• Title/Summary/Keyword: $SO_2$ measurement

Search Result 1,940, Processing Time 0.047 seconds

Study on the extraction of characteristics of LTCC RF components (LTCC RF 소자 특성 추출에 관한 인구)

  • 유찬세;이우성;강남기;박종철
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.05a
    • /
    • pp.214-218
    • /
    • 2002
  • So far, many kinds of researches on the ceramic chip components and MCM-C RF module especially on the 3-dimensional ceramic module using embedded passives have been performed. LTCC system has many kinds of advantages, like low lass, low cost of process, stability of process etc.. But it's so hard to adjust the characteristics of passives in ceramic module after fabrication. So the exact prediction of behavior of components in high frequency region upper than 2 GHz must be made. In this procedure, the exact measurement is need. In this study, many kinds of measurement Jigs are compared and optimized, and measurement methods of each parameter are designed.

  • PDF

Design and Function Analysis of Dust Measurement Platform based on IoT protocol (사물인터넷 프로토콜 기반의 미세먼지 측정 플랫폼 설계와 기능해석)

  • Cho, Youngchan;Kim, Jeongho
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.79-89
    • /
    • 2021
  • In this paper, the fine dust (PM10) and ultrafine dust (PM2.5) measurement platforms are designed to be mobile and fixed using oneM2M, the international standard for IoT. The fine dust measurement platform is composed and designed with a fine dust measurement device, agent, oneM2M platform, oneM2M IPE, and monitoring system. The main difference between mobile and fixed is that the mobile uses the MQTT protocol for interconnection between devices and services without blind spots based on LTE connection, and the fixed uses the LoRaWAN protocol with low power and wide communication range. Not only fine dust, but also temperature, humidity, atmospheric pressure, volatile organic compounds (VOC), carbon monoxide (CO), sulfur dioxide (SO2), nitrogen dioxide (NO2), and noise data related to daily life were collected. The collected sensor values were managed using the common API provided by oneM2M through the agent and oneM2M IPE, and it was designed into four resource types: AE and container. Six functions of operability, flexibility, convenience, safety, reusability, and scalability were analyzed through the fine dust measurement platform design.

Study on the Extraction of Characteristics of LTCC RF Components (LTCC RF 소자 특성 추출에 관한 연구)

  • 유찬세;이우성;강남기;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.2
    • /
    • pp.45-48
    • /
    • 2002
  • LTCC system has many kinds of advantages, like low loss, low cost of process, stability of process etc. But it is so hard to adjust the characteristics of passives in ceramic module after fabrication. So the exact prediction of behavior of components in high frequency region upper than GHz must be made. In this procedure, the exact measurement is need. In this study, many kinds of measurement Jigs are compared and optimized, and measurement methods of each parameter are designed.

  • PDF

Analysis of Clinical Measurement Methods of Lower Extremity Alignment (하지정렬의 임상적 측정방법에 대한 분석)

  • Kong Hee-Kyung;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.17-21
    • /
    • 2004
  • We need to study about lower extremity alignment because the structure dictates the function of lower extremity. Through lower extremity alignment assessment in static posture, we recognize abnormal structural conditions which could affect dynamic motion such as gait. To evaluate of lower extremity alignment provide so many useful information, but method of measurement is so limited. Therefore, this review will assist understanding for measurement of lower extremity alignment in static posture. From now on study about the objective measurement method must be achieved much more in physical therapy.

  • PDF

Auto-Measurement of Induction Motor Parameters

  • Kim Kyung-Seo;Byun Sung-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.226-232
    • /
    • 2006
  • This paper presents the parameter measurement methods for high performance drive of induction motors, which are suitable for the self-commissioning function of commercial inverters. In this study, some factors that affect the accuracy of parameter measurement are examined. Measuring methods and conditions that are best fit to each parameter measurement procedure are then proposed. All the measurement procedures can be done without any auxiliary equipment, so that those can be easily adopted as self-commissioning functions of commercial inverters. To improve the measuring accuracy, least square approximation methods are adopted during the measurement procedure. The validity of the proposed methods are confirmed through experiments.

