• Title/Summary/Keyword: %24CO_2%24 concentration

Search Result 575, Processing Time 0.032 seconds

Development of A Two-Variable Spatial Leaf Photosynthetic Model of Irwin Mango Grown in Greenhouse (온실재배 어윈 망고의 위치 별 2변수 엽 광합성 모델 개발)

  • Jung, Dae Ho;Shin, Jong Hwa;Cho, Young Yeol;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.161-166
    • /
    • 2015
  • To determine the adequate levels of light intensity and $CO_2$ concentration for mango grown in greenhouses, quantitative measurements of photosynthetic rates at various leaf positions in the tree are required. The objective of this study was to develop two-variable leaf photosynthetic models of Irwin mango (Mangifera indica L. cv. Irwin) using light intensity and $CO_2$ concentration at different leaf positions. Leaf photosynthetic rates at different positions (top, middle, and bottom) were measured by a leaf photosynthesis analyzer at light intensities (0, 50, 100, 200, 300, 400, 600, and $800{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) with $CO_2$ concentrations (100, 400, 800, 1200, and $1600{\mu}mol{\cdot}mol^{-1}$). The two-variable model consisted of the two leaf photosynthetic models expressed as negative exponential functions for light intensity and $CO_2$ concentrations, respectively. The photosynthetic rates of top leaves were saturated at a light intensity of $400{\mu}mol{\cdot}^{-2}{\cdot}s^{-1}$, while those of middle and bottom leaves saturated at $200{\mu}mol{\cdot}^{-2}{\cdot}s^{-1}$. The leaf photosynthetic rates did not reach the saturation point at a $CO_2$ concentration of $1600imolmol^{-1}$. In validation of the model, the estimated photosynthetic rates at top and bottom leaves showed better agreements with the measured ones than the middle leaves. It is expected that the optimal conditions of light intensity and $CO_2$ concentration can be determined for maximizing photosynthetic rates of Irwin mango grown in greenhouses by using the two-variable model.

Effects on Physiological Activities Caused by Oxygen Deficiency and Exposure to Noxious Gases in SD Rats (Rat를 이용 산소 및 유해가스 노출에 따른 운동성 변화와 치사농도 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Kang, Min-Gu;Ye, Byeong-Jin
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.181-191
    • /
    • 2009
  • As an effort to prevent serious accidents involving oxygen deficiency and suffocation in confined spaces and to identify the causes of such accidents, the present study investigated relevant accidents and systems in Korea and other countries. This study also conducted a number of experiments at lethal concentration levels of oxygen deficiency using SD rats and observed the changes of experimental animals with humidity, organic gas (toluene), hydrogen sulfide, carbon monoxide and so on at the oxygen deficient environment. The results of the study are as follows. 1. The results from the experiment conducted using SD rats at lethal concentration levels of oxygen showed that there were no casualties at the 7% oxygen concentration level, but the mortality increase to 20% at 6% oxygen, it was jumped to 90% at 5% oxygen, and it was also dramatically reached 100% at 4% oxygen concentration. Therefore, 5.5% was calculated as the $LC_{50}$ (rat, 4hr) from these dose-response experiments with oxygen deficiency. 2. When we changed the level of toluene, $H_2S$, CO, humidity, and so on, in an oxygen deficient environment, it was observed that the small concentrations of $H_2S$ and CO make the highest effect on animals. In case of 350 ppm $H_2S$, it resulted in 30% mortality, and the 100% mortality was shown in 1,200 ppm CO concentration. The mortality increased as an oxygen deficient condition. However in the case of toluene up to 1,000 ppm, it were not affected with oxygen deficiency, and it did not indicate any significant differences in mortality as 20%, 90% humidities.

