• 제목/요약/키워드: (reinforcement and reduction method)

검색결과 164건 처리시간 0.029초

Design for earthquake-resistant short RC structural walls

  • Zygouris, Nick St.;Kotsovos, Gerasimos M.;Kotsovos, Michael D.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.713-732
    • /
    • 2015
  • The application of the compressive force path method for the design of earthquake-resistant reinforced concrete structural walls with a shear span-to-depth ratio larger than 2.5 has been shown by experiment to lead to a significant reduction of the code specified transverse reinforcement within the critical lengths without compromising the code requirements for structural performance. The present work complements these findings with experimental results obtained from tests on structural walls with a shear span-to-depth ratio smaller than 2.5. The results show that the compressive force path method is capable of safeguarding the code performance requirements without the need of transverse reinforcement confining concrete within the critical lengths. Moreover, it is shown that ductility can be considerably increased by improving the strength of the two bottom edges of the walls through the use of structural steel elements extending to a small distance of the order of 100 mm from the wall base.

고강도 콘크리트 말뚝과 기초판 접합부의 최적 철근보강량 산정 (Assessment of Optimum Reinforcement of Rebar for Joint of PHC Pile and Foundation Plate)

  • 박종배;심영종;천영수;박성식;박용부
    • 토지주택연구
    • /
    • 제1권1호
    • /
    • pp.67-73
    • /
    • 2010
  • PHC 말뚝에서 강선을 노출시켜 건축물의 기초판과 연결시키는 기존 강선남김 방식은 강결합과 힌지결합의 중간형태로 공동주택(아파트)과 같은 건축구조물에 흔히 사용되는 방법이다. 그러나 이 방법은 역학적인 성능이 검증되지 않았으며 시공과정도 복잡하다. 이에 본 연구는 기존 관련 연구의 결과를 분석하고, PHC 말뚝의 콘크리트 단면적 대비 강선면적 비인 0.3%를 말뚝 접합부의 최소 철근보강량으로 선정하여 PHC 말뚝과 기초판과의 최적의 철근보강 방법을 말뚝 규격별(PHC 450, PHC 500, 및 PHC 600)로 제시하였다. PHC 말뚝과 기초판 접합부의 역학적 성능(인장강도와 전단강도)을 평가하기 위해 실물크기의 실험을 실시하였다. 그 결과, 모든 경우에 대해 요구강도를 만족하였으며 실제 적용되어도 문제가 없음을 확인하였다. 본 결과는 기존 연구에서 제시되었던 접합부의 철근 보강량보다 그 양이 대폭 감소하는 것으로 나타나 PHC 말뚝 시공 시 원가 절감에도 기여할 것으로 판단된다.

이암지역에 근입된 PRD강관말뚝의 지지력 보강 (Reinforcement for Bearing Capacity of PRD Steel Pile at Mudstone Area)

  • 공진영;강희진;천병식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1760-1769
    • /
    • 2007
  • The cut slope sliding which has been frequently encountered in Pohang area has been reported due to the rapid reduction of shear strength in mudstone after being exposed to the air. Mudstone has characteristics that it has high enough strength and stiffness in a dry condition, but the strength and stiffness decrease in a wet condition with groundwater infiltration. The case study in this paper shows that mudstone which had enough strength in a boring stage has lost the strength after installing PRD steel pipe pile inducing an insufficient bearing capacity, which has been ascertained by the static load test. Test construction has been performed to investigate the most favorable method for increasing a pile bearing capacity in mudstone with various methods such as MSG (Micro Silica Grouting) around the tip and side of a pile, the perimeter grouting combined with Micro pile reinforcement, and concrete filling after tip reinforcing grouting. From the test construction, MSG has been turned out to be the most favorable method for increasing a pile bearing capacity in mudstone, which has been confirmed by the static load test.

  • PDF

탄소섬유시트에 의한 콘크리트 보의 휨보강효과에 관한 실험연구 (An Experimental Study on Flexcural Performance of Repaired R/C Beams with CFS)

  • 이리형;이용택;김승훈;강윤구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.605-610
    • /
    • 1997
  • An experimental investigation was conducted to examine the feasibility of Carbon Fiber Sheet(CFS), a kind of high strength fiber, for a repair and reinforcement method of concrete structures. The experimental program included tests of flexural beams different in wrapping method and amount of CFS. The beams were subjected to monotonic loading. Although the flexural strength for concrete members increases with wrapping methods of CFS., the reduction factor due to the distribution, amount bond of CFS should be completely examined. This study approached the effectiveness and application of CFS, along with reinforcement effects of CFS on reinforced concrete beams through tests. Test results indicated that the increase in the number of CFS layer caused the increase in strength of beams in strength.

  • PDF

Three-dimensional free vibration analysis of cylindrical shells with continuous grading reinforcement

  • Yas, M.H.;Garmsiri, K.
    • Steel and Composite Structures
    • /
    • 제10권4호
    • /
    • pp.349-360
    • /
    • 2010
  • Three dimensional free vibrations analysis of functionally graded fiber reinforced cylindrical shell is presented, using differential quadrature method (DQM). The cylindrical shell is assumed to have continuous grading of fiber volume fraction in the radial direction. Suitable displacement functions are used to reduce the equilibrium equations to a set of coupled ordinary differential equations with variable coefficients, which can be solved by differential quadrature method to obtain natural frequencies. The main contribution of this work is presenting useful results for continuous grading of fiber reinforcement in the thickness direction of a cylindrical shell and comparison with similar discrete laminate composite ones. Results indicate that significant improvement is found in natural frequency of a functionally graded fiber reinforced cylinder due to the reduction in spatial mismatch of material properties and natural frequency.

삼각망 철근상세를 갖는 현장타설 및 조립식 중공 철근콘크리트 교각의 비선형 지진해석 (Nonlinear Seismic Analysis of Hollow Cast-in-place and Precast RC Bridge Columns with Triangular Reinforcement Details)

  • 김태훈;나경웅;이재훈;신현목
    • 콘크리트학회논문집
    • /
    • 제28권6호
    • /
    • pp.713-722
    • /
    • 2016
  • 이 연구는 지진하중을 받는 현장타설 및 조립식 물량저감 중공 철근콘크리트 교각의 내진성능을 파악하는데 그 목적이 있다. 개발된 물량저감 삼각망 철근상세는 경제적이고 합리적이며 공사기간을 단축할 수 있다. 정확하고 올바른 성능평가를 위하여 신뢰성 있는 비선형 유한요소해석 프로그램을 사용하였다. 이용된 해석기법은 조사된 중공 교각 실험체에 대하여 입력지진파에 따라 내진성능을 비교적 정확하게 예측하였다. 그 결과 개발된 삼각망 물량저감 철근상세는 기존 철근상세와 동등 이상의 소요성능을 보임을 확인하였다.

삼각망 철근상세를 갖는 중실 철근콘크리트 기둥의 성능평가 (Performance Assessment of Solid Reinforced Concrete Columns with Triangular Reinforcement Details)

  • 김태훈;이승훈;이재훈;신현목
    • 콘크리트학회논문집
    • /
    • 제28권1호
    • /
    • pp.75-84
    • /
    • 2016
  • 이 연구의 목적은 삼각망 철근상세를 갖는 중실 철근콘크리트 기둥의 성능을 파악하는데 있다. 제안된 철근상세는 경제성과 합리성을 갖으며 공사기간의 단축을 가져올 수 있다. 삼각망 철근상세를 갖는 중실 철근콘크리트 기둥 실험체에 일정 축하중 하에서 횡방향 반복하중을 가하는 준정적 실험을 수행하였다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST이다. 사용된 해석기법은 조사된 실험체에 대하여 하중단계에 따라 성능을 비교적 정확하게 예측하였다. 그 결과 제안된 삼각망 철근상세는 기존 철근상세와 동등 이상의 소요성능을 보임을 확인하였다.

