• Title/Summary/Keyword: $PM_{10}$ mass

Search Result 1,358, Processing Time 0.027 seconds

A Study of Upper Airway Resistance Syndrome : Clinical and Polysomnographic Characteristics (상기도저항 증후군에 대한 연구 : 임상 및 수면다원검사 특징)

  • Yang, Chang-Kook;Clerk, Alex
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • Objectives : Upper airway resistance syndrome(UARS) is a sleep-related breathing disorder characterized by abnormal negative intrathoracic pressure during sleep. Abnormally increased negative intrathoracic pressure results in microarousal and sleep fragmentation which underlay UARS-associated complaints of daytime fatigue and sleepiness. Although daytime dysfunction in patients with UARS is comparable to that of sleep apnea syndrome, UARS has been relatively unnoticed in clinical setting. That is why UARS is apt to be excluded in diagnosing of sleep-related breathing disorders since its respiratory disturbance index and arterial oxygen saturation are within normal limits. The current study presents a summary of clinical and polysomnographic characteristics found in patients with UARS. The present study aims (1) to explore characteristics of patients diagnosed with UARS, (2) to characterize the polysomnographic findings of UARS patients, and (3) to enhance the understanding of UARS through those clinical and laboratory characteristics. Methods : This was a retrospective study of 20 UARS patients (male 15, female 5) and 30 obstructive sleep apnea (OSA) patients (male 21, female 9) at the Stanford Sleep Disorders Clinic. We diagnosed patients as having UARS when they met critenia, RDI < 5 characteristic findings of an elevated esophageal pressure($<-10\;cmH_2O$), frequent arousals secondary to an elevated esophageal pressure, and symptoms of daytime fatigue and sleepiness. We used polysomnographic value, which is standardized by Williams et al(1974), as normal control. Statiotical test were done with student t-tests. Results : (1) Mean age of UARS was $41.0\;{\pm}\;14.8$ years and OSA was $50.9\;{\pm}\;12.0$ years. UARS subject was significantly younger than OSA subject (p<0.05). (2) The total score of Epworth Sleepiness Scale (ESS) was UARS $9.7\;{\pm}\;6.3$ and OSAS $11.2\;{\pm}\;6.3$. There was no significant difference between two groups. (3) The mean body mass index was UARS $28.1\;{\pm}\;5.7\;kg/m^2$ and OSAS $32.9\;{\pm}\;7.0\;kg/m^2$. UARS had significantly lower meen body man index than OSAS subjects (p<0.05). (4) The polysomnographic parameters of UARS were not significantly different from those of OSA except RDI(p<0.001), $SaO_2$ (p<0.001) and slow wave sleep latency (p<0.05). (5) Compared with normal control, Total sleep time in UARS subjects was significantly shorter (p<0.001), sleep efficiency index was significantly lower (p<0.001), total awakening percentage was significantly higher (p<0.001), and sleep stage 1 (p<0.001) were significantly higher. (6) OSA patients showed poor sleep quality and distinct abnormal sleep architectures compared with normal control. Conclusions : Conclusions from the above results are as follows : (1) UARS patients were younger and had lower body mass index when umpared with OSA patients. (2) The quality of sleep and sleep architectures of the UARS and OSA patients are significantly different from those of normal control. (3) ESS scores and awakening frequencies of UARS are similar with those of OSA, suggesting that daytime dysfunction of UARS patients may be comparable to those of OSA patients. (4) The RDI and the $SaO_2$ which are important indicators in diagnosing sleep-related breathing disorders, of UARS subjects are close to normal value. (5) According to the the above results, we unclude that despite the absence of $SaO_2$ drops and the absence of an elevated number of apnea and hypopnea, subjects developed clinical complaints which were associated with laborious breathing, elevated Pes nadir, and frequently snoring. (6) Accordingly, we suggest including LIARS in the differential diagnosis list when sleep related breathing disorder is suspected clinically and overnight polysomnographic findings except snoring and frequent microarousal are within normal limits.

  • PDF

Obesity Estimation of Abdominal Fat by Using Computed Tomography : Influence of Breathing Motion on The Fat Measurement (전산화단층영상을 이용한 복부 지방 계측법에서 호흡운동이 비만도 측정에 미치는 영향)

  • Seoung, Youl-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • The purpose of this study was to evaluate how much effect to accuracy when measuring abdominal fat by Computed Tomography (CT) under different respiration movements. The study volunteer composed of 66 normal adults ($50.4{\pm}11.2$ years, 33 males, 33 females). We measured their obesity by using Broca index, body mass index (BMI) and CT and have investigated the correlation. The CT scanning for the obesity measurement have done in two ways, one was done in stopping breath after exhaling and the other was holding a breath after inhaling. The results showed no statistically significant difference among the three measuring techniques. And, the error in two ways of inhaling and exhaling was showed 24.2% of volunteers. The two ways of respiration movements made different result in visceral fat area (P = 0.044), subcutaneous fat area (P = 0.636) and abdominal obesity value (P = 0.012). This study demonstrates that the two ways of respiration movements when scanning CT makes change in accuracy in visceral fat area, and in abdominal obesity quantitative measure. Therefore, our study suggests that CT should take twice in two ways while a patient stops breath after exhaling and holds a breath after inhaling when measuring abdominal obesity using CT equipments.

Design of a Rectangular-Type Voice Coil Actuator for Frame Vibration Compensation

  • Choi, Young-Man;Ahn, Dahoon;Gweon, Dae-Gab;Lee, Moon Gu
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.348-355
    • /
    • 2016
  • Precision motion stages used in the manufacturing process of flat-panel displays have inevitably low settling performance due to their huge mass and bulky structures. In order to improve the settling performance, several methods of frame vibration compensation have been developed so far. These methods are used to cancel the vibration by imposing a counter force or modifying the resonance mode of the frame of the stage. To compensate the frame vibration, high force actuators are required. In this paper, a mighty voice coil actuator is proposed to generate the counter force against the frame vibration. The proposed voice coil actuator has an axis-symmetric rectangular structure to achieve a large force with simple and low cost fabrication. Also, the voice coil actuator allows radial clearance up to ${\pm}4mm$. Using an optimized design process and a magnetic circuit model, the power consumption is minimized while the required force is obtained. With a power of 322 W, the VCA has been designed to have a maximum force of 574 N with a force constant of 164 N/A. Experimental results verified the force constant of the fabricated voice coil actuator is well matched with the designed value.

Numerical Design of Light-off Auto-Catalyst for Reducing Cold-Start Emissions (냉간시동시 자동차용 저온활성촉매의 성능 향상을 위한 수치적 설계)

  • Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1264-1276
    • /
    • 2000
  • Light-off catalyst has been used for minimization of cold-start emissions. Improved cold-start performance of light-off catalyst needs the optimal design in terms of flow distribution, geometric surface area, precious metal loading, cell density and space velocity. In this study, these influential factors are numerically investigated using integrated numerical technique by considering not only 3-D fluid flow but also heat and mass transfer with chemical reactions. The present results indicate that uneven catalyst loading of depositing high active catalyst at upstream of monolith is beneficial during warm-up period but its effect is severely deteriorated when the space velocity is above 100,000 $hr^{-1}$ To maximize light-off performance, this study suggests that 1) a light-off catalyst be designed double substrate type; 2) the substrate with high GSA and high PM loading at face be placed at the front monolith; and 3) the cell density of the rear monolith be lower to reduce the pressure drop.

Estimation of the Light Absorption Contribution for Asian Dust and Polluted Particles at Gosan, Jeju during the Asian Dust Episode in the Spring 2011 (2011년 봄 황사시기 제주도 고산에서의 황사와 오염입자의 광흡수 기여도 산정)

  • Lee, Si-Hye;Kim, Sang-Woo;Yoon, Soon-Chang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.411-422
    • /
    • 2012
  • Ground-based in-situ measurements of aerosol optical properties at Gosan climate observatory have been analyzed to investigate the optical contribution of Asian dust and polluted particles on light absorption in springtime 2011. During the Asian dust episode, the contribution of Asian dust particle to aerosol absorption coefficient estimated about 45% at 370 nm and about 23% at 520 nm. Especially, black carbon in dust plume contributes about 48% to aerosol light absorption at 520 nm since the airmass are transported from the Gobi and inner Mongolia deserts, and this airmass comes across the northeastern coast of China, near the Shandong Peninsula. In pollution case, the contributions of dust particle and black carbon to aerosol absorption coefficient estimated about 41% and 11% at 370 nm, respectively. However, pollution case shows the highest light absorption of 48% for brown carbon at 370 nm, which indicates the significantly high mass concentration of organic carbon ($6.3{\pm}2.2{\mu}g\;m^{-3}$) in pollution plume can contribute to the increase of light absorption at near-UV spectral region.

Kinetic Analysis of Three-Point Jump Shot in Basketball (농구 3득점 점프슛 동작의 운동역학적 분석)

  • Lee, Dong-Jin;Jeong, Ik-Su
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.49-55
    • /
    • 2010
  • The purpose of the study was to analyze kinetic factors required to the three-point jump shot of the basketball games through 3-D analysis and ground reaction force(GRF) analysis. Six university male players participated in this study. The results of the study were showed that (1) resultant velocity in the center of mass(COM) was $0.84{\pm}0.27\;m/s$ since a player didn't shot a ball in the highest peak and shot ball at the moment of going up forward and vertical movement. Therefore, it is necessary to find a proper timing to shot a ball; (2) the angular velocity was largely increased in upper arm and fore arm out of the upper-limb segments and the hands had the largest angular velocity since the body is in a fixed situation and angular speed is rapidly increased by the wrist' snap with the rapid movement of upper arm and forearm at the time of release a ball; (3) it is judged that a player can shot a ball at the accurate and high release point when the player collects power vertically to the maximum by keeping GRF to the right and the rear in a proper way and by keeping the body's balance so that a large power may not be dispersed.

Effects of solar variations on standing Alfven waves in the dayside magnetosphere: Polar observations

  • Kim, Khan-Hyuk;Takahashi, Kazue
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.23.4-23.4
    • /
    • 2008
  • In March and April 2001, the apogee (~9 Re) of the Polar spacecraft was located near the subsolar magnetopause with its orbital plane nearly parallel to a magnetic meridian plane. Polar electric and magnetic field data acquired during the two-month interval of solar maximum have been used to study fundamental standing Alfven waves near the subsolar meridian plane (magnetic local time = 1000-1400 hours) at magnetic latitudes from the equator to $\pm45$ degrees and at L values between 7 and 12. In the frequency band from 1.5 to 10 mHz, fundamental mode oscillations were identified based on high coherence (more than 0.7) and an approximately 90-degree phase shift between the azimuthal magnetic and radial electric field components. The L dependence of the fundamental frequencies is studied, and the frequencies are compared with those observed near the solar minimum interval (Takahashi et al. 2001). We found that the average frequencies in solar maximum are lower than those in solar minimum by a factor of ~2. This implies that the mass density in solar maximum is higher than that in solar minimum by a factor of ~4. Since there is a positive correlation between solar irradiance and solar activity, we suggest that the ionosphere in solar maximum produces more ions and load magnetic flux tubes with more ions.

  • PDF

Effects of Nutrition Education on Nutritional Status of Hemodialysis Patients (영양교육이 혈액투석환자의 영양상태에 미치는 효과)

  • 양정례;서혜정;김양하
    • Journal of Nutrition and Health
    • /
    • v.36 no.7
    • /
    • pp.749-758
    • /
    • 2003
  • Malnutrition is a common problem in patients undergoing maintenance hemodialysis (HD) and compromised food intake is an important cause. Malnutrition is one of the important factors influencing mortality in these patients. This study was conducted to evaluate the effectiveness of nutrition education at improving nutritional status of 23 Korean HD patients (mean : 48.6 $\pm$ 10.4 years, men : 8, women : 15). Anthropometric indices, nutrient intakes, and biochemical blood indices were measured before and after a 6-month nutrition education intervention. Anthropometric indices such as percent ideal body weight [PIBW (%)], body fat, body mass index (BMI), mid-arm circumference (MAC), mid-arm muscle circumference (MAMC), and calculated arm muscle area (CAMA) of subjects were within the normal range and not changed by nutrition education. Subjective global assessment (SGA) was significantly increased (p < 0.05) after nutrition education. Intake of total energy, carbohydrate, lipid, Ca, and vitamin B1 was increased significantly (p < 0.05) but intake of phosphorus, potassium, and sodium was decreased (p < 0.05). The serum concentrations of albumin, total protein, and Ca were significantly increased (p < 0.05), but levels of P and K were decreased (p < 0.05) after the intervention. These findings suggest that nutrition education for HD patients can be effective for positively changing nutrient intakes, leading to improvements in blood indices and nutritional status.

Comparative Analysis of Surface-mounted and Interior Permanent Magnet Synchronous Motor (표면부착형 / 매입형 영구자석 동기 전동기의 비교 분석)

  • Park, Hyung-Il;Kim, Kwan-Ho;Shin, Kyung-Hun;Jang, Seok-Myeong;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.987-994
    • /
    • 2016
  • In this paper, we present a comparative analysis of surface-mounted permanent magnet synchronous motors (SPMSM) and interior permanent magnet synchronous motors (IPMSM). First, we use 2D finite element analysis (FEA) to analyze models satisfying the same rated conditions according to the torque-speed curve characteristics, which are determined from the operating conditions. Next, we manufacture an SPMSM and IPMSM having good performances from an electromagnetic perspective based on analysis results, namely the cogging torque, torque ripple, and efficiency. We analyze both of the manufactured machines when they are connected back-to-back and when they are used as a motor and a generator, respectively. The motor is driven by a commercial inverter and the generator is connected to a three-phase resistance load bank. Finally, based on experimental results, which include the total harmonic distortion (THD) of the back electro-motive force (EMF), cogging torque, efficiency, and mass, we determine the motor that is most suitable under requirements.

An Experimental Study on Pressure Drop of Boiling Flow within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로 내에서의 비등 유동 압력강하에 관한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1219-1226
    • /
    • 2001
  • Pressure drops were measured for the flow boiling process within horizontal rectangular channels. The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated up to 15kW/㎡. The quality range covers from 0.15 to 0.75. The present experimental conditions coincide with the operating conditions of compact heat exchangers in which the liquid and gas flows are laminar and turbulent. The measured results were well represented by the two-phase frictional multiplier of Lee (2001) which has been developed for air-water two-phase flows within the deviation of $\pm$20%.