• Title/Summary/Keyword: $V_{}$ max/

Search Result 894, Processing Time 0.032 seconds

Assessment of Dose Distributions According to Low Magnetic Field Effect for Prostate SABR

  • Son, Jaeman;An, Hyun Joon;Choi, Chang Heon;Chie, Eui Kyu;Kim, Jin Ho;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.26-31
    • /
    • 2019
  • Background: Stereotactic ablative radiotherapy (SABR) plans in prostate cancer are compared and analyzed to investigate the low magnetic effect (0.35 T) on the dose distribution, with various dosimetric parameters according to low magnetic field. Materials and Methods: Twenty patients who received a 36.25 Gy in five fractions using the MR-IGRT system (ViewRay) were studied. For planning target volume (PTV), the point mean dose ($D_{mean}$), maximum dose ($D_{max}$), minimum dose ($D_{min}$) and volumes receiving 100% ($V_{100%}$), 95% ($V_{95%}$), and 90% ($V_{90%}$) of the total dose. For organs-at-risk (OARs), the differences compared using $D_{max}$, $V_{50%}$, $V_{80%}$, $V_{90%}$, and $V_{100%}$ of the rectum; $D_{max}$, $V_{50%}$, $V_{30Gy}$, $V_{100%}$ of the bladder; and $V_{30Gy}$ of both left and right femoral heads. For both the outer and inner shells near the skin, $D_{mean}$, $D_{min}$, and $D_{max}$ were compared. Results and Discussion: In PTV analysis, the maximum difference in volumes ($V_{100%}$, $V_{95%}$, and $V_{90%}$) according to low magnetic field was $0.54{\pm}0.63%$ in $V_{100%}$. For OAR, there was no significant difference of dose distribution on account of the low magnetic field. In results of the shells, although there were no noticeable differences in dose distribution, the average difference of dose distribution for the outer shell was $1.28{\pm}1.08Gy$ for $D_{max}$. Conclusion: In the PTV and OARs for prostate cancer, there are no statistically-significant differences between the plan calculated with and without a magnetic field. However, we confirm that the dose distribution significantly increases near the body shell when a magnetic field is applied.

STRUCTURE OF THE SPIRAL GALAXY NGC 300 -1. The generalzation of Toomre's mass model-

  • Rhee, Myung-Hyun;Chun, Mun-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • v.9 no.1
    • /
    • pp.11-29
    • /
    • 1992
  • In 1963, Toomre built up classes of mass models for the highly flattened galaxies which have free parameters n, $a_n$ and $C_n$. In order to keep the universal dimension, we adopt parameters $b_n({C_n}^2={a_n}^{2n}+^2{b_n}^2/(n-1)!)$ insteal of $C_n$. Series of the normalized Toomre's mass models (G = $V_{max}$ =$R_{max}$ = 1, n = 1 to 7) are derived and the normalized parameters $a_n$ and $b_n$ are determined by the iteration method. Replacing parameters $a_n$ and $b_n$ to ${a_n}^l(=a_nr_{max})$ and ${b_n}^l(=b_n\cdotV_{max}/r_{max})$, we can get the generalization of Toomre's mass model.

  • PDF

Rat Intestinal α-Glucosidase Inhibitory Activities of Leguminous Seed Extracts

  • Kim, Min-Jeong;Ahn, Young-Joon;Kim, Moo-Key;Kim, Hye-Young;Lee, Hoi-Seon
    • Journal of Applied Biological Chemistry
    • /
    • v.44 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • The methanol extracts of 25 leguminous seeds in vitro was evaluated for inhibitory activities against the small intestinal $\alpha$-glucosidase of Sprague Dawley male rats. The responses varied both with leguminous seed types and concentrations used. At the concentration of 0.5 mg/ml, the methanol extracts of Cassia obtusifolia, Glycine max var. yagkong, Glycine max var. hooktae, Glycine max var. geumdu, Glycine max var. mejukong, Glycine soja, Phaseolus multiflorus, Pisum sativum, and Vigna sinensis inhibited over 50% of the enzyme activity. The extracts of G. max var. yagkong and V. sinensis showed relatively strong inhibitory activities against $\alpha$-glucosidase at the concentration of 0.1 mg/ml. The activity of each solvent fraction from G. max var. yagkong and V. sinensis was determined, and potent activities were detected from chloroform and butanol fractions, respectively. $IC_{50}$ values of G. max var. yagkong and V. sinensis were 0.06 and 0.19 mg/ml, respectively. As a naturally occurring therapeutic agents, leguminous seeds examined could be useful for developing new types of antidiabetic agents.