An Analysis of Economic Effects on the Investment of Measurement Standards by Cost Function (비용함수에 의한 측정표준투자의 경제적 효과 분석)

  • 남경희;이병민;김동진
    • Journal of Korea Technology Innovation Society
    • /
    • v.4 no.2
    • /
    • pp.172-181
    • /
    • 2001
  • This is a paper to understand the economic effects of the measurement standards by translog cost function. The data, as of the end of 1998, are from a survey of 514 firms in Korean industry. The analysis is compared to that of 1992 data analysis to check the trend. There are a little differences on the estimated coefficients, but there is no basic difference on trend of economic effects. The Investment on measurement standards have been contributed positively on the major managerial indicators such as productivity, profit, and so on.

  • PDF

A study on 3-D shape measurement for the composition of human bust (인체흉상 합성을 위한 3차원 형상 측정에 관한 연구)

  • 안중근;강영준;최정표;유원재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.220-223
    • /
    • 1997
  • Moire topography method is a well-known non-contacting 3-D measuement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topography is very attractive because of it's high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the 2x-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the 2x-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

Six-degree-of-freedom Manipulator Displacement Measurement using Stereo Vision (스테레오비전을 이용한 6자유도 머니퓰레이터 변위 측정)

  • Lee, Dong-Hyeok;Baek, So Young;Cho, Nahm Gyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • In this paper, six-degree-of-freedom (DoF). Displacement measurement technique using a compact stereo-vision system is proposed. The measuring system consists of a camera, an optical prism, two plane mirrors, and a planar marker on a target. The target was attached on an object so that its six-DoF displacement can be calculated using a proposed coordinates estimating algorithm and stereo images of the marker. A prototype was designed and fabricated for performance test. From the test results, it can be confirmed that the proposed measuring technique can be applied to monitoring and control of various manipulators.

A Study on the Difference in Expectation-Performance of Service Recovery Measurement Scale's 4 Dimensions both Korean Native Cattle Beef and Imported Beef Restaurant

  • Cho, Yoon-Shik;Lee, Mi-Ock
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.4
    • /
    • pp.1123-1131
    • /
    • 2008
  • A considerable amount of research has focused on the dimensionality of service failure and recovery construct. This paper is focused on service failure and recovery in the Korean native cattle and imported beef restaurant industry in the Korea. So, this paper has adapted Kau and Loh's Service recovery measurement scale so that restaurant managers can use it to determine how customers perceive the service quality in Korean native cattle beef restaurant and imported beef restaurant. The purpose of this research is to test the difference in pre-purchase expectation and post-purchase actual performance of 4 dimensions between the restaurants that sell the beef of Korean native cattle and imported cattle. The paired t -test is used to test difference of pre-purchase expectation and post-purchase actual performance for service recovery measurement scale's 4 dimensions of the 2 restaurant types. But, there is significant difference between pre-purchase expectation and post-purchase actual performance in the 2 restaurant types.

  • PDF

Measurement of Absorbed Dose for High Energy Electron using $CaSO_4:Tm$ - PTFE TLD (고에너지 전자선의 흡수선량 측정에 있어서 TLD의 유용성)

  • Park, Myeong-Hwan;Kim, Do-Sung
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.97-101
    • /
    • 2000
  • In this study, the highly sensitive $CaSO_4:Tm$-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. $CaSO_4:Tm$ phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5 mm. thickness $90\;mg/cm^2$) by cold pressing. The absorbed dose distribution and ranges for high energy electron were measured by using the $CaSO_4:Tm$-PTFE TLDs. The ranges determined were $R_{100}=14.5mm$, $R_{50}=24.1mm$ and $R_P=31.8mm$, respectively and the beam flatness, the variation of relative dose in 80% of the field size, was 4.5%. The fabricated $CaSO_4:Tm$-PTFE TLDs nay be utilized in radiation dosimetry for personal, absorbed dose and environmental monitoring.

  • PDF