• Title/Summary/Keyword: $T4K^{TM}$

Search Result 158, Processing Time 0.029 seconds

Electro-optic Properties and Thermal Stabilities of Polyimide-DRI Side Chain Polymer for Photonic Devices (폴리이미드-DR1 옆사슬계 전기광학 고분자의 전기광학 특성 및 열적 안정성)

  • Lee, Myeong-Hyeon;Lee, Hyeong-Jong;O, Min-Cheol;An, Ju-Heon;Han, Seon-Gyu
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.355-361
    • /
    • 1999
  • We have synthesized the soluble polymide based side chain system with covalently attached NLO chromophore Disperse Red 1. The developed polymer is optically transparent in the range of optical communication wave-lengths. Its glass transition temperature$(T_g)$ and thermal decomposition temperature$(T_d)$ are $225^{\circ}C, 310^{\circ}C$ respectively. The poled film with the poling field of $100 V/\mu\textrm{m}$ shows that the dielectric constant is 3.37 at the 10-kHz frequency, the refractive indices of TM and TE modes are both 1.631 at $\lambda = 1300 nm$, and the Electro-optic coefficients are 4.6~9.2 pm/V at $\lambda = 1300 nm$. There are no decays of the EO coefficient in the poled polymer at $180^{\circ}C$ in one hour, and $90^{\circ}C$ in 500 hours.

  • PDF

Multivessel Coronary Revascularization with Composite LITA-RA Y Graft (좌내흉동맥-요골동맥 복합이식편을 이용한 다중혈관 관상동맥우회술)

  • Lee Sub;Ko Mgo-Sung;Park Ki-Sung;Ryu Jae-Kean;Jang Jae-Suk;Kwon Oh-Choon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.359-365
    • /
    • 2006
  • Background: Arterial grafts have been used to achieve better long-term results for coronary revascularization. Bilateral internal thoracic artery (ITA) grafts have a better results, but it may be not used in some situations such as diabetes and chronic obstructive pulmonary disease (COPD). We evaluated the clinical and angiographic results of composite left internal thoracic artery-radial artery (LITA-RA) Y graft. Material and Method: Between April 2002 and September 2004, 119 patients were enrolled in composite Y graft for coronary bypass surgery. The mean age was $62.6{\pm}8.8$ years old and female was 34.5%. Preoperative cardiac risk factors were as follows: hypertension 43.7%, diabetes 33.6%, smoker 41.2%, and hyperlipidemia 22.7%, There were emergency operation (14), cardiogenic shock (6), left ventricle ejection fraction (LVEF) less than 40% (17), and 17 cases of left main disease. Coronary angiography was done in 35 patients before the hospital discharge. Result: The number of distal anastomoses was $3.1{\pm}0.91$ and three patients (2.52%) died during hospital stay. The off-pump coronary artery bypass (OPCAB) was applied to 79 patients (66.4%). The LITA was anastomosed to left anterior descending system except three cases which was to lateral wall. The radial Y grafts were anastomosed to diagonal branches (4), ramus intermedius (21), obtuse marginal branches (109), posterolateral branches (12), and posterior descending coronary artery (8). Postoperative coronary angiography in 35 patients showed excellent patency rates (LITA 100%, and RA 88.5%; 3 RA grafts which anastomosed to coronary arteries <70% stenosed showed string sign with competitive flow). Conclusion: The LITA-RA Y composite graft provided good early clinical and angiographic results in multivessel coronary revascularization. But it should be cautiously used in selected patients.

