• Title/Summary/Keyword: %27Performance evaluation

Search Result 629, Processing Time 0.025 seconds

Operating Performance Evaluation of Landfill Facility and Landfill Gas (LFG) Energy Facility (매립시설 및 매립가스 에너지화시설 운영현황 분석)

  • Kim, Jong-Hwan;Phae, Chae-Gun;Park, Joon-Seok
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.221-232
    • /
    • 2018
  • This research was conducted to evaluate the operational performance of landfill facility and landfill gas energy facility from the questionnaire survey. In order to evaluate overall operational performance, three types of weighting methods were applied to each technical, economical, and environmental item. There was no significant difference between an equal weighted method, a weighted method of 40% for technology, 30% for economy, and 30% for environment, and a weighted method of 30% for technology, 40% for economy, and 30% for environment. In technical performance, large and middle scales of landfill facilities showed higher scores of 14.8 ~ 19.7 and 14.3 ~ 19.0 than 9.8 ~ 13.0 of small scale one. In environmental performance, large, middle, and small scales of landfill facilities showed 21.3 ~ 23.7, 17.6 ~ 19.6, and 20.8 ~ 23.1 scores, respectively. However, in economical performance, there was significant difference between them with scale. Large and middle scales of landfill facilities showed higher scores of 22.0 ~ 29.3 and 20.5 ~ 27.3 than 6.0 ~ 8.0 of small scale one. As a result of evaluation for landfill gas energy facility, large scale facility showed 19.2 ~ 25.6 and 17.8 ~ 23.7 scores in technical performance and 23.1 ~ 25.7 and 21.3 ~ 23.7 scores in environmental performance, respectively. However, in economical performance evaluation, large scale of landfill gas energy facility showed relatively higher of 27.8 ~ 33.3 score than 18.8 ~ 25.1 of small scale one. From these results, it was shown that economy evaluation heavily effect on the operational performance of landfill facility and landfill gas energy facility compared to technology and environment evaluation.

A Study on Shear and Flexural Performance Evaluation of Circularly Corrugated Plate (원형 파형강판의 전단 및 휨 성능평가에 관한 연구 -전단 및 휨강도 설계식 제안-)

  • Moon, Seong Hwan;Oh, Sang Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.455-470
    • /
    • 2015
  • This research suggest method to calculate more accurate shearing and bending force on corrugated steel plate that it is produced domestically. This research analyze limitation of former formula on domestic design standard and existing research. In addition The strength calculation formula on corrugated steel plate was proposed according to result of the experiment and FEM analysis. In this study, the result that compare experiment with analysis using the proposed shear buckling coefficient and limit width to thickness ratio indicate similar behavior. As the result of the research, It is judged that the structural member design and performance evaluation of the corrugated steel plate was conveniently applied.

Comparative Performance Evaluation of Advanced Daylighting Glazing Systems by Scale Model Measurements (축소모형을 이용한 가변 유리투과체의 채광유형별 성능평가 비교)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • The conventional way to acquire sufficient amount of daylight in interiors is to provide large openings with clear glass. The use of clear glass on the whole facade, however, might cause a sort of visual problem because of the harness of direct sun and brighter sky surface than expected. They should be filtered in opticalway or bounced in the architectural. One of the common solutions for the problem might be the use of photometric glasses with various transmittances for the glass walls. This paper deals with performance data related to the impact of various transmittal glazing materials for window systems in terms of daylighting. A series of scale model measurements was carried out with the fundamental configuration of a commonly used all-glass facades. Additionally some experimental performance index was issued for the better expression of the need of natural lighting.

Hierarchically Associated Quality Performance Measurements in Quality Management (계층유대에 의한 품질경영 성과측정)

  • Shin, Wan-Seon
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.163-182
    • /
    • 1999
  • Performance measurement is increasingly becoming a vital issue for promoting quality management within an organization. This research proposes a new performance measurement approach, called the Hierarchically Associated Performance Measurement, for the organizations which emphasize long term quality th겨st through a balanced interface between the quality efforts of various units. The proposed approach is unique in that it considers relationships between internal quality activities and national quality award criteria and that it identifies and utilizes the quality responsibilities of functional units in order to encompass organizational roles in the evaluation process. The approach is illustrated via a numerical evaluation of a fictitious organization.