  • PDF

HPLC Method for the Determination of Nicorandil in Human Plasma

  • Park, Sun-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.16 no.2
    • /
    • pp.168-172
    • /
    • 2008
  • The present study is to determine of sensitive nicorandil analysis method using HPLC and measure the pharmacokinetics parameters (bioavailability, $C_{max}$, $T_{max}$, Ke, $T_{1/2}$) of nicorandil (5 mg, Tab; Choongwae Pharma Corporation). Plasma (500 ul) was mixed with furosemide (internal standard, 500 ug/ml). Detection wavelength was 256 nm. The mixture of 0.01 M ammonium acetate and acetonitrile 80:20 (v/v) was used mobile phase. The HPLC separation was accomplished on ODC reverse HPLC column. The nicorandil was analyzed by a HPLC system, which consists of CAPCELL PAK C18 column (5 ${\mu}$m, 4.6 × 150 mm) and a chromatography data analysis S/W, using a isocratic mobile phase (mixture of 0.01 M ammonium acetate and acetonitrile 80:20 ) at 1.0 ml/min. Its sensitivity, selectivity, accuracy and precision must be adequate for the bioavailabilty study of nicorandil, and the linearity ($r^2$ ≥ 0.9994) of nicorandil was also proved in the range of 0.05 ug/ml . 3 ug/ml. The pharmacokinetic parameters of nicorandil (5 mg) tablets were measured as the follow. AUC: 0.19 ug/ml·hr, $C_{max}$: 0.14 ug/ml, $t_{max}$: 0.58 hr, Ke: 0.11 hr., $t_{1/2\beta}$: 6.76 hrs. This method is simple and sensitive HPLC method using UV detector for determination of nicorandil in human plasma.

A Study on the Revolution Characteristics of the Ultrasonic Motor with Windmill Type Structure (풍차형 구조를 갖는 초음파 전동기의 회전 특성에 관한 연구)

  • Kim, Jin-Su;Lee, Deok-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.681-686
    • /
    • 1999
  • In this study, a windmill type ultrasonic motor operated by single-phase AC electric field was fabricated, and then revolution characteristics and 3-dimensional vibration mode of the ultrasonic motor were investigated. Brass metal was pressed with umbrella-type using metal mold, then slot of 4 kind was processed at various thickness. It was found that the revolution speed of the ultrasonic motor increased with decreasing the thickness of elastic body. The revolution speed of the ultrasonic motor increased with increasing the slots of elastic body. When the characteristics was measured, applied voltage was changed from $10V_{max}\; to\; 100V_{max}$. Then, revolution was began from $30V_{max}$, if voltage was applied over $90V_{max}$ revolution speed was saturated, and not increased. The maximum revolution speed was 510[rpm] when using elastic body with 6 slots and thickness of 0.15mm. And 3-dimensional displacement mode was rotated clockwise direction.

  • PDF

In vitro Metabolism of Pentoxifylline Metabolite M-l in Human Liver Microsomes (인체 간 microsome에서 pentoxifylline 대사체 M-1의 시험관내 대사)

  • 신혜순
    • YAKHAK HOEJI
    • /
    • v.43 no.6
    • /
    • pp.834-842
    • /
    • 1999
  • The metabolism and pharmacokinetics of M-l, which is metabolite of pentoxifylline, have been studied in human liver microsomes. Biphasic kinetics was observed from the Eadie-Hofstee plot for the formation of both metabolites of M-l. For the kinetics of pentoxifylline, mean values of $V_{max1}{\;}and{\;}V_{max2}$ were 1,648 and 5,622 nmol/min/mg protein, and the estimated values of $K_{ml}{\;}and{\;}K_{m2}$ were 0.180 and 4.829 mM, respectively. For M-3, mean values of $V_{max1}{\;}and{\;}V_{max2}$ were 0.062 and 0.491 nmol/min/mg protein, and estimated values of $K_{ml}{\;}and{\;}K_{m2}$ were 0.025 and 1.216 mM. The formations of pentoxifylline and M-3 from M-1 were indentified by using several selective inhibitors of cytochrome P450 isoformes at 0.05-5 mM concentration of M-1 in human liver microsomes. For the analysis of low (0.05 mM) concentration of M-1, where the affinity was expected as low, indicated that CYPlA2 and CYP3A4 were major P450 isoforms responsible for pentoxifylline and M-3 formation. CYP3A4 and CYP2A6 appeared to be P450 isoforms responsible for M-3 formation at high (5 mM) concentration of M-1.

