• Title/Summary/Keyword: $PaO_2$

Search Result 513, Processing Time 0.037 seconds

The Effect of Chest Physiotherapy on the Amount of Tracheal Secretion and $PaO_2$ (흉부물리요법이 기관 분비물량과 동맥혈 산소분압에 미치는 영향)

  • Jun Seong-Sook;Moon Mi-Jin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.355-365
    • /
    • 2000
  • The purpose of this research was to find out the effect of chest physiotherapy on the amount of tracheal secretion and $PaO_2$. After changing position of the neurosurgical patients who had tracheostomy cannula, experimental treatments were applied as bellows, manual chest percussion on groupI, chest percussion and manual chest vibration on groupII, chest percussion and mechanical chest vibration on groupIII were done. After these trials, we have analyzed the efficacy of each procedures comparing the group differences in the quantity of tracheal secretion and $PaO_2$. Target samples were sixty patients aged between 20 to 60 who have tracheostomy state and decreased consciousness status that were admitted in NICU of a university hospital from June 1 to August 31, 1999. They assigned randomly into three experimental groups. To compare the effect of each interventions, tracheal secretion quantify was measured and $PaO_2$ was analyzed via arterial blood gas analyzer. The data were analyzed by ANCOVA of 5% significance level using SPSS P/C program. The results were as bellows. 1) The first hypothesis 'There is a difference In the quantify of the secretion among GroupI, GroupII and GroupIII' was accepted.(F=29.27, p=0.00) 2) The second hypothesis 'There is a difference in $PaO_2$ among GroupI, GroupII and GroupIII' was rejected.(F=1.71, p=0.19) From this study results, positional change and manual chest vibration including chest percussion were the most effective treatment to get maximum amount of tracheal secretion and it was confirmed that mechanical chest vibration also made much better effect than sole chest percussion method. Therefore, we concluded that the mechanical or manual chest vibration with chest percussion is more effective respiratory care method than the sole chest percussion.

  • PDF

Effects of Annealing of Al2O3 Layer on Passivation Properties by Plasma Assisted Atomic Layer Deposition

  • Song, Se-Yeong;Jang, Hyo-Sik;Song, Hui-Eun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.689-689
    • /
    • 2013
  • Atomic layer deposition (ALD)에 의한 알루미늄 산화 막(Al2O3)은 고효율 결정질 실리콘 태양전지를 위한 우수한 표면 패시베이션 특성을 제공한다. 알루미늄 산화막는 고정적인 음전하를 가지고 있기 때문에 p-형 실리콘 태양 전지 후면은 전계에 의한 우수한 패시베이션 효과를 형성한다. 그러나, ALD 방식으로 증착된 알루미늄 산화막은 매우 긴 공정 시간을 필요로 하기 때문에 기존의 실리콘 태양 전지 공정에 적용하기가 어렵다. 본 논문에서는 알루미늄 산화막 형성에서 공정 시간을 줄이기 위해 Plasma assisted atomic layer deposition (PA-ALD) 방식을 적용했다. PA-ALD 기술은 trimethylaluminum (TMA)과 O2를 사용하여 기판 표면에 알루미늄 산화막을 증착하는 것으로 ALD 방식과 유사하지만, O2 플라즈마를 사용함으로써 증착 속도를 향상시킬 수 있다. 이는 좋은 패시베이션 특성을 가지는 알루미늄 산화막을 실리콘 태양전지양산 공정에 적용할 수 있는 가능성을 제시한다. PA-ALD 방식에 의한 알루미늄 산화막의 패시베이션 특성을 최적화하기 위해서 증착 후 열처리 조건에 대한 연구도 수행하였다. 막증착률이 1.1${\AA}$/cycle인 Al2O3층의 두께 변화에 따른 특성을 최적화하기 위해 공정 온도를 $250^{\circ}C$ 고정하고, 열처리 온도와 시간을 가변하였으며 유효 반송자수명을 측정하여 알루미늄 산화막의 패시베이션 특성을 확인했다.