MLPP 공법의 압밀 및 지지력 특성에 관한 실험적 연구 (Experimental Study on Consolidation and Bearing Capacity Characteristics of Marine Large Pack Pile)

  • 이상익;박용원;임철웅;김일곤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.272-279
    • /
    • 2005
  • This paper introduces a new method of improvement for marine soft ground, MLPP(Marine Large Pack Pile). The MLPP is a reinforcement technique for the conventional SCP or GCP piles by confining with geotextile pack. A pilot project at Busan New Port site and laboratory model tests were carried out to investigate the settlement reduction and bearing capacity enhancement effect of pack pile. The results of field and laboratory tests show that MLPP method can be a safe and economic alternative method for SCP and GCP.

  • PDF

지오텍스타일 매트의 설치에 의한 개착식 터널 라이닝에 작용하는 토압의 변화 (Variation of Earth Pressure Acting on the Cut-and-Cover Tunnel Lining due to Geotextile Mat Reinforcement)

  • 펄디난드 이 바우티스타;박이근;임종철;주인곤
    • 한국지반공학회논문집
    • /
    • 제23권3호
    • /
    • pp.25-40
    • /
    • 2007
  • 얕은 터널의 개착식 터널 라이닝에 발생하는 과잉토압은 라이닝의 변형과 손상을 유발하는 역학적 주요인자들 중의 하나이며(Kim, 2000), 과잉토압은 되메움토의 다짐불량, 자중에 의한 압밀, 강우의 침투에 의한 다짐, 차량에 의한 진동 등에 의해 발생할 수 있다(Komiya et al., 2000; Taylor et al., 1984; Yoo, 1997). 터널 라이닝에 발생하는 토압을 구하기 위한 많은 시험이 행해졌지만, 부등침하와 과잉토압을 줄일 수 있는 보강대책을 수립하기 위한 사례는 없다. 본 연구는 모래 지반에 $1.0D\sim1.5D$ 깊이에 개착식으로 시공하는 원형의 강성 터널에 작용하는 토압에 관한 것으로 진동다짐의 영향을 모형실험에서 충분히 반영하기 위하여 100Hz의 진동주파수를 사용하였다. 본 연구에서는 개착식 터널 라이링에 작용하는 부등침하와 과잉토압을 줄이기 위해서 지오텍스타일 매트를 설치하였다. 지오텍스타일 매트의 보강에 의한 부등침하와 토압의 감소효과를 확인하기 위해 실내모형실험을 수행하였다. 실내모형실험에서 토피, 매트 보강형태, 절취면의 거칠기 등을 달리하여 가장효과적인 방법을 구하였다. 절취면의 거칠기 달리하기 위해 사면에 사포#100, 사포#400과 acetate 부착하였습니다. 무보강과 매트 보강에 대한 모형실험을 실시하여 구한 토압을 비교하여 매트 보강효과를 살펴보았으며, 사진분석법(Park, 2003)을 이용하여 지반의 변형을 분석하였다.

띠형 섬유보강재의 장기성능 평가를 위한 실험적 연구 (Experimental Study on Long-Term Performance Evaluation of Geosynthetic Strip Reinforcement)

  • 이광우;김주형;조삼덕;한중근;윤원일;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제9권4호
    • /
    • pp.75-84
    • /
    • 2010
  • 본 연구에서는 띠형 섬유보강재의 인장특성, 크리프 변형, 내시공성 및 내구성을 평가하기 위한 일련의 장기성능 평가시험을 수행하였다. 또한 시험결과를 바탕으로 장기설계인장강도 산정을 위한 강도감소계수를 평가하였다. 먼저, 크리프 변형 특성을 평가하기 위해 단계 등온법과 시간-온도 중첩법을 이용하였으며, 크리프 감소계수는 1.6을 적용하는 것이 바람직한 것으로 평가되었다. 다음으로 입도 조정된 화강풍화토를 성토재로 사용하여 수행한 내시공성 시험 결과, 보강재의 강도특성에 영향을 미치는 원사의 손상이 거의 없는 것으로 확인되어, 장기설계인장강도에 큰 영향을 미치지 않을 것으로 분석되었다. 마지막으로 내구성 평가 결과, 내화학성, 내미생물 및 내후성을 고려한 강도감소계수는 1.1을 적용하는 것이 합리적인 것으로 평가되었다.

  • PDF