• Title/Summary/Keyword: % RSD

Search Result 531, Processing Time 0.023 seconds

Analytical method validation of oxiracetam using HPLC (HPLC를 이용한 의약품 주성분인 옥시라세탐의 Analytical Method Validation)

  • Kim, Yoo-Gon;Seo, Houng-Seok;Won, Chan-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.587-594
    • /
    • 2010
  • This study aims to determine that the test of medicines containing oxiracetam as their main ingredient was properly performed according to protocol. Furthermore, the study is to provide the written form of protocol in order to examine the validity of the HPLC analytical method for the quantitative analysis of oxiracetam in the finished products. In this experiment, system suitability, precision, linearity, range, accuracy, specificity, quantitative limit, and detection limit of the analytical method which was used to determine the contained quality of oxiracetam, were examined. The result shows that system suitability indicates 0.127% RSD, plate number 15081, tailing factor 0.49, and resolution 32.41. The experiment of precision reveals the result of below 0.359% for repetitiveness and among the subjects. In the linearity experiment, a coefficient of correlation ($R^2$) indicates that it is 1. The accuracy experiment satisfies the standards of the recovery test, which is minimum 98.4% and maximum 99.6%. Detection limit is 0.1 mg/L and quantitative limit was found to be 0.5 mg/L. The experiment to check the specificity also satisfies the standards, so the finished product using oxiracetam as the main ingredient is verified as suitable.

Experience with the Application of Magnetic Resonance Diagnostic $Analyser^{(R)}$ -A case of reflex sympathetic dystrophy- (자기공명분석기에 의한 반사성 교감신경성 위축증의 치험)

  • Kim, Jin-Soo;Kwak, Su-Dal;Kim, Jun-Soon;Ok, Sy-Young;Cha, Young-Deog;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.275-279
    • /
    • 1993
  • Reflex sympathetic dystrophy is a syndrome characterized by persistent, burning pain, hyperpathia, allodynia & hyperaesthesia in an extremity, with concurrent evidence of autonomic nervous system dysfunction. It generally develops after nerve injury, trauma, surgery, et al. The most successful therapies are directed towards blocking the sympathetic intervention to the affected extremity by regional sympathetic ganglion block or Bier block with sympathetic blocker; other traditional treatments include transcutaneous electrical stimulation, immobilization with cast & splint, physical therapy, psychotherapy, administration of sympathetic blocker, calcitonin, corticosteroid and analgesic agents. The purpose of this report is to evaluate and describe the effects of magnetic resonance following unsatisfactory results with traditional treatments of RSD. A 17 year old female patient, 1 year earlier, had received excision and drainage of pus at the right femoral triangle due to an injury caused by a stone. Afterwards, she experienced burning pain, knee joint stiffness, and muscle dystrophy of the right thigh, especially when standing and walking. Despite a year of number of traditional treatments such as: lumbar sympathetic block, continuous epidural analgesia, transcutaneous electrical stimulation, & administration of predisolone, her pain did not improve. Surprisingly, the patients was able to walk free from pain and difficulty after just one application of magnetic resonance. The patient has been successfully treated with further treatment of two to three times a week for approximately ten weeks. More recently, magnetic resonance has been demonstrated to produce effective results for the relief of pain in a variety of diseases. From our experiences we recognize magnetic resonance as a therapeutic modality which can provide excellent results for the treatment of RSD. It has been suggested that polysynaptic reflex which are disturbed in RSD may be modulated normally on the spinal cord level through the application of magnetic resonance.

  • PDF

Analysis of Cadaverine and Its Worker Honeybee Venom Content (Apis mellifera L.) (꿀벌(Apis mellifera L.) 일벌독의 생체아민 cadaverine 함량 및 분석법)

  • Choi, Hong Min;Kim, Hyo Young;Kim, Se Gun;Han, Sang Mi
    • Journal of Life Science
    • /
    • v.31 no.2
    • /
    • pp.144-148
    • /
    • 2021
  • This study aimed to analyze the content and composition of a biological amine, cadaverine, isolated from the venom of worker honeybees (Apis mellifera L.). This biological amine―which has diverse functionality, such as anti-inflammatory and antibacterial effects―has not been previously reported in bee venom. An assay completed in 13 minutes was developed for the cadaverine present in the bee venom using an ultra-performance liquid chromatograph and a Halo C18 column with acetonitrile and water as the mobile phase. The specificity, accuracy, and precision of the assay were verified, and the assay was validated. The linearity for cadaverine in the bee venom was R2=0.99 or above, indicating a moderate level. The limit of detection and limit of quantification were both 0.3 ㎍/ml, and the rate of recovery was 97.6%-99.1%. The relative standard deviation (RSD) of the intra-day precision and inter-day precision for cadaverine was 0.25%-0.44% and 0.25%-1.25%, respectively, with an RSD that fell within 5% indicating excellent precision. Through this novel assay, it was found that the mean content of cadaverine was 1.10±0.05 mg/g. Our results indicated that the linearity, limit of detection, limit of quantification, and rate of recovery of the cadaverine assay were of a satisfactory level, and the cadaverine content of the bee venom was ably determined. This study provides basic data on cadaverine in bee venom, which will prove useful in further studies on the bioactivity of this component.