Effects of Elevated $CO_2$ Concentration and Temperature on Growth Response of Quercus acutissima and Q. variabilis (지구온난화에 따른 상수리나무와 굴참나무의 생육반응에 관한 연구)

  • Jeong, Jung-Kyu;Kim, Hae-Ran;You, Young-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.6
    • /
    • pp.648-656
    • /
    • 2010
  • Global warming brings changes of natural ecosystems and affects on the plant growth response. Quercus acutissima and Q. variabilis are taxonomically similar and dominant native species in deciduous forests in South Korea. In order to understand the growth response of Q. acutissima and Q. variabilis to global warming condition, we cultivated the seedling of the two oak species in ambient condition(control) and treatment with elevated $CO_2$(700~800ppm) and increased air temperature(approximately $3^{\circ}C$ above than control). Then we measured the growth characteristic among them and analyzed the relationship between two species using PCA ordination. Stem length and total plant weight of Q. acutissima were significantly affected by elevated $CO_2$ concentration and increased air temperature. Stem diameter and weight of Q. variabilis were significantly affected by elevated $CO_2$ concentration and increased air temperature(p<0.05). The variation characteristics of Q. acutissima were changed more than Q. variabilis by elevated $CO_2$ concentration and increased air temperature. These result suggested that Q. acutissima was more sensitive to global warming situation than Q. variabilis in central region of Korea. PCA ordination showed that two species were arranged by two distinct groups based on 10 characters by elevated $CO_2$ and increased air temperature.

The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju (광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석)

  • Lee, Dae-Haeng;Lee, Se-Haeng;Bae, Seok-Jin;Kim, Nan-Hee;Park, Kang-Soo;Kim, Do-Sool;Paik, Ke-Jin;Moon, Yong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1001-1010
    • /
    • 2010
  • The purpose of this study is to investigate the concentration levels of particle materials ($PM_{10}$, asbestos), gas materials ($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs) and total suspended colony (TSC), and the correlations among these materials in indoor air quality of 54 multiple-use facilities and 15 public-use facilities of Gwangju. The highest mean concentration of $PM_{10}$ was $69.2\;{\mu}g/m^3$ at indoor parking place, followed by childcare facilities, large commercial building and subway station building. The highest mean concentration of CO was 2.7 ppm at indoor parking place and that of $CO_2$ was 604.1 ppm at medical service facilities. The highest mean concentration of $NO_2$ was 0.036 ppm at indoor parking place. The geomean concentration of HCHO was $3.6\;{\mu}g/m^3$ in all facilities and the highest was $631.8\;{\mu}g/m^3$ at art gallery. The geomean concentration of VOCs (5 species) was $24.14\;{\mu}g/m^3$ in all facilities and toluene was the highest material of $15.30\;{\mu}g/m^3$, followed by xylene, ethylbenzene, benzene and styrene. The highest mean concentration of TSC was $625.3\;CFU/m^3$ at jjimjilbang, followed by childcare facilities, medical service facilities and large commercial building. The highest of asbestos was 0.0072 each/cc at childcare facilities and that of radon was 1.41 pCi/L at art gallery. PM10 showed positive correlations to TSC with $R^2\0.5332$ by lognormal equation at childcare facilities. CO2 showed positive correlations to CO at childcare facilities and indoor parking place. Lognormal equation fitted to the VOCs data more than normal equation in all facilities.

Adsorption of MX (3-chloro-4 (dichloromethyl)-5-hydroxy-2-(5H)-furanone) on amphiphilic mesoporous silica in aqueous solution (양쪽성 메조 포러스 실리카에 의한 수용액 속의 MX의 흡착)

  • Yoo, Eun-Ah;Chung, Kang-Sup
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.94-104
    • /
    • 2011
  • Mesoporous silica was synthesized in a water solvent and in an ethanol solvent with the non and cationic cetyltrimethyl ammonium chloride (CTAC) by varying the amount of the amphiphilic acrylic urethane oligomer (AAU) and the pH of the solution. The adsorption of the MX (3-chloro-4 (dichloromethyl)-5-hydroxy-2-(5H)-furanone) in drinking water was studied using the synthesized mesoporous silica as an adsorbent. The most appropriate silica was synthesized in acidic conditions in the water solvent and in alkali conditions in the ethanol solvent. The average pore sizes of the synthesized mesosilica were 3 nm and more. The mesoporous silica synthesized by the addition of the AAU oligomer showed excellent adsorption characteristics. With respect to the co-surfactant, the best adsorption characteristics were obtained when the P64,a non-ionic surfactant with a high molecular weight, was used to synthesize the silica than when other co-surfactants were used. The adsorption rate decreased as the MX concentration in the water increased. Different adsorption equilibrium conditions were reached depending on the adsorbate MX concentration in the adsorbent and the solution. It was seen that perfect adsorption does not occur due to such equilibrium conditions.

