• Title/Summary/Keyword: $SF_6$ analysis

Search Result 280, Processing Time 0.05 seconds

Analysis on the Mass Loss in Self-blast type $SF_6$ Gas Circuit Breaker (Self-blast형 $SF_6$ 가스 차단기의 노즐용삭 분석)

  • Jeong, Young-Woo;Bae, C.Y.;Ahn, H.S.;Choi, J.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1422-1423
    • /
    • 2006
  • In our study, the PTFE nozzle ablation in the high-voltage self-blast type $SF_6$ gas circuit breaker was investigated. The test circuit breaker has the structure that the pin electrode is moving and the pressure reservoir volume and the dimension is almost same as commercial 145kv 40kA circuit breaker for similar result in real circuit breaker. The variation of current and arcing time was the range of $36kA_{rms}$(symmetry) - $40kA_{rms}$(asymmetry) and 10-16 ms. From the measured data the tendecy of the mass loss of the nozzle to current load and arc energy was estimated. In this process, the distance from the arc to nozzle(PTFE) surface, area which was exposed to arc and stroke contour was considered. These results will be used to enhance the accuracy of the computational fluid dynamics analysis in circuit breaker and estimate the residual life time of a circuit breaker.

  • PDF

Three-dimensional Analysis for Three-phase Spacers in Gas Insulated System (3차원 전계해석 기법을 이용한 GIS 삼상 일괄형 스페이서 고찰)

  • Kang, J.S.;Lee, B.W.;Kang, S.M.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1620-1622
    • /
    • 2003
  • Recently, as the technology for the development of high voltage power apparatus using SF6 gas has made remarkable progress, it became possible to develop more compact power apparatus adopting single body substation system. In these gas insulated power apparatus, it is impossible to achieve perfect and safe insulation using only SF6 gas, because some solid insulation parts should be installed to support current-carrying conductor parts for electrical and mechanical safety. When spacers were installed in SF6 gas insulation system, they were exposed to severe electrical intensification which could reduce system insulation performance and restrict the rated operating voltage So, it is necessary to clarify the dielectric characteristics of spacers by analytically and experimentally, in order to design and develop more compact and optimum gas insulated systems. In this paper, the field distribution of three-phase spacers were investigated using three dimensional electrostatic field analysis tool adopting BEM method. And the obtained results were compared to the conventional two dimensional computations. According to these three dimensional calculations, it was possible to find out weak points in the spacer more clearly and these results could be applied to design more compact and optimum three phase spacer developments.

  • PDF

The effect of silk fibroin and rhBMP-2 on bone regeneration in rat calvarial defect model (백서 두개골결손모델에서 실크단백과 골형성단백 이식체가 골재생에 미치는 영향)

