• Title/Summary/Keyword: 'room'

Search Result 15,343, Processing Time 0.048 seconds

Structural, physical and electrical properties of SiO2 thin films formed by atmospheric-pressure plasma technology

  • Kyoung-Bo Kim;Moojin Kim
    • Journal of Ceramic Processing Research
    • /
    • v.23 no.4
    • /
    • pp.535-540
    • /
    • 2022
  • Atmospheric pressure plasma (APP) systems operate at atmospheric pressure and low temperatures, eliminating the need forvacuum systems such as vacuum chambers and pumps. In this paper, we studied that silicon dioxide thin films were formedat room temperature (25 oC) and 400 oC by APP processes on silicon wafers. A mixture of hexamethyldisilazane, oxygen,helium, and argon was supplied to the plasma apparatus to form the SiO2 layer. It was observed that a heat insulating layerhaving a thickness of about 22 nm at 25 oC and about 75 nm at 400 oC was formed. Although the surface was clean in samplestreated at 400 oC, small grains were observed in samples processed at room temperature. However, no void or defect in allsamples is observed inside the thin film from the surface. The physical property of the SiO2 thin film carried out by measuringrefractive index and density. The experimental refractive index of silicon dioxide grown by applying heat can be fitted to theSellmeier equation. Also, the film density of the sample at 400 oC using a XRR was observed to be 2.25 g/cm3, similar to thatof the glass, but that of the sample treated at room temp. was very low at 1.68 g/cm3. We also investigated the voltagedependentcurrent change in the oxide material. The SiO2 layer coated at room temperature showed a breakdown electricalfield of 2.5 MV/cm, while oxides deposited at 400 oC showed a characteristic of 9.9 MV/cm.

A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department (핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰)

  • Yoo, Jae-Sook;Jang, Jeong-Chan;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • Purpose: Those who access to the nuclear medicine department are classified as radiation workers, temporarily access group, and occasional access group as defined by the atomic energy law. The radiation workers and temporarily access people wear a personal radiation dosimeter for checking their own radiation absorbed dose periodically. However, because of the sanitation workers, classified as temporarily access group, who are working in the nuclear medicine department are moved in a cycle with other departments and their works are changeful, it is hard to control their radiation absorbed dose. Thus, this study is going to examine the state of the sanitation worker's radiation absorbed dose, and then make sure whether they are classified as temporarily access group or not. Materials and methods: In the first instance, the first sanitation worker who works in vitro laboratory and PET room and the second sanitation worker who works in gamma camera rooms (invivo room) wore radiation dosimeter-OSL(Optically Stimulated Luminescence)- to measure their own radiation absorbed dose during work time from May to June 2011. Secondly, this study was taken place 5 places in gamma camera rooms, 2 places in PET bed room, operating room, waiting room and cyclotron room in PET and 4 places in vitro laboratory. And then to measure the radiation space dose rate, it is measured 10 times each of places as sanitation worker's work flow by using radiation survey meter. Results: The radiation absorbed dose on OSL of the first c who works in vitro laboratory and PET room and the second one who works in gamma camera rooms are 0.04, 0.02 mSv per month respectively. That means the estimated annual radiation absorbed doses are less than 1mSv as 0.48, 0.24 mSv/yr respectively. The radiation space dose rates as sanitation worker's work flow using survey meter are 0.0037, 0.0019 mSv/day, so the estimated annual radiation absorbed dose are 0.93, 0.47 mSv/yr respectively. The weighted exposure dose of first sanitation worker of each places are 1.62% in cyclotron room, 3.88% in waiting room, 2.39% in operating room, 81.01% in bed room of PET and 11.01% in vitro laboratory. The weighted exposure dose of second sanitation worker of each places are 45.22% in radiopharmaceutical laboratory, gamma 30.64% in camera rooms, 15.65% in waiting room, 8.49% in reading room. Conclusion: The annual radiation absorbed doses on OSL of both sanitation workers are less than 1 mSv per year and the annual radiation absorbed doses by using survey meter are less than 1mSv either, but close up to 1 mSv. Thus, to clarify whether the sanitation workers are temporarily access group or not, and to be lessen their s radiation absorbed dose, they should be educated about management of radiation and modified their work flow or work time appropriately, their radiation absorbed dose would be lessen certainly.

  • PDF

Properties of Components for the Dapogye of Hipped and Gable Roof Wooden Buildings (합각지붕 사찰 주불전의 규모에 따른 기둥 및 처마부 관계분석 연구)

  • Go, Jung-Ju;Lee, Jeong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3192-3202
    • /
    • 2014
  • This study has its purposes on analyzing specific features of the elements according to scales of 32 main buddhist sancta among wooden temples with gable roof that are nationally designated as cultural assets, and analyzing influences and proportional relations between main and submaterials, so that it could be basic and objective data for restore and repair cultural assets in the future. Results of the study are following. First of all, the average plane proportion of doritong (facade) and yangtong (side) in 3-room building is about 1.31:1, while it is 1.70:1 in 5-room building. Secondly, as a result of analyzing the locational proportion and thickness of pillars at each location, floor room turned out to have wider space between pillars than that of edge room or side room in both cases of 3 and 5-room buildings. In the mean time, for the average thickness of the pillars in 3-room building, it was 491mm for corner pillars, 433mm for general pillars in cases of 3-room building, while it was 595 and 511mm respectively in cases of 5-room building. The reason why corner pillars are 60~80mm thicker than general ones in average, is determined to considered structural stability and optical illusion. For the third, as a result of analyzing the influences on pillar thickness, eaves projection and eaves height according to the scale(dimension) of buildings, 3-room buildings have outstanding correlation as its scale(dimension) goes bigger, while 5-room ones are not very much influenced by its scale(dimension). For the fourth, as a result of the relation between pillars and eaves, both of 3 and 5-room buildings have longer-projected and higher eaves as their pillars go taller; especially height of eaves turns out to have very close relation between length of pillars. In addition to that, both of 3 and 5-room buildings have much projected eaves as the eaves go higher.

A Study on the mitigation method of explosion and fire accidents in the Boiler room (보일러실 화재.폭발사고 경감방안에 관한 연구)

  • Son, Eun-Soo;Baek, Myoung-Gi;Song, Jae-Su;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.405-409
    • /
    • 2007
  • This paper focused on the way of prevention of disaster in the accident of explosion when the fire broke out in the boiler room where installed the basement of the building, and showed the effective ways for sustaining people and property safely in the view of problems and improvement of the law and safety awareness of people.

  • PDF

A Study on the Room Acoustics in Churches (교회 건축물의 실내음향 특성에 관한 연구)

  • 주진수
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.681-686
    • /
    • 1999
  • In a church, speech intelligibility is very important together with the reverberance for musical activities. In order to obtain the primary data of a acoustical design for churches records were refereed and churches were measured in Europe and Japan. And in the base of measurements, those were judged by subjective hearing test. As some results, it has been found that the room acoustics of churches were different in a country and the reverberation time was perferred two seconds for speech intelligibility. However, although personal deviations were admitted, more long echoes were preferred for the music.

  • PDF

Evaluation on Acoustic Performance of the DICT's Acoustic Loboratory (대우건설기술연구소 음향실험동의 성능 평가)

  • 정갑철;이주원;윤창연;박칠림
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.735-740
    • /
    • 1998
  • Acoustic performance of DICT's acoustic laboratory was evaluated. As a result, background noise and inverse squre law of an anechoic room were satisfied with ISO 3745 standard value. Also, reverberation time and standard deviation of sound pressure level distribution in reverberation rooms were within maximum error limit that was ruled on ISO 3741.

  • PDF

Design and Implementation of Trusted Chatting Room Using Software TPM (소프트웨어 TPM 을 사용한 신뢰형 채팅룸 설계 및 구현)

  • Kennedy, Chinyere Grace;Cho, Dong-Sub
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.259-261
    • /
    • 2012
  • Chatting room has become widely using technology and it is vulnerable to the internet attackers. We proposed a chatting system using a Purebasic programming language to communicate across networks system. Chatting room text is a form of instant messaging between two or group of people. A Communication experiment was designed and implemented to confirm the validity of the developed chatting system on a trusted platform.

  • PDF

A Study on the Waterproofing for Wet Structure Use of Room Temperature Vulcanization(RTV) Synthetic Rubber Sheet (상온가황형 합성고무시트를 이용한 습윤구조물 방수에 관한 연구)

  • 박동협;김영근;신주재;이대우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.545-548
    • /
    • 2003
  • The purpose of this study is measures vulcanization properties of matter by time of room temperature vulcanization synthetic rubber sheet and the evaluation adhesive properties tested by concrete surface moisture. Also, Its estimated reaction mechanism and adhesion performance between protection mortar and waterproofing layer. The results showed that vulcanization progressed in room temperature and adhesion intensity increased regardless of moisture condition.

  • PDF

A Study on the Preference and Using behavior of Residents According to Plan types of Master Room in Apartment Housing (아파트 부부공간 존 유형에 따른 거주자 사용행태 및 선호도)

  • Choi, Yu-Mi;Kang, Soon-Joo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.350-356
    • /
    • 2008
  • Recently, house market is focusing to consumer because competition between contractors is getting more deeply. So they are suppling various plans and changing space to confront lifestyle of consumers. This study has researched types of master rooms and analyzed the Preferences of users, so offers a basic material of master room zoning plan.

  • PDF

Ionic liquids to the rescue? Overcoming the ionic conductivity limitations of polymer electrolytes

  • Hendcrson W.A.;Shin J.H.;Alessandrini F.;Passcrini S.
    • 한국전기화학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.153-168
    • /
    • 2003
  • Polymer electrolytes - solid polymeric membranes with dissolved salts - are being intensively studied for use in all-solid-state lithium-metal-polymer consumer electronic device. The low ionic conductivity at room temperature of existing polymer electrolytes, however, has seriously hindered the development of such batteries for many applications. The incorporation of salts molten at room temperature (room temperature ionic liquids or RTILs) into polymer electrolytes may be the necessary solution to overcoming the inherent ionic conductivity limitations of 'dry' polymer electrolytes.

  • PDF