Syngas/Diesel Dual Fuel Combustion in a Compression Ignition Engine with Different Composition Ratios of Syngas and Compression Ratios (합성가스/디젤 혼소압축착화 엔진의 합성가스 혼합비와 압축비에 따른 연소 및 배출가스 특성)

  • Lee, Junsun;Chung, Tahn;Lee, Yonggyu;Kim, Changup;Oh, Seungmook
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2019
  • Syngas is widely produced by incomplete combustion of coal, water vapor, and air (oxygen) in a high-temperature/high-pressure gasifier through a coal-gasification process for power generation. In this study, a simulation syngas which was mainly composed of $H_2$, CO, $CO_2$, and $N_2$ was fueled with diesel. A modified single cylinder compression ignition (CI) engine is equipped with intake port syngas supply system and mechanical diesel direct injection system for dual fuel combustion. Combustion and emission characteristics of the engine were investigated by applying various syngas composition ratios and compression ratios. Diesel fuel injection timing was optimized to increase indicated thermal efficiency (ITE) at the engine speed 1,800 rpm and part load net indicated mean effective pressure ($IMEP_{net}$) 2 to 5 bar. ITE of the engine increased with the $H_2$ concentration, compression ratio and engine load. With 45% of $H_2$ concentration, compression ratio 17.1 and $IMEP_{net}$ 5 bar, ITE of 41.5% was achieved, which is equivalent to that of only diesel fuel operation.

Determination of Total CO2 and Total Alkalinity of Seawater Based on Thermodynamic Carbonate Chemistry (해수중의 총이산화탄소와 총알칼리도 분석을 위한 탄산염 화학 이론 및 측정방법)

  • Mo, Ahra;Son, Juwon;Park, Yongchul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • To evaluate accuracy and precision of determination of total alkalinity ($Alk_T$) and carbon dioxide ($TCO_2$) derived from present study, experiment was applied with $CO_2$ CRM (Batch 132, Scripps Institution of Oceanography; $Alk_T=2229.24{\pm}0.39{\mu}mol/kg$, $TCO_2=2032.65{\pm}0.45{\mu}mol/kg$). As the result, average concentration of $Alk_T$ and $TCO_2$ was $2354.09{\mu}mol/kg$ (~5.6% difference with $CO_2$ CRM) and $2089.60{\mu}mol/kg$ (~2.3% difference with $CO_2$ CRM), respectively. For previous method (Gran Titration) by addition $NaHCO_3$ to deionized water($Alk_T$ $2023.33{\mu}mol/kg$), average concentration was $2193.39{\mu}mol/kg$ (sd=57.15, n=7). Whereas, average concentration was $2017.02{\mu}mol/kg$ (sd=10.98, n=7) for the present study. Recovery yield experiments of total alkalinity in deionized water and seawater were implemented by addition of $NaHCO_3$. The recovery yield of deionized water in the range 0 to $4952.39{\mu}mol/kg$ was 100.8% ($R^2$=0.999), and seawater in the range 0 to $2041.32{\mu}mol/kg$ was 102.3% ($R^2$=0.999). Comparison of $pCO_2$ sensor (PSI $CO_2-Pro^{TM}$) with present method showed very meaningful correlation coefficient ($R^2$=0.977) in the range of 427 to $705{\mu}atm$ and 9.16 to $15.24{\mu}mol/kg$ throught elapsed time for two weeks. Field experiment of diurnal variation of total carbon dioxide was accomplished at Sachon harbor in the coastal waters of East Sea of Korea. Concentration of $Alk_T$ and $TCO_2$ was increased during night, and decreased during daylight hours. The results showed mirror type between $TCO_2$ and dissolved oxygen, which was attributable to photosynthesis and respiration of phytoplankton. Also, open ocean field study was performed to obtain vertical profile of $Alk_T$ and $TCO_2$ in C-C zone (Clarion-Clipperton Fracture Zone), Northeastern Pacific. Average concentrations of $Alk_T$ in the surface mixed layer (0~60 m) and deeper layer below 200 m were $2422.38{\mu}mol/kg$ (sd=78.73, n=20) and $2465.87{\mu}mol/kg$ (sd=57.68, n=103), respectively. And average concentrations of $TCO_2$ were $2134.47{\mu}mol/kg$ (sd=65.4, n=20) and $2431.87{\mu}mol/kg$ (sd=65.02, n=103) in the same depth ranges such as $Alk_T$. Vertical distributions of $Alk_T$ and $TCO_2$ concentrations tended to increase with depth, and analyzed concentrations showed slightly higher than those of previous studies in this area.

