반건식 배연탈황법에 의한 연소 페가스 중 $SO_2$제거에 관한 연구 (A Study on $SO_2$Removal in Flue Gas by Semidry Flue Gas Desulfurization Method)

  • 송호철;이윤기;박진원
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.273-280
    • /
    • 1998
  • The investigation on the removal of 502 gas fro.In flue gas which causes serious air pollution was made by using a semi dry flue gas desulfurization method. Experiments were carried out as a function of process variables which would affect SO2 removal efficiency. Process variables inclilded SO2 inlet concentration, inlet temperature of simulated flue gas, sorbent weight fraction, and volume flow rate of sorbent slurry. In this study, used sorbent was Ca(OH), and simulated flue gas was prepared by mixing pure SO2 gas with air. Experimental conditions were varied at 140~18$0^{\circ}C$ of inlet temperature of the simulated flue gas, 500~2000ppm of inlet SO2 concentration, 0.4~1.0% of sorbent concentration, and 10~25 mL/min of flow rate of sorbent slurry. Among process variables, inlet concentration of SO2 was found to be the most significant factor to affect SO2 removal efficiency. The concentration of Ca(OH2) had a lower effect on SO2 removal than SO2 inlet concentration removal amount was 0.108, 0.141, 0.153 g SO2/g Ca(OH)2 respectively- As 200 mmol of HNO3 was added into slurry to improve removal efficiency, initial pH was maintained and solubility of slurry increased, so that removal efficiency elevated. Adding over 200 mmol of HNO3 into slurry caused removal efficiency lower. Therefore it could be concluded the optimum was 200 mmol of HNO3 input.

  • PDF

혼합 촉진 장치의 형상에 따른 탈황효율 비교 (Comparison of the $SO_2$ Removal Efficiency by Mixing Enhancement Shape)

  • 정진도;김장우;배영필
    • 대한환경공학회지
    • /
    • 제32권1호
    • /
    • pp.17-22
    • /
    • 2010
  • 본 연구의 목적은 대형 석탄 화력 발전소에 DSI (Dry Sorbent Injection)공정을 실제 적용 할 경우에 실현 가능성에 대한 연구로서 N 발전(주)의 S 화력발전본부에서 운용중인 500MW급 석탄화력 발전시설의 보일러 후단에서 전기 집진기 전 단까지를 모델로 삼아 Lab-scale 실험장치를 제작하여 탈황효율을 높이기 위한 실험을 수행하였다. 이를 위하여 Lobedplate와 Step-plate라는 혼합촉진장치를 고안하고 각각 형상을 달리하여 궁극적으로 탈황효율을 높이기 위한 혼합촉진장치의 최적 형상도출을 위한 실험을 수행하였으며 부수적으로 탈황제의 분사구의 개수에 따른 탈황효율 또한 분석하였다. 그 결과 혼합촉진장치가 설치된 경우가 더 높은 탈황 효율을 나타내었고 형상에서는 계단형상일 경우 가장 높은 탈황효율을 보였다. 또한, 탈황제의 분사구의 개수에 따른 탈황효율은 혼합 촉진 장치가 설치되지 않은 경우, 분사구의 개수가 증가할수록 높은 탈황 효율을 보였으나 혼합촉진장치가 설치된 경우는 분사구의 개수가 4개일 경우가 이론적 결과와 같이 가장 높은 탈황효율을 나타내었다.

실험실 규모 정전기 분무형 반건식 세정기의 SO2 제거효율 향상에 대한 계산 및 실험적 연구 (Numerical and Experimental Study on the Increase of Removal Efficiency of SO2 in a Laboratory Scale Electrostatic Spray Drying Absorber)

  • 변영철;황정호
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1111-1120
    • /
    • 1998
  • Spray Drying Absorber(SDA) system, where the combustion product gas is mixed with atomized limestone-slurry droplets and then the chemical reaction of $SO_2$ with alkaline components of the liquid droplets forms sulfates, has been widely used to eliminate $SO_2$ gas from coal fired power plants and waste incinerators. Liquid atomization is necessary because it can maximize the reaction efficiency by increasing the total surface area and dispersion angle of the alkaline components. First, numerical calculations using FLUENT are carried out to investigate $SO_2$ concentration distribution and thus to calculate $SO_2$ removal efficiency. So to attain the optimized spray conditions, then an electrostatic spraying system is set up and spray visualization is performed to show the effect of an electric field on overall droplet size. Next, the effect of an electric field on the concentrations of $SO_2$ is experimentally examined. Field strength is varied from -10 kV to 10 kV and configurations of conduction charging and induction charging are utilized. Consequently, the electrostatic removal efficiency of 501 increases about 30% with the applied voltage of ${\pm}10kV$ but is independent of polarity of the applied voltage. It Is also found that the conduction charging configuration results in higher efficiency of $SO_2$ removal that the induction charging configuration. Finally, the effect of slurry temperature on $SO_2$ removal is studied. The temperature influences on the electrostatic removal efficiency of $SO_2$.

코로나 샤워 시스템을 이용한 NOx제거에서 $SO_2$의 영향 (The $SO_2$ effect on NOx removal by Corona Shower System)

  • 박재윤;김익균;이재동;김종달;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1794-1796
    • /
    • 1998
  • In this study, the $SO_2$ addition effect on NOx removal has been conducted from a combustion flue gases by the do corona discharge-activated radical shower systems. The simulated flue gases were consisted of NO-O_2-$N_2$, NO-$CO_2-N_2-O_2$ and $NO-SO_2-CO_2-Na-O_2$([NO]o:200ppm and $[SO_2]o$:800ppm). The injection gases used as radical source gases were $NH_3$-Ar-air. $SO_2$ and NOx removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as $SO_2$. NOx and $NO_2$ gas detectors. By-product aerosol particles were also observed by Condensation Nucleation Particle Counter(CNPC) and SEM images after sampling. The results showed that asignificant aerosol Particle formation was observed during a removal operation in corona radical shower systems. The NOx removal efficiency significantly increased with increasing applied voltage and $NH_3$ molecule ratio. The $SO_2$ removal efficiency was not significantly effected by applied voltage and slightly increased with increasing $NH_3$ molecule ratio. The NOx removal efficiency for NO-$SO_2-CO_2-N_2-O_2$ was better than that for NO-$CO_2-N_2-O_2$.

  • PDF

Evaluation of electrical energy consumption in UV/H2O2 advanced oxidation process for simultaneous removal of NO and SO2

  • Shahrestani, Masoumeh Moheb;Rahimi, Amir
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.389-396
    • /
    • 2019
  • The electrical energy consumption (EEC) in removal of NO by a $UV/H_2O_2$ oxidation process was introduced and related to removal efficiency of this gas. The absorption-reaction of NO was conducted in a bubble column reactor in the presence of $SO_2$. The variation in NO removal efficiency was investigated for various process parameters including NO and $SO_2$ inlet concentrations, initial concentration of $H_2O_2$ solution and gas flow rate. EEC values were obtained in these different conditions. The removal efficiency was increased from about 22% to 54.7% when $H_2O_2$ concentration increased from 0.1 to 1.5 M, while EEC decreased by about 70%. However, further increase in $H_2O_2$ concentration, from 1.5 to 2, had no significant effect on NO absorption and EEC. An increase in NO inlet concentration, from 200 to 500 ppm, decreased its removal efficiency by about 10%. However, EEC increased from $2.9{\times}10^{-2}$ to $3.9{\times}10^{-2}kWh/m^3$. Results also revealed that the presence of $SO_2$ had negative effect on NO removal percentage and EEC values. Some experiments were conducted to investigate the effect of $H_2O_2$ solution pH. The changing of pH of oxidation-absorption medium in the ranges between 3 to 10, had positive and negative effects on removal efficiency depending on pH value.

SO2 제거를 위한 유전체 장벽 방전 - 광촉매 복합 공정에서의 입자 형성과 성장 (Particle Formation and Growth in Dielectric Barrier Discharge - Photocatalysts Hybrid Process for SO2 Removal)

  • 나소노바 안나;김동주;김교선
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.127-132
    • /
    • 2010
  • We analyzed the effects of several process variables on the $SO_2$ removal and particle growth by the dielectric barrier discharge - photocatalysts hybrid process. In this process, $SO_2$ was converted into the ammonium sulfate ($(NH_4)_2SO_4$) particles. The size and crystallinity of ammonium sulfate particles were examined by using TEM and XRD analysis. The dielectric barrier discharge reactor consisted of two zones: the first is for plasma generation and the second is for ammonium sulfate particles formation and growth. The first zone of reactor was filled with glass beads as a dielectric material. To enhance $SO_2$ removal process, the $TiO_2$ photocatalysts were coated on glass beads by dip-coating method. As the voltage applied to the plasma reactor or the pulse frequency of applied voltage increases, the $SO_2$ removal efficiency increases. Also as the initial concentration of $SO_2$ decreases or as the residence time increases, the $SO_2$ removal efficiency increases. $(NH_4)_2SO_4$ particles continue to grow by particle coagulation and surface reaction, moving inside the reactor. Larger particles in site are produced according to the increase of residence time or $SO_2$ concentrations.

  • PDF

Improvement of the $SO_{x}$ Removal by Adding Dibasic Acids into the JBR FGD Process

  • Lee, Byeong-Kyu;Jeon, Sang-Ki;Cho, Seong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E4호
    • /
    • pp.157-162
    • /
    • 2001
  • Jet Bubbling Reactors(JBRs) were operated for the removal of SO$_{x}$ in flue gases produced from many electric power plants. However, many JBR flue gas desulfurization (FGD) facility faced a decrease of SO$_{x}$ removal efficiency and an increase of scale problems with continuous operations. We increased alkalinity of the SO$_{2}$ absorbing medium by adding the dibasic acids (DBAs) to solve these problems more effectively. The SO$_{2}$ removal efficiency, the purity of CaCO$_{3}$ and COD of the wastewater was measured to identify the addition effects of DBAs (150, 200, 250, and 400 ppm) for 2hr in a day into the JBR attached to the large-scale power plants (400 MW$\times$3). Addition of the DBAs resulted in the improvement of the SO$_{2}$ removal efficiency from 2 to 5% and the purity of the gypsum from 1 to 2%; these improvement were due to the alkalinity increase of the absorbing medium and the reduction of a proportion of un-reacted CaCO$_{3}$, respectively. Also, the scale problems formed by un-reacted CaCO$_{3}$ inside the reaction zone of the JBR were substantially reduced. Even though the effluent COD of the wastewater slightly increased from 10~15 to 18~36 mg/l and the erosion problems in the injection pump and duct occurred, this method of increasing SO$_{2}$ removal efficiency by adding the DBAs could be considered as a profitable approach.ach.

  • PDF

0.4 MW급 가스분사식 배연탈황 흡수탑의 운전 특성 (Operating Characteristics of 0.4 MW-Scale Gas Dispersion Type FGD Absorber)

  • 안희수;김기형;박승수;박광규;김영호
    • 한국대기환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • This study was carried out to investigate the effect of operating and design conditions of gas dispersion type of absorber on $SO_2$ removal efficiency. pH difference between upper and lower part of gas dispersing plate of absorber was 0.2, which was relatively low. This was supposed that recirculation capacity of absorbing liquid between froth zone and reaction zone of absorber be increased by oxidation air injection through liquid riser which acted as liquid pump. Test results showed that $SO_2$ removal efficiency was more sensitive than absorber ${\Delta}P$. High $SO_2$ removal even at lower pH resulted from very low concentration of $HSO_3^-$ ion in absorbing liquid because of direct supply of dissolved oxygen into froth zone. 96% of $SO_2$ removal efficiency was obtained under the condition of absorber pH 5.2, flue gas flow rate of $1,530\;Nm^3/hr$, inlet $SO_2$ concentration of 800 ppm, absorber ${\Delta}P$ of 250mmAq. The following equation by a multiple linear regression was obtained to describe the relationship between $SO_2$ removal and operating variables. $$f=1-{\exp}(-1.3939+1.060pH+0.0139{\Delta}P-0.00267G-0.000064SO_2Conc.),\;R^2=0.9719$$

순산소연소 조건에서 Drop tube furnace를 이용한 운전변수에 따른 석회석의 탈황특성 연구 (Study on the Desulfurization Characteristic of Limestone Depending on the Operating Parameters of In-Furnace Desulfurization for Oxy-Fuel Combustion Using Drop Tube Furnace)

  • 최욱;조항대;최원길;박영성;길상인;이형근
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.857-864
    • /
    • 2011
  • 순산소연소는 높은 연소 효율과 적은 배가스량, 낮은 질소산화물 농도를 장점으로 하고 있으며 연소온도 조절을 위한 배가스 재순환에 의해 배출되는 연소가스중의 $CO_2$ 농도를 95%까지 농축이 가능하므로 석탄 연소설비에 대한 유망한 CCS 기술로 부각되고 있다. 본 연구는 순산소연소 조건에서 배가스의 재순환을 통한 $CO_2$ 농도 증가에 기인하는 직접 황화반응이 탈황효율에 미치는 영향을 평가하고 반응온도, $CO_2$ 농도, $SO_2$ 농도상승이 $SO_2$ 제거효율에 미치는 영향과 배가스 중 수분 등이 $SO_2$ 제거효율에 미치는 영향을 실험적으로 고찰하였다. 반응온도 $1,200^{\circ}C$까지 온도 상승에 따라 $SO_2$의 제거효율은 증가하였고 Ca/S비, $CO_2$ 농도와 수분이 증가할수록 $SO_2$ 제거효율이 증가하였다. 이러한 운전변수는 영향인자 평가를 통하여 Ca/S 비>체류시간>$O_2$농도>반응온도>$SO_2$농도>$CO_2$농도>수분농도의 순으로 탈황반응에 영향을 미치는 것으로 나타났다. 또한 운전변수별 실험결과를 이용하여 로내 건식탈황에 있어서 각 운전변수별 성능 영향인자를 평가할 수 있는 반경험적 모델식을 도출하였다.

코로나 방전 시스템을 이용한 연소가스중의 NOx, $SO_2$제거 (Removal of NOx and $SO_2$ from Combustion Flue Gases by Corona Discharge Systems)

  • 박재윤
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.830-835
    • /
    • 1997
  • In this study an experimental investigation has been conducted to remove NOx and SO$_2$simultaneously from a combustion flue gases were consisted of NO-SO$_2$-$CO_2$-$N_2$-O$_2$([NO]o:200ppm and [SO$_2$]o:800ppm) and the injection gases used as radical source gases were NH$_3$-Ar-air and CH$_4$-Ar-air. NOx and SO$_2$removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as SO$_2$, NOx and NO$_2$gas detectors. and SEM images after sampling. The results showed that a significant Nucleating Particle Counter(CNPC) and SEM images after sampling. The results showed that a significant aerosol particle formation was observed during a simultaneous NOx and SO$_2$removal operation in corona radical shower systems. The diameter of aerosol particles was in the range of 0.18 to 3.6${\mu}{\textrm}{m}$ with a maximum fraction of particles at particles diameter of 1${\mu}{\textrm}{m}$. The NOx removal efficiency significantly increased with increasing applied voltage and NH$_3$molecule ratio. The SO$_2$removal efficiency was not significantly effected by applied voltage and slightly increased with increasing NH$_3$molecule ratio. It could be found that it is possible to use CH$_4$for NOx and SO$_2$removal by corona radical shower systems.