• Title/Summary/Keyword: $V_{max}$

검색결과 894건 처리시간 0.025초

Novel Poly(p-phenylenevinylene)s Derivatives with CF3-Phenyl Substituent for Light-Emitting Diodes

  • Jin, Young-Eup;Kim, Jin-Woo;Park, Sung-Heum;Lee, Kwang-Hee;Suh, Hong-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권5호
    • /
    • pp.795-801
    • /
    • 2005
  • New PPV derivatives which contain electron-withdrawing trifluoromethyl ($CF_3$) group, poly[2-(2-ethylhexyloxy)-5-(4-trifluoro methylphenyl)-1,4-phenylenevinylene] (EH$CF_3$P-PPV), and poly[2-(2-ethylhexyloxy)-5-(3,5-bis(trifluoromethyl)-phenyl)-1,4-phenylenevinylene] (EHB$CF_3$P-PPV), have been synthesized by GILCH polymerization. As the result of the introduction of the electron-withdrawing $CF_3$ group to the phenyl substituent, the LUMO and HOMO energy levels of EH$CF_3$P-PPV (2.8, 5.1 eV) and EHB$CF_3$P-PPV (3.0, 5.3 eV) were lower than those of known poly[2-(2-ethylhexyloxy)-5-phenyl-1,4-phenylenevinylene] (EHP-PPV) (2.6, 4.9 eV). These polymers have been used as the electroluminescent (EL) layers in double layer lightemitting diodes (LEDs) (ITO/PEDOT/polymer/Al). EH$CF_3$P-PPV, and EHB$CF_3$P-PPV show maximum photoluminescence (PL) peaks at ${\lambda}_{max}$ = 550, 539 nm, and maximum EL peak at ${\lambda}_{max}$ = 545, 540 nm, respectively. The current-voltage-luminance (I-V-L) characteristics of the polymers show that turn-on voltages of EH$CF_3$P-PPV and EHB$CF_3$P-PPV are around 4.0 and 3.5 V, respectively.

EXTENSION OF BLOCK MATRIX REPRESENTATION OF THE GEOMETRIC MEAN

  • Choi, Hana;Choi, Hayoung;Kim, Sejong;Lee, Hosoo
    • 대한수학회지
    • /
    • 제57권3호
    • /
    • pp.641-653
    • /
    • 2020
  • To extend the well-known extremal characterization of the geometric mean of two n × n positive definite matrices A and B, we solve the following problem: $${\max}\{X:X=X^*,\;\(\array{A&V&X\\V&B&W\\X&W&C}\){\geq}0\}$$. We find an explicit expression of the maximum value with respect to the matrix geometric mean of Schur complements.

주기적으로 poling된 KTP 단결정을 이용한 1.57$\mu\textrm{m}$ 영역에서의 광 파라메트릭 chirped pulse 증폭

  • 이상민
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.226-227
    • /
    • 2003
  • 다양한 응용분야에서 극초단 펄스의 쓰임은 점점 증가하고 있는 추세이고, 따라서 고에너지의 극초단 펄스를 방출할 수 있는 소형화된 source 개발연구는 현재 활발히 진행되고 있다 극초단 펄스를 증폭, 보다 높은 에너지를 손쉽게 방출하기 위한 방법의 하나인 광 파라메트릭 chirped pulse amplification(OPCPA)은 처음으로 Dubietis et al.에 의해 시도되었으며, 기본원리는 피코 혹은 나노초 펄스의 고에너지를 효율적으로 시간상 stretching된 극초단 펄스로 전이하는 것이다. (중략)

  • PDF

TOPOLOGICAL CONDITIONS OF NI NEAR-RINGS

  • Dheena, P.;Jenila, C.
    • 대한수학회논문집
    • /
    • 제28권4호
    • /
    • pp.669-677
    • /
    • 2013
  • In this paper we introduce the notion of NI near-rings similar to the notion introduced in rings. We give topological properties of collection of strongly prime ideals in NI near-rings. We have shown that if N is a NI and weakly pm near-ring, then $Max(N)$ is a compact Hausdorff space. We have also shown that if N is a NI near-ring, then for every $a{\in}N$, $cl(D(a))=V(N^*(N)_a)=Supp(a)=SSpec(N){\setminus}int\;V(a)$.

PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성 (Evaluation of Average CT to Reduce the Artifact in PET/CT)

  • 김정선;남기표;박승용;류재광;차민경
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.3-7
    • /
    • 2010
  • 종양학에서 암의 진단, 병기 결정, 재발 판정, 그리고 치료에 대한 반응의 평가에 PET/CT의 유용함은 이미 인정되고 있다. 그런데 크기가 작거나 폐의 기저 부위, 혹은 간의 상부에 위치한 종양일수록 호흡으로 인한 위치 변위와 왜곡의 정도가 크며 PET영상의 SUV에도 영향을 미치게 된다. 따라서 정상 호흡 상태에서 얻어지는 PET 또는 CT영상을 토대로 방사선 치료를 하게 되면 치료해야 할 표적이 치료 범위에서 벗어나거나 정상 조직에 과도한 방사선이 조사될 수 있으므로 치료율이 낮아지거나 방사선에 의한 부작용이 증가할 수 있다. 본 논문의 목적은 호흡에 의한 인공산물을 최소화하고 보다 정확한 SUV 측정을 위해 ACT를 이용한 감쇠 보정 방법을 적용하여 그 유용성을 평가하고자 함이다. 하 흉부에 종양이 있는 13명의 환자를 대상으로 Discovery STE8 PET/CT스캐너를 사용하여 두 가지의 PET/CT영상을 얻었다. HCT를 사용한 감쇠 보정 영상과 ACT를 사용한 감쇠 보정 영상에서 측정한 인공물의 크기와 $SUV_{max}$를 비교 분석하였다. 인공물은 모든 환자의 하 흉부의 백색 음영 영역을 측정하여 평가하였다. $SUV_{max}$는 주요 종양의 $SUV_{max}$를 측정하여 평가하였다. 분석 프로그램은 Advantage Workstation v4.3을 사용하였다. 환자에게 7.4 MBq (0.2 mCi)/kg의 $^{18}F$-FDG를 투여한 1시간 뒤 스캔하였다. 방출 스캔은 3 min/bed로 스캔하였다. HCT 보정 영상과 비교하여 ACT 보정 영상에서 인공산물의 크기가 눈에 띄게 줄어든 것을 관찰할 수 있었다. 하 흉부의 저 보정으로 인한 인공산물 크기는 ACT 보정 영상과 HCT 보정 영상 각각 $1.5{\pm}3.5$ cm과 $13.4{\pm}4.2$ cm를 나타냈다. 주요 병소의 $SUV_{max}$의 변화는 ACT 보정 영상이 HCT 보정 영상보다 눈에 띄게 상승하였다. ACT 보정 영상에서 HCT영상과 비교하여 tumor의 $SUV_{max}$가 평균 $5.3{\pm}3.9%$ 상승하였다. 가장 큰 차이를 보인 종양은 lung의 lower lobe에 있는 종양으로 $SUV_{max}$ 7.7에서 $SUV_{max}$ 8.7로 13% 상승하였다. ACT를 이용한 감쇠 보정 영상은 하 흉부의 인공산물을 눈에 띄게 줄일 수 있어 보다 정확한 병소의 SUV를 측정 및 방사선 치료 범위 설정에 도움이 될 수 있을 것이다. 또한 ACT 기법은 병소가 횡격막 부근에 있는 환자의 경우 폐와 간의 경계를 보다 정확히 구분할 수 있어 판독시 도움이 될 수 있을 것이라고 판단된다. 추가 ACT 촬영에 의한 피폭 선량이 증가하는 점을 고려하여 적용한다면 임상적으로 유용한 효과가 있다고 사료된다.

