• Title/Summary/Keyword: $k_0$ factor

Search Result 12,176, Processing Time 0.042 seconds

Piezoelectric Characteristics of PMW-PNN-PZT Ceramics for Actuator Application (액츄에이터용 PMW-PNN-PZT 세라믹스의 압전특성)

  • Yoo, Kyung-Jin;Yoo, Ju-Hyun;Yoon, Hyun-Sang;Park, Chang-Yeop;Jeong, Yeong-Ho;Lee, Hyung-Gyu;Kang, Hyung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.332-333
    • /
    • 2005
  • In this study, in order to develop low temperature sintering piezoelectric actuator, $Pb(Mg_{1/2}W_{1/2})_{0.03}(Ni_{1/3}Nb_{2/3})_x(Zr_{0.50},Ti_{0.50})_{1-x-0.03}$ (PMW-PNN-PZT) ceramic systems were fabricated using $CaCO_3-Li_2CO_3$ sintering aid and their dielectric and piezoelectric properties were investigated with the variation of PNN substitution. The piezoelectric actuator requires high piezoelectric constant $d_{33}$ and high electromechanical coupling factor kp. At the PMW-PNN-PZT ceramics with 9mol% PNN substitution sintered at $900^{\circ}C$, the density, electromechanical coupling factor kp, dielectric constant, piezoelectric constant $d_{33}$ and mechanical quality factor Qm showed the excellent values of 7.86 [$g/cm^3$], 0.584, 1881, 485 [pC/N] and 76, respectively for piezoelectric actuator application.

  • PDF

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

Effect of Polysaccharides from Acanthopanax senticosus on Intestinal Mucosal Barrier of Escherichia coli Lipopolysaccharide Challenged Mice

  • Han, Jie;Xu, Yunhe;Yang, Di;Yu, Ning;Bai, Zishan;Bian, Lianquan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.1
    • /
    • pp.134-141
    • /
    • 2016
  • To investigate the role of polysaccharide from Acanthopanax senticosus (ASPS) in preventing lipopolysaccharide (LPS)-induced intestinal injury, 18 mice (at 5 wk of age) were assigned to three groups with 6 replicates of one mouse each. Mice were administrated by oral gavage with or without ASPS (300 mg/kg body weight) for 14 days and were injected with saline or LPS at 15 days. Intestinal samples were collected at 4 h post-challenge. The results showed that ASPS ameliorated LPS-induced deterioration of digestive ability of LPS-challenged mice, indicated by an increase in intestinal lactase activity (45%, p<0.05), and the intestinal morphology, as proved by improved villus height (20.84%, p<0.05) and villus height:crypt depth ratio (42%, p<0.05), and lower crypt depth in jejunum (15.55%, p<0.05), as well as enhanced intestinal tight junction proteins expression involving occludin-1 (71.43%, p<0.05). ASPS also prevented intestinal inflammation response, supported by decrease in intestinal inflammatory mediators including tumor necrosis factor ${\alpha}$ (22.28%, p<0.05) and heat shock protein (HSP70) (77.42%, p<0.05). In addition, intestinal mucus layers were also improved by ASPS, as indicated by the increase in number of goblet cells (24.89%, p<0.05) and intestinal trefoil peptide (17.75%, p<0.05). Finally, ASPS facilitated mRNA expression of epidermal growth factor (100%, p<0.05) and its receptor (200%, p<0.05) gene. These results indicate that ASPS can prevent intestinal mucosal barrier injury under inflammatory conditions, which may be associated with up-regulating gene mRNA expression of epidermal growth factor and its receptor.

Dielectric and Piezoelectric Characteristics of PMW-PNN-PT-PZ Ceramics with addiction of MnO$_2$ (MnO$_2$가 첨가된 PMW-PNN-PT-PZ계 세라믹스의 유전 및 압전 특성)

  • 박석환;윤광희;박정흠;김현재;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.63-67
    • /
    • 1996
  • In this paper, effect of MnO$_2$ addition(0, 0.1, 0.2, 0.3, 0.5wt%) on the microstructure, dielectric and piezoelectric properties of [xPMW - (0.15-x) PNN] - [yPT-(0.85-y)PZ] (x=0, 0.01, 0.02, 0.03, 0.05, y = 0.35, 0.40, ().425, 0.45, 0.5) were investigated. When Ti/Zr ratio was 1.0, dielectric and piezoelectric properties were highest value. With PMW 2mol%, dielectric constant, dielectric constant (d$\_$33/, d$\_$31/) and electromechanical coupling factor (kp, k$\_$31/) were highest values of 1995, 479, 186(x10$\^$-12/C/N), 0.61, 0.36, respectively. With the addition of MnO$_2$, dielectric constant, electromechanical coupling factor (kp, k$\_$31/) were decreased, but with 0.3wt% MnO$_2$, eletromechanical coupling factor was highest value of 0.63. With the addition of MnO$_2$, mechanical quality(Q$\_$m/ was increased.