  • PDF

Preparation of Liquid Crystal Emulsion for Transdermal Delivery of Glycyrrhizic Acid and Physical Characteristics and In Vitro Skin Permeation Studies (글리시리직애씨드의 경피 전달을 위한 액정 에멀젼의 제조와 물리적 특성 및 In Vitro 피부투과 연구)

  • Jung, Jin Woo;Yoo, Cha Young;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.4
    • /
    • pp.315-324
    • /
    • 2015
  • In this study, we prepared liquid crystal emulsion composed of amphiphilic substance $C_{14-22}$ alcohol, $C_{12-20}$ alkyl glucoside, behenyl alcohol and studied liquid crystal emulsion of properties and in vitro skin permeation. The results of formulation experiments, the clear liquid crystalline structure was observed in the ratio of $C_{14-22}$ alcohol 0.8%, $C_{12-20}$ alkyl glucoside 3.2%, behenyl alcohol 4% in the formulation. The results of physical property measurements, the viscosity of liquid crystal emulsion and O/W emulsion applied as a control group was respectively $1871.26{\sim}1.15Pa{\cdot}s$, $1768.69{\sim}1.14Pa{\cdot}s$ and the shear stress of O/W emulsion was 178.68 ~ 909.18 Pa, that of liquid crystal emulsion was 190.45 ~ 919.38 Pa. The storage modulus of O/W emulsion was 3428.53 ~ 9157.45 Pa, that of liquid crystal emulsion was 4487.82 ~ 8195.59 Pa. The tan (delta) value of O/W emulsion which means a ratio of viscosity to elasticity was 0.43 ~ 0.19, and that of liquid crystal emulsion was 0.23 ~ 0.25. The water content value on the skin for liquid crystal emulsion was significantly higher from 1 h to 6 h compared with that of O/W emulsion and the transepidermal water loss on the skin was significantly superior in skin moisture loss suppression from 30 min to 4 h compared with that of O/W emulsion. The results of skin permeation using glycyrrhizic acid, the result of skin permeation amount of liquid crystal emulsion for 24 h was $64.58{\mu}g/cm^2$, that of O/W emulsion was $37.07{\mu}g/cm^2$, that of butylene glycol solution was $41.05{\mu}g/cm^2$. Hourly permeability results, it is showed that skin penetration effect of the liquid crystal emulsion increases after 8 h. These results suggest that liquid crystal emulsions are effective for skin moisturizing effect and function as potential efficacy ingredient delivery system for the transdermal delivery.

The use of Thermodynamics and Phase Equilibria for Prediction of the Behavior of High Temperature Corrosion of Alloy 617 in Impure Helium Environment

  • Kim, Dong-Jin;Lee, Gyeong-Geun;Kim, Sung-Woo;Kim, Hong-Pyo
    • Corrosion Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.164-170
    • /
    • 2010
  • Thermodynamic consideration was performed for Alloy 617 exposed to an impure helium ($H_2$ 20pa, $H_2O$ 0.5pa, $CH_4$ 2pa and CO 5pa) at $950^{\circ}C$. Oxidation power was decreased in the order Al > Ti > Si > Cr > Mn. Decarburization and carburization reactions were available leading to carbon activity decrease and increase, respectively, depending on carbon and Cr activities. The thermodynamic prediction was compared with the experimental results obtained in similar conditions (($H_2$ 20pa, $H_2O$ 0.05pa, $CH_4$ 5pa and CO 2pa) and $950^{\circ}C$) by others for Alloy 617. The driving force for oxidation of Al, Ti and Si is very large to be oxidized at a given impure helium and the environment is actually carburizing towards the structural alloy, which is consistent with this work.

Multimode fiber-optic pressure sensor based on dielectric diaphragm (유전체 다이아프램을 이용한 다모드 광섬유 압력센서)

  • 김명규;권대혁;김진섭;박재희;이정희;손병기
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.3
    • /
    • pp.220-226
    • /
    • 1997
  • An optical intensity-type pressure sensor has been fabricated by coupling multimode optical fiber with 100 nm-Au/30 nm-NiCr/150 nm-$Si_3N_4/300 nm-SiO_2/150 nm-Si_3N_4$ optical reflection layer supported by micromachined frame-shape silicon substrate, and its characteristics was investigated. For the application of $Si_3N_4/SiO_2/Si_3N_4$ diaphragm to the optical reflection layer of the sensor, NiCr and Au films were deposited on the backside of the diaphragm by thermal evaporation , respectively, and thus optical low caused by transmission in the reflection layer could be decreased to a few percents. Dielectric diaphragms with uniform thickness were able to be also reproduced because top- and bottom-$Si_3N_4$ layer of the diaphragm could automatically stop silicon anisotropic etching. The respective pressure ranges in which the sensor showed linear optical output power-pressure characteristics were 0~126.64 kPa, 0~79. 98 kPa, and 0~46.66 kPa, and the respective pressure sensitivities of the sensor were about 20.69 nW/kPa, 26.70 nW/kPa, and 39.33 nW/kPa, for the diaphragm sizes of 3$\times$3 $\textrm{mm}^2$, 4$\times$4 $\textrm{mm}^2$, and 5$\times$5 $\textrm{mm}^2$, indicating that the sensitivity increases as diaphragm size increases.

  • PDF

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

The Impact of Different Endotracheal Suction Methods on Respiratory Function: Normal Saline with Chest Vibration vs Normal Saline with Expectorant Mixture (기관내 흡인방법에 따른 호흡기능의 차이)

  • Cho, Hyo-Im;Lee, Young-Whee;Ham, Ok-Kyung;Lim, Ji-Young
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.2
    • /
    • pp.209-218
    • /
    • 2008
  • Purpose: Regarding the respiratory function of patients with an artificial airway, this study compared the effects between normal saline with chest vibration and normal saline with expectorant mixture, administered before endotracheal suction. Methods: The study was conducted in the ICUs of one university hospital located in Incheon. The experimental group I received normal saline with chest vibration administered before endotracheal suction while the experimental group II received normal saline with expectorant mixture administered before endotracheal suction. For respiratory function, $PaO_2$, $PaCO_2$, and $O_2$ saturation were measured by ABGA at 3 minutes after endotracheal suction for both pre-test and post-test. Results: The two groups were not different significantly regarding $PaO_2$ level and $O_2$ saturation after the treatments, while, the experimental group II had lower $PaCO_2$ level than the experimental group I after the treatments (t = 2.075, p = .042). For experimental group II, post-test score of $PaCO_2$ level was significantly lower than that of the pre-test score (t = 1.842, p = .075). Conclusion: The administration of normal saline with expectorant mixture before endotracheal suction reduced $PaCO_2$ level and improved the respiratory function.

  • PDF

The Effect of Residual H2Pressure on Gallium-doped ZnO Films Deposited by Magnetron Sputtering (마그네트론 스퍼터링에 의해 제작한 Gallium-doped ZnO 박막에 있어서 잔류 H2O 분압의 영향)

  • Song, Pung-Keun;Kwon, Young-Jun;Cha, Jae-Min;Lee, Byung-Chul;Ryu, Bong-Ki;Kim, Kwang-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.928-934
    • /
    • 2002
  • Gallium doped Zinc Oxide(GZO) films were deposited by dc magnetron sputtering using a GZO ceramic target at various conditions such as substrate temperature (RT, 400), residual water pressure ($P_{H_2O}$; 1.61${\times}10^{-4}∼2.2{\times}10^{-3}$ Pa), introduction of $H_2$ gas (8.5%) and different magnetic field strengths(250, 1000G). GZO films deposited without substrate heating showed clear degradation in film crystallinity and electrical properties with increasing $P_{H_2O}$. The resistivity increased from 3.0${\times}10^{-3}$ to 3.1${\times}10^{-2}{\Omega}㎝$ and the grain size of the films decreased from 24 to 3 nm when PH2O was increased from 1.61${\times}10^{-4}$ to 2.2${\times}10^{-3}$ Pa. However, degradation in electrical properties with increasing $P_{H_2O}$ was not observed for the films deposited with introduction of 8.5% $H_2$. When magnetic field strength of the cathode increased from 250G to 1000G, crystallinity and electrical properties of GZO films improved remarkably about all the $P_{H_2O}$. This result could be attributed to the decrease in film damage caused by the decrease in plasma impedance.

Quality Changes in 'Elliot' Blueberries and 'Sulhyang' Strawberries Packed with Two Different Packaging Materials during Refrigerated Storage (기체투과도가 다른 포장재로 포장한 '엘리오트' 블루베리와 '설향' 딸기의 냉장 저장 중 품질 변화)

  • Jung, Seung Hun;Kang, Ji Hoon;Park, Seung Jong;Seong, Ki Hyun;Song, Kyung Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.901-908
    • /
    • 2014
  • Blueberries and strawberries are highly perishable and easily contaminated with microorganisms. To maintain the quality of these commodities during refrigerated storage, the effects of two packaging materials as well as passive modified atmosphere packaging on the quality of blueberries and strawberries were investigated. The harvested blueberries and strawberries were first treated with combined non-thermal treatment of aqueous chlorine dioxide and fumaric acid, followed by packaging with polyolefin film (6,000 mL $O_2/m^2{\cdot}24hr{\cdot}atm$ at $24^{\circ}C$) and polyamide/polyamide/polyethylene film (PA/PA/PE, 60 mL $O_2/m^2{\cdot}24hr{\cdot}atm$ at $24^{\circ}C$), respectively. After combined sanitizer treatment, the populations of total aerobic bacteria in blueberries and strawberries were reduced by 2.50 and 1.97 log CFU/g while those of yeast and molds were reduced by 1.95 and 2.18 log CFU/g, respectively, compared with the control. In particular, microbial growth in these samples packed with PA/PA/PE film was reduced during refrigerated storage. In addition, the blueberries and strawberries packed with PA/PA/PE film underwent lower weight loss than those packed with polyolefin film during storage. These results suggest that appropriate packaging with proper gas permeability is necessary to maintain the quality of blueberries and strawberries during refrigerated storage.

결정질 실리콘 태양전지 적용을 위해 PA-ALD를 이용한 $Al_2O_3$ 최적화 연구

  • Song, Se-Yeong;Gang, Min-Gu;Song, Hui-Eun;Jang, Hyo-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.246-246
    • /
    • 2013
  • Atomic layer deposition (ALD)에 의해 증착된 알루미늄 산화막($Al_2O_3$)은 고효율 결정질 실리콘 태양전지를 위한 우수한 패시베이션 효과를 보인다. $Al_2O_3$은 고정 음전하를 가지고 있기때문에 p-형 태양전지 후면에서 field effect passivation에 의한 효과적인 표면 패시베이션을 형성한다. 하지만 ALD에 의한 $Al_2O_3$ 증착은 긴 공정시간이 필요하다. 이는 기존의 태양전지 산업에 적합하지 않다. 본 논문에서는 공정 시간의 단축을 위해 plasma-assisted atomic layer deposition (PA-ALD) 기술을 사용함으로서 $Al_2O_3$을 증착했다. PA-ALD 기술은 trimethyaluminum (TMA)와 plasma 분위기에서의 $O_2$ 가스를 사용하여 표면 반응을 한다. $Al_2O_3$ 층의 특성을 최적화하기 위해 증착 온도를 $150{\sim}250^{\circ}C$의 범위에서 가변하고, 열처리 온도와 시간을 변화하였다. 결과적으로, 실리콘 웨이퍼를 이용하여 $1250^{\circ}C$의 공정온도에서 증착한 $Al_2O_3$$400^{\circ}C$에서 10분 동안의 열처리 온도와 시간에서 1,610 ${\mu}s$의 최고의 유효 반송자 수명을 보였다.

  • PDF