• 제목/요약/키워드: (L2) language model

검색결과 31건 처리시간 0.023초

다분야통합최적설계를 지원하는 분산환경 기반의 설계 프레임워크 개발 (Development of a Distributed Computing Framework far Implementing Multidisciplinary Design Optimization)

  • 주민식;이세정;최동훈
    • 한국CDE학회논문집
    • /
    • 제10권2호
    • /
    • pp.143-150
    • /
    • 2005
  • A design framework to employ the multidisciplinary design optimization technologies on a computer system has been developed and is named as the Extensible Multidisciplinary Design Integration and Optimization System (EMDIOS). The framework can not only effectively solve complex system design problems but also conveniently handle MDO problems. Since the EMDIOS exploits both state-of-the-art of computing capabilities and sophisticated optimization techniques, it can overcome many scalability and complexity problems. It can make users who are not even familiar with the optimization technology use EMDIOS easily to solve their design problems. The client of EMDIOS provides a front end for engineers to communicate the EMDIOS engine and the server controls and manages various resources luck as scheduler, analysis codes, and user interfaces. EMDIOS client supports data monitoring, design problem definition, request for analyses and other user tasks. Three main components of the EMDIOS are the Engineering Design Object Model which is a basic idea to construct EMDIOS, EMDIOS Language (EMDIO-L) which is a script language representing design problems, and visual modeling tools which can help engineers define design problems using graphical user interface. Several example problems are solved and EMDIOS has shown various capabilities such as ease of use, process integration, and optimization monitoring.

퍼지와 인공 신경망을 이용한 침입탐지시스템의 탐지 성능 비교 연구 (Comparison of Detection Performance of Intrusion Detection System Using Fuzzy and Artificial Neural Network)

  • 양은목;이학재;서창호
    • 디지털융복합연구
    • /
    • 제15권6호
    • /
    • pp.391-398
    • /
    • 2017
  • 본 논문에서는 "퍼지 컨트롤 언어를 이용한 공격 특징 선택기반 네트워크 침입탐지 시스템"[1]과 "RNN을 이용한 공격 분류를 위한 지능형 침입탐지 시스템 모델"[2]의 성능을 비교 하였다. 이 논문에서는 KDD CUP 99 데이터 셋[3]을 이용하여 두 기법의 침입 탐지 성능을 비교하였다. KDD CUP 99 데이터 셋에는 훈련을 위한 데이터 셋과 훈련을 통해 기존의 침입을 탐지 할 수 있는 테스트 데이터 셋이 있다. 또한 훈련 데이터 및 테스트 데이터에 존재 하지 않는 침입의 유형을 탐지할 수 있는가를 테스트 할 수 있는 데이터도 존재한다. 훈련 및 테스트 데이터에서 좋은 침입탐지 성능을 보이는 두 개의 논문을 비교하였다. 비교한 결과 존재하는 침입을 탐지 하는 성능은 우수하지만 기존에 존재하지 않는 침입을 탐지 하는 성능은 부족한 부분이 있다. 공격 유형 중 DoS, Probe, R2L는 퍼지를 이용하는 것이 탐지율이 높았고, U2L은 RNN을 이용하는 것이 탐지율이 높았다.

A Validity Study on the Vocabulary Grade Levels Test for Korean Elementary Students

  • Shin, Yousun
    • 영어어문교육
    • /
    • 제18권2호
    • /
    • pp.125-147
    • /
    • 2012
  • The primary goal of the study was to provide some preliminary validity evidence for the Vocabulary Grade Levels Test (Busan Metropolitan City Office of Education, 2009), which is designed to measure the receptive vocabulary knowledge of learners in L2. For the purpose of the current study, 327 participants at the elementary school participated in the study and were asked to take two different vocabulary tests. Namely, a Vocabulary Size Test (Nation, 2001) and a Vocabulary Grade Levels Test. The data were analyzed using correlation in order to discover the relationship between these two types of tests. Following this, the Rasch analysis was conducted to examine the reliability and validity of the measurement in question. The data analysis showed that both grade separation reliability and item separation reliability were high, indicating that the Vocabulary Grade Levels Test well discriminates learners with a wide range of proficiency levels. The findings of the study are discussed, along with further improvements in order to ascertain the validity of this particular vocabulary test.