A Study on the Characteristics of Antecedent Meteorologic Conditions on High Ozone Days in Busan (부산지역 고농도 오존일의 선행 기상 특성 연구)

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.993-1001
    • /
    • 2015
  • Comparing to the other air pollutants like $SO_2$, CO, the number of exceedance of the ozone national ambient air quality standard(NAAQS) and the ozone warning increased recently in Busan. The purpose of this study is to find out the preliminary symptoms for high ozone days in Busan area. In order to find out the preliminary symptoms, the hourly ozone data at air quality monitoring stations and the hourly meterological parameters at Busan regional meteorological 2007 to 2013 were used for the analysis. Averaged daily max ozone concentration was the highest(0.055 ppm) at Noksan and Youngsuri in the ozone season from 2007 to 2013. The horizontal distributions of daily max. ozone including all stations in Busan at high ozone days(the day exceeding 0.1 ppm of ozone concentration at least one station) were classified from two to five clusters by hierarchial cluster analysis. The meteorological variables showing strong correlation with daily max. ozone were the daily mean dew point temperature, averaged total insolation, the daily mean relative humidity and the daily mean cloud amount. And the most frequent levels were $19-23^{\circ}C$ in dew point temperature, $21-24 MJ/m^2$ in total insolation on the day before, $2.6-3.0 MJ/m^2$ on the very day, 67-80% in relative humidity and 0-3 in cloud amount.

Bioequivalence of AmbrectTM Tablet to MucopectTM Tablet (Ambroxol hydrochloride 30 mg) (뮤코펙트 정(염산암브록솔 30 mg)에 대한 암브렉트 정의 생물학적 동등성)

  • Yoo, Jeong-Yeon;Joung, Sun-Koung;Choi, Mee-Hee;Han, Sang-Beom;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.3
    • /
    • pp.215-221
    • /
    • 2003
  • A bioequivalence study of $Ambrect^{TM}$ tablets (Dong Wha Pharm. Ind. Co., Ltd.) to $Mucopect^{TM}$ tablets (Boehringer Ingelheim Korea, Ltd.) was conducted according to the guideline of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korea volunteers received each medicine at the ambroxol hydrochloride dose of 30 mg in a $2{\times}2$ crossover study. There was a one-week wash out period between the doses. Plasma concentrations of ambroxol were monitored by a high-performance liquid chromatography for over a period of 24 hours after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calulated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}\;(time\;to\;reach\;C_{max})$ were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Ambrect^{TM}/Mucopect^{TM}$ were 0.89-1.01 and 0.89-1.02, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Ambrect^{TM}\;and\;Mucopect^{TM}$ with respect to the rate and extent of absorption.

Pb Biosorption by Saccharomyces cerevisiae (Saccharomyces cerevisiae에 의한 Pb 생체흡착)

  • 안갑환;서근학
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.173-180
    • /
    • 1996
  • The contamination of the environment by heavy metals results in a serious public health problem due to the toxicity of those pollutants even at low concentrations. Microorganisms may be used to remediate wastewaters contamlialtd with heavy metals. The waste S. cerevisiae is an inexpensive readily available source of biomass for bioremediation of wastewater. S. cerevisiae was investigated for their ability to absorb Pb. The crushed biomass of S. cerevisiae exhibited higher Pb uptake capacity than the living S. cerevisiae and the sterilized S. cerevisiae. At the same metal concentration, metal uptake per unit concentration or adsorbent decreased when the biomass concentration rises. The order of the biosorption capacity of the living S. cerevisiae was Pb>Cu>Cd=Co>Cr. When S. cerevisiae was pretreated with 0.1 M NaOH, Pb uptake was increased by 150 percent and 0.1 M HC1, 0.1 M $H_2S_O4$ solutions were efficient in the desorption of Pb. The sorption equilibrium of Pb ions can be described by the Freundlich and Langmuir models.

  • PDF