  • PDF

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

Fear of dentist care and quality of life in dental health in male high school students (일부 남자 고등학생의 치과치료 공포감과 구강건강 삶의 질에 관한 연구)

  • Lee, Jung-Hwa;Lee, Yeong-Ae;Kim, Young-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.6
    • /
    • pp.951-959
    • /
    • 2014
  • Objectives: The purpose of this study was to find out the fear of dentist care, subjective recognition of dental health, and quality of life in the male high school students and to analyze the influencing factors on dental health care. Methods: A self-reported questionnaire was filled out by 243 special high-school in Deagu province from March 3 to March 14, 2014. The questionnaire consisted of general characteristics of the subjects(5 questions), subjective recognition of health and activities to improve health(6 questions), dental fear(20 questions), oral health related quality of life(16 questions). The instrument for dental fear was adapted from measured by Berggren Dental Fear Survey(DFS). A total of 20 DFS questions included treatment avoidance(8 questions), stimulus reaction(6 questions), and physiological reaction(5 questions) and score by Likert 5 scale. Cronbach alpha was 0.974 in the study. Oral health related quality of life was measured by 16 questions of CPQ11-14 for the adolescents by Lau. CPQ11-14 consisted of oral symptoms(4 questions), functional restriction(4 questions), and emotional wellbeing(4 questions). The instrument was score by Likert 5 scale and Cronbach alpha was 0.9354 in the study. Data were analyzed using SPSS 18.0 program for ANOVA and multiple regression analysis. Results: Fear of dentist care showed significant differences in treatment avoidance factor(p<0.001), stimulus reaction factor (p<0.05), and physiological reaction factor(p<0.001). The factors depended on subjective recognition of health and health-improving activities and differences in treatment avoidance factor(p<0.05) and physiological reaction factor(p<0.01). The dental symptoms factors showed significant differences in health recognition(p<0.001), interest in health(p<0.001), alcohol drinking status(p<0.001) and regular meal(p<0.001). While function limit factors showed differences in health recognition (p<0.001), interest in health(p<0.001), smoking(p<0.001), alcohol drinking(p<0.001) and regular meal(p<0.001). Mental and social stabilities factors showed significant differences in health recognition(p<0.001), interest in health(p<0.001) and alcohol drinking status(p<0.001). Among the factors influencing on the quality of life in dental health, interest in health(p<0.005), alcohol drinking(p<0.005) and physiological reaction in the midst of fear of dentist care(p<0.001) were the significant impact factor. Conclusions: It is necessary to develop a continuous and systematical program of dental health and dental care by experts so that the students can reduce the fear of dentist care by regular dental checkup and preventive treatment and care.

The Optical Tolerances' Decision of the Ophthalmic Dispensing for Korean Models (한국형 안경조제의 광학적 허용오차 설정)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.189-199
    • /
    • 1998
  • The system for optical tolerances of completion spectacles was made to sum of the accumulated error - the circumstances on composing prescription, the visual-distance, the tilting angle, the losing of a temple, the vertex distance, the axis of toric lens and the sloping of lens etc. It was given by the relation of allowed values size(T) and power(D), $T=T_0e^{-aD}$. Here, $T_0$ is the size of allowed values of plane-lens with power is 0 and ${\alpha}$ is the factor of allowed values. In case of being adopted to new form s tolerance corresponding to RAL 915, for the tolerance is large direction, the factor of allowed values ${\alpha}$ is $0.166(T_0=5.90)$ and for the tolerance is small direction, the factor of allowed values ${\alpha}$ is $0.166(T_0=2.95)$.