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

IoT Service Design Framework Using BLE Sensor Node (저전력 센서 노드를 사용한 IoT 서비스 설계 프레임워크)

  • Kim, jung-sook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.37-38
    • /
    • 2015
  • 최근 안드로이드 4.0 이상 버전에서 저전력 블루투스(Bluetooth Low Energy) 기능이 지원되면서, 다양한 응용사례가 나타나고 있다. 이러한 BLE 프로토콜을 활용하는 Sensor-Tag IoT 센서노드를 활용하면 스마트홈, 웨어러블, 스마트카, 생활밀착 서비스, 스마트에너지, 산업 및 환경분야에서 다양한 스마트폰 앱을 개발할 수 있다. 또한, BLE-스택(Stack)TM 소프트웨어를 사용하면, 라이센서 걱정없이 펌웨어 소스코드의 개발 및 업데이트가 가능하다. 따라서, 다양한 센서가 장착된 IoT Sensor 노드를 통하여, 습도/온도/가속도/지자기/자이로 등의 데이터를 수집하여 활용할 수 있다. 이에 본 논문에서는 "저전력 센서 노드를 사용한 IoT 서비스 설계 프레임워크"를 제안한다.

  • PDF

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

ON THE COMMUTANT OF MULTIPLICATION OPERATORS WITH ANALYTIC POLYNOMIAL SYMBOLS

  • Robati, B. Khani
    • Bulletin of the Korean Mathematical Society
    • /
    • v.44 no.4
    • /
    • pp.683-689
    • /
    • 2007
  • Let $\mathcal{B}$ be a certain Banach space consisting of analytic functions defined on a bounded domain G in the complex plane. Let ${\varphi}$ be an analytic polynomial or a rational function and let $M_{\varphi}$ denote the operator of multiplication by ${\varphi}$. Under certain condition on ${\varphi}$ and G, we characterize the commutant of $M_{\varphi}$ that is the set of all bounded operators T such that $TM_{\varphi}=M_{\varphi}T$. We show that $T=M_{\Psi}$, for some function ${\Psi}$ in $\mathcal{B}$.

DNA Polymorphism in SLC11A1 Gene and its Association with Brucellosis Resistance in Indian Zebu (Bos indicus) and Crossbred (Bos indicus×Bos taurus) Cattle

  • Kumar, Nishant;Ganguly, Indrajit;Singh, Rajendra;Deb, Sitangsu M.;Kumar, Subodh;Sharma, Arjava;Mitra, Abhijit
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.7
    • /
    • pp.898-904
    • /
    • 2011
  • The PCR- restriction fragment length polymorphism (RFLP) in and around TM4 of SLC11A1 gene and its association with the incidences of brucellosis in Hariana breed (Bos indicus) and Holstein Friesian crossbred (Bos indicus${\times}$Bos taurus) cattle was examined. A fragment of 954 bp encoding the TM4 was amplified, and RFLP was identified by digestion of the amplicon independently with AluI and TaqI. The amplicon (GenBank Acc. No. AY338470 and AY338471) comprised of a part of exon V (<59 bp) and VII (62>), and entire intron 5 (423 bp), exon VI (71 bp) and intron 6 (339 bp). Digestion with AluI revealed the presence of two alleles viz, A (281, 255, 79 and 51 bp) and B (541, 255, 79 and 51 bp). The frequency of A allele was estimated as 0.80 and 0.73 in Hariana and crossbred cattle, respectively. Due to presence of a polymorphic TaqI site at intron 5, two alleles: T (552 and 402 bp) and Q (231, 321 and 402 bp) were identified. The frequency of T allele was estimated as 0.96 and 0.97, respectively. For association study, on the basis of serological tests and history of abortion, the animals were grouped into "affected" and "non-affected". However, no association could be established with the observed RFLPs.

Measurement of hard tissue density of head phantom based on the HU by using CBCT (콘빔형 전산화단층영상에서 HU에 의한 두경부 팬텀 경조직의 밀도 측정)

  • Kim, Moon-Sun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose : The purpose of this study was to determine a conversion coefficient for Hounsfield Units(HU) to material density ($g\;cm^{-3}$) obtained from cone-beam computed tomography ($CBMercuRay^{TM}$) data and to measure the hard tissue density based on the Hounsfield scale on dental head phantom. Materials and Methods : CT Scanner Phantom (AAPM) equipped with CT Number Insert consists of five cylindrical pins of materials with different densities and teflon ring was scanned by using the $CBMercuRay^{TM}$ (Hitachi, Tokyo, Japan) volume scanner. The raw data were converted into DICOM format and the HU of different areas of CT number insert measured by using $CBWorks^{TM}$. Linear regression analysis and Student t-test were performed statistically. Results : There was no significant difference (P > 0.54) between real densities and measured densities. A linear regression was performed using the density, $\rho$($g\;cm^{-3}$), as the dependent variable in terms of the HU (H). The regression equation obtained was $\rho=0.00072H-0.01588$ with an $R^2$ value of 0.9968. Density values based on the Hounsfield scale was $1697.1{\pm}24.9\;HU$ in cortical bone, $526.5{\pm}44.4\;HU$ in trabecular bone, $2639.1{\pm}48.7\;HU$ in enamel, $1246.1{\pm}39.4\;HU$ in dentin of dental head phantom. Conclusion : CBCT provides an effective option for determination of material density expressed as Hounsfield Units.

  • PDF

Bioavailability Test of TestoTM Tablets (Methyltestosterone, 25 mg) in Male Healthy Volunteers by a Gas-chromatography/Mass Selective Detector

  • Kwon, Oh-Seung;Kim, Hye-Jung;Pyo, Hee-Soo;Kim, Dae-Duk;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.383-388
    • /
    • 2005
  • A simple and specific method for determination of methyltestosterone (MT) has been established by a gas chromatography/mass selective detector and applied in plasma of healthy male volunteers received a single oral dose of 50 mg MT $(Testo^{TM}\;tablets,\;25\;mg)$ for bioavailability test. This method involves using liquid-liquid extraction of the sample with diethyl ether and derivatization with MSTFA. MT showed good resolution in this condition. The detection limit of quantitation was 5 ng/ml. A good linearity (r>0.996) was obtained at the range of 5-250 ng/ml of MT. Intra-day precision and accuracy were 2.76-12.56% and 0.39-8.01 %, and inter-day precision and accuracy were 2.29-17.69% and 0.42-7.99%, respectively. The established method was applied on bioavailability test of MT in human volunteers. The value of $AUC_{0\;to\;last}$ to last was $264.5{\pm}123.9\;ng{\cdot}hr/ml$ and that of $AUC_{0\;to\;inf}$ was determined to be $275.2{\pm}126.5\;ng{\cdot}hr/ml$. The values of $C_{max}$ and $T_{max}$ were $95.9{\pm}67.1\;ng/ml$ and $1.13{\pm}0.9\;hr$, respectively. The mean elimination half-life $(t_{1/2})$ was $4.4{\pm}0.9\;hr$. This analytical method is suitable and useful for the pharmacokinetics and bioequivalence studies of MT.

The Impact of Environmental Characteristics in the Geumho River Watershed on Stream Water Quality (금호강 유역의 환경특성이 하천수질에 미치는 영향)

  • Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.4
    • /
    • pp.85-98
    • /
    • 2003
  • There has recently been an increasing interest of the watershed management as a solution to a wide range of problems related water environment, therefore this study attempted to construct the environment information system to monitor the Geumho River watershed, and to evaluate the impacts of the watershed characteristics on stream water quality. A detailed GIS database to analyze the environmental characteristics at the subwatershed units, including 1:25,000 scale topographical maps, detailed soil maps, land use, 10m-resolution DEMs, roads, streams, vegetation index(NDVI) calculated from Landsat TM imagery, rainfall, and soil loss using RUSLE, is compiled for the study area. The set of variables representing watershed urbanization or industrialization, residential and commercial landuse, industrial landuse, and road area have significantly negative(-) relationship with water quality variables(BOD, COD, SS, T-N, T-P). On the other hand, watershed indicators related to natural environmental conditions, forest cover and vegetation index(NDVI) in each subwatershed were significantly positive(+) relationship with water quality. Three other variables, agricultural landuse, amount of fertilizer and pesticides, and potential soil loss, were not significant in explaining the correlations between watershed environment and stream water quality.

  • PDF