• Title/Summary/Keyword: 'room'

Search Result 15,343, Processing Time 0.04 seconds

Some characteristics of an interior explosion within a room without venting

  • Feldgun, V.R.;Karinski, Y.S.;Yankelevsky, D.Z.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.5
    • /
    • pp.633-649
    • /
    • 2011
  • The paper presents a study aimed at understanding some characteristics of an interior explosion within a room with limited or no venting. The explosion may occur in ammunition storage or result from a terrorist action or from a warhead that had penetrated into this room. The study includes numerical simulations of the problem and analytical derivations. Different types of analysis (1-D, 2-D and 3-D analysis) were performed for a room with rigid walls and the results were analyzed. For the 3D problem the effect of the charge size and its location within the room was investigated and a new insight regarding the pressure distribution on the interior wall as function of these parameters has been gained. The numerical analyses were carried out using the Eulerian multi-material approach. Further, an approximate analytical formula to predict the residual internal pressure was developed. The formula is based on the conservation law of total energy and its implementation yields very good agreement with the results obtained numerically using the complete statement of the problem for a wide range of explosive weights and room sizes that is expressed through a non-dimensional parameter. This new formula is superior to existing literature recommendations and compares considerably better with the above numerical results.

Analysis of Musculoskeletal Burdened Work among Nurses at a University Hospital (일개 대학병원 간호사의 근골격계 부담작업 분석)

  • Jeong, Eun-Hee;Koo, Jung‐Wan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.97-103
    • /
    • 2006
  • Severities of musculoskeletal diseases (MSDs) have been recognized at the regular work such as manufacturing but incidence of MSDs are increasing also at the atypical work. The examples of those are health medical workers, office workers and service workers etc. Nurses among health medical workers are accomplishing to manage and recover the patients' health in the first place. Therefore, they are exposed to very stressful work conditions during caring the patients. This study was performed to analyze the musculoskeletal burdened work among nurses at a university hospital, in order to grasp the realities of the MSDs, analyze and prevent MSDs. We surveyed risk factors for ward, intensive care unit, delivery room, newborn room, operation room, function test room and central supply room at a university hospital in Seoul. It was executed for 2 months as the field study that was composed of simulation, real measurement, work motion assessment and subjective assessment. And the results were analyzed into ergonomics techniques. Works according to the criteria of musculoskeletal burdened work by the Ministry of Labor were scrub in operation room and heart ultrasonic function test. And a lot of works that need attention and management were also detected. So it should be required the education and systematic managements of MSDs for nurses.

Analysis of the Condenser Performance Installed in the Air-Conditioning Plant Room of a High-Rise Building (고층 건물의 실외기실에 위치한 응축기 성능분석)

  • 최석호;이관수;김병순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.586-594
    • /
    • 2003
  • The performance of the condenser installed in the air-conditioning plant room of a high-rise building was studied numerically. The effect of the draft direction on the performance of an air-conditioner was analyzed. The on-coil temperature of the condenser was investigated by varying the arrangement and location o( the condenser in the air-conditioning plant room. The performance of an air-conditioner was also evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). The condenser in an air-conditioning plant room should be arranged in such a manner that the fan of the condenser is facing the outside of the building to exhaust the hot air directly, The model by which the condenser is located at the lower-left end of an air-conditioning plant room can prevent the hot air from reentering, and allow indrafting of fresh air. When the direction of draft is to the frontal face of the building, the performance of the condenser above 30th floor is degraded.

Changes in Physiologcal Properties of Garlic (Allium sativum L.) by Storage and Marketing Condition after Storage (저장 및 저장후 유통조건에 따른 마늘(Allium sativum L.)의 생리적 특성 변화)

  • 최선태;장규섭
    • Food Science and Preservation
    • /
    • v.5 no.2
    • /
    • pp.105-110
    • /
    • 1998
  • To find out suitable storage and marketing condition, northern type 'seosan' garlic was stored for 3 months at controlled atmosphere(CA), modified atmosphere(MA), low(0~1$^{\circ}C$) and room temperature(20$\pm$5$^{\circ}C$), and then marketed at low(2~3$^{\circ}C$) and room temperature (20$\pm$5$^{\circ}C$)after storage. The physiological properties of garlic were investigated among treatments. The garlic respiration increased after 2 months at room temperature storage, which seem to be dormancy break time. During storage of garlic by CA, MA condition, sprouting and weight loss were prevented effectively by suppress of respiration, and hardness was maintained higher then those of the others. Decay rate occurred 8.1% at room temperature storage, 2% at MA storage but didn't occurred at CA and low temperature storages. When marketed at room and low temperature after storage, increment of respiration and sprouting were delayed, and changes of weight and hardness were low in garlics stored at CA and MA. Decay rate occurred high in garlics stored at MA and room temperature.

  • PDF

A Study on the Design Trends and Characteristics of Flexible Housing Unit Plan in Korea (국내 아파트의 가변형 평면 계획 경향 및 특성에 관한 연구)

  • 이보라;김수암;이현수
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.189-194
    • /
    • 2002
  • This study aimed at the design trends and characteristics of flexible housing unit plan. In this paper, flexible unit plans of 256 examples that are constructed or will be constructed from 1991 to 2005 on the basis of the initial year of dwelling are analyzed. Divided into 60$m^2$, 85$m^2$, 102$m^2$, 135$m^2$, 165$m^2$ and above 180$m^2$ areas, kinds, characteristics and trend of planning of flexible housing unit plan are analyzed with the frequency and percentage method. The results of this study are as follows; 16 types of flexible kinds; room and living roon/room and room/room, room and living room. Since 2000, various types of flexible planning have came into existence (12 types of 16 types). 3bay is next to 4bay in number of flexible housing planning. There are R/L type in 3bay, R/L type and R/R types in 4bay. Flexible space organization is differentiated various types in R/L and public-private space has expanded in many ways.