  • PDF

4-WEEK SUBCUTANEOUS TOXICITY STUDY OF RECOMBINANT GRANULOCYTE-MACROPHAGE COLONY STIMULATING FACTOR (LBD-005) IN RATS

  • Kim, Hyoung-Chin;Boohyon Kang;Han, Sang-Seop;Park, Jung-Koo
    • Toxicological Research
    • /
    • v.8 no.1
    • /
    • pp.49-61
    • /
    • 1992
  • Recombinant granulocyte-macrophage colony stimulating factor was subcutaneously administered to both sexes of Sprague-Dawley rats at the doses of 0, 0.5, 1 and 2mg/kg of body weight five days per week for 4 weeks to evaluate the subchronic toxicity. There were decreased 1 and 2 mg/kg. In the serum, changes were decreased alkaline phostatase(ALP) in the female groups dosed at 1 and 2mg/kg, and increased glutamic oxaloacetic transaminiase (GOT)in the male groups dosed at 0.5 and 2.0mg/kg.

  • PDF

Increased B cell-activating factor (BAFF) level in the sputum of children with asthma

  • Jee, Hye-Mi;Choi, Bong-Seok;Kim, Kyung-Won;Sohn, Myung-Hyun;Han, Man-Yong;Kim, Kyu-Earn
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.8
    • /
    • pp.795-800
    • /
    • 2010
  • Purpose: B cell-activating factor (BAFF) is a tumor-necrosis factor (TNF) superfamily member best known for its role in the survival and maturation of B cells. BAFF activity is observed in naive cells as well as in effector/memory T cells. We aimed to explore whether BAFF in sputum is expressed at elevated levels in asthmatic airways and associated with eosinophilic inflammation, pulmonary function, and bronchial hyperresponsiveness in children. Methods: One hundred and fifty-four asthmatic children and 98 healthy children were enrolled in the study. Sputum supernatants were collected and sputum BAFF and eosinophil cationic protein (ECP) levels were measured. We performed pulmonary function tests and methacholine challenge tests, while measuring total eosinophil count, total serum IgE, and serum ECP in all subjects. Results: Asthmatic children had significantly higher levels of BAFF in induced sputum [26.50 (10.50-100.27) pg/mL] compared to healthy children [18.32 (7.68-44.63) pg/mL; $P$=0.011]. Sputum BAFF positively correlated with sputum eosinophils (${\gamma}$=0.406, $P$<0.001) and sputum ECP (${\gamma}$=0.789, $P$<0.001). Significant negative correlations were found between sputum BAFF and FEV1 (${\gamma}$=-0.291, $P$<0.001) or post-bronchodilator FEV1 (${\gamma}$=-0.334, $P$<0.001), whereas nonsignificant correlations were found between sputum BAFF and bronchial hyperresponsiveness, serum eosinophil count, and serum ECP. Conclusion: These findings suggest that BAFF may play a role in childhood asthma, and BAFF levels in sputum could be a supportive marker that represents airway inflammation, especially eosinophilic inflammation.

Evaluation of multi-lane transverse reduction factor under random vehicle load

  • Yang, Xiaoyan;Gong, Jinxin;Xu, Bohan;Zhu, Jichao
    • Computers and Concrete
    • /
    • v.19 no.6
    • /
    • pp.725-736
    • /
    • 2017
  • This paper presents the two-, three-, and four-lane transverse reduction factor based on FEA method, probability theory, and the recently actual traffic flow data. A total of 72 composite girder bridges with various spans, number of lanes, loading mode, and bridge type are analyzed with time-varying static load FEA method by ANSYS, and the probability models of vehicle load effects at arbitrary-time point are developed. Based on these probability models, in accordance to the principle of the same exceeding probability, the multi-lane transverse reduction factor of these composite girder bridges and the relationship between the multi-lane transverse reduction factor and the span of bridge are determined. Finally, the multi-lane transverse reduction factor obtained is compared with those from AASHTO LRFD, BS5400, JTG D60 or Eurocode. The results show that the vehicle load effect at arbitrary-time point follows lognormal distribution. The two-, three-, and four-lane transverse reduction factors calculated by using FEA method and probability respectively range between 0.781 and 1.027, 0.616 and 0.795, 0.468 and 0.645. Furthermore, a correlation between the FEA and AASHTO LRFD, BS5400, JTG D60 or Eurocode transverse reduction factors is made for composite girder bridges. For the two-, three-, and four-lane bridge cases, the Eurocode code underestimated the FEA transverse reduction factors by 27%, 25% and 13%, respectively. This underestimation is more pronounced in short-span bridges. The AASHTO LRFD, BS5400 and JTG D60 codes overestimated the FEA transverse reduction factors. The FEA results highlight the importance of considering span length in determining the multi-lane transverse reduction factors when designing two-lane or more composite girder bridges. This paper will assist bridge engineers in quantifying the adjustment factors used in analyzing and designing multi-lane composite girder bridges.