  • PDF

UBVRI CCD PHOTOMETRY OF THE TYPE Ic SUPERNOVA SN 1994I IN M51: THE FIRST TWO MONTHS

  • LEE MYUNG GYOON;KIM EUNHYEUK;KIM SANG CHUL;KIM SEUNG LEE;PARK WON KEE;PYO TAE SOO
    • 천문학회지
    • /
    • 제28권1호
    • /
    • pp.31-43
    • /
    • 1995
  • We present UBVRI CCD photometry of the Type Ie supernova SN 19941 in M51 which was discovered on April 2, 1994 (UT). UBVRI CCD photometry of SN 1994 I were obtained for the period of the first two months from April 4, 1994, using the Seoul National University Observatory 60 cm telescope. The light curves of SN 19941 show several interesting features: (a) SN 19941 reaches the maximum brightness at B-band on April 8.23 (B = 13.68 mag), at V-band on April 9.10 (V = 12.89 mag), and at I-band on April 10.32 (I = 12.48 mag); (b) The light curves around the maximum brightness are much narrower than those of other types of supernovae; (c) The light curves after the peak decline more steeply than those of other types of supernovae; and (d) The colors get redder from $(V-R){\approx}0.2 mag ((V - I){\approx} 0.3 mag, (B - V){\approx}0.7 mag)$ on April 4 to $(V-R){\approx}0.6 mag ((V-1){\approx}0.9 mag, (B-V){\approx}1.3 mag)$ on April 18. Afterwards (V - R) colors get bluer slightly $(by\~0.005 mag/day)$, while (V-I) colors stay almost constant around $(V-1){\approx}1.0 mag$. The color at the maximum brightness is (B-V)=0.9 mag, which is $\~1$mag redder than the mean color of typical Type la supernovae at the maximum brightness. The light curves of SN 1994I are similar to those of the Type Ie supernova SN 1962L in NGC 1073. Adopting the distance modulus of $(m-M)_0 = 29.2 mag$ and the reddening of E(B - V) = 0.45 mag [Iwamoto et al. 1994, preprint for ApJ], we derive absolute magnitudes at the maximum brightness of SN 1994I, Mv(max) = -17.7 mag and MB(max) = -17.4 mag. This result shows that SN 1994I was $\~2$mag fainter at the maximum brightness compared with typical Type Ia supernovae. A narrower peak and faster decline after the maximum in the light curve of SN 1994I compared with other types of supernovae indicate that the progenitor of SN 1994I might be a lower mass star compared with those of other types of supernovae.

  • PDF

Aspergillus niger SFN-416으로부터 생산한 $\beta$-Glucosidase의 정제 및 특성

  • 성찬기;이상원;박석규;박정로;문일식
    • 한국미생물·생명공학회지
    • /
    • 제25권1호
    • /
    • pp.44-50
    • /
    • 1997
  • $\beta $-Glucosidase (EC 3.2.1.21) was purified from Aspergillus niger SFN-416 by a sequential process of ammonium sulfate precipitation, Sepadex G-100 and DEAE-Sephacel column chromatography. Molecular weight of the enzyme was 46, 000 daltons. The K$_{m}$ and V$_{max}$ values for PNPG were 0.67 mM and 25 moles/ml $\cdot $min., respectively. The optimum pH and temperature of the enzyme activity were 3.5 and 58$\circ $C, respectively. The enzyme activity was decreased by addition of metal ions, and increased by addition of metanol, ethanol, isopropanol and 1-butanol at a concentration of 10% (v/v). Stability of the enzyme was increased by addition of isopropanol and 1-butanol at a concentration of 10% (v/v).

  • PDF

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • 한국환경성돌연변이발암원학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF

60 GHz 무선 LAN의 응용을 위한 고이득 저잡음 증폭기에 관한 연구 (Studies on the High-gain Low Noise Amplifier for 60 GHz Wireless Local Area Network)

  • 조창식;안단;이성대;백태종;진진만;최석규;김삼동;이진구
    • 대한전자공학회논문지SD
    • /
    • 제41권11호
    • /
    • pp.21-27
    • /
    • 2004
  • 본 논문에서는 60 GHz 무선 LAN(wireless local area network) 응용을 위해 0.1 ㎛ Γ-gate pseudomorphic high electron mobility transistor(PHEMT)를 이용하여 V-band용 millimeter-wave monolithic integrated circuit(MIMIC) 저잡음 증폭기를 설계 및 제작하였다. 본 연구에서 개발한 PHEMT의 DC 특성으로 드레인 포화 전류 밀도(Idss)는 450 mA/mm, 최대 전달컨덕턴스(gm, max)는 363.6 mS/mm를 얻었으며, RF 특성으로 전류이득 차단주파수(fT)는 113 GHz, 최대 공진 주파수(fmax)는 180 GHz의 성능을 나타내었다. V-band MIMIC 저잡음 증폭기의 개발을 위해 PHEMT의 비선형 모델과 CPW 라이브러리를 구축하였으며, 이를 이용하여 V-band MIMIC 저잡음 증폭기를 설계하였다. 설계된 V-band MIMIC 저잡음 증폭기는 본 연구에서 개발된 PHEMT 기반의 MIMIC 공정을 이용해 제작되었으며, V-band MIMIC 저잡음 증폭기의 측정결과, 60 GHz에서 S21이득은 21.3 dB, 입력반사계수는 -10.6 dB 그리고 62.5 GHz에서 출력반사계수는 -29.7 dB의 특성을 나타내었다. V-band MIMIC 저잡음 증폭기의 잡음지수 측정결과, 60 GHz에서 4.23 dB의 특성을 나타내었다.