• 제목/요약/키워드: $PM_{10}$ mass

검색결과 1,357건 처리시간 0.027초

국내공정시험기준과 ISO 방법을 이용한 고정오염원 미세먼지 (PM10, PM2.5) 측정 방법 및 입경분율 비교: 석탄화력발전소, 석유정제시설 중심으로 (Comparison of Measurement Methods and Size Fraction of Fine Particles (PM10, PM2.5) from Stationary Emission Source Using Korean Standard and ISO: Coal Power Plant and Refinery)

  • 윤종상;한세현;정용원;전기준
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.342-350
    • /
    • 2017
  • We report mass concentration and size fraction of TPM, $PM_{10}$ and $PM_{2.5}$ according to Korea standard test method (ES 01301.1 and ES 01317.1) and ISO 23210 methods. Particulate matters were sampled in large stationary emission sources such as a coal power plant and B-C oil refinery. The Korea standard test method PM mass concentrations showed 3~3.5 times larger than the cascade impactor method. On the other hand, the size fraction results showed less than 5% difference (i.e. $PM_{2.5}/PM_{10}$) between two methods. Moreover, the correlation coefficient ($r^2$) is 0.84 between TPM results of the Korea standard test method and CleanSYS. These results suggested not only improvement of current test criteria in terms of technical and theoretical aspects. Further, additional measurements are required in various large stationary sources to compare current field data.

미국 St. Louis Supersite에서의 준 실시간 PM2.5에 대한 기여도 추정 및 지역 규모 오염원의 위치 파악 (Estimation of Source Apportionment for Semi-Continuous PM2.5 and Identification of Location for Local Point Sources at the St. Louis Supersite, USA)

  • 황인조
    • 한국대기환경학회지
    • /
    • 제25권2호
    • /
    • pp.154-166
    • /
    • 2009
  • In this study, 1-hour integrated $PM_{2.5}$ mass and chemical composition concentrations were monitored at the St. Louis-Midwest Supersite in Illinois. Time-resolved samples were collected one week in each of June 2001 (22 June to 28 June), November 2001 (7 November to 13 November), and March 2002 (19 March to 25 March). A total of 427 samples were collected by CAMM (continuous ambient mass monitor) and 15 compounds were analyzed by AAS, PILS (particle-into-liquid sampler), and TOT (thermal optical transmittance) method. PMF was applied to identify the sources and apportion the $PM_{2.5}$ mass to each source for highly time resolved data. In addition, the nonparametric regression (NPR) was applied to identify the predominant directions of local sources relative to wind direction. Also, this study performed compare the NPR analysis and location of actual local point sources at the St. Louis area. The PMF modeling identified nine sources and the average mass was apportioned to gasoline vehicle, road dust, zinc smelter, copper production, secondary sulfate, diesel emission, secondary nitrate, iron+steel, and lead smelter, respectively. These results suggested that this study results will be help for $PM_{2.5}$ source apportionment studies at similar metropolitan area, establish $PM_{2.5}$ standard, and establish effective emissions reduction strategies in Korea.

유방 종괴에서 악성 감별을 위한 유방촬영술과 유방스캔의 유용성 연구 (The Usefulness of Mammography and Scintimammography in Differential Diagnosis of Breast Tumor)

  • 강봉주;정용안;정현석;정정임;유이령;김성훈;손형선;정수교;한성태;이재문
    • 대한핵의학회지
    • /
    • 제38권6호
    • /
    • pp.492-497
    • /
    • 2004
  • 목적: 여성에게 많이 발생되는 유방 종괴의 악성여부의 판단은 매우 중요하다. 기존의 여러 영상진단법으로도 유방 종괴의 악성여부를 구분하기가 어려운 경우가 많아 이에 대한 연구는 매우 많다. 이에 저자들은 유방 종괴의 악성여부를 평가하는데 많이 사용되고 있는 유방촬영술과 Tc-99m MIBI 유방스캔의 유용성을 알아보고, 조직병리 검사소견과의 연관성에 대해서도 함께 비교하여 보았다. 대상 및 방법: 유방종괴를 갖고 있는 여자 환자 총 80명(나이: 24-72세, 평균: 48.4세)을 대상으로 하였다. 모든 환자에서 유방촬영술과 Tc-99m MIBI 유방스캔을 시행하였다. 방사성동위원소 투여 후 10 분째에 조기 영상, 2시간째 지연 영상을 전면상과 양측면상으로 얻었다. 두 명의 숙련된 방사선과 전문의와 핵의학 전문의가 유방 종괴의 악성여부를 판독하였으며, 유방스캔의 정량적인 분석으로 방사능집적을 보이는 경우 각각의 종괴 대 배후방사능비와 배설율을 구하였다. 모든 종괴에서 조직 병리검사를 시행하였다. 각각에서 얻어진 결과치와 조직검사 결과와의 연관성을 chi-square와 상관분석을 이용하여 통계 분석하였다. 결과: 유방촬영술의 원발성 유방암 진단의 예민도, 특이도, 양성예측율, 음성예측율은 각각 87.5%, 56.3%, 75.0%, 75.0%이었다. 유방스캔에서는 총 80 명의 환자 중 45 명의 환자를 악성 종괴에 의한 방사능집적으로 판단하였다. 이중 41 명이 조직 검사에서 악성으로 판정되었고, 4명이 양성으로 판정되었다. 결과적으로 유방스캔의 예민도, 특이도, 양성예측율, 음성예측율은 각각 85.4%, 87.5%, 91.1%, 80.8%로 측정되었고, 유방촬영술 결과와 비교하여 예민도는 낮았으나 특이도, 양성예측율, 음성예측율은 모두 높았다. 양성 종괴의 종괴 대 배후방사능비는 관심영역의 10 분째 평균치에서 $1.409{\pm}0.30$, 2 시간째에서 $1.267{\pm}0.42$이었고, 10 분째 최대치에서 $1.604{\pm}0.42$, 2 시간째 최대치에서 $1.476{\pm}0.50$이었다. 악성 종괴의 종괴 대 배후방사능비는 10 분째 평균치에서 $2.220{\pm}1.07$, 2 시간째 평균치에서 $1.842{\pm}0.75$이었고, 10 분째 최대치에서 $2.993{\pm}1.94$, 2 시간째 최대치에서 $2.480{\pm}1.34$이었다. 10분과 2시간째의 종괴 대 배후방사능비의 양성과 악성의 차이는 모두 통계적으로 유의하였다. 결론: 유방촬영술은 원발성 유방암의 진단 예민도는 높았으나, 유방 종괴의 악성 여부 판정에 있어서는 Tc-99m MIBI를 이용한 유방스캔이 매우 유용하였다. 특히 종괴 대 배후방사능비를 이용할 경우 유방암의 진단율을 더욱 높힐 수 있었다.

타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성 (Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines)

  • 정은교;장재길;송세욱;김정호
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.

Diffusion Weighted Imaging Can Distinguish Benign from Malignant Mediastinal Tumors and Mass Lesions: Comparison with Positron Emission Tomography

  • Usuda, Katsuo;Maeda, Sumiko;Motono, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Matoba, Munetaka;Watanabe, Naoto;Tonami, Hisao;Ueda, Yoshimichi;Sagawa, Motoyasu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권15호
    • /
    • pp.6469-6475
    • /
    • 2015
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) makes it possible to detect malignant tumors based on the diffusion of water molecules. It is uncertain whether DWI is more useful than positron emission tomography-computed tomography (PET-CT) for distinguishing benign from malignant mediastinal tumors and mass lesions. Materials and Methods: Sixteen malignant mediastinal tumors (thymomas 7, thymic cancers 3, malignant lymphomas 3, malignant germ cell tumors 2, and thymic carcinoid 1) and 12 benign mediastinal tumors or mass lesions were assessed in this study. DWI and PET-CT were performed before biopsy or surgery. Results: The apparent diffusion coefficient (ADC) value ($1.51{\pm}0.46{\times}10^{-3}mm^2/sec$) of malignant mediastinal tumors was significantly lower than that ($2.96{\pm}0.86{\times}10^{-3}mm^2/sec$) of benign mediastinal tumors and mass lesions (P<0.0001). Maximum standardized uptake value (SUVmax) ($11.30{\pm}11.22$) of malignant mediastinal tumors was significantly higher than that ($2.53{\pm}3.92$) of benign mediastinal tumors and mass lesions (P=0.0159). Using the optimal cutoff value (OCV) $2.21{\times}10^{-3}mm^2/sec$ for ADC and 2.93 for SUVmax, the sensitivity (100%) by DWI was not significantly higher than that (93.8%) by PET-CT for malignant mediastinal tumors. The specificity (83.3%) by DWI was not significantly higher than that (66.7%) for benign mediastinal tumors and mass lesions. The accuracy (92.9%) by DWI was not significantly higher than that (82.1%) by PET-CT for mediastinal tumors and mass lesions. Conclusions: There was no significant difference between diagnostic capability of DWI and that of PET-CT for distinguishing mediastinal tumors and mass lesions. DWI is useful in distinguishing benign from malignant mediastinal tumors and mass lesions.

서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발 (Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map)

  • 이은선;박민빈;이태정;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

PMF 모델을 이용한 대기 중 PM-10 오염원의 확인 (Source Identification of Ambient PM-10 Using the PMF Model)

  • 황인조;김동술
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.701-717
    • /
    • 2003
  • The objective of this study was to extensively estimate the air quality trends of the study area by surveying con-centration trends in months or seasons, after analyzing the mass concentration of PM-10 samples and the inorganic lements, ion, and total carbon in PM-10. Also, the study introduced to apply the PMF (Positive Matrix Factoriza-tion) model that is useful when absence of the source profile. Thus the model was thought to be suitable in Korea that often has few information about pollution sources. After obtaining results from the PMF modeling, the existing sources at the study area were qualitatively identified The PM-10 particles collected on quartz fiber filters by a PM-10 high-vol air sampler for 3 years (Mar. 1999∼Dec.2001) in Kyung Hee University. The 25 chemical species (Al, Mn, Ti, V, Cr, Fe, Ni, Cu, Zn, As, Se, Cd, Ba, Ce, Pb, Si, N $a^{#}$, N $H_4$$^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$, C $l^{[-10]}$ , N $O_3$$^{[-10]}$ , S $O_4$$^{2-}$, TC) were analyzed by ICP-AES, IC, and EA after executing proper pre - treatments of each sample filter. The PMF model was intensively applied to estimate the quantitative contribution of air pollution sources based on the chemical information (128 samples and 25 chemical species). Through a case study of the PMF modeling for the PM-10 aerosols. the total of 11 factors were determined. The multiple linear regression analysis between the observed PM-10 mass concentration and the estimated G matrix had been performed following the FPEAK test. Finally the regression analysis provided source profiles (scaled F matrix). So, 11 sources were qualitatively identified, such as secondary aerosol related source, soil related source, waste incineration source, field burning source, fossil fuel combustion source, industry related source, motor vehicle source, oil/coal combustion source, non-ferrous metal source, and aged sea- salt source, respectively.ively.y.

2MASS NEAR-IR COLOR-MAGNITUDE DIAGRAM OF THE OLD OPEN CLUSTER KING 11

  • Kyeong, Jae-Mann;Moon, Hong-Kyu;Kim, Sang-Chul;Sung, Eon-Chang
    • 천문학회지
    • /
    • 제44권1호
    • /
    • pp.33-38
    • /
    • 2011
  • We study near-infrared properties of the old open cluster King 11, based on the 2MASS photometric data. We determine the location of the red giant clump(RGC) in the (K, J - K) colo-magnitude diagram and derive the distance modulus of King 11 to be $(m-M)_0$ = $12.50{\pm}0.10$ using the mean K magnitude of RGC. From the red giant branch slope - [Fe/H] relation we obtain the metallicity of this cluster, [Fe/H]=$-0.17{\pm}0.07$. The age and interstellar reddening of this cluster are estimated to be log t = $9.48{\pm}0.05$, E(B-V)=$0.90{\pm}0.03$, by applying Padova isochrone fits to the data.

정상 성인 남녀의 선 자세에서 비예측적 지지면 이동 시체간 안정성과 균형능력 비교 (Gender Difference in Trunk Stability and Standing Balance during Unexpected Support Surface Translation in Healthy Adults)

  • 김민희;김유신;윤범철
    • The Journal of Korean Physical Therapy
    • /
    • 제26권2호
    • /
    • pp.97-103
    • /
    • 2014
  • Purpose: The aim of this study was to clarify the gender difference during standing balance in accordance with recruitment of abdominal muscles against sudden support surface translation. Methods: Twenty healthy males (n = 10, $26.50{\pm}3.54$ years, $170.60{\pm}6.30cm$, $72.80{\pm}5.69kg$) and females (n = 10, $24.40{\pm}2.63$ years, $163.00{\pm}4.97cm$, $52.10{\pm}4.41kg$) participated in the study. Each subject performed standing balance task on a platform, which moved in the anterior and posterior direction, with a total of 18 trials in three abdominal conditions (resting, hollowing, and bracing). We analyzed angular displacement of thoracic and lumbar spine and linear displacement of center of mass for evaluatione of spinal stability and standing balance, respectively. Results: Angular displacement of thoracic and lumbar spine and linear displacement of center of mass did not differ significantly between female and male in all conditions. Conclusion: Our results indicate that the ability to maintain spinal stability and standing balance were similar between male and female regardless of the abdominal contractile conditions and the direction of support surface translation.

베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법 (Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method)

  • 최훈;손상욱;배현덕
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.