• Title/Summary/Keyword: $NO_x$ Control Device

Search Result 29, Processing Time 0.027 seconds

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process (저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발)

  • Yoo, J.S.;Paek, M.S.;Kim, T.H.;Kim, J.I.;Kim, Y.S.;Choi, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

Fabrication and Characteristics of SAW Gas Sensor (SAW 가스센서의 제작 및 특성)

  • Jun, C.B.;Park, H.D.;Choi, D.H.;Lee, D.D.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.40-45
    • /
    • 1994
  • $112^{\circ}$ rot. x-cut $LiTaO_{3}$ wafer was used as the substrate of SAW gas sensor. Dual delay line SAW device with IDTs which consist of the reference delay line and the sensing delay line was fabricated using photolithigraphy. Each IDTs had 10 finger pairs and finger spacing is 10 microns. One delay line channel is the reference, while the second is the sensing channel with Pb-phthalocyanine film in the propagation path. Pb-phthalocyanine film which is p-type organic semiconductor was evaporated in $10^{-5}$ torr vacuum using shadow mask selectively. Dual delay line oscillator was constructed by using the rf amplifier and AGC. Frequency of the IDTs had the range of $87{\sim}$89 MHz oscillation frequency. Oscillation frequency shifts were investigated as a function of the temperature and the concentration of $NO_{2}$ gas.

  • PDF

The Effects of Fowler's Position Change on Back Pain and Discomfort of the Patients Following Percutaneous Coronary Intervention (경피적 관상동맥중재술 후 반좌위 체위변경이 환자의 요통과 불편감에 미치는 효과)

  • Nam, So-Young;ChoiKwon, Smi
    • Perspectives in Nursing Science
    • /
    • v.7 no.1
    • /
    • pp.55-64
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effects of position change from supine to Fowler's on back pain and discomfort in patients who remained on bed rest after undergoing PCIs with a vascular closure device. Methods: Data was collected from 35 inpatients who were hospitalized in coronary-care unit to perform PCIs with a vascular closure device at S hospital in Seoul from December, 2006 to May, 2007. Back pain, discomfort, presence and grade of bleeding and hematoma from femoral arterial puncture site and blood pressure/pulse rate were measured prior to, 10 minutes, 1 hour and 2 hours after position change. Data was analyzed with descriptive statistics, $x^2$ tests and t-tests using SPSS/WIN 12.0 for Windows program. The level of significance (${\alpha}$) was set at 0.05 for this study. Results: We found that there was no significant difference in back pain and discomfort in 10 minutes after position change between the two groups. However, the experimental group reported significantly less back pain and discomfort than the control group in 1 hour (p<.01, respectively) and 2 hour (p<.01, respectively) after position change. There was no significant difference in the presence and grade of bleeding and hematoma at the puncture site, blood pressure, and pulse rate in 10 minutes, 1hour and 2hours after position change between the two groups. Conclusion: Fowler's position change after PCIs in, therefore, safe and effective method of reducing back pain and physical discomfort without causing additional bleeding and changes in blood pressure and pulse rate.

  • PDF

Anisotropic etching of polysilicon in a $Cl_2/CH_3Br/O_2$ Plasma

  • Yi, Whi-Kun
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.24-29
    • /
    • 1999
  • The characteristic behaviors of CH3Br were examined first for the dry etching of polysilicon in a Cl2/CH3Br/O2 plasma. CH3Br is revealed one of the excellent additive gases to control anisotropy of etching profile and to give no undercutting for various typed of polysilicons. CH3Br acts as a passivation precursor on the side wall in etch cavity by forming polymer-like films such as CHxBry(x+y=1,2). The decrease of etch selectivity due to the reaction if the C-containing species from CH3Br with the surface O atoms of SiO2 was overcome by the addition of O2 into plasma, resulting that the selectivity increased by 2~3 times. According to the results of optical emission signals, CH3Br should be dissociated into several fragments to give more hydrogen atoms than bromine atoms in our helical resonator system.

  • PDF

A Prospective, Multi-Center, Double-Blind, Randomized Study to Evaluate the Efficacy and Safety of the Synthetic Bone Graft Material DBM Gel with rhBMP-2 versus DBM Gel Used during the TLIF Procedure in Patients with Lumbar Disc Disease

  • Hyun, Seung-Jae;Yoon, Seung Hwan;Kim, Joo Han;Oh, Jae Keun;Lee, Chang-Hyun;Shin, Jun Jae;Kang, Jiin;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.562-574
    • /
    • 2021
  • Objective : This study is to evaluate the efficacy and safety of demineralized bone matrix (DBM) gel versus DBM gel with recombinant human bone morphogenetic protein-2 (rhBMP-2) used in transforaminal lumbar interbody fusion (TLIF). Methods : This study was designed as a prospective, multi-center, double-blind method, randomized study. All randomized subjects underwent TLIF with DBM gel with rhBMP-2 group (40 patients) as an experimental group or DBM gel group (36 patients) as a control group. Post-operative observations were performed at 12, 24, and 48 weeks. The spinal fusion rate on computed tomography scans and X-rays films, Visual analog scale pain scores, Oswestry disability index and SF-36 quality of life (QOL) scores were used for the efficacy evaluation. The incidence rate of adverse device effects (ADEs) and serious adverse device effects (SADEs) were used for safety evaluation. Results : The spinal fusion rate at 12 weeks for the DBM gel with rhBMP-2 group was higher with 73.68% compared to 58.82% for the DBM gel group. The 24 and 48 weeks were 72.22% and 82.86% for the DBM gel with rhBMP-2 group and 78.79% and 78.13%, respectively, for the DBM gel group. However, there were no significant differences between two groups in the spinal fusion rate at 12, 24, and 48 weeks post-treatment (p=0.1817, p=0.5272, p=0.6247). There was no significant difference between the two groups in the incidence rate of ADEs (p=0.3836). For ADEs in the experimental group, 'Pyrexia' (5.00%) was the most common ADE, followed by 'Hypesthesia', 'Paresthesia', 'Transient peripheral paralysis', 'Spondylitis' and 'Insomnia' (2.50%, respectively). ADEs reported in control group included 'Pyrexia', 'Chest discomfort', 'Pain', 'Osteoarthritis', 'Nephropathy toxic', 'Neurogenic bladder', 'Liver function analyses' and 'Urticaria' (2.86%, respectively). There was no significant difference between the two groups in the incidence rate of SADEs (p=0.6594). For SADE in the experimental group, ''Pyrexia' and 'Spondylitis' were 2.50%. SADE reported in the control group included 'Chest discomfort', 'Osteoarthritis' and 'Neurogenic bladder'. All SADEs described above were resolved after medical treatment. Conclusion : This study demonstrated that the spinal fusion rates of DBM gel group and DBM gel with rhBMP-2 group were not significantly different. But, this study provides knowledge regarding the earlier postoperative effect of rhBMP-2 containing DBM gel and also supports the idea that the longer term follow-up results are essential to confirm the safety and effectiveness.

A Study on Combustion Characteristics in terms of the Type of Fuel Supply Device (Feeder) of a Wood Pellet Boiler (목재펠릿보일러의 연료공급 장치의 형태에 따른 연소특성에 관한 연구)

  • Choi, Yun Sung;Euh, Seung Hee;Oh, Kwang Cheol;Kim, Dae Hyun;Oh, Jae Heun
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.120-128
    • /
    • 2015
  • This study reports the combustion characteristics, such as burner temperature and the concentration of exhausted gas ($O_2$, $CO_x$, $NO_x$) due to the different types and pitches of the fuel supply feeder of the wood pellet boiler. The 1st grade wood pellets composed of mainly larch have been used for the experiment. In case of using the spring feeder, mean temperature of burner was approximately $821.76^{\circ}C$, and the mean concentration of oxygen, carbon monoxide, carbon dioxide and nitrogen oxide were approximately 8.88%, 93.35ppm, 12.15% and 139.83 ppm, respectively. The test result with the spring feeder was shown to approach the condition of complete combustion compared to that of a screw feeder and were in good agreement with authentication judgement standard. Furthermore, the combustion efficiency was improved according to the growth of screw pitch. The control of air flow rate from the blower and ventilator is needed to achieve the complete combustion.