Determination of Sodium Alginate in Processed Food Products Distributed in Korea

  • Yang, Hyo-Jin;Seo, Eunbin;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.474-480
    • /
    • 2021
  • Sodium alginate is the sodium salt of alginic acid, commonly used as a food additive for stabilizing, thickening, and emulsifying properties. A relatively simple and universal analysis method is used to study sodium alginate due to the complex pretreatment process and extended analysis time required during the quantitative method. As for the equipment, HPLC-UVD and Unison US-Phenyl column were used for analysis. For the pretreatment condition, a shaking apparatus was used for extraction at 150 rpm for 180 minutes at room temperature. The calibration curve made from the standard sodium alginate solution in 5 concentration ranges showed that the linearity (R2) is 0.9999 on average. LOD and LOQ showed 3.96 mg/kg and 12.0 mg/kg, respectively. Furthermore, the average intraday and inter-day accuracy (%) and precision (RSD%) were 98.47-103.74% and 1.69-3.08% for seaweed jelly noodle samples and 99.95-105.76% and 0.59-3.63% for sherbet samples, respectively. The relative uncertainty value was appropriate for the CODEX standard with 1.5-7.9%. To evaluate the applicability of the method developed in this study, the sodium alginate concentrations of 103 products were quantified. The result showed that the detection rate is highest from starch vermicelli and instant fried noodles to sugar processed products.

Determination of Sulfonamides in Meat by Liquid Chromatography Coupled with Atmospheric Pressure Chemical Ionization Mass Spectrometry

  • Kim, Dal-Ho;Choi, Jong-Oh;Kim, Jin-Seog;Lee, Dae-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1590-1594
    • /
    • 2002
  • Liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) has been used for the determination of sulfonamides in meat. Five typical sulfonamides were selected as target compounds, and beef meat was selected as a matrix sample. As internal standards, sulfapyridine and isotope labeled sulfamethazine (${13}^C_6$-SMZ) were used. Compared to the results of recent reports, our result have shown improved precision to a RSD of 1.8% for the determination of sulfamethazine spiked with 75 ng/g level in meat.

고상미량추출장치(SPME)를 이용한 유류 오염 지하수 평가 기법 연구

  • 조현정;백기태;박지연;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.148-150
    • /
    • 2001
  • Solid-phase microextraction (SPME) was investigated to understand the BTEX extraction behavior of SPME in groundwater. Analytical procedure was conducted In both conventional and headspace mode. And the conventional direct extraction method and the headspace analysis method were compared. Data obtained with direct and headspace SPME were very similar and showed successful results. In headspace analysis, the linearity was better and RSD (relative standard deviation, %) was smaller than direct extraction.

  • PDF

A STUDY ON ANNIHILATOR CONDITIONS OF POLYNOMIALS

  • Cho, Yong-Uk
    • Bulletin of the Korean Mathematical Society
    • /
    • v.38 no.1
    • /
    • pp.137-142
    • /
    • 2001
  • In this paper, we initiate the study of some annihilator conditions on polynomials which were used by Kaplansky [4] to abstract algebras of bounded linear operators on a Hilbert spaces with Baer condition. On the other hand, p.p. rings were introduced by A. Hattori [3] to study the torsion theory. The purpose of this paper is to introduce near-rings with Baer condition and near-rings with p.p. condition which are somewhat different from the ring case, and to extend a results of Armendarz [1] to polynomial near-rings with Baer condition in somewhat different way of Birkenmeier and Huang [2].

  • PDF

Raindrop Size Distribution Over Northeastern Coast of Brazil

  • Tenorio Ricardo Sarmento;Kwon Byung-Hyuk;Silva Moraes Marcia Cristina da
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2006
  • Precipitation measurement with ground-based radar needs an information of the raindrop size distribution (RSD) characteristics. A 10-month dataset was collected in tropical Atlantic coastal zone of northeastern Brazil where the weather radar was installed. The number of drop was mainly recorded in 300 - 500 drop $mm^{-3}$, of which the maximum was registered around 1.1 mm drop diameter.

Determination of Trace Metals in Atmospheric Particulates by Ion Chromatography

  • Lee Yong-Keun;Kim Hak-Chul;Lee Dong Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1045-1049
    • /
    • 1994
  • A simple and fast ion chromatographic method is developed for the determination of transition metals such as Fe, Cu, Ni, Zn and Co in atmospheric particulates. The method involves acid digestion, on-column preconcentration, and subsequent ion chromatogaphic detection. The precision of the method is less than 3${\%}$ RSD at parts per billion level for the metals studied. No significant interferences are observed. The results obtained with this method agree well with those by ICP-AES.

A New On-line Coprecipitation Preconcentration Technique for Trace Metal Analysis by ICP-AES

  • Park, Gyeong Hui;Park, Yong Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.422-427
    • /
    • 1995
  • In a stream of water sample, trace metal ions are quantitatively coprecipitated with Indium hydroxide and filtered. The filtered precipitate is continuously dissolved in 3 M nitric acid and introduced to ICP directly. The lead, cadmium, and copper are concentrated more than 10-fold and determined with ICP-AES at a sampling frequency of 10/hour. The detection limits are 2.89, 1.43,0.52 ppb for lead, cadmium, and copper respectively. Recoveries of lead, cadmium, and copper are 98.7, 94.3, and 104.5% respectively. The RSD values for three elements are about 3-5% currently.