• Title/Summary/Keyword: $SO_2$ measurement

Search Result 1,944, Processing Time 0.033 seconds

The Effect Of Job Insecurity To The Union Commitment, Dual Commitment and The Union-Related Orientation (고용불안이 노조몰입, 이중몰입, 노사관계행동지향성에 미치는 영향에 관한 연구)

  • Son, Heon-I;Jung, Hyun-Woo
    • Management & Information Systems Review
    • /
    • v.34 no.2
    • /
    • pp.131-149
    • /
    • 2015
  • Recently many organizations have engaged in widespread restructuring as well as more flexible usage of labor in an attempt to cut costs and to increase profit. As a result of lays offs resulting from frequent restructuring, many people no longer consider their jobs as permanent positions. many employees have an increased feeling of job insecurity. There structuring and following downsizing have created an uncertain environment within creased fear offer ther job losses. therefore the study of job insecurity is significant. especially To understand the relationship between job security and union-relation behaviors on the industrial relations. The purpose of this study suggested the strategies to company and union. The purpose of this study is to examine how the union-relation behaviors are influenced by the job security. This study built a exploratory model that there is causal relationship of job security to union commitment, dual commitment, and labor related behaviors. For the verification of this study model, the regression analysis was applied to the surveys of 236 members of union that are located in Busan, Gyeongnam, Ulsan, and Pohang. The result of this research shows that the job insecurity is strongly related to the union commitment and union related behaviors. According to the research, the effect that the job security affects union commitment and union related behaviors are positive. With the research outputs, we have discussed about the academic and pragmatic viewpoint. We proposed comprehensive model to verify how the job insecurity affects the union-related behaviors, and objectively analyzed the model. The research result was opposite to what the existing theories have said that high job insecurity derives high union-related behaviors. This result is meaningful because it is concerned with the social issues-present situation of Korean company, low-employment, unstable employment and so on. Moreover, this research may contribute to expand the aspect of academic research on job insecurity as there are few research conducted in korea. This research also suggests the realistic alternative of union-related behaviors because it is proved that job security can contribute to innovation activities. Also, this research implies that the matter of job insecurity is the basic need of organizational individual and presents that job security is not a notion but the alternative by using of the positional stability and situational control power. The limitation of this research is that it is only utilized the cross-sectional study. To remedy the cross-sectional study, vertical, and serial method of research is needed. And there is no enough sample to secure more comprehensive data as the targets of the research is limited to Busan and Gyeongnam regions. Finally, the measurement tool for job security is needed to be suitably modified to by the South Korea's economic, linguistic, and cultural situation.

  • PDF

Usefulness of Interferon-$\gamma$ Measurement Following Stimulation of Tuberculosis-specific Antigens for Diagnosis of Latent Tuberculosis Infection in Children Exposed to Pulmonary Tuberculosis (폐결핵 접촉력을 가진 소아에서 잠복 결핵 감염의 진단을 위한 결핵 특이항원 자극 인터페론-감마 측정의 유용성)

  • Sung, Ji Yeon;Ki, Joo Hwa;Yang, Mi Ae;Kim, So Hee;Eun, Byung Wook;Kim, Nam Hee;Park, Kyoung Un;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.1
    • /
    • pp.52-58
    • /
    • 2008
  • Purpose : Whole blood interferon-$\gamma$ assay was developed and many studies showed its usefulness in diagnosing tuberculosis (TB) including latent tuberculosis infection (LTBI). However, assessment in children has been limited. This study was undertaken to evaluate the usefulness of QuantiFERON-TB Gold for the diagnosis of LTBI in children exposed to pulmonary TB. Methods : Children who visited Seoul National University Bundang Hospital with a history of TB exposure were enrolled from January 2006 to December 2007. They were evaluated with chest x-rays, tuberculin skin test (TST) and QuantiFERON-TB Gold test. TST was retested 3 months later for those with initial negative reactivity. Definition of LTBI was made on the basis of the TST reactivity. Results : Among the 103 children with a history of TB exposure, 49 children were tested with chest x-ray, TST, and QuantiFERON-TB Gold. Twenty-two were males. Median age was 7.5 years (range; 3 months to 14.7 years). According to TST reactivity, LTBI was in 8 (19%), no infection was in 21 (50%), possible LTBI was in 13 (31%). QuantiFERON-TB Gold test was positive in 5 of the 49 subjects (10%); 3 of the 13 subjects (23.1%) in unknown status, 1 of the 8 subjects (13%) in LTBI, and 1 of the 21 subjects (5%) without infection. The agreement between the QuantiFERON-TB Gold and the TST was poor (${\kappa}=0.101$). Conclusion : QuantiFERON-TB Gold showed poor sensitivity for the diagnosis of LTBI in children with exposure to TB. QuantiFERON-TB Gold alone does not seem to be useful in the diagnosis of LTBI in children.