  • PDF

The Design of Auxiliary Power Supplies for 30kW, 95GHz Gyrotron (30kW, 95 GHz 자이로트론 구동을 위한 보조 전원장치 설계)

  • Seo, Jung-Ho;Jang, Sung-Roc;Ahn, Suk-Ho;Kim, Jong-Soo;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.347-348
    • /
    • 2015
  • 본 논문은 30kW, 95GHz 자이로트론 구동을 위한 $25kV_{max}$, $10mA_{max}$ 출력 사양의 Body Power Supply (BPS)와 $10V_{max}$, $10A_{max}$ 사양을 가지며 50kV 절연이 요구되는 Heater Power Supply (HPS)의 설계에 관하여 기술한다. 자이로트론 구동 효율 향상에 필요한 BPS는 높은 승압비 달성 및 절연에 대한 신뢰성 확보를 위해 8개의 분리된 코어를 사용하여 변압기를 구성하고, 각 코어간의 보상권선을 이용하는 방식을 제안하여 직렬로 구성된 8개의 고전압 정류부 간의 전압 불균형 문제를 해결 한다. HPS는 50kV 전위가 인가되는 코일 가열을 위해 사용되는 전원으로 내부 고주파 변압기를 이용하여 효율적인 절연 설계를 구현한다. 30kW, 95GHz 자이로트론 구동 시스템의 신뢰성 확보와 전원장치의 높은 전력밀도 달성을 위해 두 전원장치는 공진형 컨버터 토폴로지를 기반으로 설계하고, 시뮬레이션 및 실험을 통해 개발된 전원의 우수성을 검증한다.

  • PDF

Effects of red ginseng supplementation on aerobic.anaerobic performance, central and peripheral fatigue (홍삼 섭취가 유.무산소성 운동수행능력과 중추 및 말초피로에 미치는 영향)

  • Yoon, Sung-Jin;Kim, Ki-Hyung;Kim, Chang-Ju;Park, Hae-Chan;Kang, Kyung-Hee;Kim, Moo-Jung;Kang, Sung-Mok;Kwak, Uk-Heon;Kim, Hyung-Joon
    • Journal of Ginseng Research
    • /
    • v.32 no.3
    • /
    • pp.210-219
    • /
    • 2008
  • The purpose of this study is to examine the effect of red ginseng on the performance of aerobics anaerobics exercise and peripheral central fatigue. For this purpose, we measured $\dot{V}O_2max$, $\dot{V}O_2$ at recovery, anaerobic power, blood lactate, Branched-Chain Amino Acid(BCAA) etc in thirty male subjects. They were divided into three group; EGG: endurance training + red ginseng supplementation group(n=7), EPG: endurance training + placebo supplementation group(n=7), GG: only red ginseng supplementation group(n=10). 6 subjects were excepted because they were intermediate test absence(test at four week : EGG=1, EPG=2; test at eight week : EGG=1). EGG and GG took red ginseng twice a day for total 8weeks. Moreover, EGG and EPG were exercised during 45 minutes, three times a week for 12 weeks. The result of this study are shown as follow: In case of $\dot{V}O_2max$, %$\dot{V}O_2$/$\dot{V}O_2max$ and plasma BCAA concentration, no statistically significant change were found among three groups. But, it was showed that three groups tended to increased slightly in $\dot{V}O_2max$, % $\dot{V}O_2$/$\dot{V}O_2max$ and plasma BCAA concentration. For conclusion, the present data provide a new evidence that ingestion of ergogenic aids contained with red ginseng may improve aerobic exercise performance and central fatigue.

Electron Emission Properties of Hetero-Junction Structured Carbon Nanotube Microtips Coated With BN And CN Thin Films (탄소 나노튜브 위에 붕소 및 탄소 질화 박막이 코팅된 이종접합 구조 미세팁의 전자방출 특성)

  • Noh, Young-Rok;Kim, Jong-Pil;Park, Jin-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.743-748
    • /
    • 2010
  • Boron nitride (BN) and carbon nitride (CN) films, which have relatively low work functions and commonly exhibit negative electron affinity behaviors, were coated on carbon nanotubes (CNTs) by magnetron sputtering. The CNTs were directly grown on metal-tip (tungsten, approximately 500nm in diameter at the summit part) substrates by inductively coupled plasma-chemical vapor deposition (ICP-CVD). The variations in the morphology and microstructure of CNTs due to coating of the BN and CN films were analyzed by field-emission scanning electron microscopy (FE-SEM). The energy dispersive x-ray (EDX) spectroscopy and Raman spectroscopy were used to identify the existence of the coated layers (CN and BN) on CNTs. The electron-emission properties of the BN-coated and CN-coated CNT-emitters were characterized using a high-vacuum field emission measurement system, in terms of their maximum emission currents ($I_{max}$) at 1kV and turn-on voltage ($V_{on}$) for approaching $1{\mu}A$. The results showed that the $I_{max}$ current was significantly increased and the $V_{on}$ voltage were remarkably reduced by the coating of CN or BN films. The measured values of $I_{max}-V_{on}$ were as follows; $176{\mu}A$-500V for the 5nm CN-coated emitter and $289{\mu}A$-540V for the 2nm BN-coated emitter, respectively, while the $I_{max}-V_{on}$ of the as-grown (i.e., uncoated) emitter was $134{\mu}A$-620V. In addition, the CNT emitters coated with thin CN or BN films also showed much better long-term (up to 25h) stability behaviors in electron emission, as compared with the conventional CNT emitter.

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF