• 제목/요약/키워드: $R_{max}$

검색결과 920건 처리시간 0.023초

MaxR(M) AND ZARISKI TOPOLOGY

  • ANSARI-TOROGHY, H.;KEIVANI, S.;OVLYAEE-SARMAZDEH, R.
    • 호남수학학술지
    • /
    • 제28권3호
    • /
    • pp.365-376
    • /
    • 2006
  • Let R be a commutative ring and let M be an R-module. Let X = $Spec_R(M)$ be the prime spectrum of M with Zariski topology. In this paper, by using the topological properties of X, we will obtain some conditions under which $Max_R(M)=Spec_R(M)$.

  • PDF

Mischmetal-FeB-(Co,Ti,Al) 영구자석 (Mischmetal-FeB-(Co,Ti,Al) Permanent Magnets)

  • 고관영;윤석길;김세환
    • 한국재료학회지
    • /
    • 제9권10호
    • /
    • pp.1037-1040
    • /
    • 1999
  • 열간압축 및 다이업셋한 Mischmetal-FeB-(C0,Ti,Al) 영구자석의 자기적 특성과 미세조직을 시료진동형 자력계, 투과전자 현미경, 주사전자 현미경, X-선 회절기를 이용하여 조사하였다. $\textrm{(MM)}_{12.5}\textrm{Fe}_{71.9}\textrm{Co}_{5.0}\textrm{Al}_{2.0}\textrm{B}_{8.6}$조성의 열간압축 자석은 $\textrm{H}_{c}$=4.27 kOe, $\textrm{B}_{r}$=4.75 kG, $\textrm{(BH)}_{max}$=3.82 MGOe의 특성을 보였다. 다이업셋 자석은 $\textrm{H}_{c}$=3.10 kOe, $\textrm{B}_{r}$=5.58 kG, $\textrm{(BH)}_{max}$=5.34 MGOe의 특성을 나타냈다. $\textrm{(MM)}_{12.5}\textrm{Fe}_{77.9}\textrm{Ti}_{1.0}\textrm{B}_{8.6}$ 조성의 경우, 열간압축 자석은 $\textrm{H}_{c}$=3.75 kOe, $\textrm{B}_{r}$=4.64 kG, $\textrm{(BH)}_{max}$=2.78 MGOe, 다이업셋 자석은 $\textrm{H}_{c}$=3.29 kOe, $\textrm{B}_{r}$=5.01 kG, $\textrm{(BH)}_{max}$=3.54 MGOe의 특성을 보였다. X-선 회절 및 투과전자 현미경 조사결과에 의하면, 다이업셋 자석에서 c축이 다이업셋 방향으로 놓이는 결정이방성이 나타나며, 이는 다이어셋 자석의 에너지적의 증가와 관련이 있는 것으로 보인다. Co의 Fe에 대한 일부 치환은 열간압축자석의 자기이방성을 증가시키는 것으로 나타났다.

  • PDF

Liquid-Phase Sintered SiC Ceramics with Oxynitride Additives

  • Rixecker, G.;Biswas, K.;Wiedmann, I.;Sldinger, F.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 2000년도 Proceedings of 2000 International Nano Crystals/Ceramics Forum and International Symposium on Intermaterials
    • /
    • pp.1-33
    • /
    • 2000
  • Silicon carbide ceramics with sintering additives from the system AlN-Y$_2$O$_3$ can be gas-pressure sintered to theoretical density. While commonly a combination of sesquioxides is used such as Al$_2$O$_3$-Y$_2$O$_3$, the oxynitrid additives offer the advantage that only a nitrogen atmosphere is require instead of a powder. By starting form a mixture of ${\beta}$-SiC and ${\alpha}$-SiC, and by performing dedicated heat treatments after densification, anisotropic grain growth is obtained which leads to a platelet microstructure showing enhance fracture toughness. In the present work, recent improvement of the mechanical behaviour of these materials at ambient and high temperatures is reported. By means of a surface oxidation treatment in air it is possible to obtain four-point bending strengths in excess of 1 GPa, and the strength retention at high temperatures is significantly improved.

  • PDF

Preparation of Lacosamide Sustained-release Tablets and Their Pharmacokinetics in Beagles and Mini-pigs

  • Ahn, Jae Soon;Kim, Kang Min;Nam, Dae Sik;Kang, Kyoung Un;Choi, Peter S.;Jeong, Seo Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.557-561
    • /
    • 2014
  • The aim of the present study was to improve dosing of lacosamide, a functionalized amino acid used as an antiepileptic agent, from twice daily to once daily for the convenience of patients. A sustained-release lacosamide tablet was developed and dissolution testing was employed to determine in vitro release behavior using water or buffer solutions at pH 1.2, 4.0, or 6.8. Lacosamide was released for 12 h from the sustainedrelease (SR) tablet, as compared to complete release within 1 h from an immediate-release $Vimpat^{(R)}$ tablet. Each formulation (100 mg) was orally administered to six beagle dogs and six mini-pigs under fasted conditions, and pharmacokinetic parameters such as the area under the concentration time curve ($AUC_t$), the maximum plasma concentration ($C_{max}$), and the time at which this occurred ($T_{max}$) were calculated. These results showed similar values for $AUC_t$, $C_{max}$, and $T_{max}$ following oral administration of immediate-release ($Vimpat^{(R)}$) and SR lacosamide tablets.

슈프락스 캅셀 (세픽심 100 mg)에 대한 세피린 캅셀의 생물학적 동등성 (Bioequivalence of Cepirin Capsule to Suprax Capsule (Cefixime 100 mg))

  • 정은주;강원구;권광일
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권2호
    • /
    • pp.145-149
    • /
    • 1999
  • Bioequivalence of two cefixime capsules, test drug ($Cepirin^R$ capsule: Cheiljedang Corp.) and reference drug ($Suprax^R$ capsule: Dong A Pharm. Com.), was evaluated according to the guidelines of Korea Food and Drug Administration (KFDA). Sixteen healthy volunteers were divided randomly into two groups and administered the drug orally at the dose of 400 mg as cefixime in a $2{\times}2$ crossover study. There was a 1-week washout period between the administrations. Blood samples were taken at predetermined time intervals for 12 hour and the plasma concentration of cefixime was determined with a HPLC method. $AUC_{0-12hr}$ (area under the plasma concentration-time curve form time zero to 12 hour), $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were estimated from the plasma drug concentrationtime data. Analysis of variance (ANOVA) revealed no difference in $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$ between the formulations. The apparent differences of these parameters between the formulations were less than 20% (i.e., 8.62, 11.10 and 0.00% for $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$,respectively). The powers $(1-{\beta})$ for $AUC_{0-12hr}$ $C_{max}$ and $T_{max}$ were over 0.9. Minimal detectable difference $({\Delta})$ at ${\alpha}=0.05$, $1-{\beta}=0.8$ were less than 20% (i.e., 12.84, 11.05 and 17.99% for $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$, respectively). The 90% confidence intervals $({\delta})$ for these parameters were also within ${\pm}20%$ (i.e., $-0.53{\le}{\delta}{\le}17.76$, $3.23{\le}{\delta}{\le}18.97$ and $-12.81{\le}{\delta}{\le}12.81$ for $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$, respectively). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating the two formulations of cefixime were bioequivlent.

  • PDF

프레팔시드 정(시사프리드 5 mg)에 대한 시사플 정의 생물학적 동등성 (Bioequivalence of Prepulsid Tablet to Cisaple Tablet (Cisapride 5 mg))