  • PDF

Comparative Study on the Nurses' Job Satisfaction between the Oriental Medicine Ward and the General Ward (한방병동과 일반병동 간호사의 직무만족도의 비교연구)

  • Byun, Chang-Ja;Choi, Sang-Soon;Paik, Seung-Nam;Lee, Mi-Aie
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.1
    • /
    • pp.97-111
    • /
    • 1995
  • In our society today, a variety of medical caring system, along with a scientific development in the area of oriental medical science plus national demand, has increased the augmentation and the opening of oriental wards and hospitals (Han Bang), which has come to create an additional requirement of nursing activity at oriental medicine wards should be different from that of the general wards or the same as the other. In view of this, various studies need to be made in this connection. The purpose of this study is to comprehend the number of nurses who want to work at oriental medicine wards and measure job satisfaction in nursing as compared with those working at general wards so as to provide basic materials for future assignment and supplementary training for the nurses. An attempt was made to contribute toward nursing administration on the one hand improving nursing training course on the other hand. A total of 72 nurses currently working at two oriental medicine hospitals available in Seoul and 82 general nurses were selected for this study using the questionaire from December 1993 to January 1994. An instrument for the study was based on the measurement of work satisfaction developed by Paula L. Stamps including 37 questions complemented by Kim for revision (1993) and 14 questions regarding general characteristics and oriental medicine wards. The instrument to test dependability showed Cronbach's=0.7711. The collected data have been processed by computer package SPSS. General characteristics of the two groups and the matters involved in oriental medicine wards were calculated into real figure and percentage an similarities between the two groups were analyzed by t-test and F-test according to the characteristics of variables. The comparative test on work satisfaction among the two groups including general characteristics and work factors were conducted by t-test and F-test. The major findings as a result of the study are as follows : 1. As general characteristics, age group of $26{\sim}30$ years are more than any segment of age. As to marital status, the number of those in single status is slightly higher than the married. Approximately 80% of them are graduates of nursing schools and nursing colleges. They are mostly in service for one to three years. There is no significant difference between the two groups. 2. The number of those who want to work at oriental medicine wards represents 40.3% against 58.4%, being in favor of general wards. 3. The reason for service at oriental medicine wards is that "there is room for potential research" which happened to rank first, followed by "easy job," "good working atmosphere" and "growing interest in oriental medicine." 4. Work satisfactions among nurses who work at oriental medicine wards prove greater than that of nurses who work at general wards. 5. Work satisfaction between the two groups by work factors is reflected with significant difference statistically on task requirement, interaction and doctor-nurse relationships. 6. The general charcateristics and the work satisfaction by work factors prove that there are significant difference in age, marital status, education and the period of work. They tend to be more satisfied with the work as they grow in age. Significant differneces are found in the work factors such as autonomy, adiministration and professional job in the relationship with doctor-nurse. As to marital status, the married are more satisfied than the unmarried. There are significant differneces in the factors respecting administration and doctor-nurse college graduates are highly satisfied with task requirement. However, satisfaction with the professional level has proven the highest degree for those having master degree. The period of work and satisfaction : There are significant differneces in task requirement, administration, interactions, professional level and doctor-nurse relationships. As a general rule, the degree of satisfactions is in proportion to the lengrh of service. The following conclusions are drawn based on the fndings mentioned above. Even though the work satisfaction of the nurse who work at oriental medicine ward is relatively high, it is desired that personal consultation be given as to disposition of nurses when they are assigned to oriental medicine wards. It is also recommended that lectures on oriental medicine be conducted through supplementary training and/or basic nursing course in order that they may be motivated for ingenious activities with an increasing sense of self-esteem which will eventually enhance positive changes for the patients who are in need of oriental medicine nursing and for the medical teams. In addition, joint reseaches involvingclinical care and education should be in constant process for unique and scientific development for those who are subject to oriental medicine nursing care.