  • Nam, Jeong-Hun;Noh, Kyung-Lok;Pang, Eun-O;Yu, Woo-Geun;Kang, Eung-Sun;Kweon, Hae-Yong;Kim, Seong-Gon;Park, Young-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.366-374
    • /
    • 2010
  • Introduction: This study evaluated the capability of silk fibroin (SF) and recombinant human bone morphogenetic protein-2 loaded SF (SF-BMP) as a bone defect replacement matrix when grafted in a calvarial bone defect of rats in vivo. Materials and Methods: A total 70 calvarial critical size defects (5.0 mm in diameter) made on 35 adult female Sprague-Dawley rats were used in this study. The defects were transplanted with (1) rhBMP-2 loaded silk fibroin graft (SF-BMP: 0.8+$10\;{\mu}g$), (2) Silk fibroin (SF: $10\;{\mu}g$), and (3) no graft material (Raw). The samples were evaluated with soft x-rays, alkaline phosphatase activity, calcium/phosphate quantification, histological and histomorphometric analysis at postoperative 4 and 8 weeks. Results: The SF-BMP group ($48.86{\pm}14.92%$) had a significantly higher mean percentage bone area than the SF group ($24.96{\pm}11.01%$) at postoperative 4 weeks.(P<0.05) In addition, the SF-BMP group ($40.01{\pm}12.43%$) had a higher % bone area at postoperative 8 weeks than the SF group ($33.26{\pm}5.15%$). The mean ratio of gray scale levels to the host bone showed that the SF-BMP group ($0.67{\pm}0.08$) had a higher mean ratio level than the SF group ($0.61{\pm}0.09$) at postoperative 8 weeks. These differences were not statistically significant.(P=0.168 and P=0.243, respectively) The ratio of the calcium and phosphate contents of the SF-BMP ($0.93{\pm}0.22$) group was lower than that of the SF ($1.90{\pm}1.42$) group at postoperative 4 weeks. However, the SF-BMP group ($0.75{\pm}0.31$) had a higher Ca/$PO_4$ ratio than the SF ($0.68{\pm}0.04$) at postoperative 8 weeks. These differences were not statistically significant.(P=0.126 and P=0.627, respectively) For the bone-specific alkaline phosphatase (ALP) activity, which is recognized as a reliable indicator of the osteoblast function, the SF-BMP ($23.71{\pm}8.60\;U/L$) groups had a significantly higher value than the SF group ($12.65{\pm}6.47\;U/L$) at postoperative 4 weeks.(P<0.05) At postoperative 8 weeks, the SF-BMP ($21.65{\pm}10.02\;U/L$) group had a lower bone-specific ALP activity than the SF group ($16.72{\pm}7.35\;U/L$). This difference was not statistically significant.(P=0.263) For the histological evaluation, the SF-BMP group revealed less inflammation, lower foreign body reactions and higher bone healing than the SF group at postoperative 4 and 8 weeks. The SF group revealed more foreign body reactions at postoperative 4 weeks. However, this immunogenic reaction decreased and the remnant of grafted material was observed at postoperative 8 weeks. For histomorphometric analysis, the SF-BMP group had a significantly longer bone length to total length ratio than those of the SF group at postoperative 4 and 8 weeks.(P<0.05) Conclusion: The rhBMP-2 loaded silk fibroin graft revealed fewer immunoreactions and inflammation as well as more new bone formation than the pure silk fibroin graft. Therefore, silk fibroin may be a candidate scaffold for tissue engineered bone regeneration.

3-Dimensional Micro-Computed Tomography Study on Bone Regeneration with Silk Fibroin, rh-Bone Morphogenetic Protein Loaded-Silk Fibroin and Tricalcium Phosphate Coated-Silk Fibroin in Rat Calvaria Defect

  • Pang, Eun-O;Park, Young-Ju;Park, Su-Hyun;Kang, Eung-Sun;Kweon, Hae-Yong;Kim, Soeng-Gon;Ko, Chang-Yong;Kim, Han-Sung;Nam, Jeong-Hun;Ahn, Jang-Hun;Chun, Ji-Hyun;Lee, Byeong-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the bone regeneration capacity of silk fibroin (SF) when combined with beta tricalcium phosphate (${\beta}$-tricalcium phosphate [TCP]) and rh-bone morphogenetic protein (BMP) in vivo by micro-computed tomography (CT), soft x-ray, and histological analysis. Methods: A total of 56 critical size defects formed by a trephine bur made on 28 adult female Spague-Dawley rats were used for this study and the defect size was 5.0 mm in diameter. The defects were transplanted with (1) no graft material (raw defect), (2) autogenous bone, (3) SF ($10{\mu}g$), (4) SF-BMP ($10{\mu}g$, $0.8{\mu}g$ each), and (5) SF+${\beta}$-TCP ($10{\mu}g$). At 4 and 8 weeks after operation, the experimental animals were sacrificed. Samples were evaluated with soft x-ray, histological examinations and 3-dimensional micro-CT analysis. Results: In the 3-dimensional micro-CT evaluation, bone volume and bone surface data were higher in the SF-BMP ($12.8{\pm}1.5$, $138.6{\pm}45.0$ each) (P<0.05) and SF-TCP ($12.3{\pm}1.5$, $144.9{\pm}30.9$ each) group than in the SF group ($6.1{\pm}3.3$, $77.2{\pm}37.3$ each) (P<0.05), except for the autogenous group ($15.0{\pm}3.0$, $190.7{\pm}41.4$ each) at 4 weeks. At 8 weeks, SF-BMP ($16.8{\pm}3.5$, $173.9{\pm}34.2$ each) still revealed higher (P<0.05) bone volum and surface, but SF-TCP ($11.3{\pm}1.5$, $1132.9{\pm}52.1$ each) (P=0.5, P=0.2) revealed the same or lower amount compared with the SF group ($13.8{\pm}2.7$, $127.5{\pm}44.8$ each). The % of bone area determined by radiodensity was higher in the SF-TCP ($31.4{\pm}9.1%$) and SF-BMP ($36.2{\pm}16.2%$) groups than in the SF ($19.0{\pm}10.4$) group at the period of 4 weeks. Also, in the histological evaluation, the SF-BMP group revealed lower inflammation reaction, lower foreign body reaction and higher bone healing than the SF group at postoperative 4 weeks and 8 weeks. The SF-TCP group revealed lower inflammation at 4 weeks, but accordingly, as the TCP membrane was absorbed, inflammatory and foreign body reaction are increased at 8 weeks. Conclusion: The current study provides evidence that the silk fibrin can be used as an effective grafted material for tissue engineering bone generation through a combination of growth factor or surface treatment.

Analysis of Small Current Interruption Performance for $SF_6$ Gas Circuit Breaker ($SF_6$ 가스차단기의 소전류 차단성능 해석)

  • Kim, Hong-Kyu;Song, Ki-Dong;Chong, Jin-Kyo;Oh, Yeon-Ho;Park, Kyong-Yop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.10
    • /
    • pp.528-533
    • /
    • 2006
  • To analyze the small current interruption performance for the gas circuit breakers, the gas density and electric field intensity should be calculated. In this paper, the FVFLIC method is used for the gas flow analysis and the FEM for the electric field analysis. Then, the dielectric withstanding voltage is evaluated by the empirical formulation or Streamer theory. By comparing the calculated dielectric strength with the test result, it is found that both methods show good prediction capability for the small current interruption performance. Especially, when both methods predict the same interrupting performance, the prediction is in accordance with the experimental result.

Numerical Study of SF6 arc with Copper Contamination

  • Liau Vui-Kien;Lee Byeong-Yoon;Song Ki-Dong;Park Kyong-Yop
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.233-241
    • /
    • 2005
  • The present model of a SF6 arc accounts for the copper vapour contamination from the electrodes inside a Laval nozzle of a circuit breaker. Steady state simulations have been done for the arc with electrode gap of 60mm and DC electric current of 500A, 1000A and 1500A for both cases with and without copper contamination. The effects of electrode polarity are considered for the arc current of 1000A. It was found out that evaporation of copper from the anode results in a cooling of the arc in a region close to the electrodes. The electrical potential across the electrodes is not sensitive to the presence of copper vapour, typically less than $4\%$ difference. Transient analysis has been done in order to obtain the arc properties at current zero. The arc current is increased linearly from -1000 to 0A when the upstream electrode is cathode with constant dI/dt of $27.0A/{\mu}s$ (or decreased linearly from 1000 to 0A when upstream electrode is anode). It has been predicted that the presence of copper vapour reduces the interruption capability of the breaker.

AC Breakdown Analysis by Epoxy Thickness in Composite-Insulation (복합절연물내의 에폭시 두께에 따른 AC 절연파괴 분석)

  • Jung, Hae-Eun;Yun, Jae-Hun;Kim, Byoung-Chul;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.468-469
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising, because $SF_6$ gas is one of the main greenhouse gases. As one of the study for $SF_6$ free technology, composite-insulation technology is focused in this paper. To analyze the influence by epoxy thickness change, the composite-insulation composed of dry-air and epoxy was used in this paper. To analyze AC breakdown by the epoxy thickness, needle-plane electrode was used and needle was molded by epoxy. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

Expression of Codon Optimized β2-Adrenergic Receptor in Sf9 Insect Cells for Multianalyte Detection of β-Agonist Residues in Pork

  • Liu, Yuan;Wang, Jian;Liu, Yang;Yang, Liting;Zhu, Xuran;Wang, Wei;Zhang, Jiaxiao;Wei, Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.9
    • /
    • pp.1470-1477
    • /
    • 2019
  • ${\beta}_2$-adrenergic receptor (${\beta}_2-AR$) was expressed efficiently using Bac-to-Bac Baculovirus Expression System in Sf9 cells as a bio-recognition element for multianalyte screening of ${\beta}$-agonist residues in pork. Sf9 cells were selected as the expression system, and codon optimization of wild-type nucleic acid sequence and time-dependent screening of expression conditions were then carried out for enhancing expression level and biological activity. Under optimum conditions of multiplicity of infection (MOI) = 5 and 48 h post transfection, the protein yield was up to 1.23 mg/ml. After purification by chromatographic techniques, the purified recombinant protein was applied to develop a direct competitive enzyme-linked receptor assay (ELRA) and the efficiency and reliability of the assay was determined. The IC50 values of clenbuterol, salbutamol, and ractopamine were 28.36, 50.70, and $59.57{\mu}g/l$, and clenbuterol showed 47.61% and 55.94% cross-reactivities with ractopamine and salbutamol, respectively. The limit of detection (LOD) was $3.2{\mu}g/l$ and the relevant recoveries in pork samples were in the range of 73.0-91.2%, 69.4-84.6%, and 63.7-80.2%, respectively. The results showed that it had better performance compared with other present nonradioactive receptorbased assays, indicating that the genetically modified ${\beta}_2-AR$ would have great application potential in detection of ${\beta}$-agonist residues.

Experimental Study of Reactive Ion Etching of Tungsten Films Using $SF_6$ Plasma ($SF_6$플라즈마를 이용한 텅스텐 박막의 반응성이온식각에 관한 실험적 연구)

  • 박상규;서성우;이시우
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.7
    • /
    • pp.60-74
    • /
    • 1993
  • Experiments of RIE of tungsten films using SF$_{6}$ plasma were conducted to investigate the effect of process parameters on etch rate, uniformity, anisotropy, and selectivity. As power increased, the etch rate increased. Maximum etch rate was obtained at 200mtorr As interelectrode spacing increased the etch rate increased for P < 200mtorr while it decreased for P> 200mtorr. Etch rate was maximum at 20 sccm gas flow rate. As substrate temperature increased, the etch rate increased and activation energy was 0.046 eV. In addition, maximum etch rate was acquired at 20% $O_{2}$ addition. The etch rate slightly increased when Ar was added up to 20% while it continuously decreased when N$_{2}$ was added. Uniformity got improved as pressure decreased and was less than 4% for P <100mtorr. Mass spectrometer was utilized to analyze gas composition and S and F peaks were observed from XPS analysis with increasing power. The anisotropy was better for smaller power and spacing, and lower pressure and temperature. It improved when CH$_{4}$ was added and anisotropic etch profile was obtained when about 10% $O_{2}$ was added. The selectjvity was better for smaller power larger pressure and spacing, and lower temperature. Especially. low temperature processing was proposed as a novel method to improve the anisotropy and selectivity.

  • PDF

Development of the replaced Eco-friendly SIS with GIS for 25.8kV class (25.8kV $SF_6$가스절연 스위치기어(GIS)를 대체한 친환경 고체절연 스위치기어(SIS) 개발)

  • Ma, Ji-Hoon;Zheng, Meng-Lei;Yoo, Lyun;Won, Sung-Yoen;Lee, Seog-Won;Kim, Young-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1219_1220
    • /
    • 2009
  • In recent years, the companies of electric power equipment for MV, HV class trend to develop that the eco-friendly insulated(solid, eco-gas, air etc.) switchgear replace with existent SF6 gas insulated switchgear by environmental problems such as global warming and soon. This paper introduces the Solid Insulated Switchgear(SIS) which is the epoxy of eco-friendly insulation material. The characteristic of SIS to introduce in this paper is as following. 1) Eco-friendly. (SF6 gas free) 2) The structure of flexible system. (Expansion) 3) The optimum design. (The Analysis of electrical & mechanical) 4) An Interface treatment between epoxy and insert. (Molding technology) This paper described about some technology for development of SIS.

  • PDF