• Title/Summary/Keyword: $NO_2$ sensor

Search Result 604, Processing Time 0.03 seconds

Study on Rotating Speed of Kite Wind Turbine System and Design of PM Generator (연 풍력시스템의 회전속도 측정 및 발전기 시스템에 적용 가능한 영구자석 발전기 설계에 관한 연구)

  • Shin, Yujeong;Kim, Soo-Hyun;Kim, Jin Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.141-147
    • /
    • 2016
  • A direct PM generator has the effect of reducing the mechanical noise and ease of maintenance by eliminating a number of power transmission components. In addition, wind turbines operating at low speed with the advantages of high output, high efficiency, and small size. The generator was designed as a small direct-drive PM generator that can be applied to a kite even at low wind speeds. The RPM (Revolutions Per Minute) of the reel was measured in two ways using a cadence/speedometer sensor and a tachometer while the actual kite. The RPM derived from the experiment was applied to the simulation on the designed generator. The no-load characteristic analysis for the magnetic fields produced for the permanent magnet generator by a permanent magnet and stator winding currents is achieved using a 2D coordinate system. A commercial electromagnetic analysis program, ANSYS Maxwell, was used to model the electromagnetic dynamics.

Crystal Structure and Optical Absorption of ZnO Thin Films Grown by Electrodeposition (전착법에 의한 ZnO 박막의 결정구조 및 광흡수 특성)

  • Choi, C.T.;Seo, J.N.
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.455-460
    • /
    • 2000
  • Zinc oxide(ZnO) thin films were cathodically deposited on ITO glass from an aqueous zinc nitrate electrolyte. Three main fabrication parameters were taken into account : deposition potential, solution concentration and growth temperature. Different layers of ZnO thin films grown by varying the three parameters were studied by X-ray diffraction, scanning electron microscope and optical absorption spectroscopy. The prepared ZnO thin films were shown as a hexagonal wurtzite structure on the X-ray diffraction patterns and the good quality of ZnO thin films were obtained by potentiostatic cathodic deposition at -0.7V vs. Ag/AgCl reference electrode onto ITO glass from aqueous 0.1 mol/liter zinc nitrate electrolyte at $60^{\circ}C$.

  • PDF

Examination on the variation of ride comfort for korean high speed train through on-line test (시운전 시험을 통한 한국형 고속열차의 승차감 변화추세에 관한 연구)

  • Kim, Young-Guk;Mok, Jin-Yong;Kim, Seog-Won;Park, Chan-Kyeong;Kim, Ki-Hwan;Park, Tae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.144-149
    • /
    • 2005
  • In this paper, we introduce the variation of ride characteristics for HSR 350x(Korea High Speed Train project) through on-line test during about 3 years. The concept of term "ride comfort" is equivocal. Generally it is evaluated as the vehicle vibration. The ride comfort for HSR 350x has been assessed by statistical method according to UIC 513R. The testing results show that HSR 350x has no problems from the viewpoint of the comfort ride on the high speed line and conventional line and that 1st and 2nd suspensions play an important role in the ride characteristics for high speed train.

The Effects of Quantitative Occlusal Force on Size of Temporomandibular Joint Space (정량적 교합력이 측두하악관절강 크기에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.1
    • /
    • pp.21-29
    • /
    • 1993
  • The purpose of this study was to evaluation of temporomandibulr joint space according to increasing the occlusal force on working and non-working side during unilateral bite. For the study, 22 normal adults, age ranged from 23 to 25, who had no symptoms on TMJ area and masticatory muscles and had normal or class I molar relationship were selected. Transcranial TMJ radiograph was taken during unilateral biting with sensor of Bite force checker (Nihon Kohden Kygyo Co.Ltd., Japan) on each 1st molar teeth of right and left side which were forced each 0Kg, 10Kg, 20Kg and 30Kg by use of Accurad-200 (Denar Corperation's product). The radiographs were traced on the screen, which was magnified by 5. The size of temporomandibular joint space at anterior, superior and posterior compartment were measured with Dumas's method (reference line of between squamotympanic fissure and the most inferior point of articular eminence). On the basis of this study, the following results were obtained. 1. Size of anterior TMJ space was tend to decrease on the working side and increase on the non-working side according to increasing the occlusal force, but not significant statistically (p>0.05). 2. Size of superior TMJ space was tend to increase on the working side and decrease on the non-working side according to increasing the occlusal force (p<0.05). 3. Size of posterior TMJ space was tend to decrease on both working ad nonworking side, but non significant statistically.

  • PDF

Gas Sensing Properties of Powder Prepared from Waste Thermoelectric Devices by Wet Reduction Process

  • So, Hyeongsub;Im, Dong-Ha;Jung, Hyunsung;Lee, Kun-Jae
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.90-93
    • /
    • 2018
  • In this study, n-type $Bi_2Te_3$ in thermoelectric scrap is recovered through a wet reduction process. The recovered powder (tellurium) is grafted onto gas sensor in a new application that is not a thermoelectric device. Bismuth-rich powder is prepared by adding hydrazine when pH of the solution is brought to 13 using NaOH. The pH of the filtered solution was reduced using $HNO_3$, and then hydrazine was added to perform the re-reduction reaction. The tellurium-rich powder can be obtained through this reaction. The elemental analysis for these powders is confirmed by energy dispersive X-ray spectroscopy (EDS) analysis ; the successful separation of bismuth and tellurium is confirmed. Separated tellurium powder is mixed with DMF solvent and ethyl cellulose binder to confirm gas sensing properties. The tellurium paste was exposed in $NO_x$ atmosphere and exhibited a rapid reaction rate and recovery rate of less than 3 minutes for the gas.

Properties Evaluation on Aluminum for Die-casting(ADC 12) to Packing Case of Composite Sensor (복합센서 케이스용 알루미늄 다이캐스팅(ADC 12) 합금의 특성평가)

  • Son, Jae-Hwan;Oh, Sang-Kyun;Kim, Dong-Bae;Han, Chang-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.141-145
    • /
    • 2006
  • In case of sense case manufactured by method of outage capacity, sensitivity is declined by outside effect and method of the photo electricity has a problem in transmission. therefore, packing case of composite sense should be developed to improve such a problem about influence of outside environment and its property evaluation has been performed. Mechanical property and result of analysis & test evaluation of Mat'l on aluminum die-casting(ADC 12type) Mat'l developed are as following. Tensile test piece, No. 4 of KS B 0801, has been applied to mechanical property test of Mat'l and It has been tested by method of metal mat'l tensile test(KS B 0802 : 2003). It can be found that physical property to KS(Korea Standard) is excellent. and homogeneous mechanical property appears. Test of Mat'l analysis has been performed by using OE Spectrometer, according to ASTM E 1251 : 1994 regulation. Consequently, good and homogeneous component contents classified by element to standard, except for Fe, have been obtained with coordination of Fe content as below 1.3% from composition standard of Aluminum Die-casting.

  • PDF

A Robotic System for Transferring Tobacco Seedlings

  • Lee, D.W.;W.F.McClure
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.850-858
    • /
    • 1993
  • Germinatin and early growth of tobacco seedlings in trays containing many cells is increasing in popularity . Since 100 % germination is not likely , a major problem is to locate and replace the content of those cells which contain either no seedling or a stunted seedling with a plug containing a viable seedling. Empty cells and seedlings of poor quality take up valuable space in a greenhouse. They may also cause difficulty when transplanting seedlings into the field. Robotic technology, including the implementation of computer vision, appears to be an attractive alternative to the use of manual labor for accomplishing this task. Operating AGBOT, short for Agricultural ROBOT, involved four steps : (1) capturing the image, (2) processing the image, (3) moving the manipulator, (4) working the gripper. This research seedlings within a cell-grown environment. the configuration of the cell-grown seedling environment dictated the design of a Cartesian robot suitable for working ov r a flat plane. Experiments of AGBOT performance in transferring large seedlings produced trays which were more than 98% survived one week after transfer. In general , the system generated much better than expected.

  • PDF

Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis (임플란트 보철의 교합 접촉 변화에 대한 임상적 평가)

  • Yun, Chul-Hee;Kim, Dae-Gon;Yi, Yang-Jin;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Inference of Sequencing Batch Reactor Process using Oxidation Reduction Potential (ORP profile을 이용한 연속 회분식 반응기(Sequencing Batch Reactor)에서 무산소공정 추론)

  • Sim, Mun Yong;Bu, Gyeong Min;Im, Jeong Hun;U, Hye Jin;Kim, Chang Won
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • The SBR(Sequencing Batch Reactor) process is ideally suited to treat high loading wastewater due to its high dilution rate. SBR operates by a cycle of periods consisting of filling, reacting, settling, decanting and idling. The react phases such as aeration or non-aeration, organic oxidation, nitrification, denitrification and other bio-logical reactions can be achieved in a reactor. Although the whole reactions can be achieved in a SBR with time distributing, it is hard to manage the SBR as a normal condition without recognizing a present state. The present state can be observed with nutrient sensors such as ${NH_{4}}^{+}-N$, ${NO_{2}}^{-}-N$, ${NO_{3}}^{-}-N} and ${PO_{4}}^{ 3-}-P.$ However, there is still a disadvantage to use the nutrient sensors because of their high expense and inconvenience to manage. Therefore, it is very useful to use common on-line sensors such as DO, ORP and pH, which are less expensive and more convient. Moreover, the present states and unexpected changes of SBR might be predicted by using of them. This study was conducted to get basic materials for making an inference of SBR process from ORP(oxidation reduction potential) of synthetic wastewater. The profiles of ORP, DO, and pH were under normal nitrification and denitrification were obtained to compare abnormal condition. And also, nitrite and nitrate accumulation were investigated during reaction of SBR. The bending point on ORP profile was not entirely in the low COD/NOx ratio condition. In this case, NOx was not entirely removed, and minimum ORP value was presented over -300mV. Under suitable COD/NOx ratio which complete denitrification was achieved, ORP bending point was observed and minimum ORP value was under -300m V. Under high COD/NOx ratio, ORP bending point was not detected at the first subcycle because of the fast denitrification and minimum ORP value was under -300mV at the time.

Development and Evaluation of Real-time Acoustic Detection System of Harmful Red-tide Using Ultrasonic Sound (초음파를 이용한 유해적조의 실시간 음향탐지 시스템 개발 및 평가)

  • Kang, Donhyug;Lim, Seonho;Lee, Hyungbeen;Doh, Jaewon;Lee, Youn-Ho;Choi, Jee Woong
    • Ocean and Polar Research
    • /
    • v.35 no.1
    • /
    • pp.15-26
    • /
    • 2013
  • The toxic, Harmful Algal Blooms (HABs) caused by the Cochlodinium polykrikoides have a serious impact on the coastal waters of Korea. In this study, the acoustic detection system was developed for rapid HABs detection, based on the acoustic backscattering properties of the C. polykrikoides. The developed system was mainly composed of a pulser-receiver board, a signal processor board, a control board, a network board, a power board, ultrasonic sensors (3.5 and 5.0 MHz), an environmental sensor, GPS, and a land-based control unit. To evaluate the performance of the system, a trail was done at a laboratory, and two in situ trials were conducted: (1) when there was no red tide, and (2) when there was red tide. In the laboratory evaluation, the system performed well in accordance with the number of C. polykrikoides in the received level. Second, under the condition when there was no red tide in the field, there was a good correlation between the acoustic data and sampling data. Finally, under the condition when there was red tide in the field, the system successfully worked at various densities in accordance with the number of C. polykrikoides, and the results corresponded with the sampling data and monitoring result of NFRDI (National Fisheries Research & Development Institute). From the laboratory and field evaluations, the developed acoustic detection system for early detecting HABs has demonstrated that it could be a significant system to monitor the occurrence of HABs in coastal regions.