drug, cefaclor 375 mg/Tablet) with that of Ceclor $MR^{(R)}$ SR IAB (reference drug) and to estimate the pharmacokinetic parameters of cefaclor in healthy Korean volunteers. The bioavailability was examined on 24 healthy volunteers who received a single dose (375 mg) of each drug in the fasting state in a randomized balanced 2-way crossover design. After dosing, blood samples were collected for a period of 7 hours. Plasma concentrations of cefaclor were determined using HPLC with UV detection. The pharmacokinetic parameters $(AUC_{0-7h},\;C_{max},\;T_{max},\;AUC_{inf},\;K_e,\;t_{1/2},\;V_d/F,\;and\;CL/F)$ were calculated with non-compartmental pharmacokinetic analysis. The ANOVA test was utilized for the statistical analysis of the $T_{max}$, log-transformed $AUC_{0-7h$}$, log-transformed $C_{max},\;t_{1/2},\;V_d/F$, and $CL/F$. The ratios of geometric means of $AUC_{0-7h}\;and\;C_{max}$ between test drug End reference drug were $95.67\%\;(8.55\;vs\;8.18{\mu}g{\cdot}hr/ml)\;and\;103.86\%\;(2.85\;vs\;2.96{\mu}g/ml)$, respectively. The $T_{max}$ of test drug and reference drug was $2.56\pm0.15\;and\;2.23\pm0.13\;hrs,\;respectively.\;The\;90\%$ confidence intervals of mean difference of logarithmic transformed $AUC_{0-7h}\;and\;C_{max}$ were log0.90-log1.04 and log0.91-log1.13, respectively. It shows that the bioavailability of test drug is equivalent with that of reference drug.

  • PDF

Classification of Seismic Stations Based on the Simultaneous Inversion Result of the Ground-motion Model Parameters (지진동모델 파라미터 동시역산을 이용한 지진관측소 분류)

  • Yun, Kwan-Hee;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.183-190
    • /
    • 2007
  • The site effects of seismic stations were evaluated by conducting a simultaneous inversion of the stochastic point-source ground-motion model (STGM model; Boore, 2003) parameters based on the accumulated dataset of horizontal shear-wave Fourier spectra. A model parameter $K_0$ and frequency-dependent site amplification function A(f) were used to express the site effects. Once after a H/V ratio of the Fourier spectra was used as an initial estimate of A(f) for the inversion, the final A(f) which is considered to be the result of combined effect of the crustal amplification and loca lsite effects was calculated by averaging the log residuals at the site from the inversion and adding the mean log residual to the H/V ratio. The seismic stations were classified into five classes according to $logA_{1-10}^{max}$(f), the maximum level of the site amplification function in the range of 1 Hz < f < 10 Hz, i.e., A: $logA_{1-10}^{max}$(f) < 0.2, B: 0.2 $\leq$ $logA_{1-10}^{max}$(f) < 0.4, C: 0.4 $\leq$ $logA_{1-10}^{max}$(f) < 0.6, D: 0.6 $\leq$ $logA_{1-10}^{max}$(f) < 0.8, E: 0.8 $\leq$ $logA_{1-10}^{max}$(f). Implication of the classified result was supported by observing a shift of the dominant frequency of average A(f) for each classified stations as the class changes. Change of site classes after moving seismic stations to a better site condition was successfully described by the result of the station classification. In addition, the observed PGA (Peak Ground Acceleration)-values for two recent moderate earthquakes were well classified according to the proposed station classes.

Analysis of characteristics of PHEMT's with gate recess etching method (게이트 리세스 식각 방법에 따른 PHEMT 특성 변화)

  • 이한신;임병옥;김성찬;신동훈;전영훈;이진구
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.249-252
    • /
    • 2002
  • we have studied the characteristics of PHEMT's with gate recess etching method. The DC characterization of PHTMT fabricated with the wide single recess methods is a maximum drain current density of 319.4 ㎃/mm and a peak transconductance of 336.7 ㎳/mm. The RF measurements were obtained in the frequency range of 1~50GHz. At 50GHz, 3.69dB of 521 gain were obtained and a current gain cut-off frequency(f$_{T}$) of 113 CH and a maximum frequency of oscillation(f$_{max}$) of 172 Ghz were achieved from this device. On the other hand, a maximum drain current of 367 mA/mm, a peak transconduclancc of 504.6 mS/mm, S$_{21}$ gain of 2.94 dB, a current gain cut-off frequency(f$_{T}$) of 101 CH and a maximum frequency of oscillation(f$_{max}$) of 113 fa were achieved from the PHEMT's fabricated by the .narrow single recess methods.methods.

  • PDF