  • PDF

Space study on Lighting Performance For Residential Buildings By using Simulation Analysis (시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구)

  • Lim, Tae Sub;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

A Study on Evaluation of Environmental Characteristics of Maternity Room (산후관리시설의 산모실 환경특성평가에 관한 연구)

  • Hwang, Yeon-Sook;Son, Yeo-Rym
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.6
    • /
    • pp.47-55
    • /
    • 2007
  • The purpose of this study is to evaluate environmental characteristics of maternity rooms. The method of this study is a field survey on 8 samples of postpartum care centers in Seoul. The plan, colors, materials, furniture and environmental characteristics of maternity rooms are analyzed. The characteristics of maternity rooms environment were categorized into four items; comfort, privacy, communication and dwelling. The results are as follows: Western-style and rooming-separation system of maternity rooms are used. Maternity rooms are generally good for dwelling quality but insufficient for communication. There are a lack of supply to control a temperature Individually in maternity rooms. It demands to make the type of one-sided public space between maternity room and living room for privacy. All of the maternity rooms surveyed are furnished with TV, radio, and telephone but, to improve communication with visitors, it is recommended that more convenient supplies such as audio and video system, chairs, and table be equipped. There are needs for sky-light windows in maternity rooms. It is necessary to research more about the space of living room, nursing room and service area, and we need more study about baby, nurser and owner' spaces.

A Study on The Chinese Traditional Wood-joints Applied to Furniture Design of Shelf - Focusing on One-room - (중국의 전통가구에 나타난 짜임기법이 적용된 원룸용 모듈형 가구디자인 개발)

  • Qin, Lu;Kim, Chung Ho
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.2
    • /
    • pp.95-102
    • /
    • 2017
  • In the process of changing from modern society to contemporary society, innovation of various fields is considered as important with rapid social change and one of the consequences of this changing movement is the innovation of living space. In this paper, based on this motive, we will study a modular shelf that can create a private space, and serve function like role of partition that delimits space in the one-room. Modular shelves can provide openness, closeness, and autonomy to individual spaces in a one-room space without space divisions. In a small one-room for residential purpose, it is able to function effectively to show the atmosphere of personal space and display small items reflecting personal taste in addition to the function of storing books and items. In addition, a modular shelves considering disassembly and movement are proposed in order to take advantage of one-room that can make different space configurations as needed. It is aim to suggest a basic modular shelves structure that used traditional Chinese wood-joints during which techniques was sturdy while reducing the use of timber. Futhermore, the purpose of this study is to study the design of shelf furniture that can add individuality.

A Study of the Space Planning of a University Library according to the Condition of the Information Environment - A Study on the Design of Library Architecture(II)- (정보환경조건에 따른 대학도서관의 공간계획에 관한 연구 -도서관 건축 디자인에 관한 연구(II)-)

  • 이상호;신현수
    • Korean Institute of Interior Design Journal
    • /
    • no.18
    • /
    • pp.31-37
    • /
    • 1999
  • This study aims to provide architectural basis of the new space planning in university library and anticipate direction in future. This study is to analyze the spatial transition in the existing facility, based on field observation of the domestic university library and on theoretical data from the related article. The result that include a transition of the existing facility and the present is as following as below. 1) Spatial transitions by networking are making specific system room. The minimum area of this specific system room is 33.95$m^2$. 2) Spatial transition by information service is forming computer room. the minimum area of a environmental carrel, which is possibly located to computer room, is 2.98~3.42$m^2$. 3) Spatial transition by spreading multimedia information is to make the multimedia information is to make the multimedia room. It is necessary to independent, flexibility, and extensionable space. 4) Library interior spatial transition by developing information technology is prospected that in case of reading room, office enlarge the scale, in case of stack decrease the scale. The university library must be kept up their function and also be functioned as electronic library which serve new information.

  • PDF

A Study on the Microstructure and Mechanical properties of Fe Aluminide alloys (Fe-Aluminide합금의 미세조직과 기계적 특성에 관한 연구)

  • Jo, Jong-Chun;Lee, Do-In;Lee, Seong-Jae;Choe, Byeong-Hak;Kim, Hak-Min
    • 연구논문집
    • /
    • s.22
    • /
    • pp.115-125
    • /
    • 1992
  • Mechanical properties and microstructure were investigated on vacuum induction melted $Fe_3A1$base alloys of $DO_3$ structure. Specal emphasis were put on the effect of alloy chemistry, grain size and process(rolling, directional solidification) on mechanical properties of Fe-22.5-39at.%Al at elevated temperature between room temperature and $800^{\circ}C$. grain size of as-cast alloys is refined by rolling from 1mm to $80\mum$. Tensile strength of Fe-24.lat.%AI was about 404MPa at the critical ordering temperature, and the fracture strain of the alloy was 1-2% at room temperature. An inverse temperature dependence of the strength is noticed as-cast $Fe_3A1$. The presence of Cr and Zr do not affect the room temperature ductility and high temperature strength. Fracture strain of directionally solidified(DS) $Fe_3A1$ is about 1%at room temperature, but is about 60%at. $T_C$(550^{\circ}C)$. Tensile strength of DS alloy is lower than that of as-cast alloy at $530^{\circ}C$ and $430^{\circ}C$. Failure mode at room temperature varies from transgranular fracture to intergranular fracture with the addition of Al. the failure mode also varies from mixed(transgranular+ intergranular) mode between room temperature and $500^{\circ}C$ to intergranular mode above $550^{\circ}C$

  • PDF