  • PDF

A study on the Logical Reclassification of Parcel Service Tariffs (택배요금기준의 합리적 재설정에 관한 연구)

  • Cho, Yoon-Sung;Lee, Tae-Hwee
    • Journal of Distribution Science
    • /
    • v.10 no.5
    • /
    • pp.45-55
    • /
    • 2012
  • In Korea, the parcel delivery service was launched officially in 1992, and the market has grown to 13.2 billion units, or 3.5 trillion won, as of 2011. The service companies accept small packages under 30 kg and deliver them on the next day in most domestic areas. This service plays an important role in business and personal activities. The parcel service companies have themselves designed the tariff for the delivery service based on two criteria: weight and the sum of three side lengths. Further, the tariff is graded in steps of three or four rate structures based on size (small, medium, large, and extra-small). However, the basic freight rate is generally decided according to the cargo's weight or measurement size, and an extra rate is added according to some factors (handling, stowability, liability, and so on). The parcel service tariff adopted by the companies is illogically designed, and this study was carried out to assess the need for redesigning the tariff structure. The cargo volume cannot be logically reflected by three side lengths. For example, two parcels measuring 160 cm based on three side lengths may have different volumes, one measuring 0.152 cbm (53.33 cm × 53.33 cm × 53.34 cm) and the other 0.05 cbm (100 cm × 50 cm × 10 cm). A small package of less than120 cm (sum of three side lengths) may have a volume of as much as 0.064 cbm (40 cm × 40 cm × 40 cm). Sample comparison showed that 17% of medium-size parcels (based on the sum of three side lengths) are small-volume packages, 24% of large-size parcels are small- or medium-volume packages, and 40% of extra-big-size parcels are big- or under-size packages. Therefore, if parcel service companies rate their services for volume cargo based on the three side lengths standard, users may have to pay higher than normal rates, particularly because a large percentage of parcels are volume cargo. According to this study, the average weight per 1 cbm is less than 300 kg. Therefore, users face an increasing risk of paying higher than logical freight charges. Generally, transportation companies are called "public interest enterprises," and parcel service companies operate as postal services. Public interest enterprises must provide the delivery service to all customers without discrimination at a reasonable service level and logical service charges. Therefore, parcels service tariffs must be designed and adopted logically. In this study, freight theories and prior research findings were used to consider the importance of freight rates, and distortion of parcel service rates based on the three side lengths system was verified through regression analysis of a parcel sample and sample comparison. In conclusion, volume sizes based on three side lengths have a higher correlation to the rate level than does the sum of three side lengths. Further, compared to the sum of three side lengths, volume size has a higher correlation to cargo weight, which is the most basic factor determining transportation cost. Therefore, the existing parcel service tariff should be changed to weight- and volume-based rates, and the tariff must be graded in steps of 8 to 10 higher rate structures for a logical freight schedule based on service cost.

  • PDF

The Informativeness of Cash Flows and Earnings (현금흐름과 이익의 정보성)

  • Pyo, Young-In
    • Korean Business Review
    • /
    • v.11
    • /
    • pp.241-253
    • /
    • 1998
  • One form of the anomalies of stock price changes as reaction to earnings information is believed to be caused by the so-called earnings fixation, which is the overreaction of stock prices to earnings. According to the Sloan (1996) study, stock price changes are positively associated with earnings at the time of earnings releases, but the association becomes negative after that, as the early overreaction is corrected. However, the problem in his study is to use cash flows computed by adjusting earnings with appropriate income statement and balance sheet items. As Bahnson et al. (1996) show, these cash flows substantially deviate from SFAS No. 95 cash flows and the sample used in this study is found to be subject to this substantial measurement error. Therefore, the result of Sloan might be driven by this error and the reexamination of earnings fixation is warranted. The results are generally consistent with those in Sloan. First, earnings is positively associated with stock price changes at the time of earnings releases, but the association becomes negative after that. Second, cash flows show a weak association with stock price changes at the time of earnings releases, but the association become stronger thereafter. Third, when seperated from cash flows, accruals have an incremental explanation about stock price changes beyond that of cash flows, accruals have a negative association later on. This finding is consistent with stock price overreaction to accruals, even when more cleaner cash flow data are used.

  • PDF

Studies on Creep Behavior for Rice Stalks (벼줄기의 크리이프 거동(擧動)에 관한 연구)

  • Huh, Yun Kun;Kim, Sung Rai;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 1995
  • All agricultural crops and products should be cultured, harvested, handled and processed by the proper mechanical methods in the mechanized farming systems. Agricultural crops might be injured or deformed through various working stages due to static or dynamic forces of machines. Mechanical forces had to be applied with proper degrees to the agricultural crops in incoincidence with properties of crops without any damage of crops so as to increase the work efficiency qualitatively. Knowledges of mechanical properties of agricultural materials are essential to prevent of agricultural crops in relation with mechanical farming system. This study was carried out to examine and analyze the creep behavior of the rice stalk on growing and harvesting periods by mechanical model with computer measurement system in radial directional compressive force and bending force. The creep behavior of the rice stalk could be predicted precisely and its results approached closely to the measured values. The creep behaviors were increased greatly with increase of compressive force, namely, the steady state creep behavior occurred at the force less then 25N and the logarithmic creep behavior at the force bigger than 30N. The instantaneous elastic modulus $E_o$ and the retardation time ${\tau}_K$ were increased together with increase of applied forces, meanwhile the retarded elastic modulus $E_r$ and viscosity ${\eta}_v$ were decreased with increase of applied forces in mechanical model being expected the creep behavior in relation with the level of applied forces, which was well explained that the rice stalk might be visvo-elastic material. In the creep test along the stalk portion with compressive force and bending force, the intermediate portion showed greatest values and also the lower portion showed the least values, which implied that the intermediate portions of rice stalk were very weak. The steady state creep behavior occured at the intermediate portion and the upper portion in the rice stalk at the compressive force larger than 25.0N, which showed the possibility of injury due to external forces.

  • PDF

Study on the Qualitative Discrimination of White, Red, and Black Ginseng Extract (백삼,홍삼과 흑삼 추출물의 정성적 구별법에 관한 연구)

  • Lee, Young-Sang;Im, Deok-Ho;Yang, Jin-Chul;Noh, Deok-Soo;Kim, Kwang-Il;Oh, Soo-Kyo;Choi, Kyo-Chan;Cha, Yun-Hwan
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.1
    • /
    • pp.138-143
    • /
    • 2011
  • This study analyzed the maltol quality, composition ratio of fatty acids, and contents of phenolic compounds in white ginseng extracts(four types), red ginseng extracts(five types), black ginseng extracts(two types), and Chinese ginseng extracts(nine types). By examining patterns in these measurements, we determined the characteristic factors of the extracts and measured the possibility of qualitative analysis. In the analysis of maltol using TLC, white ginseng extracts were not detected while red and black ginseng extracts were detected, so the possibility of detection was considered as a characteristic factor for qualitative analysis. Regarding the composition of fatty acids, palmitic and linoleic acids were the main fatty acids in the ginseng extracts palmitic acid was high in white ginseng extracts while linoleic was low in red ginseng extracts. Regarding the ratio(Pal/Lin) of the two fatty acids, there was a large difference between white ginseng extracts(56.7~64.3%) and red ginseng extracts(32.0~38.5%), and these figures seemed to be characteristic factors for the analysis. For the phenolic compounds, extracts contained maltol, caffeic acid, syringic acid, p-coumaric acid, ferulic acid, and cinnamic acid. White ginseng extracts contained similar percentages of phenolic compounds while red ginseng extracts had high maltol content. According to the measurement results of the percentages of maltol and cinnamic acid, white ginseng extracts showed values below five, whereas red and black ginseng extracts showed 53~289, which was also a characteristic factor for qualitative analysis. Consequently, we found that we can differentiate between ginseng extracts using characteristic factors that we analyzed in an experiment on white ginseng extracts from China.