  • PDF

A Fixed Grid Based Cache Algorithm for Performance Improvement in Internet Geographic Information System (인터넷 지리 정보 시스템에서의 성능 개선을 위한 고정 그리드 기반의 캐쉬 알고리즘)

  • Moon, Jin-Yong;Koo, Yong-Wan
    • Journal of Internet Computing and Services
    • /
    • v.1 no.1
    • /
    • pp.27-34
    • /
    • 2000
  • Recently, the use of Geographic Information System in each field of our society is on the increase according to the development of the Internet. But, thereis a problem of the user access latencies, the network traffic, and the server overload in Internet Geographic Information System because spatial data are transferred in large volumes. In this paper, we propose a cache algorithm on client side to solve the above problems. The proposed algorithm demonstrates the performance improvement over known studies by utilizing unit time and spatial proximity. In addition, this paper conducts a performance evaluation to measure the improvement in algorithm efficiency and analyzes the results of the performance evaluation. When spatial data queries are conducted, according to our performance evaluation, hit rate has been improved over the existing algorithms.

  • PDF

Quality Evaluation of Alismatis Rhizoma by High Performance Liquid Chromatography

  • Lee Sang-Myung;Kang Jong-Seong;Hwang Gwi-Seo;Kim Young-Ho;Lee Cheal-Gyu;Yeo Woon-Hyung;Bae Ki-Hwan
    • Archives of Pharmacal Research
    • /
    • v.27 no.4
    • /
    • pp.460-464
    • /
    • 2004
  • The quality of Alismatis Rhizoma was evaluated by reversed-phase high performance liquid chromatographic method. Alisol B 23-acetate was used as a standard marker for evaluation. This component was fully separated from the other components in the plant extracts on a ODS column. Identifcation of alisol B 23-acetate was carried out by comparing the LC/MS spectrum of separated peak from the extract with that of standard. Alisol B 23-acetate contents in Alismatis Rhizoma obtained from several herbal markets were varied from $0. 15\%$ to $0.56\%$.

Development Strategies for Existing Apartment Housing Remodeling Performance Grading Indication System (공동주택 리모델링 성능등급 개발방향 설정)

  • Baek, Cheong-Hoon;Kim, Soo-Am;Yang, Hyeon-Jeong
    • Journal of the Korean housing association
    • /
    • v.27 no.4
    • /
    • pp.23-32
    • /
    • 2016
  • The necessity of remodeling performance grading system is getting increased for the systematic management of existing housing stock, providing the resident's right to know and promoting the remodeling projects. A quantitative and objective evaluation method that has reflected the characteristics of remodeling must be developed because there is an aspect of having difficulty of assessment by an ordinary person as remodeling performance contains specialized details while the difficulty of applying the criteria of new buildings in terms of assessment items, criteria and methods. Accordingly, this study sets the goal as setting up the development objectives of performance grading system that has considered the remodeling characteristics. This study has analyzed the various assessment systems related to the domestic apartments as well as setting up the organization system of the remodeling performance grading system, perspectives of performance assessment and scope of assessment through literature, etc. It has also established the principles for setting up the assessment items of remodeling performance grade to present the directions for setting up assessment items and criteria.

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Neuro-Fuzzy Diagnostic Technique for Performance Evaluation of a Chiller (뉴로 퍼지를 이용한 냉동기 성능 진단 기법)

  • Shin, Young-Gy;Chang, Young-Soo;Kim, Young-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.553-560
    • /
    • 2003
  • On-site diagnosis of chiller performance is an essential step fur energy saving business. The main purpose of the on-site diagnosis is to predict the COP of a target chiller. Many models based on thermodynamics background have been proposed for this purpose. However, they have to be modified from chiller to chiller and require deep insight into thermodynamics that most of field engineers are often lacking in. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). Quality of the training data for ANFIS, sampled over June through September, is assessed by checking COP prediction errors. The architecture of the ANFIS, its error bounds, and collection of training data are described in detail.

Design, Fabrication, and Performance Evaluation of a Sensorized Superelastic Alloy Microrobot Gripper (센서화된 초탄성 마이크로그리퍼의 설계, 제작 및 성능평가)

  • Kim, Deok-Ho;Kim, Byung-Kyu;Kang, Hyun-Jae;Kim, Sang-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1772-1777
    • /
    • 2003
  • This paper presents the design, fabrication, and calibration of a piezoelectric polymer-based sensorized microgripper. Electro discharge machining technology is employed to fabricate super-elastic alloy based micro gripper. It is tested to present improvement of mechanical performance. For integration of force sensor on the micro gripper, the sensor design based on the piezoelectric polymer PVDF film and fabrication process are presented. The calibration and performance test of force sensor integrated micro gripper are experimentally carried out. The force sensor integrated micro gripper is applied to perform fme alignment tasks of micro opto-electrical components. It successfully supplies force feedback to the operator through the haptic device and plays a main role in preventing damage of assembly parts by adjusting the teaching command.