• 제목/요약/키워드: $T2^*$ weighted

검색결과 728건 처리시간 0.024초

림프절의 자기공명영상의 특징: 가토에서 T1과 T2 강조영상의 비교 (Magnetic resonance imaging characteristic of lymph nodes: Comparison of T1 and T2 weighted image in normal rabbits)

  • 이기창;최민철;최호정;윤정희;최승홍;문우경;정진욱
    • 대한수의학회지
    • /
    • 제44권2호
    • /
    • pp.311-315
    • /
    • 2004
  • The detection of lymph node metastasis is an important step in tumor staging and is significant for therapy planning. It has been challenged to yield an appropriate image with diagnostic methods such as Magnetic Resonance (MR) and Computed Tomography (CT). Though CT has been used widely and accessed easily to show internal organs, it can hardly provide difference between lymph node and adjacent vessel or fat tissue. It has been well established that MR can reveal the subtle discrepancy within soft tissue. This study investigated the suitability of MR lymph node imaging without contrast enhancement by comparison of T1-weighted image (T1WI) and T2- weighted image (T2WI) in ten normal rabbits. According to the pulse sequence optimized from preliminary study, T1-weighted spin-echo (repetition time/echo time=400/12 ms) and T-2 weighted fast spin-echo (repetition time/echo time=3500/84 ms) images covering the hind limbs and pelvic region were acquired at 1.5 T. Two radiologists scrupulously evaluated the MR images in consensus. And signal intensity of lymph nodes was compared with that of adjacent fat. Statistical analysis showed that T1-weighted coronal image visualized the lymph nodes (iliac, superficial inguinal and popliteal lymph nodes) quickly and consistently rather than T2-weighted one. Conclusively, T1WI for evaluation of lymph nodes is moderately better than T2WI and appears to have potential for quick and sufficient mapping of the lymph nodes. In addition, this normal MR image of lymph nodes could be applied to further study for the evaluation of lymphatic system in abscess and tumor bearing animal model.

Magnetic Resonance Imaging Evaluation of the Prostate in Normal Dogs

  • Cho, Yu-Gyeong;Choi, Ho-jung;Lee, Ki-ja;Lee, Youngwon
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.317-323
    • /
    • 2020
  • The aims of this study were to describe the appearance and size of the normal canine prostate using magnetic resonance (MR) imaging and to calculate the apparent diffusion coefficient (ADC) values. MR images were obtained from seven intact male beagle dogs using a 1.5 T MR unit. The sequences included pre- and post-contrast T1- and T2-weighted imaging with and without fat saturation. The signal intensity of the prostate was compared with the adjacent musculature, fat, and urine in the urinary bladder. We recorded the mean prostatic length, width, and height and the length of the sixth lumbar vertebral body (L6). In addition, the prostatic length (rL), width (rW), and height (rH) ratios to L6 were calculated. Diffusion-weighted images of the prostate were obtained and ADC values were calculated. The prostate was bilobed and oval-shaped, homogenous on T1-weighted images, and heterogeneous with radiating lines on T2-weighted images. Post-contrast T1-weighted sequences showed contrast enhancement of the central and radiating striations. The prostatic capsule was clearly identified on post-contrast T1-weighted images with fat saturation. The ADC values were 1.72-2.04 × 10-3mm2/sec (mean, 1.88 × 10-3mm2/sec). Knowledge of the normal appearance of the prostate on MR images is essential to assess prostatic diseases in dogs.

Studies on the Ability to Detect Lesions According to the Changes in the MR Diffusion Weighted Images

  • Kim, Chang-Bok;Cho, Jae-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.153-157
    • /
    • 2012
  • This study evaluated the ability of Diffusion-Weight Image (DWI), which is one of pulse sequences used in MRI based on the T2 weighted images, to detect samples placed within phantoms according to their size. Two identically sized phantoms, which could be inserted into the breast coil bilaterally, were prepared. Five samples with different sizes were placed in the phantoms, and the T2 weighted images and DWI were obtained. The Breast 2 channel coil of SIEMENS MAGNETOM Avanto 1.5 Tesla equipment was used for the experiments. 2D T2 weighted images were obtained using the following parameters: TR/TE = 6700/74 msec, Thickness/gap = 5/1 mm, Inversion Time (TI) = 130 ms, and matrix = $224{\times}448$. The parameters of DWI were that TR/TE = 8100/90 msec, Thickness/gap = 5/1 mm, matrix = $128{\times}128$, Inversion Time = 185 ms, and b-value = 0, 100, 300, 600, 1000 s/mm. The ratio of the sample volume on DWI compared to the T2 weighted images, which show excellent ability to detect lesions on MR images, was presented as the mean b-value. The measured b-value of the samples was obtained: 0.5${\times}$0.5 cm=0.33/0.34 square ${\times}$ cm (103%), 1${\times}$1 cm=1.28/1.25 square ${\times}$ cm (102.4%), 1.5${\times}$1.5 cm = 2.28/2.67 square ${\times}$ cm (85.39%), 2${\times}$2 cm=3.56/4.08 square ${\times}$ cm (87.25%), and 2.5${\times}$2.5 cm=7.53/8.77 square ${\times}$ cm (85.86%). In conclusion, the detection ability by the size of a sample was measured to be over 85% compared to T2 weighted image, but the detection ability of DWI was relatively lower than that of T2 weighted image.

Subnormality and Weighted Composition Operators on L2 Spaces

  • AZIMI, MOHAMMAD REZA
    • Kyungpook Mathematical Journal
    • /
    • 제55권2호
    • /
    • pp.345-353
    • /
    • 2015
  • Subnormality of bounded weighted composition operators on $L^2({\Sigma})$ of the form $Wf=uf{\circ}T$, where T is a nonsingular measurable transformation on the underlying space X of a ${\sigma}$-finite measure space (X, ${\Sigma}$, ${\mu}$) and u is a weight function on X; is studied. The standard moment sequence characterizations of subnormality of weighted composition operators are given. It is shown that weighted composition operators are subnormal if and only if $\{J_n(x)\}^{+{\infty}}_{n=0}$ is a moment sequence for almost every $x{{\in}}X$, where $J_n=h_nE_n({\mid}u{\mid}^2){\circ}T^{-n}$, $h_n=d{\mu}{\circ}T^{-n}/d{\mu}$ and $E_n$ is the conditional expectation operator with respect to $T^{-n}{\Sigma}$.

고속스핀에코기법을 이용한 MRI검사에서 ETL 변화에 따른 영상 blurring의 평가 (Evaluation of the Image Blurring in the Fast Spin Echo Technique ccording to Variation of the ETL)

  • 권순용;임우택;강충환;김경수;김순배;김현수
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.55-61
    • /
    • 2013
  • The purpose of this study is to evaluate image blurring according to variation of the ETL and propose the clinically appropriate ETL range. SIEMENS MAGNETOM Skyra 3.0T and 20 channel head coil were used for the study. MRI phantom was kept the lines horizontally to three direction(X,Y,Z) of the coil and T1, T2 weighted images that used the fast spin echo technique acquired. The ETL with increase of 10 was applied from 10 to 80. In addition, the ETL with increase of 1 was applied in the interval statistically significant differences occurred. And T1, T2 weighted images that used the conventional spin echo technique acquired to compare image blurring of the images that used the fast spin echo technique. The slope of lattice in the images was measured using Image J 1.47v program to evaluate image blurring. And image blurring was determined by the degree of the slope. The statistical significance of both techniques was evaluated by the Kruskal-Wallis test of the SPSS 17.0v. And the correlation of the ETL and image blurring was evaluated quantitatively by regression analysis. The slope of the T1, T2 weighted images that used fast spin echo technique decreased as contrasted with conventional spin echo technique. In the result of the Kruskal-Wallis test, the T1, T2 weighted images that used fast spin echo technique made a significant difference with conventional spin echo technique. Particularly, in the Tomhane' T2 test, the T1, T2 weighted images made a significant difference from ETL 22 and 31 respectively. In the result of the regression analysis, the R-squared of the T1, T2 weighted images are 0.762 and 0.793. It is difficult to apply the long ETL in the T1 weighted image caused by the short TR and multi-slices study. Therefore, clinical impact according to variation of the ETL is very slight in the T1 weighted images. But the application of the proper ETL is demanded in T2 weighted images using the fast spin echo technique in order to prevent image blurring.

  • PDF

T1, T2강조영상, FLAIR영상의 임상 적용 (T1-, T2-weighted, and FLAIR Imaging: Clinical Application)

  • 김재형
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2009
  • T1, T2강조영상, FLAIR (fluid attenuated inversion recovery) 영상기법은 뇌 MRI의 가장 기본적인 영상기법들이다. T1강조영상은 짧은 TR과 짧은 TE를 이용한 스핀에코 기법으로서 조직의 T1이완시간의 차이를 신호 차이로 반영하는 기법이다. 짧은 TR을 사용하면 조직 간에 종축 자기화의 회복 정도가 크게 차이나게 되며 이를 신호에 반영하는 것이다. T2강조영상은 긴 TR과 긴 TE를 이용한 스핀에코 기법으로서 조직의 T2이완시간의 차이를 신호 차이로 반영하는 기법이다. 긴 TE을 사용하면 조직 간에 횡축 자기화의 붕괴가 크게 차이나게 되며 이를 신호에 반영하는 것이다. FLAIR는 180도 반전펄스를 먼저 가하는 반전회복 (inversion recovery) 기법의 일종으로서 뇌척수액의 신호를 억제하기 위하여 2500 msec 정도의 반전시간을 적용한다.

  • PDF

Characterization of focal hepatic lesions with ferucarbotran (Resovist)-enhanced T2 and T2*-weighted MR imaging

  • 조은석;유정식
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.40-40
    • /
    • 2003
  • The purpose of this study was to characterize focal hepatic lesions through pre and post ferucarbotran-enhanced T2 and T2*-weighted imaging and to help differentiate benign and malignant lesions 대상 및 방법: Consecutive 34 patients with 52 hepatic lesions underwent MRI before and after intravenous bolus injection of ferucarbotran (Resovist Sobering, Berlin, Germany) for evaluation of focal hepatic lesions. Lesions included hemangiomas (n=17), metastases (n=12), cysts (n=10), hepatocellular carcinomas (n=8), dysplastic nodules (n=4), and focal fat deposit (n=1). T2-weighted fast spin echo (TR/TE: 4060/138) and gradient echo T2*-weighted images(TR/TE: 140/5.3, FA = 90) were obtained according to the institutional routine imaging protocol. Lesional signal-intensity and lesion-to-liver contrast changes were measured by contrast-to-noise ratio (CNR) from region of interest.

  • PDF

Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

  • Laurino, Fernando Antonio Reis;Choi, Isabela Goulart Gil;Kim, Jun Ho;Gialain, Ivan Onone;Ferraco, Renato;Haetinger, Rainer Guilherme;Pinhata-Baptista, Otavio Henrique;Abdala-Junior, Reinaldo;Costa, Claudio;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.93-98
    • /
    • 2020
  • Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Micro-computed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

SOME INEQUALITIES OF WEIGHTED SHIFTS ASSOCIATED BY DIRECTED TREES WITH ONE BRANCHING POINT

  • KIM, BO GEON;SEO, MINJUNG
    • East Asian mathematical journal
    • /
    • 제31권5호
    • /
    • pp.695-706
    • /
    • 2015
  • Let ${\mathcal{H}}$ be an infinite dimensional complex Hilbert space, and let $B({\mathcal{H}})$ be the algebra of all bounded linear operators on ${\mathcal{H}}$. Recall that an operator $T{\in}B({\mathcal{H})$ has property B(n) if ${\mid}T^n{\mid}{\geq}{\mid}T{\mid}^n$, $n{\geq}2$, which generalizes the class A-operator. We characterize the property B(n) of weighted shifts $S_{\lambda}$ over (${\eta},\;{\kappa}$)-type directed trees which appeared in the study of subnormality of weighted shifts over directed trees recently. In addition, we discuss the property B(n) of weighted shifts $S_{\lambda}$ over (2, 1)-type directed trees with nonzero weights are being distinct with respect to $n{\geq}2$. And we give some properties of weighted shifts $S_{\lambda}$ over (2, 1)-type directed trees with property B(2).

MRI T2강조영상에서 측두하악관절 원판 후 조직의 상대적 신호 강도에 대한 연구 (THE RELATIVE SIGNAL INTENSITY OF RETRODISCAL TISSUE IN TMJ USING A T2-WEIGHTED MRI)

  • 예영근;이상화;윤현중
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.457-462
    • /
    • 2005
  • The aim of this study is to evaluate the relative signal intensity of TMJ retrodiscal tissue in T2-weighted MRI as diagnostic marker of temporomandibular disorder(TMD). 58 temporomandibular joints from 29 TMD patients (14 men & 15 women) were evaluated. The relative signal intensity of retrodiscal tissue in T2-weighted MRI was referenced to brain gray matter same size of the region of interest(ROI). The collected data was compared to disc positions (normal, anterior disc displacement with reduction, anterior disc displacement without reduction), the presence of joint effusion. The relative signal intensity of retrodiscal tissue was significantly increased when the disc was displaced without reduction. And the relative signal intensity of retrodiscal tissue was significantly increased when joint effusion was present. The results suggest that evaluating the relative signal intensity of TMJ retrodiscal tissue using a T2-weighted MRI is valuable as a non-invasive tool for diagnosing the procession of TMD.