• 제목/요약/키워드: $SO_2$ adsorption

Search Result 348, Processing Time 0.026 seconds

Decolorization of Aqueous Caprolactam Solution by Anion-exchange Resins

  • Yuan Zhen;Yu Ping;Luo Yunbai
    • Fibers and Polymers
    • /
    • v.7 no.2
    • /
    • pp.112-116
    • /
    • 2006
  • Caprolactam is the most important raw material for making Nylon 6 fibers and its quality directly determines the quality of Nylon. So it is necessary to study the techniques and methods to remove the colorful impurities from caprolactam. In this paper, the decolorization of caprolactam aqueous solution by anion exchange resins was studied and the decoloring abilities of five commercial resins were investigated. The regeneration of the resins was also studied, too. This study shows that the resin AMTX202 have excellent decoloring ability in the column experiment and that the decoloring efficiency is correlated with the volume of resins packed and is slightly affected by the flow rate and regenerating times. The fact that the resins can be regenerated and reused without affecting the efficiency of decolorization will decrease the cost of the treatment and operation in the industry. The adsorption of colored compounds with anion exchange resins in the packed columns seems to be technically feasible.

Dyeing Properties of Acorn Extract on Wool Fabric (도토리 추출 염액에 의한 모직물 염색)

  • 이전숙
    • Korean Journal of Human Ecology
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 2002
  • Dyeing properties of the colorants extracted from acorn on wool fabric were investigated. Effects of dyeing temperature, dyeing time, repeating, and pH on dye uptake and colorfastness were explored. Acorn colorants showed very good affinity to wool fiber and produced bright to dark brown color ranged 4.81-8.97YR, 4.46-7.47/1.79-3.35. ,Higher temperature increased dye adsorption, so did longer time and more repeating. Washfastness was fairly good. The Dyed wool fabric had deeper color after irradiation to light. pH had an effect on the development of color, also. Dye uptake and washfastness were higher in acidic and alkaline pH than in neutral pH solution.

  • PDF

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

Strength Properties of Non-cement Matrix Mixed with Tourmaline (토르마린을 혼입한 무시멘트 경화체의 강도 특성)

  • Kwon, Hyeong-Soon;Lee, Chang-woo;Hwang, Woo-Jun;Lee, Sang-soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.55-56
    • /
    • 2022
  • As global warming becomes serious, research is continuously being conducted to reduce CO2 emissions. Among building materials, the carbon emission of cement is so high that it accounts for 6.8% of the carbon emission of the entire industry. Studies replacement of cement with blast furnace slag and fly ash are steadily increasing. In addition, efforts are being made to reduce air pollution due to increased damage caused by increased concentrations of harmful substances such as fine dust and heavy metals in the air. There is an increasing number of studies that enable adsorption by mixing adsorbents into building materials. This study reviewed the strength properties to make an adsorbable non-cement finishing material by mixing tourmaline, an adsorbent, based on the non-cement composite, and confirmed that the strength decreases as the replacement ratio increases.

  • PDF

Study on the Surface Reactions of Graphite Electrodes by Anodic Polarization (양극분극에 의한 흑연전극의 계면반응에 대한 연구)

  • 오한준;김인기;이종호;이영훈
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Electrode surface reaction on three carbon materials(glassy carbon, synthesized graphite, graphite foil) in 0.5 M K2SO4 electrolyte is investigated by impedance spectroscopy during anodic polarization. The double layer capacitance of the graphite foil electrode is relatively higher than that of other two materials. The change of capacitance parameter C due to chemical adsorption on glassy carbon and synthesized graphite(PVDF graphite) is observed in 0.5 M K2SO4 solution at anodic polarization. In general, the faradic impedance on glassy carbon depends on anodic polarization, and the change of impedance parameter on graphite foil at anodic polarization is not remarkable, because this reaction is controlled by field transport.

  • PDF

A Study on the Development of Activated Carbon from Rice-Hull (왕겨를 이용한 활성탄 개발에 관한 연구 (I))

  • 이희자;조양석;조광명
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.81-88
    • /
    • 2000
  • Every year, 1.1 million tons of rice-hull are produced in South Korea by the by-product in pounding rice. But they has mainly been utilized as a fuel, agricultural compost and moisture proofs. So, it's very valuable to use waste rice-hull for activated carbon manufacture. SiO2 content was the highest among inorganics in rice-hull. Therefore, the SiO2 extraction experiments were carried out under the various conditions of pH 9 to 14, reaction time from 2 to 24 hrs and various temperature of 20 to 100℃. The results showed that increase in pH and temperature enhanced SiO2 extraction from the carbonized rice-hull. The surface area of the carbonized rice-hull indicating activated carbon adsorption capacity was very small as 178∼191 m2/g at first. However, it was increased to 610∼675 m2/g when extracted in alkali solution at 100℃. When the mixing rate of carbonized rice-hull and NaOH was 1:1.5, iodine No. and surface area of activated rice-hull during 10 min at 700℃ were 1,650 mg/g and 1837 m2/g, respectively. Subsequently, an activated carbon with specific surface area of 1,300∼1,900m2/g was manufactured in a short contact time of 10∼30 min with a mixing rate of 1:1.5 in carbonized rice-hull and NaOH, and iodine No. and specific surface area increased as the amount of SiO2 removal increased.

  • PDF

A Study on the Treatment of Wastewater from Small-scale dyehouse (소규모 염색공장 폐수의 처리에 관한 연구)

  • 이준현;허항록;김광진;김민영;신재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF

Effect of Ca Ion on the SCR Reaction over VOx/TiO2 (Ca 이온이 VOx/TiO2 SCR 반응에 미치는 영향 연구)

  • Kim, Geo Jong;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.27 no.2
    • /
    • pp.165-170
    • /
    • 2016
  • In this study, we investigated the cause of the decrease in activities of $VO_x/TiO_2$ SCR catalyst used for the burner reactor at a scale of $150000Nm^3/hr$ using X-ray diffraction (XRD), brunauer-emmett-teller (BET), atomic emission spectroscopy inductively coupled plasma (AES ICP), $H_2$ temperature programmed reduction ($H_2$-TPR), and $NH_3$ temperature programmed desorption ($NH_3$-TPD) analysis. Since the crystallization of the $VO_x$ and phase transition of $TiO_2$ did not occur, it was concluded that the catalyst was not deactivated by the thermal effect. In addition, from the elemental analysis showing that a large quantity of calcium was detected but not sulfur, the deactivation process of the $VO_x/TiO_2$ SCR catalyst was mainly caused by Ca but not by $SO_2$. The calcium was also found to decrease the catalytic activity by means of reducing $NH_3$ adsorption.

Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling (혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향)

  • Yang, Hyeok Syng;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

Column Preconcentration and Determination of Cobalt(II)Using Silica Gel Loaded with 1-Nitroso-2-naphthol

  • Shin, Eun-Mi;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1516-1520
    • /
    • 2009
  • A sensitive technique for the determination of trace Co(II) in various samples after column preconcentration by adsorbing onto silica gel loaded with 1-nitroso-2-naphthol was developed. Several experimental conditions, such as pH of sample solution, the amount of silica gel loaded with 1-nitroso-2-naphthol, the flow rate for adsorption and so forth, were optimized. The interfering effects of diverse concomitant ions were investigated. Fe(III) interfered with more than any other ions, but the interference by Fe(III) was completely eliminated by adjusting the amount of silica gel loaded with 1-nitroso-2-naphthol to 0.30 g. The dynamic range, the correlation coefficient ($R^2$), and the detection limit obtained by the proposed technique were 3.0-140.0 ng m$L^{-1}$, 0.9942, and 1.81 ng m$L^{-1}$, respectively. For validating the technique, the aqueous samples (tap water, reservoir water, stream water, and wastewater) and the plastic samples were used as real samples. Recovery yields of 93.0-107.0% were obtained. These measured data were not different from ICP-MS data at the 95% confidence level by F test. Based on the results of the experiment, it has been found that the proposed technique can be applied to the determination of Co(II) in various real samples.