Design and Implementation of $\pi/4$ QPSK Satellite IP Modem Part ($\pi/4$ QPSK 위성 IP 모뎀부 설계 및 구현)

  • Kang, Jung-Mo;Jung, Jae-Wook;Kim, Myung-Sik;Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1858-1865
    • /
    • 2007
  • In this paper, we introduce the design and implementation of satellite IP modem. The designed satellite IP modem shows the performance of 0.2% overhead, BER=10-5 when Eb/No=6dB, frequency offset of 8KHz, data rate up to 1536Kbps, $F_{if}=140MHz$. The designed system is verified through software simulation and then implemented with MPC86x communication processor, TMS320C6416 DSP, and Altera FPGA. Since each hardware unit is implemented in daughter board for modularity, we can reduce the development time and easily improve the performance with using better processor. Linux is used for embedded OS because it shows better performance in IP manipulation multitask processing, and hardware control through device driver. The implemented system is tested and verified with channel simulator. Since the proposed IP modem shows small size and light weight, that can be used anywhere with easy if you need IP environment.

Analysis on infection control of general hospital radiology (종합병원 영상의학과의 감염관리 대한 분석)

  • Shin, Jung-Sub;Park, Cheol-Woo;Jeon, Byeong-Kyou
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.335-342
    • /
    • 2012
  • This study aims to find a way to control infection of community radiology effectively by calculating the degree of contamination, culture and identifying the flora in radiology of five general hospitals in Gyeongsangbuk-do. Staphylococcus, Micrococcus, Pseudomonas stutzeri, Pseudomonas oryzihabitans were identified as surface flora. These are know to be pathogens of hospital acquired infection and there was no radiology-specific flora. Research subject hospitals were conducting similar infection control education but degree of contamination of each hospital showed significant difference. Difference in degree of contamination according to contact sources were analyzed by Contact sources were classified into technologist-using, patients-using and common-using materials. Analysis of each hospital's degree of contamination showed that patient-using materials were significantly more contaminated than technologist-using and common-using materials (p<0.001). Devices which are similar to each other in monthly average frequency of use showed no significant difference in degree of contamination, but general X-ray devices and chest boards which are used most frequently showed higher degree of contamination than others. In addition, hospital A, B and C which have heavier monthly average caseload showed relatively high degree of contamination on irradiation devices which are used by technologists only or by technologists and patients commonly, office desks and doorpulls. Hence it is considered that intensity of infection control education should be different according to the degree of monthly average caseload. This study provided an opportunity to aware that technologists' feeling of contamination is crucial for infection control of radiology, and the Accupoint ATP public hygiene monitoring system which was used in this study for measuring the degree of contamination was proved to be an effective measuring device for hospital acquired infection management.

The Radioprotection Effect of Aronia on Livers of Laboratory Rats Radiated to 6 MV X-ray of Linear Accelerator (선형가속기 6 MV X선에 조사된 흰쥐의 간에서 아로니아의 방사선 방호효과)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.97-104
    • /
    • 2020
  • This aimed at figuring out if there were the radioprotection effects of aronia on livers of laboratory rats radiated through serum test. For the objects of animal testing, one group consists of five male laboratory rats (weight 200~250 g), and the groups were set as follows: Group 1, normal; Group 2, 5 Gy radiated control group; and Group 3, 5 Gy radiated experiment group with aronia. Group 1(A) was prescribed with ordinary meal without radiation while the control group, Group 2(B) was prescribed with ordinary meal and radiation, and the experiment group, Group 3(C) was orally prescribed with aronia (daily oral dosage: 100 mg/kg/day) diluted with distilled water at the amount of 50 mg/kg/day twice a week, using oral zonde needle for rats for 14 days before being radiated, and then, radiation were made on them. For the study, using Linac (Linear Accelerator) 6 MV X-ray therapy device, rats were irradiated on their whole bodies once, and their blood was sampled for conducting five blood serum tests with regard to liver. For statistical analysis, ANOVA test was conducted. In conclusion, as a result of the analysis, it seemed that there were no the radioprotection effects of aronia on liver. However, it was confirmed statistically that ALB (P>0.05) showed no significance and that TP (P<0.05) showed significant differences. It is expected that there should be more tests in future.