Exploring Differences of Student Response Characteristics between Computer-Based and Paper-Based Tests: Based on the Results of Computer-Based NAEA and Paper-Based NAEA (컴퓨터 기반 평가와 지필평가 간 학생 응답 특성 탐색 -컴퓨터 기반 국가수준 학업성취도 평가 병행 시행 결과를 중심으로-)

  • Jongho Baek;Jaebong Lee;Jaok Ku
    • Journal of The Korean Association For Science Education
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2023
  • In line with the entry into the digital-based intelligent information society, the science curriculum emphasizes the cultivation of scientific competencies, and computer-based test (CBT) is drawing attention for assessment of competencies. CBT has advantages to develop items that have high fidelity, and to establish a feedback system by accumulating results into the database. However, it is necessary to solve the problems of improving validity of assessment results, lowering measurement efficiency, and increasing management factors. To examine students' responses to the introduction of the new assessment tools in the process of transitioning from paper-based test (PBT) to CBT, in this study, we analyzed the results of the PBT and the CBT conducted in 2021 National Assessment of Educational Achievement (NAEA). In particular, we sought to find the effects on student achievement when only the mode of assessment was changed without change of items, and the effect on student achievement when the items were composed including technology enhanced features that take advantage of CBT. This study is derived through the analysis of the results of 7,137 third-grade middle school students taking one among the three kinds of assessments, which were the PBT or two kinds of CBT. After the assessment, the percentage of correct answers and the item discriminations were collected for each group, and expert opinions on characteristics of response were collected through the expert council involving 8 science teachers with experience in NAEA. According to the results, there was no significant difference between students' achievement results in the PBT and the CBT-M, which means simple mode conversion type of CBT, so it could be explained that the mode effect did not appear. However, it was confirmed that the percentage of correct answers for the construct response items was somewhat high in the CBT, and this result was analyzed to be related to the convenience of the response. On the other hand, there were the items with a difference of more than 10%p from the correct answer rate of similar items, among the items to which technology enhanced functions were applied following the introduction of CBT. According to the analysis of response rate of options, these results could be explained that the students' level of understanding could be more closely grasped through the innovative items developed through the technology enhanced function. Based on the results, we discussed some guidance to be considered when introducing CBT and developing items through CBT, and presented implications.

Study on Nozzle Type and Proper Discharge Pressure of Sprayer for Vehicle Disinfecting System (차량소독장치용 노즐형태와 분무기의 적정토출압력에 관한 연구)

  • Lim, Young-Il;Chang, Dong-Il;Kim, Jeong-Chul;Park, Dong-Suk;Lee, Seung-Joo;Kang, Beom-Sun;Kim, Suk;Gutierrez, Winson M.;Lee, Tae-Hoon;Choi, Chung-Heon;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.119-127
    • /
    • 2016
  • The current disinfection method of vehicles being applied in South Korea has various shortcomings. So, the epidemic has generated continuously at livestock farms. It is very important to develop an effective disinfection system for reduction of the epidemic. And various basic data is required for this development. Therefore, this study was performed to identify the nozzle type and proper discharge pressure of sprayers. The experiment was conducted from January 10, 2012 until February 28, 2012. All the performance measurement experiments were repeated five times. The subjects of experiment were the A, B and C company's products. The sprayed capacity, angle of spray and the covering area ratio were measured for each product. As a result, the sprayed capacity, angle of spray and the covering area ratio were increased as the discharge pressure of the sprayer was increased. In conclusion, the conical shaped of the nozzle is considered more appropriate than V-shaped, and the proper discharge pressure is expected to be at least 20kg/㎠.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF