• Title/Summary/Keyword: (MRI)

Search Result 4,574, Processing Time 0.041 seconds

Comparison of SUV for PET/MRI and PET/CT (인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화)

  • Kim, Jae Il;Jeon, Jae Hwan;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Is the Utilization of MID Services affected by the Implementation of Insurance Coverage?: Based on Claim Data of a General Hospital (MRI 보험급여 적용이 진료이용량에 미치는 영향 : 한 종합병원의 청구자료를 중심으로)

  • Kim, Seon-Hee;Kim, Chun-Bae;Cho, Kyung-Hee;Kang, Im-Ok
    • Health Policy and Management
    • /
    • v.18 no.2
    • /
    • pp.1-18
    • /
    • 2008
  • As medical insurance had been implemented for Magnetic Resonance Imaging (MRI) from January 1, 2005, this study investigated whether there had been any change in the amount of the medical care utilization of patients who undertook MRI before and after the insurance coverage, and was to examine factors affecting the amount of medical care utilization of MRI. Data were collected from patients who undertook MRI before and after the insurance coverage for a year at a general hospital in Kyeanggi-do. $X^2$ and t-test were used for the analysis of their general characteristics, the number of MRI, and its medical costs before and after the insurance coverage, and hierarchical multiple regression analysis for the factors affecting the amount of the medical care utilization of MRI. The results of this study were as follows. First, the number of MRI after the insurance coverage was significantly decreased. Second, there was no significant difference in the total medical costs of MRI after the insurance coverage, but a significant difference was found in patient's share of medical costs. Third, six variables were found to be affecting the amount of the medical care utilization of MRI, and the variables showed to lead the number of MRI decrease after the insurance coverage. These six factors explained 21.4% of the total number of MRI. As MRI had been covered by insurance, the use of MRI and patient's share of the costs were deceased, but the total medical costs were not affected. Reasons for that could be found in that MRI insurance, different from the case of CT insurance coverage, was allowed not to cover some items and the kinds of diseases subjected to the insurance coverage were extremely limited, lowering insurance prescription rate. In addition to that, the average medical cost of MRI was not changed after the insurance coverage. Therefore, as future measures for the MRI insurance, coverage, it should be considered to allow insurance coverage to no coverage items and to expand the scope of benefit coverage, or to lower patient's share of the costs. Furthermore, researches should be done to explore how recipients will act and how suppliers will react if the coverage is expanded, including expanding the scope of coverage and reducing patient's share of the costs, as well as to conduct research on its economic analysis according to case mix.

Comparative Analysis of Understanding and Satisfaction of MRI Patients after Leaflet Training (리플릿 교육 후 MRI 환자의 이해도 및 만족도 비교분석)

  • Park, Chang-Hee;Han, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.123-129
    • /
    • 2022
  • Recently, the penetration rate of Magnetic Resonance Imaging (MRI) is higher than the average among OECD member countries, and the number of MRI scans is increasing. However, MRI scans take longer than other medical devices, and patient movement must be minimized. Therefore, patient discomfort always follows. When the examination is performed in the discomfort of the patient, it is difficult to perform an accurate examination, and it is difficult to obtain an image of diagnostic value. So, in the past, the patient was asked to read the written guide for the risk and cooperation of MRI, but it was composed of technical terms and difficult-to-understand sentences, so it was difficult to understand. The purpose of this study is to supplement these problems and increase the understanding of MRI scans to help acquire images of diagnostic value. In addition, it is intended to evaluate the excellence of leaflet education by evaluating the understanding and satisfaction of patients. As shown in the results of this study, understanding and satisfaction scores were higher after education than before leaflet education, and it was found that there was a difference in understanding according to academic background. However, there was no difference in the number of MRI scans. That is, there was no difference in the number of inspections due to leaflet education. In the future, leaflet education will be widely used for MRI examination, and it is necessary to study the qualitative evaluation of images after leaflet education in the future.

Consideration on Methods to Suppress Metal Artifacts Caused by Spinal Fusion during Spine MRI Study (척추 MRI 검사 시 척추 유합술로 인한 금속 인공물 억제 방법에 대한 고찰)

  • Se-Jong Yoo;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1123-1131
    • /
    • 2023
  • This study aimed to present a method to effectively suppress metal artifacts caused by spinal fusion surgery during spinal MRI study. For this purpose, a phantom made of spinal surgery screws was created to reproduce the metal artifact. Then, images were acquired with 1.5T and 3.0T MRI to evaluate changes in metal artifacts according to magnetic field strength. In addition, metal artifacts were evaluated by increasing the receive bandwidth to 200, 400 and 800 Hz/PX. As a result, metal artifacts occurring in images obtained from the 1.5T MRI decreased by approximately 52.2% compared to images obtained from the 3.0T MRI, showing a significant difference (p<0.05). In particular, the signal loss and signal pile up areas were reduced by approximately 52.81% and 42.71%, respectively, showing a significant effect in suppressing metal artifacts. On the other hand, when images were acquired while increasing the receive bandwidth from 200 to 800 Hz/PX, there was no significant effect, with a decrease of up to 8.93% for the 1.5T MRI and up to 10.98% for the 3.0T MRI (p>0.05). As a result of this study, increasing the receive bandwidth reduced signal loss and reduced some metal artifacts, but did not have a significant effect because it did not suppress signal pile up. However, when the magnetic field strength was reduced from 3.0T to 1.5T, signal loss and signal pile up were greatly reduced, effectively improving the metal artifact. Therefore, in order to suppress metal artifacts caused by spinal fusion surgery, study using a low magnetic field MRI can be said to be the most effective method.

Retrospective Review of Magnetic Resonance Imaging of the Lumbosacral Spine: Are We Overinvestigating?

  • Khanduja, Suchit;Loomba, Vivek;Salama-Hannah, Joseph;Upadhyay, Aman;Khanduja, Neha;Chauhan, Gaurav
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.383-387
    • /
    • 2018
  • Objective: Lower back pain (LBP) is a worldwide health problem, and magnetic resonance imaging (MRI) is a common modality used to aid in its diagnosis. Although specific guidelines for assessing the necessity of MRI usage exist, the use of MRI as the initial imaging method for LBP seems to be more common than necessary in general practice. Methods: We conducted a retrospective chart review of 313 patients who had undergone MRI of the lumbosacral spine during 2014-2015. We recorded and compared various factors, including age, sex, body mass index, current smoking status, race, symptoms, MRI findings, and progression to surgery within the next year. All rates were compared according to whether the MRI results showed radiographically significant findings (MRI-positive) or not (MRI-negative) using the chi-square or Fisher exact tests (if the expected cell count was <5). All analyses were performed using SAS version 9.4. Results: There were no statistically significant differences in the rates of each symptom between the MRI-positive and MRI-negative groups, which accounted for 58.5% (183 of 313) and 41.5% (130 of 313) of the MRIs, respectively. The difference in the rate of surgery in the next year (18% among MRI-positive patients and 8.5% among MRI-negative patients) was found to be statistically significant (p<0.05). Conclusion: Based on our findings, 41.5% of patients underwent lumbar MRI unnecessarily and 81% of patients with positive MRIs did not have surgery within the next year. Further physician training is needed to avoid unnecessary investigations and expenditures.

An Analysis on the Effect of the Increase in the Fee of Magnetic Resonance Imaging Deciphering of the External Hospital: Focusing on the Brain Magnetic Resonance Imaging (MRI 외부병원 판독 수가 인상의 효과 분석: 뇌 관련 자기공명영상을 중심으로)

  • Kim, Logyoung;Sakong, Jin;Jo, Minho;Wee, Seah;Lee, Jinyong;Kim, Yongkyu
    • Health Policy and Management
    • /
    • v.31 no.3
    • /
    • pp.261-271
    • /
    • 2021
  • Background: In 2018, the government increased the fee for the magnetic resonance imaging (MRI) image deciphering services of the external hospital to discourage the redundant MRI scan and to induce appropriate use of the MRI services. It is important to evaluate the effect of the policy to provide the basis for establishing other MRI-related policies. Methods: The healthcare data of the patients who had brain MRI scans were organized by episode and analyzed using the panel study in order to find out the effect of the MRI-related policy on the substitution effect and the medical expenses. Results: As a result of the increase in the fee of deciphering the MRI image, there has been an uplift in deciphering the MRI scan of the external hospital. It implies that more hospitals chose to use the MRI scan taken by other clinics or hospitals, rather than the MRI scan taken at their own facilities. Conclusion: The research results imply that a policy that facilitates the exchange of the medical image data between the hospitals is needed in order to establish an efficient management system of the healthcare resources. Such improvement is expected to reduce the social cost and contribute to the stability in the finance of national health insurance.

Usefulness Evaluation 'Ankle Stress View Compared with MRI scan' of Subacute Ankle Sprain (아급성기 발목염좌에 대한 Stress View와 MRI검사 대비 유용성 평가)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.201-205
    • /
    • 2011
  • Subacute Ankle Sprain patients, 3 tests have been acknowledge for diagnostic precision and thus most commonly used to test their soft tissues, muscles, and ligaments: ankle stress-valgus test, anterior-draw test, and MRI scan. Although not much different from the rest two in its diagnostic value, MRI costs patients some money and time. Also, we have reached the conclusion through an experiment with a group of patients in a certain hospital that the rest two methods is as efficient and useful as MRI in diagnosing ankle joint patients.

Functional Magnetic Resonance Imaging with Arterial Spin Labeling: Techniques and Potential Clinical and Research Applications

  • Kim, Ju Ho;Choi, Dae Seob;Park, Sung Eun;Choi, Ho Cheol;Kim, Seong Hu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.91-96
    • /
    • 2017
  • Purpose: To describe technical methods for functional magnetic resonance imaging (fMRI) study with arterial spin labeling (ASL) compared to blood oxygenation level-dependent (BOLD) technique and discuss the potential of ASL for research and clinical practice. Materials and Methods: Task-based (n = 1) and resting-state fMRI (rs-fMRI) (n = 20) were performed using ASL and BOLD techniques. Results of both techniques were compared. Results: For task-based fMRI with finger-tapping, the primary motor cortex of the contralateral frontal lobe and the ipsilateral cerebellum were activated by both BOLD and ASL fMRI. For rs-fMRI of sensorimotor network, functional connectivity showed similar results between BOLD and ASL. Conclusion: ASL technique has potential application in clinical and research fields because all brain perfusion imaging, CBF measurement, and rs-fMRI study can be performed in a single acquisition.

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images (MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법)

  • Kim, Hyoung-Jin;Seo, Kwang-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.948-958
    • /
    • 2010
  • Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.

Magnetic Resonance Imaging in Thorax (흉부의 자기공명영상)

  • Choi, Byoung Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.571-584
    • /
    • 2004
  • Magnetic Resonance Imaging (MRI) is one of the most advanced imaging techniques in clinical and research medicine. However, clinical application of MRI to the lung or thorax has been limited due to various drawbacks. Low signal intensity of the lung and cardiac and respiratory movements are the most serious problems with MRI in thorax. Nevertheless, MRI is superior to CT in some selected patients with thoracic diseases. The role of clinical MRI in thoracic disease has been widened with improvement of MR equipments and development of new pulse sequences. Otherwise, functional assessment of lung by MRI has been studied for the last decade. These include perfusion MRI with or without contrast enhancement and ventilation MRI with oxygen-enhancement or hyperpolarized noble gas, $^3He$ and $^{129}Xe$.