• Title/Summary/Keyword: $SO_2$ concentration

Search Result 3,793, Processing Time 0.037 seconds

Effect of Electrolyte Concentration Difference on Hydrogen Production during PEM Electrolysis

  • Sun, Cheng-Wei;Hsiau, Shu-San
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.99-108
    • /
    • 2018
  • Proton exchange membrane (PEM) water electrolysis systems offer several advantages over traditional technologies including higher energy efficiency, higher production rates, and more compact design. In this study, all the experiments were performed with a self-designed PEM electrolyser operated at 1 atm and $25^{\circ}C$. Two types of electrolyte were used: (i) potassium hydroxide (KOH), and (ii) sulfuric acid ($H_2SO_4$). In the experiments, the voltage, current, and time were measured. The concentration of the electrolyte significantly affected the electrolyser performance. Overall the best case was with 15 wt% $H_2SO_4$ at the anode channel and 20 wt% at the cathode channel with. In addition, increasing the difference in concentration of the sulfuric acid had an effect on the diffusion. The diffusion flux became larger when the difference in concentration became larger, increasing electrolyser efficiency without the addition of extra energy.

Development of Relationship between Air Quality and Rain Acidity (대기질 - 강우산성도 관계식의 개발)

  • 구자공;유동준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.45-51
    • /
    • 1986
  • The simple and precise model for the estimation of rain acidity from the ambient air quality was developed using the theory of wet scrubber and the chemical equilibria of $SO_2, CO_2, and H_2O$ system. From the measured mixing height, and from the developed relationship between NTU (=number of transfer units) and the concentration of $SO_2$(aq) in rain drops, the HTU (= height equivalent to one transfer unit, i.e. mass transfer resistance) was estimated, and validated with the field-measured data. In Seoul, Korea where the effect of $SO_2$ on rainfall acidity is as high as 84% and the average mixing height is 1 km, the average HTU of $SO_2$ system was found to be 191.5m. The important parameters affecting HTU were identified as rainfall intensity and initial ambient concentration of $SO_2$, and their effects on the value of overall volumetric mass transfer coefficient were quantified.

  • PDF

Chemical Characterization of Rainwater Sampled in Cheju city (제주시 강우의 화학적 조성 특성에 관하여)

  • 이기호;허철구
    • Journal of Environmental Science International
    • /
    • v.5 no.6
    • /
    • pp.739-748
    • /
    • 1996
  • This study was carried out to investigate the chemical characteristics ol rainwater sampled in Cheju City from July 1994 to June 1996. Concentrations of major ions (Cl-,$SO_4^{2-}$, NO_3^-$, $Na^+$, $K^+$, Ca^{2+}$, $Mg^{2+}$ and NH_4^+$) were determined. The pH of rainwater, calculated from the volume weighted H+ concentration, was found to be 5.61, indicating extensive neutralization of the acidity in the rain. The relative magnitude of average ionic concentrations followed the relation Cl-> $SO_4^{2-}$) $Na^+$> Ca^{2+}$> NH_4^+$> NO_3^-$> $Mg^{2+}$> $K^+$. The ions associated with sea salt, namely $Na^+$ and $Cl^-$, dominated the total concentration of ions in the rainwater and the $SO_4^{2-}$ ion accounts for 20% of total concentration. [H+][nss-SO42-+NO3] ratio and a multiple regression for $SO_4^{2-}$ and NO3- ions against $H^+$, $Ca^{2+}$ and $NH_4^+$ suggested that all of $SO_4^{2-}$ and $NO_3^-$ in rainwater was not necessarily associated with $H_2SO_4$ and $HNO_3$, but might also occur in combination with $NH_4^+$ or Ca^{2+}$. The monthly mean concentrations of $SO_4^{2-}$-, Ca^{2+}$ and $NH_4^+$ in spring time was higher than those in other seasons. These results may De attributed to the fertilizer application as the local sources and the yellow sand phenomina as a regional-scale sources.

  • PDF

A Study on Extraction of K2SO4·(NH4)2SO4from the Domestic Alunite ore for Production of Potash-Ammonia Fertilyzer (國産明礬石을 原料로 한 肥料製造에 관한 硏究)

  • 손선관;고명원
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.171-175
    • /
    • 1969
  • This study wa attempted to extract the Potash-Ammonia Fertilyzer in most satisfactory yield from the Uncalcinecl Domestic Alunite ore applying an optimal reaction conditions (Ammonia water concentration and applicable reaction pressure, etc.), it was found that almost all amount of $K_2SO_4$ was extracted in the forms of $K_2SO_4·(NH_4)_2SO_4$mixture under such conditions. The experimental data to note are as follows: 1. The optimal pressure applied to the reaction was 600 to 700 Psig. 2. The optimal concentration of Ammonia water was 7 Mol/L. 3. The reaction time needed was 3 hours. 4. The extraction rate and degree were not at variance with sorts and occurrences of Alunite ore.

  • PDF

Simultaneous Removal of Hydrogen Sulfide and Ammonia Using Thiobacillus sp. IW in a Three-Phase Fluidized-Bed Bioreactor

  • Kum, Sung-Hoon;Oh, Kwang-Joong;Moon, Jong-Hae;Kim, Dong-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.419-422
    • /
    • 2000
  • A three-phase fluidized-bed bioreactor including Thiobacillus sp. IW was tested to remove H_2S and $NH_3$ simultaneously. The inlet $H_2S$ was oxidized to $SO_4^{2-}$ by Thiobacillus sp. IW, and the $NH_3$ reacted with the $SO_4^{2-}$ to form $(NH_4)_2SO_4$. The removal efficiency of $H_2S$ was 98.4-99.9% for an inlet concentration of 36-730 ppm and that of $NH_3$ was 60.2-99.2% for an inlet concentration of 45-412 ppm. The removal efficiency of $NH_3$ was reduced when the inlet loading rate of $NH_3$ was increased above 10 mg/l/h. When the bioreactor was operated for 25 days with a lower inlet concentration of $NH_3$ compared with the of $H_2S$, the bioreactor exhibited an excellent performance with a stable pH, dissolved oxygen content, and cell concentration.

  • PDF

Behaviour of Acidic Gases(SOx, NOx) Adsorption on Aminated PP-g-AAc Ultrafine Fibrous Ion Exchanger (아민화 PP-g-AAc 초극세 이온교환섬유의 산성가스(SOx, NOx) 흡착거동)

  • Choi, Yong-Jae;Choi, Kuk-Jong;Lee, Chang-Soo;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • In this study, the behaviour of $SO_2$ and $NO_2$ adsorption on aminated ultrafine fibrous PP-g-AAc ion exchanger was investigated, The amount of adsorbed $SO_2$ increased with increasing the initial concentration of $SO_2$. The adsorption breakthrough time in the low concentration of $SO_2$ was faster than high concentration. The adsorption breakthrough occurred within 60 min. Approximately 80% of $SO_2$ was adsorbed below 100 ppm $SO_2$ and 90% of $SO_2$ over 100 ppm $SO_2$ respectively. The selective adsorption rate for $NO_2$ was lower than that of $SO_2$. The adsorption rate for $SO_2$ was decreased with increasing flow rate and that of $NO_2$ was 60%. The breakthrough occurred within 60 min. The adsorption rate for $SO_2$ was 92% in the 250 mL/g water content. Isotherm adsorption model for $SO_2$ was close to the Langmuir rather than Freundlich model.

Recovery of $H_2SO_4$from Sulfuric Acid Wastes by Diffusion Dialysis (확산투석에 의한 황산폐액으로부터 황산의 회수)

  • 정진기;남철우;정강섭;이재천
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.26-31
    • /
    • 2002
  • The recovery of $H_2$$SO_4$from sulfuric acid waste was attempted by a diffusion dialysis method using an anion extchange membrane. The effect of flow rate, temperature, concentration of metal ions on the recovery rate was studied. The recovery of $H_2$$SO_4$decreased with the concentration of $H_2$$SO_4$and flow rate. The recovery increased with the flow rate ratio of water/$H_2$$SO_4$solution upto 1 above which no further increase was observed. The flow rate did not affect the rejection of Fe and Ni ions. As a result, about 80% of $H_2$$SO_4$could be recovered from sulfuric acid wastes which contains 4.5M free$-H_2$$SO_4$at the flow rate of 0.26 $1/hr-m^2$. The concentration and purity of recovered $H_2$$SO_4$was 4.3M and 99.8%, respectively.

Effects of NaCl and $Na_2SO_$ on Proline Accumulation and Water Relations through Callus Cultures of Brassica campestris ssp. pekinensis (배추 칼루스 배양시 NaCl 및 $Na_2SO_$가 Proline 축적과 수분관계 에 미치는 영향)

  • 백기엽
    • Journal of Plant Biology
    • /
    • v.34 no.3
    • /
    • pp.185-190
    • /
    • 1991
  • Hypocotyl-derived callus cultures of Brassica pekinensis cv. Chungseng were grown on Murashige-Skoog medium containing NaCl, Na2SO4 and mannitol to clarify the effect of salts on callus growth, proline accumulation and water relations. Na2SO4 was more inhibitory than NaCl when survival rate, growth and fresh:dry weight ratios of established callus were measured. Fresh weight in 0.25% NaCl treatment was more than twice as increasable in comparison to the same concentration of Na2SO4 or control. Proline concentration was increased on either salt, attained at highest levels at the 5th subculture, and fluctuated as affected by both salts or mannitol. Concentrations of redeucing sugars were sharply increased after 2 or 3 times of subculture and decreased by increasing subculture. The water and osmotic potential in callus reached a maximum negative value after two weeks in culture, regardless of salt type and mannitol and tugor remained relatively constant on both salt and mannitol treatments.

  • PDF

A Study on Contaminant Emission and Combustion of Anthracite-Bituminous Coal Blend in a Fluidized Bed Coal Combustor (유동층 연소로에서 유$cdot$무연탄 혼합 연소시 대기오염물질 배출에 관한 연구)

  • 조상원;정종현;손병현;김영식;오광중
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.28-36
    • /
    • 1996
  • The objects of this study were to investigate emissions of air pollutant the particles as well as the combustibility of the low grade domestic anthracite coal and imported high-calorific bituminous coal in the fluidized bed coal combustor. The production of air pollution from anthracite-bituminous coal blend combustion in a fluidized bed coal combustor was evaluated. The effects of air velocity and anthracite fraction on the reaching time of steady state condition was also evaluated. We used coal samples the domestic low grade anthracite coal with heating value of 2,010 kcal/kg and the imported high grade bituminous coal with heating value of 6,520 kcal/kg. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 0.3 m/s which was the fastest. It has been found that $O_2$ and $CO_2$ concentration were reached steady state at about 100 minute. As the height of fluidized bed becomes higher, the concentration s of $SO_2$ and $NO_x$ mainly increased. The concentration of freeboard was the highest and emission concentration was diminished. Also, as anthracite fraction increased, the emission of $SO_x$ concentration was increased. But, it has been found that the variation of $NO_x$ concentration with anthracite fraction was negligible and the difference of emission concentration according to air flow rates was negligible, too. It has been found that $O_2$ concentration decreased and $CO_2$ concentration increased as the height of fluidized bed increased. As anthracite fraction increased, the mass of elutriation particles increased, and $CO_2$ concentration decreased. Also, as air velocity increased, $O_2$ concentration decreased and $CO_2$ concentration increased. Regardless-of anthracite fraction and flow rate, the combustible weight percentage in elutriation particles were high in the case of fine particles.

  • PDF

The quantitative analysis of combustive gases on fire by remote passive open path FT-IR spectrometer (Passive open-path FT-IR spectrometer를 사용한 원거리 화재 연소 가스 정량 분석)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.120-124
    • /
    • 2013
  • It was studied to analyze the $CO_2$, CO, $SO_2$ standard gases of combustion gases by the open path FT-IR spectrometer with passive mode for remote analysis of air pollutant and volcano gases without IR lamp. As result, it was confirmed to have good linearity with more than 0.9 as correlation coefficients on the calibration curve of $CO_2$, CO concentration by MLR method. But in the case of $SO_2$, because the correlation coefficients were 0.88, the linearity could be lower. Finally, the concentration of three gases was predicted on in-site fire experiment under the condition of quantitative analysis. It could measure high $CO_2$ concentration as predicted result, but didn't measure the CO and $SO_2$. According to the result, it was possible to measure the combustion gases to long distance by only open path FT-IR spectrometer without infrared lamp.