  • 곽손혁;남진경;장혁;한정희;우종수;이계주;박종우;구선회;황성주
    • Journal of Pharmaceutical Investigation
    • /
    • 제30권1호
    • /
    • pp.55-59
    • /
    • 2000
  • Bioequivalence of two cisapride tablets, test drug ($Cisple^{\circledR}$ tablet: Hanmi Pharm Co., Ltd.) and reference drug ($Prepulsid^{\circledR}$ tablet: Janssen Pharm. Co., Ltd.), was evaluated according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty two healthy male volunteers were divided randomly into two groups and administered the drug orally at the dose of 10 mg as cisapride in a $2{\times}2$ crossover study. There was a week washout period between administrations. Blood samples were taken at predetermined time intervals for 36 hr and the plasma concentration of cisapride was determined by a HPLC method. $AUC_{0-36hr}$ (area under the plasma concentration-time curve from time zero to 36 hr), $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were estimated from the plasma drug concentration-time data. Analysis of variance (ANOVA) revealed no difference in $AUC_{0-36hr},\;C_{max}\;and\;T_{max}$ between two products. The apparent differences of these parameters between two products were less than 20% (i.e., 5.38, 6.17 and 0.00% for $AUC_{0-36hr},\;C_{max}\;and\;T_{max},$ respectively). The powers $(1-\beta)$ for $AUC_{0-36hr},\;C_{max}\;and\;T_{max}$ were over 0.9. Minimal detectable differences $(\Delta)$ at ${\alpha}=0.05,\;1-{\beta}=0.8$ were less than 20% (i.e. 17.67, 14.84 and 19.72% for $AUC_{0-36hr},\;C_{max}\;and\;T_{max},$ respectively). The 90% confidence intervals $(\delta)$ for these parameters were also within ${\pm}20%$ $(i.e.\;-4.97\;{\le}{\delta}{\le}\;15.73,\;-2.53{\le}{\delta}{\le}\;14.86\;and\;-11.55{\le}{\delta}{\le}\;11.55$ for $AUC_{0-36hr},\;C_{max}\;and\;T_{max},$ respectively). These results satisfied the criteria of KFDA guidelines for bioequivalence, indicating the two tablets of cisapride were bioequivalent.

  • PDF

WiBro의 IMT-2000 표준 채택에 따른 시장의 변화 (WiBro Market Change induced by IMT-2000 Standard Adoption)

  • 장재혁
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.649-652
    • /
    • 2007
  • 세계 각 국은 Mobile WiMAX 주파수를 다양한 대역에서 도입을 시도하고 있다. 특히 2.5 GHz 대역은 WRC에서 정한 IMT-2000 추가 대역으로 향후 이동통신용으로 사용될 것으로 전망되며, Mobile WiMAX 등 글로벌 무선광대역서비스 제공이 가능한 대역으로 주목받고 있다. 그런데, 국내 기술인 WiBro의 세계시장 진출 기반 조성을 위하여 ITU-R 산하 WP8F 회의에서 Mobile WiMAX를 IMT-2000 기술 표준으로 포함시키기 위한 활동을 전개 하였으며, 최근 ITU-R 전파통신총회에서 한국의 WiBro 기술을 3G 기술 표준으로 최종 승인했다. 이에 본 고는 주요국의 2.5 GHz 대역 이용계획과 WiBro 기술의 IMT-2000 표준 채택에 따른 시장의 변화를 알아보고자 하였다.

  • PDF

SOME Lq INEQUALITIES FOR POLYNOMIAL

  • Chanam, Barchand;Reingachan, N.;Devi, Khangembam Babina;Devi, Maisnam Triveni;Krishnadas, Kshetrimayum
    • Nonlinear Functional Analysis and Applications
    • /
    • 제26권2호
    • /
    • pp.331-345
    • /
    • 2021
  • Let p(z)be a polynomial of degree n. Then Bernstein's inequality [12,18] is $${\max\limits_{{\mid}z{\mid}=1}}\;{\mid}p^{\prime}(z){\mid}\;{\leq}\;n\;{\max_{{\mid}z{\mid}=1}{\mid}(z){\mid}}$$. For q > 0, we denote $${\parallel}p{\parallel}_q=\{{\frac{1}{2{\pi}}}{\normalsize\displaystyle\smashmargin{2}{\int\nolimits_{0}}^{2{\pi}}}\;{\mid}p(e^{i{\theta}}){\mid}^qd{\theta}\}^{\frac{1}{q}}$$, and a well-known fact from analysis [17] gives $${{\lim_{q{\rightarrow}{{\infty}}}}\{{\frac{1}{2{\pi}}}{\normalsize\displaystyle\smashmargin{2}{\int\nolimits_{0}}^{2{\pi}}}\;{\mid}p(e^{i{\theta}}){\mid}^qd{\theta}\}^{\frac{1}{q}}={\max\limits_{{\mid}z{\mid}=1}}\;{\mid}p(z){\mid}$$. Above Bernstein's inequality was extended by Zygmund [19] into Lq norm by proving ║p'║q ≤ n║p║q, q ≥ 1. Let p(z) = a0 + ∑n𝜈=𝜇 a𝜈z𝜈, 1 ≤ 𝜇 ≤ n, be a polynomial of degree n having no zero in |z| < k, k ≥ 1. Then for 0 < r ≤ R ≤ k, Aziz and Zargar [4] proved $${\max\limits_{{\mid}z{\mid}=R}}\;{\mid}p^{\prime}(z){\mid}\;{\leq}\;{\frac{nR^{{\mu}-1}(R^{\mu}+k^{\mu})^{{\frac{n}{\mu}}-1}}{(r^{\mu}+k^{\mu})^{\frac{n}{\mu}}}\;{\max\limits_{{\mid}z{\mid}=r}}\;{\mid}p(z){\mid}}$$. In this paper, we obtain the Lq version of the above inequality for q > 0. Further, we extend a result of Aziz and Shah [3] into Lq analogue for q > 0. Our results not only extend some known polynomial inequalities, but also reduce to some interesting results as particular cases.

선반작업(旋盤作業)에서의 FFT Analyzer에 의한 표면(表面)거칠기 해석(解析) (Analysis of Surface Roughness by FFT Analyzer in Turning Operation)

  • 김경연;최은순
    • 비파괴검사학회지
    • /
    • 제12권3호
    • /
    • pp.12-19
    • /
    • 1992
  • This paper shows that the identified and unidentified components of surface roughness in NC turning lathe which can not be analyzed in time domain such as $R_{max},\;R_a$ can be isolated in frequency domain by FFT analyzer. By interfacing FFT analyzer with stylus surface roughness instrument, surface roughness on change of working condition, especially tool feed, such as 0.1, 0.15, 0.2, 0.25, 0.3(mm/rev) can be analyzed in frequency domain as follows. 1. By frequency analysis of surface roughness profile, the basic wave length of surface roughness can be obtained to isolate the identified and unidentified components of surface roughness. 2. With increase of tool feed, the unidentified components of surface roughness increase. 3. Since $R_{max}$, which can be obtained by stylus surface roughness is proportion to the output voltage of FFT analyzer, FFT analyzer also can be used to measure surface roughness in time domain such $R_a,\;R_{max}$.

  • PDF

250 km/h급 강체전차선로 설계파라미터 제시 (A Propose of Design Parameters for the Max. Speed of 250 km/h of Overhead Rigid Conductor System)

  • 이기원;조용현
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.740-744
    • /
    • 2017
  • Overhead Line is divided by two systems which are OCS (Overhead Catenary Line) and R-Bar (Overhead Rigid Conductor system). R-Bar has an advantage of maintenance and economic aspect comparing with OCS. R-Bar in Korea has developed for the max. speed of 120km/h, but it is evaluated up to the max. speed of 250 km/h in Europe. There are lots of mountains and underground sections in korea, it is really necessary to develop the R-Bar for a high-speed line. In the study, design parameters for the max. speed of 250 km/h of R-Bar was proposed. A bracket space, stiffness, and especially an installation tolerance of contact wire height at a bracket were considered as a parameter, and a dynamic behavior between a contact wire and pantograph was predicted by evaluated FEM simulation tool. The installation tolerance and bracket space are more important for the high-speed system. The proposed parameters was decided very conservative. Because the aerodynamic characteristics of a pantograph in tunnel is more severe than an open route and the simulation tool is not considered the such kind of aerodynamic characteristics.