  • PDF

모음 유형과 표준문단의 문장 위치가 음성장애 환자의 청지각적 및 켑스트럼 및 스펙트럼 분석에 미치는 효과 (Effects of vowel types and sentence positions in standard passage on auditory and cepstral and spectral measures in patients with voice disorders)

  • 최미현;최성희
    • 말소리와 음성과학
    • /
    • 제15권4호
    • /
    • pp.81-90
    • /
    • 2023
  • 청지각적 평가 및 음향학적 분석은 음성평가를 위해 임상 현장에서 일반적으로 사용해오고 있다. 본 연구는 음성장애 환자의 청지각적 및 음향학적 측정 시 말 과제 효과를 조사하고자 한다. 음성장애로 진단받은 총 22명의 환자로부터 모음연장발성(/a/, /e/, /i/, /o/, /u/, /ɯ/, /ʌ/)과 연속구어('가을'표준문단의 9개 하위문장)를 녹음하였다. 음성장애 평가 및 치료 경험이 있는 2명의 음성언어치료사가 맹검 및 무작위 음성 샘플을 사용하여 GRBAS('G', 'R', 'B', 'A', 'S')척도 및 CAPE-V('OS', 'R', 'B', 'S', 'P', 'L')를 사용하여 청지각적 평가를 실시하였다. 또한, ADSV(analysis of dysphonia in speech and voice model)를 이용하여 켑스트럼 및 스펙트럼 측정치를 구하였다. 모음 유형에 따라 GRBAS 척도에서 'B'를 제외하고 청지각적 평가에 영향을 미치지 않았으나, CAPE-V에서는 'OS', 'R', 'B'에 영향을 미쳤다(p<.05). CPP 및 L/H ratio 는 모음 유형과 문장 위치의 영향을 받았다. 표준문단의 CPP값은 모든 모음에서 'G', 하위 9문장과 유의미한 부적 상관 관계가 나타났고, 특히, /e/모음(r=-.739)에서 가장 높은 상관관계를 보였다. 두 번째 문장의 CPP는 모든 모음과 높은 상관관계를 보였다. CAPE-V는 말 자극에 따라 GRBAS보다 청지각적 평가에 더 많은 영향을 받을 수 있으며, 'B' 척도, CPP, L/H ratio는 모음 유형과 자음을 포함한 문장 위치에 따라 영향을 받았다. 따라서, 음성 장애 환자의 음성 평가에서 모음을 사용할 때는 /a/뿐만 아니라 ' 기식성'음질과 음향적으로 상관성이 높은 /i/모음을 함께 사용하는 것이 유용할 수 있다. 또한 /e/모음은 한국 표준문단 '가을' 및 하위 문장들과 음향적으로 상관성이 높았으므로 문단 대신 사용할 수 있을 것이다. 또한, 음성장애 신호들이 대부분 비주기적이라는 점을 감안할 때, CPP와 함께 표준문단 중 가장 음향적으로 상관성이 높은 두 번째 문장을 사용할 수 있을 것이다. 이러한 결과는 말과제가 청지각적 평가 및 음향학적 측정에 미치는 영향에 대한 임상적 증거를 제공하며, 이는 음성장애 환자의 음성 평가에 대한 가이드라인을 제공하는 데 도움을 줄 수 있을 것이다.

Web GIS 구축시 UML을 이용한 모델링에 관한 연구 - 충북대학교를 중심으로 - (The Study of Modeling in Web GIS-System using UML - The special reference of Chungbuk National University -)

  • 손영기;신영철
    • 한국지리정보학회지
    • /
    • 제4권2호
    • /
    • pp.46-60
    • /
    • 2001
  • 본 논문은 객체분산 시스템인 Web GIS시스템를 구축하고 UML을 이용하여 가시화, 시스템 구조와 행동을 명세화하였다. GIS의 UML 개념모델의 연구는 Shapefile를 모델개념으로 클래스도와 스테레오타입으로 추상화하였다. 통합된 모델인 UML을 사용하여 아키텍처와 역공 학을 중심으로 모델링하였다. 본 연구는 시스템을 구축하고 기본 형태를 제공하며, 시스템 분석/설계의 문서화를 통하여 S/W시스템의 기본 요소를 객체 또는 클래스로 파악하여 문제 영역과 해결 영역을 모델링함으로써 요구사항 변화시 적응력을 높이고 대규모 시스템에서 유지 보수들을 포함한 관리를 보다 능동적으로 관리할 수 있음을 제시할 수 있었다.

  • PDF

가습기 살균제 성분(PHMG, PGH, CMIT/MIT)의 사람 피부세포 독성 및 제브라피쉬 뇌신경 독성 비교 연구 (Comparison study of dermal cell toxicity and zebrafish brain toxicity by humidifier sterilizer chemicals (PHMG, PGH, CMIT/MIT))

  • 조경현;김재룡
    • 환경생물
    • /
    • 제38권2호
    • /
    • pp.271-277
    • /
    • 2020
  • 가습기 살균제 성분(PHMG, PGH, CMIT/MIT)의 노출에 의한 다양한 장기에 대한 독성들에 대해서 피해사례는 계속 증가하고 있으나, 세포모델과 동물모델에서의 연구와 보고는 아직 부족한 실정이다. 심혈관 독성, 간 독성, 배아 독성에 대해서는 최근 알려져 있으나 뇌신경 독성과 피부 독성에 대해서는 상대적으로 적게 알려져 있다. 본 연구에서는 이들 세 가지 성분들의 피부 독성과 뇌신경 독성을 사람 피부섬유세포와 제브라피쉬 동물모델을 대상으로 각각 평가하였다. 사람피부섬유세포에 세 가지의 성분들을 0, 2, 4, 6, 8, 16 mg L-1 (최종농도)로 처리하였을 때, 세포 생존율은 PHMG가 33%로 가장 낮았고, PGH가 49%, CMIT/MIT가 40%의 생존율을 보였다. 세포배양액 내의 산화물을 정량해본 결과, PHMG 처리된 세포가 28 nmol MDA로 가장 높았고, PGH가 13 nmol MDA, CMIT가 21 nmol MDA를 보였다. 제브라피쉬 사육수조에 PHMG, PGH, CMIT를 40 mg L-1의 최종농도가 되도록 희석한 후, 제브라피쉬를 30분간 노출시킨 후 중뇌의 광시개영역(optic tectum)을 횡면 미세절단하여 산화물의 생성정도를 비교해본 결과, CMIT/MIT를 처리한 그룹에서 대조군 대비 17배 많은 산화물의 생성이 있었고, PGH를 처리한 그룹에서는 15배, PHMG를 처리한 그룹에서는 11배 많은 산화물이 관찰되어 심각한 뇌신경계 독성을 보여주었다. 결론적으로 세 가지 종류의 가습기 살균제 성분들에서 모두 심각한 피부세포 독성과 뇌신경계 독성이 나타났는데, 피부 독성은 특히 PHMG가, 뇌신경계 독성은 특히 CMIT/MIT가 가장 심각하였다. 이들 결과들은 가습기 살균제에 노출된 어린이들이 뇌신경계 독성을 통하여 언어장애, 운동장애, 발달장애 등을 겪게 될 수도 있음을 실험적으로 제시한다.

포인터 네트워크를 이용한 한국어 대명사 상호참조해결 (Coreference Resolution for Korean Pronouns using Pointer Networks)

  • 박천음;이창기
    • 정보과학회 논문지
    • /
    • 제44권5호
    • /
    • pp.496-502
    • /
    • 2017
  • 포인터 네트워크(Pointer Networks)는 Recurrent Neural Network (RNN)를 기반으로 어텐션 메커니즘(Attention mechanism)을 이용하여 입력 시퀀스에 대응되는 위치들의 리스트를 출력하는 딥 러닝 모델이다. 대명사 상호참조해결은 문서 내에 등장하는 대명사와 이에 대응되는 선행사를 찾아 하나의 엔티티로 정의하는 자연어처리 문제이다. 본 논문에서는 포인터 네트워크를 이용하여 대명사와 선행사의 참조관계를 밝히는 대명사 상호참조해결 방법과 포인터 네트워크의 입력 연결순서(chaining order) 여섯가지를 제안한다. 실험 결과, 본 논문에서 제안한 방법 중 연결순서 coref2 가 MUC F1 81.40%로 가장 좋은 성능을 보였다. 이는 기존 한국어 대명사 상호참조해결의 규칙 기반(50.40%)보다 31.00%p, 통계 기반(62.12%) 보다 19.28%p 우수한 성능임을 나타낸다.

Machinability investigation and sustainability assessment in FDHT with coated ceramic tool

  • Panda, Asutosh;Das, Sudhansu Ranjan;Dhupal, Debabrata
    • Steel and Composite Structures
    • /
    • 제34권5호
    • /
    • pp.681-698
    • /
    • 2020
  • The paper addresses contribution to the modeling and optimization of major machinability parameters (cutting force, surface roughness, and tool wear) in finish dry hard turning (FDHT) for machinability evaluation of hardened AISI grade die steel D3 with PVD-TiN coated (Al2O3-TiCN) mixed ceramic tool insert. The turning trials are performed based on Taguchi's L18 orthogonal array design of experiments for the development of regression model as well as adequate model prediction by considering tool approach angle, nose radius, cutting speed, feed rate, and depth of cut as major machining parameters. The models or correlations are developed by employing multiple regression analysis (MRA). In addition, statistical technique (response surface methodology) followed by computational approaches (genetic algorithm and particle swarm optimization) have been employed for multiple response optimization. Thereafter, the effectiveness of proposed three (RSM, GA, PSO) optimization techniques are evaluated by confirmation test and subsequently the best optimization results have been used for estimation of energy consumption which includes savings of carbon footprint towards green machining and for tool life estimation followed by cost analysis to justify the economic feasibility of PVD-TiN coated Al2O3+TiCN mixed ceramic tool in FDHT operation. Finally, estimation of energy savings, economic analysis, and sustainability assessment are performed by employing carbon footprint analysis, Gilbert approach, and Pugh matrix, respectively. Novelty aspects, the present work: (i) contributes to practical industrial application of finish hard turning for the shaft and die makers to select the optimum cutting conditions in a range of hardness of 45-60 HRC, (ii) demonstrates the replacement of expensive, time-consuming conventional cylindrical grinding process and proposes the alternative of costlier CBN tool by utilizing ceramic tool in hard turning processes considering technological, economical and ecological aspects, which are helpful and efficient from industrial point of view, (iii) provides environment friendliness, cleaner production for machining of hardened steels, (iv) helps to improve the desirable machinability characteristics, and (v) serves as a knowledge for the development of a common language for sustainable manufacturing in both research field and industrial practice.

다중 Application을 위한 Web Services 상호 운용성에 관한 연구 (Study of Web Services Interoperabiliy for Multiple Applications)

  • 유윤식;송종철;최일선;임산송;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.217-220
    • /
    • 2004
  • 웹의 이용이 급속하게 증가함에 따라, 웹 기반의 어플리케이션 대 어플리케이션간의 상호작용을 체계적으로 지원하는 적절한 모형과 새로운 분산 플랫폼을 기존 환경들과 효율적으로 통합할 수 있는 방안에 대한 요구가 발생하였으며 이에 대한 해결책으로 웹 서비스가 등장하였다. 현재 많은 소프트웨어와 하드웨어 업체들이 웹 서비스를 시장에 도입하려 하는 적극적인 시도를 보이고 있으며 어플리케이션들을 다양한 웹 서비스 제공자들로부터의 컴포넌트를 조합하여 구축하려 하고 있다. 하지만 웹 서비스를 완벽히 이행하기 위해서는 반드시 상호 운용되어야 하며 다른 업체들로부터의 서비스뿐만 아니라 플랫폼, 어플리케이션과 프로그래밍 언어에 종속되지 않도록 하는 일련의 표준화 작업이 필요하다. 이에 웹 서비스 상호 운용성 표준화 기구인 WS-I(Web Services Interoperability Organization)에서는 XML, UDDI, WSDL 그리고 SOAP을 기본으로 웹 서비스 상호운용을 위한 표준인 기본 프로파일(Basic Profile 1.0)을 제정하였으며 실제 적용하기 위한 웹 서비스 사용자 시나리오의 프로파일을 개발하고 있다. 이에 본 논문에서는 이질적인 두 어플리케이션간의 웹 서비스 상호 운용의 적합성을 검증하기 위하여 도서 정보 검색 웹 서비스를 J2SE 플랫폼의 웹 서비스 글라이언트와 .NET 플랫폼의 웹 서비스 서버를 기반으로 각각 설계 및 구현하고 서로 서비스가 이루어지도록 하여 이질적인 두 플랫폼 사이에서 상호 운용이 가능하다는 것을 보이며 두 어플리케이션 간의 전송 서비스를 WS-I 기본 프로파일을 적용하여 테스트 및 검증하였다.조건으로 혼합한 실험구를 설정하였다. 실험구는 각각 NWT+35‰, CWT+35‰, NWT+15‰, NWT+15‰, NWT+35‰+Anes., CWT+35‰+Anes., NWT+15‰+Anes. 및 CWT+15‰+Anes.의 8개 실험구를 2반복으로 설정하여 경북울진∼부산까지 약 400 km (6시간)를 차량수송하였다. 수송용기는 스티로폼상자(66×42×20 cnn)로서, 여기에 해수 3 L와 액화산소를 넣은 비닐봉지에 넙치 8마리씩 수용하여 수송하였다. 혈액의 성상 및 분석항목은 수송전ㆍ후에 채혈하여 비교하였다. 수송전 hematocrit는 22.2±3.8%에서 수송후 NWT+35‰에서 15.3+3.9%, CWT+35‰은 16.7±3.0%, NWT+15‰구에서는 19.2±1.8%로 낮아졌으며, CWT+15‰구는 20.9±3.6%로 수송전과 차이가 없었다. 한편 NWT+15‰+Anes.구는 17.8±0.9%, CWT+15‰+Anes.구는 14.5±1.5%로 낮아졌다. Cortisol은 수송전 2.4±0.1 ng/ml로부터 CWT+35‰구는 16.7±12.8 ng/ml, NWT+35‰구는 47.9+19.8 ng/ml, NWT+15‰구는 43.5±13.9 ng/ml, CWT+15‰구는 26.1±8.3 ng/ml, NWT+15‰+Anes.구는 61.7±3.3 ng/ml, CWT+15‰+Anes.구는 86.1±19.0 ng/ml로 높아졌다. Glucose는 수송전 74.2±32.6 mg/dl로부터 NWT+35‰구는 197.9±27.5 mg/dl, CWT+35‰구도 272.1±29.9 mg/dl로 유의하게 높아졌다. Na/sup +/의 수송전 농도는 16

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF