• Title/Summary/Keyword: (n,k) code

Search Result 618, Processing Time 0.03 seconds

Overview on Standards for Liquefaction Triggering Evaluation using the Simplified Method (간편법을 이용한 액상화 평가 기준에 대한 고찰)

  • Kim, Yeon-Jun;Ko, Kil-Wan;Manandhar, Satish;Kim, Byungmin;Kim, Dong-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.197-209
    • /
    • 2020
  • Evidence of liquefaction during the 2017 Pohang earthquake has highlighted the urgent need to evaluate the current seismic design standard for liquefaction in Korea, particularly the liquefaction triggering standard. With the simplified method, which is the most popular method for evaluating liquefaction triggering, the factor of safety for liquefaction triggering is calculated via the cyclic stress ratio (CSR) and the cyclic resistance ratio (CRR). The parameters in the CSR and CRR have undergone changes over time based on new research findings and lessons learned from liquefaction case-histories. Hence, the current design standard for liquefaction triggering evaluation in Korea should also reflect these changes to achieve seismic safety during future earthquakes. In this study, liquefaction susceptibility criteria were discussed initially and this was followed by a review of the current liquefaction triggering codes/guidelines in other countries and Korea. Next, the parameters associated with the CSR such as the maximum ground acceleration, stress reduction factor, magnitude scaling factor, and overburden correction factor were discussed in detail. Then, the evaluation of the CRR using the SPT N-value and CPT qc-value was elaborated along with overburden and clean-sand correction factors. Based on this review of liquefaction triggering evaluation standards, recommendations are made for improving the current seismic design standard related to liquefaction triggering in Korea.

Detailed Abundance Analysis for Plant Host Stars

  • Kang, Won-Seok;Lee, Sang-Gak;Kim, Kang-Min
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.27.1-27.1
    • /
    • 2011
  • We obtained the spectra of 93 Planet host stars and 73 normal field stars in F, G, K type using BOES at BOAO. We measured the equivalent width of Fe and 25 elements lines using the automatic EW measurement program, TAME(Tools for Automatic Measurement of Equivalent-widths) and estimated the elemental abundances by synth and abfind driver of MOOG code. Since the absence of planets in the normal field stars cannot be "completely" proved, this work focused on the chemical abundances and planet properties of planet host stars, which have the massive planets close to the parent star relatively. We carried out an investigation for the difference of abundances between stars with "Hot Jupiter" and normal field stars with no known planets. We examined the chemical composition of 25 elements, such as C, N, O, S, Na, Mg, Al, Si, K, Ca, Sc, Ti, V, Cr, Mn, Co, Ni, Cu, Zn, Sr, Y, Zr, Ba, Ce, Nd, and Eu by EW measurements, and the S abundances were estimated using synthetic spectrum. We have found that [Mg/Fe] and [Al/Fe] for planet host stars have lower limit comparing with those of comparison stars, and [Ca/Fe] of host star with Neptunian planets is relatively lower than the other host stars with massive planets. We have performed the Kolmogorov-Smirnov test, and examined the ratio of planet host stars to all stars for each bin of [X/H]. As a result, we noted that the O, Si, and Ca abfor undances are strongly related with the presence of planets.

  • PDF

Feasibility study of a dedicated nuclear desalination system: Low-pressure Inherent heat sink Nuclear Desalination plant (LIND)

  • Kim, Ho Sik;NO, Hee Cheon;Jo, YuGwon;Wibisono, Andhika Feri;Park, Byung Ha;Choi, Jinyoung;Lee, Jeong Ik;Jeong, Yong Hoon;Cho, Nam Zin
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.293-305
    • /
    • 2015
  • In this paper, we suggest the conceptual design of a water-cooled reactor system for a low-pressure inherent heat sink nuclear desalination plant (LIND) that applies the safety-related design concepts of high temperature gas-cooled reactors to a water-cooled reactor for inherent and passive safety features. Through a scoping analysis, we found that the current LIND design satisfied several essential thermal-hydraulic and neutronic design requirements. In a thermal-hydraulic analysis using an analytical method based on the Wooton-Epstein correlation, we checked the possibility of safely removing decay heat through the steel containment even if all the active safety systems failed. In a neutronic analysis using the Monte Carlo N-particle transport code, we estimated a cycle length of approximately 6 years under 200 $MW_{th}$ and 4.5% enrichment. The very long cycle length and simple safety features minimize the burdens from the operation, maintenance, and spent-fuel management, with a positive impact on the economic feasibility. Finally, because a nuclear reactor should not be directly coupled to a desalination system to prevent the leakage of radioactive material into the desalinated water, three types of intermediate systems were studied: a steam producing system, a hot water system, and an organic Rankine cycle system.

Moire Interferometry Measurement and Numerical Analysis for Hygroscopic Swelling of Al-Polymer Joint (Al-Polymer 접합체의 흡습팽창에 대한 모아레 간섭 측정 및 수치해석)

  • Kim, Kibum;Kim, Yong-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3442-3447
    • /
    • 2014
  • A simple method to evaluate the hygroscopic characteristics of polymer of microelectronic plastic package is suggested. To evaluate the characteristics, specimens were prepared, and the internally absorbed moisture masses were measured as a function of the absorbing time and calculated numerically. The hygroscopic pressure ratio was calculated by heat transfer analysis supported by commercial FEM code because the hygroscopic diffusion equation has the same form as the heat transfer equation. The moisture masses were then summed by the self developed code. The nonconductive polymers had quite different characteristics for the different lots, even though they were the same products. The absorbed moisture mass variations were calculated for several different characteristics, and the optimal curve of the mass variation close to experimental data was selected, whose solubility and diffusivity were affected by the hygroscopic characteristics of the material. The method can be useful in the industrial fields to quickly characterize the polymer material of the semiconductor package because the fast correspondence is normally required in industry. The weight changes in the aluminum-nonconductive-polymer joint due to moisture absorption were measured. The deformed system was also measured using the Moire Interferometry system and compared with the results of finite element analysis.

External Exposure Due to Natural Radionuclides in Building Materials in Korean Dwellings (건축자재내 포함된 천연방사성핵종에 의한 실내 공간의 방사선량 평가)

  • Cho, Yoon Hae;Kim, Chang Jong;Yun, Ju Yong;Cho, Dae-Hyung;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.181-190
    • /
    • 2012
  • Naturally occurring radioactive materials (NORM) in building materials are main sources of external radiation exposure to the general public. The objective of this study was to assess external radiation dose in Korean dwellings due to NORM in concrete walls. Reference room model for dose assessment was made by analyzing room structure and housing scale of Korean dwellings. In addition, dose assessments were made for varying room sizes. Absorbed doses to air and effective dose rates were calculated using radiation transport code MCNPX. Assuming a reference room of $3{\times}4{\times}2.8m^3$, absorbed dose rates in air were 0.80, 0.97, 0.08 nGy $h^{-1}$ per Bq $kg^{-1}$ for uranium series, thorium series, and $^{40}K$, respectively. Effective dose rates were 0.57, 0.69, 0.058 nSv $h^{-1}$ per Bq $kg^{-1}$, respectively. Radiation dose resulting from concrete of ceiling and floor increased with room area while radiation dose from concrete of walls decreased with room area. Therefore, total radiation doses were almost the same for the varying room area from 5 to $30m^2$. Effective dose in Korean dwellings was calculated based on measurement data of NORM concentration in concrete and occupancy fraction of Korean population by location. Annual effective dose was 0.59 mSv assuming that indoor occupancy fraction was 0.89 and concentrations of uranium series, thorium series and $^{40}K$ were 26, 39, 596 Bq $kg^{-1}$, respectively. Finally, annual effective dose in Korean dwellings can be calculated by the following equation: Effective dose=indoor occupancy fraction${\times}8760\;h\;y^{-1}{\times}(0.57C_U+0.69C_{Th}+0.058C_K)$.

Development of a Multi-zone Combustion Model for the Analysis of CAI Engines (CAI 엔진 해석을 위한 multi-zone 연소 모델의 개발)

  • Lee, Kyeong-Hyeon;Lim, Jae-Man;Kim, Young-Rae;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.74-80
    • /
    • 2008
  • A combustion of CAI engine is purely dominated by fuel chemical reactions. In order to simulate the combustion of CAI engine, it should be considered the effect of fuel components and chemical kinetics. So it needs enormous computational power. To overcome this problem reduced problem of needing massive computational power, chemical kinetic mechanism and multi-zone method is proposed here in this paper. A reduced chemical kinetic mechanism for a gasoline surrogate was used in this study for a CAI combustion. This gasoline surrogate was modeled as a blend of iso-octane, n-heptane, and toluene. For the analysis of CAI combustion, a multi-zone method as combustion model for a CAI engine was developed and incorporated into the computational fluid dynamics code, STAR-CD, for computing efficiency. This coupled multi-zone model can calculate 3 dimensional computational fluid dynamics and multi-zoned chemical reaction simultaneously in one time step. In other words, every computational cell interacts with the adjacent cells during the chemical reaction process. It can enhance the reality of multi-zone model. A greatly time-saving and yet still relatively accurate CAI combustion simulation model based on the above mentioned two efficient methodologies, is thus proposed.

THREE-DIMENSIONAL FLOW PHENOMENA IN A WIRE-WRAPPED 37-PIN FUEL BUNDLE FOR SFR

  • JEONG, JAE-HO;YOO, JIN;LEE, KWI-LIM;HA, KWI-SEOK
    • Nuclear Engineering and Technology
    • /
    • v.47 no.5
    • /
    • pp.523-533
    • /
    • 2015
  • Three-dimensional flow phenomena in a wire-wrapped 37-pin fuel assembly mock-up of a Japanese loop-type sodium-cooled fast reactor, Monju, were investigated with a numerical analysis using a general-purpose commercial computational fluid dynamics code, CFX. Complicated and vortical flow phenomena in the wire-wrapped 37-pin fuel assembly were captured by a Reynolds-averaged Navier-Stokes flow simulation using a shear stress transport turbulence model. The main purpose of the current study is to understand the three-dimensional complex flow phenomena in a wire-wrapped fuel assembly to support the license issue for the core design. Computational fluid dynamics results show good agreement with friction factor correlation models. The secondary flow in the corner and edge subchannels is much stronger than that in an interior subchannel. The axial velocity averaged in the corner and edge subchannels is higher than that averaged in the interior subchannels. Three-dimensional multiscale vortex structures start to be formed by an interaction between secondary flows around each wire-wrapped pin. Behavior of the large-scale vortex structures in the corner and edge subchannels is closely related to the relative position between the hexagonal duct wall and the helically wrapped wire spacer. The small-scale vortex is axially developed in the interior subchannels. Furthermore, a driving force on each wire spacer surface is closely related to the relative position between the hexagonal duct wall and the wire spacer.

Development of Computational Evaluation Method for Fatigue Crack Growth Rate based on Viscoplastic-Damage Model (점소성-손상모델 기반 피로균열 진전속도 전산 평가법 개발)

  • Kim, Seul-Kee;Kim, Jeong-Hyeon;Lee, Chi-Seung;Kim, Myung-Hyun;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • In this paper, computational evaluation method for fatigue crack growth rate(FCGR) based on material viscoplastic-damage model is proposed. Viscoplastic-damage model expressing material constitutive behavior of 7% nickel steel is introduced and is implemented into commercial finite element analysis(FEA) code, ABAQUS, as a user defined material subroutine(UMAT) for application in the FEA environments. Verification of developed UMAT and material parameters of material model are carried out by uniaxial tensile test simulations of 7% nickel steel. Moreover, jump-in-cycles procedure and rearrangement of critical damage are employed and also implemented to the ABAQUS UMAT for fatigue damage analysis. Typical FCGR test results such as relationship between crack length and number of cycles and relationship between da/dN and ${\Delta}K$ could be obtained from FCGR test simulation using developed UMAT and these results are compared with experimental results in order to verify of proposed computational method.

Investigation on the Material and Migration Tests of Gas Impermeable Plastic Vacuum Packaging Materials for Food-Contact Use (식품용 합성수지제 공기차단성 포장재에서의 재질 및 용출시험량 조사)

  • Lee, Jung-Pyo;Lee, Youn-Kyu;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.14 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • Twenty eight gas impermeable plastic films for food-contact application were collected in the domestic market and material and/or migration tests for overall migration, antioxidants, potassium permanganate consumption, heavy metal, and plasticizers were carried out. The average overall migration values for NY/PE or NY/LLDPE, PETP/PE, and PVDC packaging films obtained by using n-heptane as fatty food simulant were 7.6, 6.9 and 14.1 mg/L, respectively. These values were much lower than the limit values of 150 and 30 mg/L for polyethylene and polyvinylidene chloride prescribed in the Korea Food Code. In almost of the packaging materials tested, the antioxidants such as Irganox 1010, Irganox 1076 and Irgafos 168 were found. The migration test result showed that almost of all samples except PVDC film contained Irganox 1076 and Irgafos 168, while the maximum migration value of Irganox 1076 into n-heptane was found in the Ny/PE/LLDPE(15/25/50 ${\mu}m$) sample at the concentration of 216.9 ${\mu}g/g$. From the plastic packaging samples tested, plasticizers such as DEP, DPRP, DBP, DPP, BBP, DCHP, DEHP, DEHA and observed above the detection limit. Consumption amount of potassium permanganate was much lower than the limit value of 10 mg/L. In the material test for heavy metals, cadmium and lead were determined at the concentrations far below the limit value of 100 mg/kg. The migration test for cadmium and lead showed a lower value than the detection limit. Therefore, it can be concluded that the safety status of the plastic films tested met the requirement of limit values as prescribed for the material and migration tests of food packaging utensils, containers and packages of the Korea Food Code.

  • PDF

Capacity Comparison of Two Uplink OFDMA Systems Considering Synchronization Error among Multiple Users and Nonlinear Distortion of Amplifiers (사용자간 동기오차와 증폭기의 비선형 왜곡을 동시에 고려한 두 상향링크 OFDMA 기법의 채널용량 비교 분석)

  • Lee, Jin-Hui;Kim, Bong-Seok;Choi, Kwonhue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.5
    • /
    • pp.258-270
    • /
    • 2014
  • In this paper, we investigate channel capacity of two kinds of uplink OFDMA (Orthogonal Frequency Division Multiple Access) schemes, i.e. ZCZ (Zero Correlation Zone) code time-spread OFDMA and sparse SC-FDMA (Single Carrier Frequency Division Mmultiple Access) robust to access timing offset (TO) among multiple users. In order to reflect the practical condition, we consider not only access TO among multiple users but also peak to average power ratio (PAPR) which is one of hot issues of uplink OFDMA. In the case with access TO among multiple users, the amplified signal of users by power control might affect a severe interference to signals of other users. Meanwhile, amplified signal by considering distance between user and base station might be distorted due to the limit of amplifier and thus the performance might degrade. In order to achieve the maximum channel capacity, we investigate the combinations of transmit power so called ASF (adaptive scaling factor) by numerical simulations. We check that the channel capacity of the case with ASF increases compared to the case with considering only distance i.e. ASF=1. From the simulation results, In the case of high signal to noise ratio (SNR), ZCZ code time-spread OFDMA achieves higher channel capacity compared to sparse block SC-FDMA. On the other hand, in the case of low SNR, the sparse block SC-FDMA achieves better performance compared to ZCZ time-spread OFDMA.